Andreas Staubert
Research Subjects
Andreas Staubert has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Friedrich Albert
Department of Neurosurgery, Heidelberg, Germany
1 shared publicationMario Bonsanto
Department of Neurosurgery, Heidelberg, Germany
1 shared publicationMichael Knauth
Department of Neuroradiology, Ruprecht-Karls-Universität Heidelberg, Heidelberg, Germany
1 shared publicationOtto Pastyr
Institute of Radiology and Pathophysiology, German Cancer Research Center (OKFZ), Heidelberg, Germany
1 shared publicationRainer Wirtz
Department of Neurosurgery, Ruprecht-Karls-Universität Heidelberg, Germany
1 shared publicationStefan Kunze
Department of Neurosurgery, Heidelberg, Germany
1 shared publication
Latest Publications
- 1 October 1998
- Published by Taylor & Francis in Neurological Research
- Vol. 20 (7) , 658-661
Modified headholder and operating table for intra-operative MRI in neurosurgery
In order to facilitate intra-operative use of magnetic resonance imaging (MRI) in neurosurgery an MRIcompatible headholder was developed and adapted to a modified MR-couch simultaneously serving as tabletop for the operating table. To allow shock-free transport into the scanner the wheels of the operating table were replaced by an air cushion mechanism. In 75 procedures the system proved to be reliable and safe. Image quality was not impaired by the fixation device. With growing routine the transfer became straightforward/ requiring approximately 70 min. Intra-operative MRI is thus made possible with minimal changes to the standard surgical environment. Its benefit however/ still remains to be critically investigated. [Neural Res 1998; 20: 658–661]
- 1 October 1998
- Published by Taylor & Francis in Neurological Research
- Vol. 20 (7) , 658-661
Modified headholder and operating table for intra-operative MRI in neurosurgery
In order to facilitate intra-operative use of magnetic resonance imaging (MRI) in neurosurgery an MRIcompatible headholder was developed and adapted to a modified MR-couch simultaneously serving as tabletop for the operating table. To allow shock-free transport into the scanner the wheels of the operating table were replaced by an air cushion mechanism. In 75 procedures the system proved to be reliable and safe. Image quality was not impaired by the fixation device. With growing routine the transfer became straightforward/ requiring approximately 70 min. Intra-operative MRI is thus made possible with minimal changes to the standard surgical environment. Its benefit however/ still remains to be critically investigated. [Neural Res 1998; 20: 658–661]