Artur Miszczuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Artur Miszczuk has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dariusz Heim
Lodz University of Technology
2 shared publications Agnieszka Kaliszuk-Wietecka
Warsaw University of Technology, Faculty of Civil Engineering, Institute of Civil Engineering, Team Building and Sustainable Development Armii Ludowej 16, 00-637 Warsaw, Poland
1 shared publicationBartosz Witkowski
Wroclaw Univ Sci & Technol, Fac Civil Engn, Grobli 15, PL-50421 Wrolaw, Poland
1 shared publicationKazimierz Truchan
Warsaw University of Technology, Faculty of Civil Engineering, Institute of Civil Engineering, Team Building and Sustainable Development Armii Ludowej 16, 00-637 Warsaw, Poland
1 shared publicationSzymon Firląg
Warsaw Univ Technol, Fac Civil Engn, Al Armii Ludowej 16, PL-00637 Warsaw, Poland
1 shared publication- Szymon Firląg
Politechnika Warszawska Wydział Inżynierii Lądowej
1 shared publication
Latest Publications
- Open Access
Optimizing Thermal Comfort with Adaptive Behaviours in South Australian Residential Buildings
This study focuses on thermal comfort in residential buildings within the Iron Triangle area of South Australia, examining how indoor conditions influence residents’ comfort and adaptive behaviours. Conducted from June 2023 to February 2024 across 30 homes in Port Pirie, Port Augusta, and Whyalla, the research gathered data from 38 residents, who reported indoor comfort levels in living rooms and bedrooms. A total of 3540 responses were obtained. At the same time, the measurement of indoor conditions in the buildings was performed using a small HOBO MX1104 device. Using the Mean Thermal Sensation Vote (MTSV) concept, it was possible to determine the neutral operative temperature and temperature ranges for thermal comfort categories. According to the defined linear regression formula, the neutral temperature was 23.9 °C. In living rooms, it was slightly lower, at 23.7 °C, and in bedrooms, slightly higher, at 24.4 °C. For comparison, the neutral temperature was calculated based on the average Predicted Mean Vote (MPMV) and equal to 24.3 °C. Comparison of the regression curves showed that in terms of slope, the MPMV curve is steeper (slope 0.282) than the MTSV curve (slope 0.1726), and lies above it. Regarding the residents’ behaviour, a strong correlation was found between the operative temperature To and the degree of clothing Icl in living rooms. Use of ceiling fans was also studied. A clear trend was also observed regarding window and door opening. The findings of the research can be used to inform the design and operation of residential buildings with a view to enhancing thermal comfort and energy efficiency.
Open AccessOptimizing Thermal Comfort with Adaptive Behaviours in South Australian Residential Buildings
This study focuses on thermal comfort in residential buildings within the Iron Triangle area of South Australia, examining how indoor conditions influence residents’ comfort and adaptive behaviours. Conducted from June 2023 to February 2024 across 30 homes in Port Pirie, Port Augusta, and Whyalla, the research gathered data from 38 residents, who reported indoor comfort levels in living rooms and bedrooms. A total of 3540 responses were obtained. At the same time, the measurement of indoor conditions in the buildings was performed using a small HOBO MX1104 device. Using the Mean Thermal Sensation Vote (MTSV) concept, it was possible to determine the neutral operative temperature and temperature ranges for thermal comfort categories. According to the defined linear regression formula, the neutral temperature was 23.9 °C. In living rooms, it was slightly lower, at 23.7 °C, and in bedrooms, slightly higher, at 24.4 °C. For comparison, the neutral temperature was calculated based on the average Predicted Mean Vote (MPMV) and equal to 24.3 °C. Comparison of the regression curves showed that in terms of slope, the MPMV curve is steeper (slope 0.282) than the MTSV curve (slope 0.1726), and lies above it. Regarding the residents’ behaviour, a strong correlation was found between the operative temperature To and the degree of clothing Icl in living rooms. Use of ceiling fans was also studied. A clear trend was also observed regarding window and door opening. The findings of the research can be used to inform the design and operation of residential buildings with a view to enhancing thermal comfort and energy efficiency.
- Open Access
- 30 June 2023
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 69 (2) , 195-209
Analysis of climate change and its potential influence on energy performance of building and indoor temperatures. Part 2: Energy and thermal simulation
- 30 June 2023
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 69 (2) , 195-209
Open AccessAnalysis of climate change and its potential influence on energy performance of building and indoor temperatures. Part 2: Energy and thermal simulation
- Open Access
Parametric Study of Air Infiltration in Residential Buildings—The Effect of Local Conditions on Energy Demand
Airtightness is nowadays one of the physical parameters which determine overall building energy performance. In a wide range of states, the upper limit for air change rate at a Pa (na), air permeability rate at a Pa (qa), or specific leakage rate at a Pa (wa) is determined by the formal regulations. It should be highlighted that airtightness requirements are mainly the same around the world, disregarding any site and climatic conditions. The main goal of the presented work was to reveal the effect of individual location and surrounding infiltration rate and heat demand. The analyses were done using numerical techniques and computational models of the three buildings developed and calibrated based on the blower door test results. The compared buildings characterize by a similar geometry but differ in the air change rate at 50 Pa (n50). Analyses done for different locations and levels of sheltering by surrounding elements allow the determination of the real effect of local conditions. The obtained differences in energy demand between two locations from the same climatic zone were from 70% to 90%, depending on the airtightness of the buildings. Considering different sheltered conditions, the differences for the same location can be even 200%. The obtained results allowed for the formulation of the general conclusion that building location and level of exposure could be considered in future airtightness regulations.
Open AccessParametric Study of Air Infiltration in Residential Buildings—The Effect of Local Conditions on Energy Demand
Airtightness is nowadays one of the physical parameters which determine overall building energy performance. In a wide range of states, the upper limit for air change rate at a Pa (na), air permeability rate at a Pa (qa), or specific leakage rate at a Pa (wa) is determined by the formal regulations. It should be highlighted that airtightness requirements are mainly the same around the world, disregarding any site and climatic conditions. The main goal of the presented work was to reveal the effect of individual location and surrounding infiltration rate and heat demand. The analyses were done using numerical techniques and computational models of the three buildings developed and calibrated based on the blower door test results. The compared buildings characterize by a similar geometry but differ in the air change rate at 50 Pa (n50). Analyses done for different locations and levels of sheltering by surrounding elements allow the determination of the real effect of local conditions. The obtained differences in energy demand between two locations from the same climatic zone were from 70% to 90%, depending on the airtightness of the buildings. Considering different sheltered conditions, the differences for the same location can be even 200%. The obtained results allowed for the formulation of the general conclusion that building location and level of exposure could be considered in future airtightness regulations.
- 10 February 2020
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 41 (6) , 681-693
Modelling building infiltration using the airflow network model approach calibrated by air-tightness test results and leak detection
This paper presents a computational approach to air infiltration modelling and simulation validated by the blower door test results. In order to evaluate the potential of the airflow network method, three simulation models of the infiltration test were developed and calibrated by field measurements of leaked air change rate per hour at 50 Pa. Models were developed for existing building designs and constructed in low-energy standards differing in construction type and tightness. All leaks were precisely measured during field tests, defined as openings or cracks, numerically described and included in the model. The simulation results of calibrated models for other pressure differences revealed that the models’ accuracy is satisfactory. The differences between field tests and simulation results do not exceed 2.5%. Additionally, the calibrated models were used to estimate the infiltration heat losses of buildings in three different locations under continental climatic conditions. The results were compared with the steady-state method calculations made for the same building models and climatic conditions. It was proved that the steady-state method gives higher results of heat demand to cover infiltration losses than the simulation method. The final results depend on building location and vary between four and nine times. Practical application: The computational modelling and building performance simulations are increasingly commonly used in engineering design. The proposed method of air-tightness modelling and calibration can be used at any phase of a building’s lifecycle, from design and construction to exploitation and maintenance. Using the proposed techniques, it is possible to estimate more realistic processes of air infiltration and its effect on a building’s energy consumption in comparison with the steady-state method. Moreover, the analysis includes the dynamic effect of boundary conditions (external air temperature, wind speed and direction), as well as the effects of the building site and the surroundings.
- 10 February 2020
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 41 (6) , 681-693
Modelling building infiltration using the airflow network model approach calibrated by air-tightness test results and leak detection
This paper presents a computational approach to air infiltration modelling and simulation validated by the blower door test results. In order to evaluate the potential of the airflow network method, three simulation models of the infiltration test were developed and calibrated by field measurements of leaked air change rate per hour at 50 Pa. Models were developed for existing building designs and constructed in low-energy standards differing in construction type and tightness. All leaks were precisely measured during field tests, defined as openings or cracks, numerically described and included in the model. The simulation results of calibrated models for other pressure differences revealed that the models’ accuracy is satisfactory. The differences between field tests and simulation results do not exceed 2.5%. Additionally, the calibrated models were used to estimate the infiltration heat losses of buildings in three different locations under continental climatic conditions. The results were compared with the steady-state method calculations made for the same building models and climatic conditions. It was proved that the steady-state method gives higher results of heat demand to cover infiltration losses than the simulation method. The final results depend on building location and vary between four and nine times. Practical application: The computational modelling and building performance simulations are increasingly commonly used in engineering design. The proposed method of air-tightness modelling and calibration can be used at any phase of a building’s lifecycle, from design and construction to exploitation and maintenance. Using the proposed techniques, it is possible to estimate more realistic processes of air infiltration and its effect on a building’s energy consumption in comparison with the steady-state method. Moreover, the analysis includes the dynamic effect of boundary conditions (external air temperature, wind speed and direction), as well as the effects of the building site and the surroundings.
- Open Access
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 661 (1) , 012143
Plasters on Facades, and the Possibility of Inter-layer Condensation
The publication focuses on what happened outside, on the possibilities and condensation of water vapor. The first part presents the advantages and disadvantages of plasters and the hazards resulting from the condensation of water vapor. To formulate conclusions, analyzes of various thermal insulation materials and external plasters were carried out. The obtained results indicate that the types and thickness of individual materials used in the wall affect the possibility of condensation of water vapor inside the building envelope.
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 661 (1) , 012143
Open AccessPlasters on Facades, and the Possibility of Inter-layer Condensation
The publication focuses on what happened outside, on the possibilities and condensation of water vapor. The first part presents the advantages and disadvantages of plasters and the hazards resulting from the condensation of water vapor. To formulate conclusions, analyzes of various thermal insulation materials and external plasters were carried out. The obtained results indicate that the types and thickness of individual materials used in the wall affect the possibility of condensation of water vapor inside the building envelope.
- Open Access
- 3 September 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 196, 04049
The influence of construction and material solutions on the level of air tightness in single energy buildings
This publication focuses on the assessment of the impact of structural solutions of single-family buildings with an increased energy standard on their air-tightness level. The first part presents the threats resulting from the low tightness of the building. To formulate the conclusions, quantitative and qualitative casing tightness tests of existing single-family energy-efficient buildings were carried out. Construction and material solutions used in buildings were also analysed. The obtained results indicate that there is no impact of the building structure on its level of air tightness.
- 3 September 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 196, 04049
Open AccessThe influence of construction and material solutions on the level of air tightness in single energy buildings
This publication focuses on the assessment of the impact of structural solutions of single-family buildings with an increased energy standard on their air-tightness level. The first part presents the threats resulting from the low tightness of the building. To formulate the conclusions, quantitative and qualitative casing tightness tests of existing single-family energy-efficient buildings were carried out. Construction and material solutions used in buildings were also analysed. The obtained results indicate that there is no impact of the building structure on its level of air tightness.
- Open Access
- 24 July 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 117, 00120
Influence of air tightness of the building on its energy-efficiency in single-family buildings in Poland
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
- 24 July 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 117, 00120
Open AccessInfluence of air tightness of the building on its energy-efficiency in single-family buildings in Poland
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
- Open Access
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 153, 461-466
The Level of Airtightness in Energy-efficient Single-family Houses in Poland
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 153, 461-466
Open AccessThe Level of Airtightness in Energy-efficient Single-family Houses in Poland
- 5 January 2015
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (1) , 26-29
Analiza budynk w o niskim zapotrzebowaniu na energi
- 5 January 2015
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in MATERIAŁY BUDOWLANE
- Vol. 1 (1) , 26-29
Analiza budynk w o niskim zapotrzebowaniu na energi