IPIsaratat Phung-On

Isaratat Phung-On

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Isaratat Phung-On has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-temperature stability of h-BN thin films on AISI 304 stainless steel from atmospheric glazing process

    by Prathumrat Nuyang, Isaratat Phung-On, Somporn Peansukmanee, Chatree Saiyasombat, Pat Photongkam, Thipusa Wongpinij

    Hexagonal boron nitride (h-BN) is widely recognized for its exceptional thermal and chemical stability, making it a promising protective coating for metallic substrates operating in harsh environments. Although atmospheric-glazed h-BN coatings have previously been demonstrated to enhance the corrosion resistance of stainless steel, their thermally induced structural evolution, and high-temperature stability have not yet been systematically elucidated. In this study, h-BN thin films were fabricated on electropolished (EP) AISI 304 stainless steel via an atmospheric glazing process at growth temperatures of 300 °C and 475 °C. By integrating semi in situ synchrotron grazing-incidence wide-angle x -ray scattering (GIWAXS), x -ray photoelectron spectroscopy (XPS), near-edge x -ray absorption fine structure (NEXAFS), and electrochemical analyses, this study establishes the relationship between thermal structural stability and corrosion protection. Atomic force microscopy (AFM) revealed a uniform and continuous h-BN coating with an average thickness of approximately 40 nm. Thermal structural evolution and stability were investigated using semi in situ GIWAXS. The results showed that the film grown at 475 °C retained its crystallinity and structural integrity upon heating to 900 °C, demonstrating remarkable thermal stability. XPS and NEXAFS confirmed the formation of a highly ordered stoichiometric sp 2 -hybridized B–N network. Electrochemical impedance spectroscopy (EIS) showed that the improved structural ordering enhanced dielectric behavior and reduced defect density, indicating the formation of a dense and stable coating. The film prepared at 475 °C exhibited a high pitting potential ( E pit = 1.662 ± 0.003 V) and a low corrosion rate of 0.918 ± 0.001 MPY. These findings provide new insight into the structure–property relationship of atmospheric-glazed h-BN coatings, demonstrating that their superior corrosion resistance originates from the formation of a thermally stable crystalline framework and a chemically robust sp 2 -bonded B–N network on EP stainless steel.

  • Open Access

    Evaluation of pulsed and standard gas metal arc welding waveforms for energy efficiency and carbon mitigation in automotive assembly: a systemic industrial approach

    by Isaratat Phung-On, Napongphan Traiyapanich, Kritsada Naksawat, Thammarak Sodarak, Somporn Peansukmanee

    The automotive industry is transiting toward carbon neutrality. Optimizing energy intensive manufacturing processes like gas metal arc welding (GMAW) has become an important aspect. This research provides a multi-dimensional comparative analysis of standard current and pulsed current waveforms for welding Steel Plate Cold Commercial cold-rolled steel (1.2 mm and 2.8 mm thickness), specifically evaluating their contribution to energy consumption, productivity, and Scope 2 carbon emissions. All tested configurations were validated for structural integrity conforming to American Welding Society (AWS) D1.3 standards. There were 7 types of welding in this study, but only 5 types could be passed conforming to AWS D1.3 requirements. The time study was implemented to determine Standard Time which considered rating factors and industrial allowances. Power measurement was performed for both input and output sides of welding machine. Results for 1.2 mm thin-gauge specimen showed that pulsed current welding reduced unit energy consumption and carbon emissions by 14.26% compared to Standard current welding. For 2.8 mm specimen, a ‘Productivity Paradox’ was identified: while the pulsed current welding required higher peak power, its character to achieve complete joint penetration in a single-pass with square butt configuration that eliminated the requirement for the V-groove preparation and double-sided welding required by the standard current welding. This led to a 59.89% reduction in Standard Time and a 58.87% decrease in total operational costs. By estimating annual impact for producing 100 000 units, switching to Pulsed GMAW with 180 000 THB investment would pay back within 5.793 months through energy and labor-saving providing a compelling economic benefit for manufacturers to invest in and implementing pulsed current welding machines on the production floor. The findings confirm that pulsed current welding could provide pathways for compliance with reduction of carbon emissions with low capital expense strategy for achieving ‘Green Industry’ objectives in high-volume automotive production.

  • Open Access

    Creep life fraction assessment of 9Cr–1Mo–V steel using direct current potential drop technique

    by Karn Kankanok, Isaratat Phung-On, Chettapong Janya-Anurak, Cherdpong Jomdecha, Montri Charoenlapvichayo

    This study investigates the use of direct current potential drop (DCPD) measurements as a predictive tool for assessing creep life fractions in 9Cr–1Mo–V (P91) steel exposed to high-temperature and high-stress conditions. To optimize predictive reliability, the data analysis strategically focused on the mechanistically stable 20%–80% creep life fraction window. The continuous DCPD signals within this range were analyzed using machine learning-based regression models. These refined models achieved high predictive accuracy, yielding an average mean absolute percentage error of 8.14% for quadratic regression and 8.29% for linear regression. Furthermore, microstructural evolution was characterized through carbide precipitation using the on-site extraction replica technique, with an emphasis on the Cr/Fe ratio as a primary indicator of creep damage. Distinct DCPD signal patterns were identified across the creep stages: initial transient fluctuations during the primary stage, a steady decline in the secondary stage due to matrix purification, and a sharp increase in the tertiary stage driven by internal damage. These responses were strongly correlated with carbide precipitation and coarsening induced by prolonged stress exposure. Integrating DCPD with microstructural analysis provides a robust, non-destructive framework for assessing creep damage. This combined approach offers practical insights for the design and health monitoring of high-temperature components, supporting structural integrity and lifetime management in power plants and other critical applications.

  • Possibility of Using Direct Current Potential Drop for Stress Corrosion Cracking Life Assessment

    by Noppakorn Phuraya, Phornkamol Navasalao, Picha Panmongkol, Isaratat Phung-On

  • Open Access

    Enhanced Corrosion Resistance of AISI 304 Stainless Steel via Atmospheric Glazing of Boron Nitride Thin Films

    by Prathumrat Nuyang, Isaratat Phung-On, Somporn Peansukmanee, Paiboon Choungthong, Chatree Saiyasombat

    Conventional synthesis of protective boron nitride (BN) films typically relies on high-vacuum systems, rendering them unsuitable for on-site maintenance of stainless steel infrastructure. To address this limitation, this study proposes a facile atmospheric glazing technique utilizing a boron-rich precursor to fabricate BN films on AISI 304 stainless steel under ambient pressure. The films were thermally grown at varying temperatures to determine optimal growth conditions. Structural characterization using grazing-incidence wide-angle X-ray scattering (GIWAXS), high-resolution transmission electron microscopy (HRTEM), and Raman spectroscopy confirmed the successful formation of polycrystalline h-BN layers with uniform spatial distribution. The results demonstrated that the film processed at 475 °C yielded superior surface properties, achieving a hydrophobic water contact angle (WCA) of 96.2° and a low average surface roughness (Ra) of 0.24 μm. Electrochemical testing revealed a significant enhancement in corrosion resistance; the pitting potential (Epit) increased to 1.738 Volts (an improvement of 0.841 Volts over the as-received substrate), while the corrosion rate decreased by 92.16%. These findings suggest that this low-temperature, atmospheric glazing process offers a practical and scalable alternative for applying corrosion-resistant h-BN coatings in field repair and industrial maintenance applications.


  • Open Access

    Magnetic properties and electron oxidation state transition of immunomagnetic nanoparticles specifically captured with the target bacteria

    by Chalermkiat Jirarungsatian, Pravate Tuitemwong, Isaratat Phung-On, Yingyot Poo-Arporn, Sirirat Wachiralurpan

    Immunomagnetic nanoparticles (IMNPs) have been widely applied for the capture and concentration in the rapid detection of target bacteria. In this research, the focus was on studying the changes in magnetic properties changes of the IMNPs when they were attached to bacterial cells. These alterations in properties could facilitate an even rapid detection of the target bacteria and eliminate the need for culturing on plating media. The variation of magnetizing values, including saturated magnetization (Ms), remanent magnetization (Mr), coercivity force (Hc), and magnetic susceptibility (χm), was analysed through M-H loops. It was observed that the magnetizing properties of the IMNPs underwent changes based on the concentrations of Salmonella Typhimurium cells in the test solution. The correlation of this phenomenon was confirmed by the results of synchrotron x-ray absorption spectroscopy (XAS), which revealed electronic transition changes in the IMNPs after capturing the bacteria cells. Additionally, the electronic bands of the magnetite nanoparticle [Fe(II) and Fe(III)] were detected, indicating an electronic transformation between the Salmonella cells and the bound IMNPs. The XAS change was further verified using different cell types, such as Campylobacter jejuni which also showed electronic transformation after attaching to IMNPs. These findings suggest that IMNP-cell attachment triggered the change in the magnetic properties of IMNPs. Such insights could serve as valuable information for the development of novel rapid bacteria detection assays/devices using magnetic sensing techniques.


  • Open Access

    Study of imitative micro pit morphology evaluation

    by Picha Panmongkol, Catleya Rojviriya, Isaratat Phung-On

    This study examined the imitative micro pit formation of pitting corrosion on 304 stainless steel under electrochemical control in a 3.0% NaCl solution. Results demonstrated that the micro pits changed from a conical to a cap shape during growth, indicating that their evolution in shape and growth did not follow the same morphology over time. Additionally, the piecewise polynomial method was employed to compare real-time micro pit growth morphology evolution with current density, which was consistent with cross-sectional images of actual micro pits, enabling the separation of the pitting corrosion stages. Furthermore, 3D images obtained from SRXTM were similar to cross-sectional images of real micro pits, further validating the technique’s usefulness in studying micro pits.


  • Open Access

    In-Situ Monitoring of Real-Time Loop-Mediated Isothermal Amplification with QCM: Detecting Listeria monocytogenes

    by Sirirat Wachiralurpan, Isaratat Phung-On, Narong Chanlek, Supatra Areekit, Kosum Chansiri, Peter A. Lieberzeit

    Functionalized DNA sequences are promising sensing elements to combine with transducers for bio-sensing specific target microbes. As an application example, this paper demonstrates in situ detection of loop-mediated isothermal amplification products by hybridizing them with thiolated-ssDNA covalently anchored on the electrodes of a quartz crystal microbalance (QCM). Such hybridization leads to a frequency signal, which is suitable for monitoring real-time LAMP amplification based on mass-sensing: it detects interactions between the complementary nucleobases of LAMP products in solution and the thiolated-ssDNA probe sequence on the gold surface. Target DNA LAMP products cause irreversible frequency shifts on the QCM surfaces during hybridization in the kHz range, which result from both changes in mass and charge on the electrode surface. In order to confirm the LAMP assay working in the QCM sensing system at elevated temperature, the sky blue of positive LAMP products solution was achieved by using the Hydroxy Naphthol Blue (HNB) and agarose gel electrophoresis. Since on-QCM sensing of DNA hybridization leads to irreversible sensor responses, this work shows characterization by X-ray photoelectron spectroscopy (XPS) core spectra of S2p, N1s, Mg1s, P2p and C1s. XPS results confirmed that indeed both DNA and by-products of LAMP attached to the surface. Listeria monocytogenes DNA served to study in-situ detection of amplified LAMP products on DNA-functionalized surfaces.