Xiaofeng Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaofeng Chang has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Michael D. Weir
Department of Advanced Oral Sciences and Therapeutics, University of Maryland School of Dentistry, Baltimore, USA
8 shared publications- Hockin H. K. Xu
Biomaterials & Tissue Engineering Division, Department of Advanced Oral Sciences and Therapeutics, University of Maryland Dental School, Baltimore, MD 21201, USA
6 shared publications Jianping Ruan
Key Laboratory of Shannxi Province for Craniofacial Precision Medicine Research, Clinical Research Center of Shannxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi’an Jiaotong University, Xi’an, Shannxi, China
5 shared publicationsThomas W. Oates
Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, MD 21021, USA
4 shared publications- Jianping Ruan
Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, China; Department of Preventive Dentistry, College of Stomatology, Xi'an Jiaotong University, Xi'an, China; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, China
3 shared publications Boya Xu
Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
2 shared publications
Latest Publications
- Open Access
- 24 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 167, 106523
An alternative radiation-free method for assessing the accuracy of robotic computer-assisted implant surgery: a cross-sectional study
- 24 January 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 167, 106523
Open AccessAn alternative radiation-free method for assessing the accuracy of robotic computer-assisted implant surgery: a cross-sectional study
- Open Access
- 19 September 2025
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 11 (5) , e70223
Low Intensity Thermal Stimulation to Enhance Early Osteointegration in Implants: A Preclinical Study in Rabbits
Objectives: This study is the first to integrate 3D finite element modeling, in vitro validation, and preclinical animal experiments to determine the efficacy of low‐intensity thermal stimulation (LITS) in enhancing dental implant osseointegration. The study seeks to provide experimental evidence for applying thermal stimulation as a possible approach to enhance osseointegration.Material and Methods: A 3D finite element implant‐femur model and in vitro implant‐bone system were developed to simulate heat distribution. LITS conditions (50°C/5 s) were validated to avoid exceeding the osteoblast safety threshold (47°C). Eighteen rabbits received femoral implants divided into: control (no heating), T1 (single 50°C/5 s heating cycle), and T2 (three cycles). Outcomes included implant stability (IST), reverse torque, bone volume fraction (BV/TV), and histomorphometric osseointegration rate at 6 weeks.Results: Finite element and in vitro analyses confirmed 50°C/5 s as the optimal protocol, maintaining implant surface temperatures ≤ 46.3°C and complete thermal recovery within 1 min. T1 significantly increased in vivo rabbit model reverse torque (p < 0.05) and BV/TV (p < 0.05), while T2 showed no BV/TV improvement. Both T1 and T2 exhibited higher osseointegration rates (p < 0.05). Implant stability (IST) remained unchanged across groups (p > 0.05).Conclusion: LITS at 50°C/5 s safely enhances early osseointegration in rabbits, increasing biomechanical anchorage and peri‐implant bone formation. This study provides preliminary experimental evidence for the potential of thermal application in enhancing implant osseointegration.
- 19 September 2025
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 11 (5) , e70223
Open AccessLow Intensity Thermal Stimulation to Enhance Early Osteointegration in Implants: A Preclinical Study in Rabbits
Objectives: This study is the first to integrate 3D finite element modeling, in vitro validation, and preclinical animal experiments to determine the efficacy of low‐intensity thermal stimulation (LITS) in enhancing dental implant osseointegration. The study seeks to provide experimental evidence for applying thermal stimulation as a possible approach to enhance osseointegration.Material and Methods: A 3D finite element implant‐femur model and in vitro implant‐bone system were developed to simulate heat distribution. LITS conditions (50°C/5 s) were validated to avoid exceeding the osteoblast safety threshold (47°C). Eighteen rabbits received femoral implants divided into: control (no heating), T1 (single 50°C/5 s heating cycle), and T2 (three cycles). Outcomes included implant stability (IST), reverse torque, bone volume fraction (BV/TV), and histomorphometric osseointegration rate at 6 weeks.Results: Finite element and in vitro analyses confirmed 50°C/5 s as the optimal protocol, maintaining implant surface temperatures ≤ 46.3°C and complete thermal recovery within 1 min. T1 significantly increased in vivo rabbit model reverse torque (p < 0.05) and BV/TV (p < 0.05), while T2 showed no BV/TV improvement. Both T1 and T2 exhibited higher osseointegration rates (p < 0.05). Implant stability (IST) remained unchanged across groups (p > 0.05).Conclusion: LITS at 50°C/5 s safely enhances early osseointegration in rabbits, increasing biomechanical anchorage and peri‐implant bone formation. This study provides preliminary experimental evidence for the potential of thermal application in enhancing implant osseointegration.
- Open Access
- 3 January 2025
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 11 (1) , 1-11
Accuracy of robot-assisted implant surgery versus freehand placement: a retrospective clinical study
Purpose: This study evaluated the accuracy of implant placement using a robotic system (Remebot) compared to freehand surgery and explored factors influencing accuracy. Methods: This retrospective study included 95 implants placed in 65 patients, divided into robot-assisted (50 implants) and freehand (45 implants) groups. Platform, apical, and angular deviations were measured by superimposing preoperative plans and the postoperative CBCT images. Mean deviations between groups were compared, and regression analysis assessed the impact of implant dimensions and positioning on accuracy. Results: The robot-assisted group exhibited significantly lower mean deviations in platform (0.44 ± 0.17 mm), apical (0.46 ± 0.17 mm), and angular deviations (0.85 ± 0.47°) compared to the freehand group (1.38 ± 0.77 mm, 1.77 ± 0.82 mm, and 6.63 ± 3.90°, respectively; p < 0.001). Regression analysis indicated no significant impact of implant location, jaw type, or implant dimensions on the robotic system’s accuracy, unlike the freehand placement where these factors influenced deviations. Conclusions: Robot-assisted implant surgery significantly enhances accuracy and clinical safety compared to freehand techniques. Despite limitations, robotic surgery presents a promising advancement in implant dentistry by reducing human error.
- 3 January 2025
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 11 (1) , 1-11
Open AccessAccuracy of robot-assisted implant surgery versus freehand placement: a retrospective clinical study
Purpose: This study evaluated the accuracy of implant placement using a robotic system (Remebot) compared to freehand surgery and explored factors influencing accuracy. Methods: This retrospective study included 95 implants placed in 65 patients, divided into robot-assisted (50 implants) and freehand (45 implants) groups. Platform, apical, and angular deviations were measured by superimposing preoperative plans and the postoperative CBCT images. Mean deviations between groups were compared, and regression analysis assessed the impact of implant dimensions and positioning on accuracy. Results: The robot-assisted group exhibited significantly lower mean deviations in platform (0.44 ± 0.17 mm), apical (0.46 ± 0.17 mm), and angular deviations (0.85 ± 0.47°) compared to the freehand group (1.38 ± 0.77 mm, 1.77 ± 0.82 mm, and 6.63 ± 3.90°, respectively; p < 0.001). Regression analysis indicated no significant impact of implant location, jaw type, or implant dimensions on the robotic system’s accuracy, unlike the freehand placement where these factors influenced deviations. Conclusions: Robot-assisted implant surgery significantly enhances accuracy and clinical safety compared to freehand techniques. Despite limitations, robotic surgery presents a promising advancement in implant dentistry by reducing human error.
- Top Cited PapersOpen Access
- 14 May 2024
- Published by Springer Nature in Head & Face Medicine
- Vol. 20 (1) , 1-10
Accuracy of dynamic navigation compared to static surgical guides and the freehand approach in implant placement: a prospective clinical study
Background: Computer-guided implant surgery has improved the quality of implant treatment by facilitating the placement of implants in a more accurate manner. This study aimed to assess the accuracy of implant placement in a clinical setting using three techniques: dynamic navigation, static surgical guides, and freehand placement. We also investigated potential factors influencing accuracy to provide a comprehensive evaluation of each technique’s advantages and disadvantages. Materials and methods: Ninety-four implants in 65 patients were included in this prospective study. Patients were randomly assigned to one of three groups: dynamic navigation, static surgical guides, or freehand placement. Implants were placed using a prosthetically oriented digital implant planning approach, and postoperative CBCT scans were superimposed on preoperative plans to measure accuracy. Seven deviation values were calculated, including angular, platform, and apical deviations. Demographic and consistency analyses were performed, along with one-way ANOVA and post-hoc tests for deviation values. Results: The mean global platform, global apical, and angular deviations were 0.99 mm (SD 0.52), 1.14 mm (SD 0.56), and 3.66° (SD 1.64°) for the dynamic navigation group; 0.92 mm (SD 0.36), 1.06 mm (SD 0.47), and 2.52° (SD 1.18°) for the surgical guide group; and 1.36 mm (SD 0.62), 1.73 mm (SD 0.66), and 5.82° (SD 2.79°) for the freehand group. Both the dynamic navigation and surgical guide groups exhibited statistically significant differences in all values except depth deviations compared to the freehand group (p < 0.05), whereas only the angular deviation showed a significant difference between the dynamic navigation and surgical guide groups (p = 0.002). Conclusion: Our findings highlight the superior accuracy and consistency of dynamic navigation and static surgical guides compared to freehand placement in implant surgery. Dynamic navigation offers precision and flexibility. However, it comes with cost and convenience considerations. Future research should focus on improving its practicality. Trial Registration: This study was retrospectively registered at the Thai Clinical Trials Register-Medical Research Foundation of Thailand (MRF) with the TCTR identification number TCTR20230804001 on 04/08/2023. It was also conducted in accordance with the Declaration of Helsinki and approved by the institutional ethics committee at the Xian Jiaotong University Hospital of Stomatology, Xian, China (xjkqII[2021] No: 043). Written informed consent was obtained from all participants.
- 14 May 2024
- Published by Springer Nature in Head & Face Medicine
- Vol. 20 (1) , 1-10
Top Cited PapersOpen AccessAccuracy of dynamic navigation compared to static surgical guides and the freehand approach in implant placement: a prospective clinical study
Background: Computer-guided implant surgery has improved the quality of implant treatment by facilitating the placement of implants in a more accurate manner. This study aimed to assess the accuracy of implant placement in a clinical setting using three techniques: dynamic navigation, static surgical guides, and freehand placement. We also investigated potential factors influencing accuracy to provide a comprehensive evaluation of each technique’s advantages and disadvantages. Materials and methods: Ninety-four implants in 65 patients were included in this prospective study. Patients were randomly assigned to one of three groups: dynamic navigation, static surgical guides, or freehand placement. Implants were placed using a prosthetically oriented digital implant planning approach, and postoperative CBCT scans were superimposed on preoperative plans to measure accuracy. Seven deviation values were calculated, including angular, platform, and apical deviations. Demographic and consistency analyses were performed, along with one-way ANOVA and post-hoc tests for deviation values. Results: The mean global platform, global apical, and angular deviations were 0.99 mm (SD 0.52), 1.14 mm (SD 0.56), and 3.66° (SD 1.64°) for the dynamic navigation group; 0.92 mm (SD 0.36), 1.06 mm (SD 0.47), and 2.52° (SD 1.18°) for the surgical guide group; and 1.36 mm (SD 0.62), 1.73 mm (SD 0.66), and 5.82° (SD 2.79°) for the freehand group. Both the dynamic navigation and surgical guide groups exhibited statistically significant differences in all values except depth deviations compared to the freehand group (p < 0.05), whereas only the angular deviation showed a significant difference between the dynamic navigation and surgical guide groups (p = 0.002). Conclusion: Our findings highlight the superior accuracy and consistency of dynamic navigation and static surgical guides compared to freehand placement in implant surgery. Dynamic navigation offers precision and flexibility. However, it comes with cost and convenience considerations. Future research should focus on improving its practicality. Trial Registration: This study was retrospectively registered at the Thai Clinical Trials Register-Medical Research Foundation of Thailand (MRF) with the TCTR identification number TCTR20230804001 on 04/08/2023. It was also conducted in accordance with the Declaration of Helsinki and approved by the institutional ethics committee at the Xian Jiaotong University Hospital of Stomatology, Xian, China (xjkqII[2021] No: 043). Written informed consent was obtained from all participants.
- 29 September 2022
- Published by Springer Nature in Journal of Bionic Engineering
- Vol. 19 (6) , 1658-1670
3D-printed Mechanically Strong Calcium Phosphate Cement Scaffold with Metformin/Stem Cell-encapsulating Alginate Microbeads for Bone Tissue Engineering
- 29 September 2022
- Published by Springer Nature in Journal of Bionic Engineering
- Vol. 19 (6) , 1658-1670
3D-printed Mechanically Strong Calcium Phosphate Cement Scaffold with Metformin/Stem Cell-encapsulating Alginate Microbeads for Bone Tissue Engineering
- 1 June 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (6) , 1009-1019
Effect of co-precipitation plus spray-drying of nano-CaF2 on mechanical and fluoride properties of nanocomposite
- 1 June 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (6) , 1009-1019
Effect of co-precipitation plus spray-drying of nano-CaF2 on mechanical and fluoride properties of nanocomposite
- 1 August 2019
- Published by Elsevier in Dental Materials
- Vol. 35 (8) , 1104-1116
Self-healing adhesive with antibacterial activity in water-aging for 12 months
- 1 August 2019
- Published by Elsevier in Dental Materials
- Vol. 35 (8) , 1104-1116
Self-healing adhesive with antibacterial activity in water-aging for 12 months
- 1 July 2019
- Published by Elsevier in Dental Materials
- Vol. 35 (7) , 1031-1041
Calcium phosphate cement scaffold with stem cell co-culture and prevascularization for dental and craniofacial bone tissue engineering
- 1 July 2019
- Published by Elsevier in Dental Materials
- Vol. 35 (7) , 1031-1041
Calcium phosphate cement scaffold with stem cell co-culture and prevascularization for dental and craniofacial bone tissue engineering
- Top Cited PapersOpen Access
Periodontal Bone-Ligament-Cementum Regeneration via Scaffolds and Stem Cells
Periodontitis is a prevalent infectious disease worldwide, causing the damage of periodontal support tissues, which can eventually lead to tooth loss. The goal of periodontal treatment is to control the infections and reconstruct the structure and function of periodontal tissues including cementum, periodontal ligament (PDL) fibers, and bone. The regeneration of these three types of tissues, including the re-formation of the oriented PDL fibers to be attached firmly to the new cementum and alveolar bone, remains a major challenge. This article represents the first systematic review on the cutting-edge researches on the regeneration of all three types of periodontal tissues and the simultaneous regeneration of the entire bone-PDL-cementum complex, via stem cells, bio-printing, gene therapy, and layered bio-mimetic technologies. This article primarily includes bone regeneration; PDL regeneration; cementum regeneration; endogenous cell-homing and host-mobilized stem cells; 3D bio-printing and generation of the oriented PDL fibers; gene therapy-based approaches for periodontal regeneration; regenerating the bone-PDL-cementum complex via layered materials and cells. These novel developments in stem cell technology and bioactive and bio-mimetic scaffolds are highly promising to substantially enhance the periodontal regeneration including both hard and soft tissues, with applicability to other therapies in the oral and maxillofacial region.
Top Cited PapersOpen AccessPeriodontal Bone-Ligament-Cementum Regeneration via Scaffolds and Stem Cells
Periodontitis is a prevalent infectious disease worldwide, causing the damage of periodontal support tissues, which can eventually lead to tooth loss. The goal of periodontal treatment is to control the infections and reconstruct the structure and function of periodontal tissues including cementum, periodontal ligament (PDL) fibers, and bone. The regeneration of these three types of tissues, including the re-formation of the oriented PDL fibers to be attached firmly to the new cementum and alveolar bone, remains a major challenge. This article represents the first systematic review on the cutting-edge researches on the regeneration of all three types of periodontal tissues and the simultaneous regeneration of the entire bone-PDL-cementum complex, via stem cells, bio-printing, gene therapy, and layered bio-mimetic technologies. This article primarily includes bone regeneration; PDL regeneration; cementum regeneration; endogenous cell-homing and host-mobilized stem cells; 3D bio-printing and generation of the oriented PDL fibers; gene therapy-based approaches for periodontal regeneration; regenerating the bone-PDL-cementum complex via layered materials and cells. These novel developments in stem cell technology and bioactive and bio-mimetic scaffolds are highly promising to substantially enhance the periodontal regeneration including both hard and soft tissues, with applicability to other therapies in the oral and maxillofacial region.
- 1 February 2019
- Published by Elsevier in Journal of Dentistry
- Vol. 81, 91-101
Bonding durability, antibacterial activity and biofilm pH of novel adhesive containing antibacterial monomer and nanoparticles of amorphous calcium phosphate
- 1 February 2019
- Published by Elsevier in Journal of Dentistry
- Vol. 81, 91-101
Bonding durability, antibacterial activity and biofilm pH of novel adhesive containing antibacterial monomer and nanoparticles of amorphous calcium phosphate