Qiong Liu

Qiong Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qiong Liu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    How Safety Ritual Sense Affects Construction Workers’ Behavior: The Mediating Role of Safety Psychological Capital

    by Chao Yuan, Shizhen Guo, Weilin Xu, Qiong Liu

    Building a sustainable workplace necessitates a fundamental commitment to employee safety and psychological well-being, particularly in high-risk sectors like construction. While individual unsafe behavior is a primary cause of accidents, the psychological mechanisms linking organizational practices to safety outcomes remain underexplored from an industrial-organizational psychology perspective. This study examines the relationship between safety ritual sense (a psychological outcome of socio-affective organizational practices) and the safety behavior of construction workers, with safety psychological capital (a positive psychological resource) tested as a mediator. Data were collected via questionnaire surveys from 444 construction employees in China and analyzed using structural equation modeling. The results confirm a significant positive correlation between safety ritual sense and safety behavior. Furthermore, safety psychological capital significantly partially mediates this relationship, with its four dimensions—confidence, optimism, hope, and resilience—each playing distinct mediating roles. This research elucidates a critical psychological pathway through which ritualized organizational practices enhance safety performance. It provides empirical evidence that fostering safety rituals to cultivate employees’ psychological capital is an effective industrial-organizational psychology intervention, contributing directly to the development of safer, healthier, and more sustainable modern workplaces.

  • Open Access

    Numerical Study on Coupled Combustion of PMMA Counter-Directional Flame Spread at Variable Slope

    by Qiong Liu, Kehong Li, Chao Yuan, Ning Bian, Zhi Li, Weilin Xu, Jinrong Chen

    This paper investigates the dual effects of slope variation and flame interaction on counter-directional flame propagation through numerical simulations of polymethylmethacrylate (PMMA) plates. Critical flame propagation parameters, including flame morphology, flame spread speed, mass loss rate, and radiative heat flux density, were analyzed using the Fire Dynamics Simulator (FDS v6.7.5) software. By comparing counter-directional flames and unilateral flames under varying slope conditions, we evaluated how flame interactions influence flame spread speed and mass loss rate, as well as the role of the view factor in radiative heat flux distribution. Numerical results revealed that the counter-directional fire propagation process on slopes could be divided into four distinct stages based on variations in flame spread rate and mass loss rate. Moreover, we propose a novel method to quantify flame interaction intensity on slopes using flame spread time. These findings enhance the mechanistic understanding of slope-dependent counter-directional flame propagation.


  • Open Access

    Experimental Investigation of the Combustion Characteristics and Thermal Hazards of Methylsilyl-Modified Silica Aerogels

    by Xiaoxu Wu, Kai Shen, Min Hu, Fang Zhou, Zikang Chen, Qiong Liu, Zijun Li, Zhi Li

    The thermal safety of hydrophobic silica aerogels (SAs) is essential to thermal insulation applications. Herein, trimethylchlorosilane (TMCS), dimethyldichlorosilane (DMDCS), and methyltrichlorosilane (MTCS) were employed as surface modifiers to prepare three different methylsilyl-modified SAs (i.e., TSA, DSA, and MSA) and their combustion characteristics and thermal hazards were experimentally studied in detail. The cone calorimeter test found that the three SAs have similar combustion processes and the variations in ignition time and fire spread rate with the heat flux obey simple logarithmic and linear relationships, respectively. It further found that TSA has the most methylsilyl groups on silica skeletons and thus has the largest heat release, followed by DSA and MSA in turn, implying that TSA has the greatest fire hazard among the three SAs. These results further demonstrate that the type and quantity of methylsilyl groups on the skeletons of SAs significantly affect the thermal hazard of methylsilyl-modified SAs. In addition, the combustion mechanism of the methylsilyl-modified SAs is discussed. In total, this work experimentally studies the combustion characteristics of methylsilyl-modified SAs and compares their thermal hazards, clarifying the potential fire risk of methylsilyl-modified SAs in practical thermal insulation applications.


  • Open Access

    Enhancing Water Resistance in Foam Cement through MTES-Based Aerogel Impregnation

    by Zhi Li, Shengjie Yao, Guichao Wang, Xi Deng, Fang Zhou, Xiaoxu Wu, Qiong Liu

    The propensity of foamed concrete to absorb water results in a consequential degradation of its performance attributes. Addressing this issue, the integration of aerogels presents a viable solution; however, their direct incorporation has been observed to compromise mechanical properties, attributable to the effects of the interface transition zone. This study explores the incorporation of MTES-based aerogels into foamed cement via an impregnation technique, examining variations in water–cement ratios. A comprehensive analysis was conducted, evaluating the influences of MTES-based aerogels on the thermal conductivity, compressive strength, density, chemical composition, and microstructure of the resultant composites across different water–cement ratios. Our findings elucidate that an increment in the water–cement ratio engenders a gradual regularization of the pore structure in foamed concrete, culminating in augmented porosity and diminished density. Notably, aerogel-enhanced foamed concrete (AEFC) exhibited a significant reduction in water absorption, quantified at 86% lower than its conventional foamed concrete (FC) counterpart. Furthermore, the softening coefficient of AEFC was observed to surpass 0.75, with peak values reaching approximately 0.9. These results substantiate that the impregnation of MTES-based aerogels into cementitious materials not only circumvents the decline in strength but also bolsters their hydrophobicity and water resistance, indirectly enhancing the serviceability and longevity of foamed concrete. In light of these findings, the impregnation method manifests promising potential for broadening the applications of aerogels in cement-based materials.


  • Open Access

    Heat-Treated Aramid Pulp/Silica Aerogel Composites with Improved Thermal Stability and Thermal Insulation

    by Zhi Li, Kai Shen, Min Hu, Yury M. Shulga, Zhenkui Chen, Qiong Liu, Ming Li, Xiaoxu Wu

    In this work, we prepared heat-treated aramid pulp/silica aerogel composites (AP/aerogels) and investigated in detail the feasibility of improving thermal stability and thermal insulation via tailored heat treatment. The microstructure and FTIR spectra reveal that AP/aerogels are formed by a physical combination of the silica aerogel matrix and aramid pulps. When the heat treatment temperature increases, the density slightly decreases and then increases to the maximum due to the significant volume shrinkage. The pyrolysis of aramid pulp and the collapse of silica skeletons occur during heat treatment; nevertheless, the typical structures of AP/aerogels do not change significantly. It is also found that both the hydrophobicity and the thermal insulation decrease with the increasing heat treatment temperature. We note that when the heat treatment is at 600 °C, the AP/aerogel still maintains a low density of 0.19 g/cm3 and a contact angle of 138.5°. The thermal conductivity is as low as 26.11 mW/m/K, measured using the transient hot wire method. Furthermore, the heat-treated AP/aerogels can avoid heat shock and possible thermal hazards during practical thermal insulation applications. The onset temperatures of the thermal decomposition of AP/aerogels increase from 298.8 °C for an untreated one to 414.7 °C for one treated at 600 °C, indicating that the thermal stability of AP/aerogels is improved significantly. This work provides a practical engineering approach to expand the thermal insulation applications of silica aerogel composites.


  • Open Access

    Encapsulation of Paraffin Phase-Change Materials within Monolithic MTMS-Based Silica Aerogels

    by Linlin Xie, Xiaoxu Wu, Guichao Wang, Yury M. Shulga, Qiong Liu, Ming Li, Zhi Li

    To address the leakage issue of paraffin phase-change materials in thermal management, a monolithic MTMS-based silica aerogel (MSA) is employed to encapsulate paraffin through a facile impregnation process. We find that the paraffin and MSA form a physical combination, with little interaction occurring between them. The prepared no-leakage paraffin/MSA composites have a density of 0.70 g/cm3 and exhibit good mechanical properties and nice hydrophobicity, with a contact angle of 122°. Furthermore, the average latent heat of the paraffin/MSA composites is found to reach up to 209.3 J/g, about 85% of the pure paraffin’s latent heat, which is significantly larger than other paraffin/silica aerogel phase-change composite materials. The thermal conductivity of the paraffin/MSA remains almost the same as that of the pure paraffin (~250 mW/m/K), without any heat transfer interference from the MSA skeletons. All these results indicate that MSA can effectively serve as a carrier material for encapsulating paraffin, which is beneficial for expanding the applications of MSAs in thermal management and energy storage.


  • Open Access

    Evaluating Urban Fire Risk Based on Entropy-Cloud Model Method Considering Urban Safety Resilience

    by Minghao Bai, Qiong Liu

    Creating a safe and resilient urban environment is a crucial part of sustainable urban development. Therefore, it is imperative that a city’s safety resilience is evaluated from various perspectives. To evaluate and improve the resilience of urban fire safety more scientifically, this study proposes a theoretical framework for evaluating urban safety resilience based on the triangle model and an index system including fire hazard, regional characteristics, and fire resilience is established. The entropy weight method and cloud model are used for quantitative evaluation, and the weights and risk level ratings are analyzed and discussed. The results demonstrate that the method considering urban safety resilience plays a significant role in promoting the development of urban fire safety and can provide a reference for policymakers in improving fire services.


  • Open Access

    Aramid Pulp Reinforced Clay Aerogel Composites: Mechanical, Thermal and Combustion Behavior

    by Xiaowu Wang, Yang Wang, Mengtian Sun, Guichao Wang, Qiong Liu, Ming Li, Yury M. Shulga, Zhi Li

    In this work, we reported that aramid pulps (AP) reinforced clay aerogel composites with improved mechanical strength, good thermal insulation and fire resistance based on the combination of AP, Poly(vinyl alcohol) (PVA) and sodium montmorillonite (MMT), which present a promising prospect in the thermal insulation application. The PVA-MMT-APx (x: denotes the mass content of AP) aerogel composites present an isotropic “lamella-honeycomb” porous structure, which endows them with excellent comprehensive performance. With the AP content increasing, the extremely low density is kept, ranging between 67–73 mg/cm3, and the low thermal conductivity is maintained within 40.9–47.9 mW·m−1·K−1. The mechanical strength is significantly improved with the maximum compressive modulus increasing from 2.95 to 5.96 MPa and the specific modulus rising from 44.03 to 81.64 MPa∙cm3/g. Their detailed heat transfer process has been analyzed, which provides a deep understanding to the low thermal conductivity of the PVA-MMT-APx aerogel composites. Based on the combination of thermogravimetric analysis and combustion behavior, the PVA-MMT-APx aerogel composites are demonstrated to possess improved thermal stability and fire resistance. This study puts forward a facile approach to utilizing AP to reinforce clay aerogel composites, which provides new insight into the development of thermal-insulating, fire-safe and high-strength thermal insulation materials.