Evgeniy Degaev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Evgeniy Degaev has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Elena Korol
Moscow State University of Civil Engineering
5 shared publications E.A. Korol
3 shared publicationsIgor Shubin
Research Institute of Building Physics, Moscow, Russia
3 shared publicationsVladimir Rimshin
Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, 129337, Moscow, Russia
3 shared publications- Pierre El Haddad
Saint-Joseph University, Beirut
2 shared publications - Victoria Borkovskaya
Plekhanov Russian University of Economics, Stremyanny lane, 36, 117997, Moscow, Russia
2 shared publications
Latest Publications
- 11 February 2026
- Published by Springer Nature
- p. 345-354
Convergence of Results of Measurements of Dustiness of Workplaces During Special Assessment of Labor Conditions
- 11 February 2026
- Published by Springer Nature
- p. 345-354
Convergence of Results of Measurements of Dustiness of Workplaces During Special Assessment of Labor Conditions
- 1 April 2025
- Published by STC Industry Safety CJSC in Occupational Safety in Industry
- No. 4
Selecting Efficient Surfactants for Dust Suppression during the Production of Crushed Stone
The dust content in the working area during the production of crushed stone remains a key problem for the prevention of occupational illnesses to which 2 % to 12 % of employees are exposed, even when a plant is equipped with modern dust suppression units. The issue of increasing the efficiency of dust suppression with wetting agents has not been addressed yet and requires a comprehensive study of properties and the search for additional factors determining their efficiency. The study aims to select efficient surfactants as wetting agents to suppress dust at a crusher plant. To determine the key factor characterizing the efficiency of dust suppression with wetting agents, comprehensive studies of properties of efficient surfactants have been conducted, including measuring the surface tension at the «solution–air» boundary, the wetting ability, the time of wetting, dust dispersibility, and sprayed solutions. As studies have shown, the surface tension of water solutions plays the key role in the determination of wetting ability, increasing from 70 % to 95 % when the surface tension is reduced from 72.86 mN/m to 26.07 mN/m. Measuring the time of submersion of dust particles into a water solution has detected an exponential dependence on the surface tension; however, the wetting time is reduced by 167–720 times when the surface tension is reduced. The surface tension impacts the interaction between dust particles and the solution of surfactants and the formation of drops during the dispersion, whose dispersibility increases by more than twice. Based on the comprehensive analysis at the crusher plant, wetting agents based on sodium sulfate (C8–C10) or zinc cocosulfate have been recommended for use. The approximation of the obtained data helps to forecast the basic characteristics of wetting agents outlining the efficiency of dust suppression of silica dust. The study results can be used when selecting an efficient wetting agent for dust suppression during production, as well as for manufacturers involved in the development of wetting agent compositions.
- 1 April 2025
- Published by STC Industry Safety CJSC in Occupational Safety in Industry
- No. 4
Selecting Efficient Surfactants for Dust Suppression during the Production of Crushed Stone
The dust content in the working area during the production of crushed stone remains a key problem for the prevention of occupational illnesses to which 2 % to 12 % of employees are exposed, even when a plant is equipped with modern dust suppression units. The issue of increasing the efficiency of dust suppression with wetting agents has not been addressed yet and requires a comprehensive study of properties and the search for additional factors determining their efficiency. The study aims to select efficient surfactants as wetting agents to suppress dust at a crusher plant. To determine the key factor characterizing the efficiency of dust suppression with wetting agents, comprehensive studies of properties of efficient surfactants have been conducted, including measuring the surface tension at the «solution–air» boundary, the wetting ability, the time of wetting, dust dispersibility, and sprayed solutions. As studies have shown, the surface tension of water solutions plays the key role in the determination of wetting ability, increasing from 70 % to 95 % when the surface tension is reduced from 72.86 mN/m to 26.07 mN/m. Measuring the time of submersion of dust particles into a water solution has detected an exponential dependence on the surface tension; however, the wetting time is reduced by 167–720 times when the surface tension is reduced. The surface tension impacts the interaction between dust particles and the solution of surfactants and the formation of drops during the dispersion, whose dispersibility increases by more than twice. Based on the comprehensive analysis at the crusher plant, wetting agents based on sodium sulfate (C8–C10) or zinc cocosulfate have been recommended for use. The approximation of the obtained data helps to forecast the basic characteristics of wetting agents outlining the efficiency of dust suppression of silica dust. The study results can be used when selecting an efficient wetting agent for dust suppression during production, as well as for manufacturers involved in the development of wetting agent compositions.
- Open Access
- 26 December 2024
- Published by National University of Science and Technology MISiS in Mining Science and Technology (Russia)
- Vol. 9 (4) , 395-405
Assessing dust concentration at the workplace of a crushing and screening plant operator for special labor conditions evaluation
Assessing dust concentration at the workplace of a crushing and screening plant operator for special labor conditions evaluation
- 26 December 2024
- Published by National University of Science and Technology MISiS in Mining Science and Technology (Russia)
- Vol. 9 (4) , 395-405
Open AccessAssessing dust concentration at the workplace of a crushing and screening plant operator for special labor conditions evaluation
Assessing dust concentration at the workplace of a crushing and screening plant operator for special labor conditions evaluation
- 1 November 2024
- Published by STC Industry Safety CJSC in Occupational Safety in Industry
- No. 11
Ensuring Safe Working Conditions during Winter Heating of Reinforced Concrete Structures
The high rate of housing construction in 2023 significantly affected the level of occupational electrical injuries due to poor weather conditions and working in the winter season. The risk of electric shock at a construction site crucially increases in winter as heating reinforced concrete structures is mandatory. The study aims to develop design solutions to ensure safe working conditions and electrical safety at a construction site during the heating of reinforced concrete structures in winter. Electrical heating is used for concreting structures when the outdoor air temperature is expected to drop below 5 °C and the minimum daily temperature below 0 °C. The method is applied to prevent the freezing of freshly laid concrete, which can cause the formation of ice films around the reinforcement and filler grains. The study developed design solutions to ensure safe working conditions and electrical safety at a construction site when heating reinforced concrete structures in the winter season. Schemes of safe allocation of electrodes and heating wires in reinforced concrete structures, safe conditions and parameters of the use of heating wires, and safe conditions of structures’ heating and stripping are established. The technology and arrangement of work on installing electrodes and laying heating wires is described, and basic requirements for electrical safety at a construction site when heating reinforced concrete structures in winter are established. During the jobs’ performance, the safety requirements stipulated in the Occupational safety rules must be met. When assembling electrical installations, cables, and wires, the provisions of the Rules for Electrical Installations must be followed, during their operation, the Rules for the Technical Operation of Electrical Installations of Consumers of Electric Energy are applied. Employees must be trained, instructed, and provided with personal protection equipment. The heating area must be equipped with protective fencing, alarms, and safety signs. Electric wires and equipment must be in an operable state, undamaged, and insulated.
- 1 November 2024
- Published by STC Industry Safety CJSC in Occupational Safety in Industry
- No. 11
Ensuring Safe Working Conditions during Winter Heating of Reinforced Concrete Structures
The high rate of housing construction in 2023 significantly affected the level of occupational electrical injuries due to poor weather conditions and working in the winter season. The risk of electric shock at a construction site crucially increases in winter as heating reinforced concrete structures is mandatory. The study aims to develop design solutions to ensure safe working conditions and electrical safety at a construction site during the heating of reinforced concrete structures in winter. Electrical heating is used for concreting structures when the outdoor air temperature is expected to drop below 5 °C and the minimum daily temperature below 0 °C. The method is applied to prevent the freezing of freshly laid concrete, which can cause the formation of ice films around the reinforcement and filler grains. The study developed design solutions to ensure safe working conditions and electrical safety at a construction site when heating reinforced concrete structures in the winter season. Schemes of safe allocation of electrodes and heating wires in reinforced concrete structures, safe conditions and parameters of the use of heating wires, and safe conditions of structures’ heating and stripping are established. The technology and arrangement of work on installing electrodes and laying heating wires is described, and basic requirements for electrical safety at a construction site when heating reinforced concrete structures in winter are established. During the jobs’ performance, the safety requirements stipulated in the Occupational safety rules must be met. When assembling electrical installations, cables, and wires, the provisions of the Rules for Electrical Installations must be followed, during their operation, the Rules for the Technical Operation of Electrical Installations of Consumers of Electric Energy are applied. Employees must be trained, instructed, and provided with personal protection equipment. The heating area must be equipped with protective fencing, alarms, and safety signs. Electric wires and equipment must be in an operable state, undamaged, and insulated.
- 4 May 2024
- Published by Sole Proprietor Company Klyueva M.M. in Construction Materials and Products
- Vol. 7 (3) , 6
The effect of temperature difference on bending of external panel walls
One of the most common structural systems of buildings intended for various purposes is a prefabricated panel system of factory-made elements assembled on-site. Single-layer structures made of lightweight concrete are widely used as envelopes of these buildings. In buildings operated under various climatic conditions, exterior wall panels, as well as other envelopes, are exposed to thermal deformations and, accordingly, changes in the stress-strain state. As the temperature changes, corresponding stresses and deformations occur across the thickness of the exterior panels. To analyze their values, the bending moments and support reactions of single-layer lightweight concrete panels of different length and thickness in the range of temperature differences from 0 °С to 65 °С have been calculated. It was found that the bending moments and support reactions of 1,500 mm long panels decrease as the thickness of the panels increases over the entire temperature gradient. The values of bending moments and support reactions of panels with length of 3,000, 4,500 and 6,000 mm decrease only when the temperature rises from 0 to 10 °С, in the rest of the range 15–65 °С – increase as the thickness of the panel increases due to the bending stiffness.
- 4 May 2024
- Published by Sole Proprietor Company Klyueva M.M. in Construction Materials and Products
- Vol. 7 (3) , 6
The effect of temperature difference on bending of external panel walls
One of the most common structural systems of buildings intended for various purposes is a prefabricated panel system of factory-made elements assembled on-site. Single-layer structures made of lightweight concrete are widely used as envelopes of these buildings. In buildings operated under various climatic conditions, exterior wall panels, as well as other envelopes, are exposed to thermal deformations and, accordingly, changes in the stress-strain state. As the temperature changes, corresponding stresses and deformations occur across the thickness of the exterior panels. To analyze their values, the bending moments and support reactions of single-layer lightweight concrete panels of different length and thickness in the range of temperature differences from 0 °С to 65 °С have been calculated. It was found that the bending moments and support reactions of 1,500 mm long panels decrease as the thickness of the panels increases over the entire temperature gradient. The values of bending moments and support reactions of panels with length of 3,000, 4,500 and 6,000 mm decrease only when the temperature rises from 0 to 10 °С, in the rest of the range 15–65 °С – increase as the thickness of the panel increases due to the bending stiffness.
- Open Access
- 27 February 2024
- Published by FSFEI HE Don State Technical University in Safety of Technogenic and Natural Systems
- No. 1,p. 30-40
Determination of the Convergence of Intra-Laboratory Measurements of Dust Content on a Construction Site
Introduction. Intra-laboratory comparison tests play an important role in ensuring the quality and reliability of research outcomes in laboratories. These tests allow researchers to evaluate the accuracy and reproducibility of the methods they use in their work, as well as to identify potential sources of error and inconsistency. The results of these tests are shared with experts to confirm competence within the accreditation. Typically, comparison tests are carried out in laboratory conditions in a familiar and calm environment for the testers. However, when laboratories conduct research as part of a special assessment of working conditions (SAWC) they are required to conduct on-site comparisons at real-world facilities, where customers may unwittingly disrupt the process and directly affecting the quality of the measurements. The aim of this study is to evaluate the quality of on-site intra-laboratory comparison tests using the example of determining the dust content in a bricklayer's work environment on a construction site, and to determine the minimum number of measurements necessary and sufficient for this purpose.Materials and Methods. To determine the dustiness of the bricklayer's workplace, a weighing method was used. This involved collecting dust on filters and then weighing them to determine the concentration. The quality assessment of intra-laboratory tests was conducted in accordance with GOST R ISO 5725-1-2002 "Accuracy (trueness and precision) of measurement methods and results. Part 1. General principles and definitions".Results. At the bricklayer's workplace, a 1.6-fold excess of the one-time maximum permissible dust concentration was detected. The average dust concentration at the workplace under study was: Kp2 = 9.57 ± 0.81 mg/m3, the convergence of the results obtained was r = 8.68 %, the relative error δ = 8.50 %. It was revealed that the maximum allowable difference between the results of the two tests was 0.84 mg/m3. The difference in direct measurements of the mass of the two samples should be no more than 0.1 mg.Discussion and Conclusion. The results obtained demonstrated the possibility of conducting a minimum number of measurements that, under reproducible conditions, are considered satisfactory and could be provided to experts for confirming the competence of the laboratory. As part of a special assessment of working conditions, employees of the object under study are recommended to use personal respiratory protection equipment that offers protection against highly dispersed dust particles.
- 27 February 2024
- Published by FSFEI HE Don State Technical University in Safety of Technogenic and Natural Systems
- No. 1,p. 30-40
Open AccessDetermination of the Convergence of Intra-Laboratory Measurements of Dust Content on a Construction Site
Introduction. Intra-laboratory comparison tests play an important role in ensuring the quality and reliability of research outcomes in laboratories. These tests allow researchers to evaluate the accuracy and reproducibility of the methods they use in their work, as well as to identify potential sources of error and inconsistency. The results of these tests are shared with experts to confirm competence within the accreditation. Typically, comparison tests are carried out in laboratory conditions in a familiar and calm environment for the testers. However, when laboratories conduct research as part of a special assessment of working conditions (SAWC) they are required to conduct on-site comparisons at real-world facilities, where customers may unwittingly disrupt the process and directly affecting the quality of the measurements. The aim of this study is to evaluate the quality of on-site intra-laboratory comparison tests using the example of determining the dust content in a bricklayer's work environment on a construction site, and to determine the minimum number of measurements necessary and sufficient for this purpose.Materials and Methods. To determine the dustiness of the bricklayer's workplace, a weighing method was used. This involved collecting dust on filters and then weighing them to determine the concentration. The quality assessment of intra-laboratory tests was conducted in accordance with GOST R ISO 5725-1-2002 "Accuracy (trueness and precision) of measurement methods and results. Part 1. General principles and definitions".Results. At the bricklayer's workplace, a 1.6-fold excess of the one-time maximum permissible dust concentration was detected. The average dust concentration at the workplace under study was: Kp2 = 9.57 ± 0.81 mg/m3, the convergence of the results obtained was r = 8.68 %, the relative error δ = 8.50 %. It was revealed that the maximum allowable difference between the results of the two tests was 0.84 mg/m3. The difference in direct measurements of the mass of the two samples should be no more than 0.1 mg.Discussion and Conclusion. The results obtained demonstrated the possibility of conducting a minimum number of measurements that, under reproducible conditions, are considered satisfactory and could be provided to experts for confirming the competence of the laboratory. As part of a special assessment of working conditions, employees of the object under study are recommended to use personal respiratory protection equipment that offers protection against highly dispersed dust particles.
- Open Access
- 31 January 2024
- Published by Moscow State University of Civil Engineering in Vestnik MGSU
- Vol. 19 (1) , 67-76
Анализ эффективности затрат на мероприятия по охране труда
Анализ эффективности затрат на мероприятия по охране труда
- 31 January 2024
- Published by Moscow State University of Civil Engineering in Vestnik MGSU
- Vol. 19 (1) , 67-76
Open AccessАнализ эффективности затрат на мероприятия по охране труда
Анализ эффективности затрат на мероприятия по охране труда
- 1 January 2024
- Published by STC Industry Safety CJSC in Occupational Safety in Industry
- No. 1
Evaluation of the Eficiency of Measures to Improve Working Conditions and Occupational Safety at the Concrete Plants
More than 30 types of raw materials are used in the production of portland cement, which are divided into four main categories: calcium, silica, alumina, iron. Cement dust is toxic and can cause allergies, impaired lung function, pneumoconiosis, lung, stomach and colon cancer. In addition, in winter period, antifreeze additives consisting of various chemicals are added to the concrete mixture. Human exposure to these chemicals occurs through the direct contact of employees with a hazardous substance or indirect contact through the air. As a result, the skin, eyes and respiratory tract may be irritated or damaged. Long-term exposure may cause dermatitis or asthma. In this regard, a concrete plant automation system is considered, built on the basis of modern technical solutions, hardware technologies and software, which allows improving the working conditions of the concrete plant employees. Automation of the technological processes at a concrete plant helps to increase production efficiency and minimize the risks of negative impacts on human health by reducing the number of employees who have direct contact with the cement dust and other chemicals. Considering the parameters: cost savings, return on investment, labor productivity, costs, etc., the economic efficiency of production and measures to improve working conditions and safety was assessed. Efficiency calculation showed that labor productivity increases by 50 %. Automation of the processes allowed, without changingthe production volume, to reduce the number of employees at the site in question by 4 people, ease the work of operators by eliminating the manual control panel, and improve air quality through the installation of carbon filters. With a total one-time cost of 11 200 000 rubles for upgrading equipment, purchasing software and installing carbon filters, the payback period will be 3 years, which proves the high efficiency of capital investments in automating the production processes of a concrete plant.
- 1 January 2024
- Published by STC Industry Safety CJSC in Occupational Safety in Industry
- No. 1
Evaluation of the Eficiency of Measures to Improve Working Conditions and Occupational Safety at the Concrete Plants
More than 30 types of raw materials are used in the production of portland cement, which are divided into four main categories: calcium, silica, alumina, iron. Cement dust is toxic and can cause allergies, impaired lung function, pneumoconiosis, lung, stomach and colon cancer. In addition, in winter period, antifreeze additives consisting of various chemicals are added to the concrete mixture. Human exposure to these chemicals occurs through the direct contact of employees with a hazardous substance or indirect contact through the air. As a result, the skin, eyes and respiratory tract may be irritated or damaged. Long-term exposure may cause dermatitis or asthma. In this regard, a concrete plant automation system is considered, built on the basis of modern technical solutions, hardware technologies and software, which allows improving the working conditions of the concrete plant employees. Automation of the technological processes at a concrete plant helps to increase production efficiency and minimize the risks of negative impacts on human health by reducing the number of employees who have direct contact with the cement dust and other chemicals. Considering the parameters: cost savings, return on investment, labor productivity, costs, etc., the economic efficiency of production and measures to improve working conditions and safety was assessed. Efficiency calculation showed that labor productivity increases by 50 %. Automation of the processes allowed, without changingthe production volume, to reduce the number of employees at the site in question by 4 people, ease the work of operators by eliminating the manual control panel, and improve air quality through the installation of carbon filters. With a total one-time cost of 11 200 000 rubles for upgrading equipment, purchasing software and installing carbon filters, the payback period will be 3 years, which proves the high efficiency of capital investments in automating the production processes of a concrete plant.
- Open Access
- 8 December 2023
- Published by RIOR Publishing Center in Construction and Architecture
- Vol. 11 (4) , 40
ALTERNATIVE PERSONAL PROTECTIVE EQUIPMENT USING END-TO-END TECHNOLOGIES TO ENSURE SAFE WORKING CONDITIONS
- 8 December 2023
- Published by RIOR Publishing Center in Construction and Architecture
- Vol. 11 (4) , 40
Open AccessALTERNATIVE PERSONAL PROTECTIVE EQUIPMENT USING END-TO-END TECHNOLOGIES TO ENSURE SAFE WORKING CONDITIONS
- Open Access
- 8 December 2023
- Published by RIOR Publishing Center in Construction and Architecture
- Vol. 11 (4) , 5
Experimental studies of three-layer wall panels with outer layers of structural concrete and a middle layer of low thermal conductivity concrete
Three-layer wall panels with a thermal insulation layer made of low thermal conductivity concrete are an alternative solution to single-layer structures made of lightweight concrete and three-layer ones with a thermal insulation layer of effective insulation materials, such as polystyrene foam or mineral wool. For them, the basic principles of designing single-layer lightweight concrete panels are retained, including their reinforcement with spatial frames. These wall panels can be used as load-bearing walls of residential buildings, as well as self-supporting and curtain walls of public and industrial buildings. Tests of full-scale wall panel structures were carried out, which revealed and confirmed the reliability of the monolithic connection of layers between different concrete layers at various stages of the structure’s operation, up to destruction.
- 8 December 2023
- Published by RIOR Publishing Center in Construction and Architecture
- Vol. 11 (4) , 5
Open AccessExperimental studies of three-layer wall panels with outer layers of structural concrete and a middle layer of low thermal conductivity concrete
Three-layer wall panels with a thermal insulation layer made of low thermal conductivity concrete are an alternative solution to single-layer structures made of lightweight concrete and three-layer ones with a thermal insulation layer of effective insulation materials, such as polystyrene foam or mineral wool. For them, the basic principles of designing single-layer lightweight concrete panels are retained, including their reinforcement with spatial frames. These wall panels can be used as load-bearing walls of residential buildings, as well as self-supporting and curtain walls of public and industrial buildings. Tests of full-scale wall panel structures were carried out, which revealed and confirmed the reliability of the monolithic connection of layers between different concrete layers at various stages of the structure’s operation, up to destruction.