GSGustavo Sipp

Gustavo Sipp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gustavo Sipp has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Compression Strength of Thin Joint Masonry with Polymeric Mortar

    by G. A. Parsekian, G. Sipp, L. Bressiani, A. P. Margarido

  • Open Access

    Considerações sobre alvenaria estrutural com junta fina de argamassa polimérica

    by Gustavo Sipp, Lucia Bressiani, Ana Paula Margarido, Guilherme Aris Parsekian

    Este trabalho apresenta as principais considerações obtidas de uma pesquisa sobre o comportamento da alvenaria estrutural de blocos de concreto, construída com juntas de assentamento finas de composto polimérico. Alvenaria estrutural com junta fina é empregada há alguns anos na Europa, mas não existem normas destinadas ao projeto de alvenaria estrutural com juntas finas de compostos poliméricos. A pesquisa contemplou a realização de ensaios de caracterização de todos os materiais, além dos ensaios de resistência a compressão, flexão e cisalhamento da alvenaria e a avaliação de aspectos construtivos. Desta forma, neste trabalho são apresentadas as principais ponderações obtidas com as análises dos resultados da pesquisa realizada, com o objetivo de aperfeiçoar os métodos utilizados, nortear outras pesquisas na área e nortear especificações para projeto e execução desse tipo de sistema construtivo. São feitas recomendações quanto ao tempo de cura e idade mínima para execução do revestimento, preenchimento da junta vertical, considerações sobre variações nas propriedades físicas e mecânicas do composto polimérico e ensaios para avaliá-los, uso de cunhas para assentamento, relações de resistência entre diferentes tipos de corpos-de-prova. Sugere-se limitar uma possível nova norma à execução de casas e sobrados.

  • Open Access

    Resistência à tração na flexão para alvenaria estrutural de blocos de concreto, executada com juntas finas de composto polimérico: métodos de ensaio

    by Gustavo Sipp, Murilo de Carvalho Maturana, Lucia Bressiani, Guilherme Aris Parsekian

    Este trabalho avalia a resistência à tração na flexão para a alvenaria estrutural de blocos de concreto, executada com juntas finas de composto polimérico. Para isso, foram realizados ensaios por meio da NBR 16868-3 (2020) e AS 3700 (2017), para prismas com blocos de concreto de 4, 8 e 16 MPa, considerando argamassa cimentícia e composto polimérico. Os resultados mostram que os valores de resistência a tração na flexão são maiores para compostos poliméricos. Quando foram comparados os dois ensaios, constatou-se que os dados obtidos por meio da norma australiana são maiores que os obtidos com o ensaio da norma brasileira.

  • Open Access

    Investigation of the adherence between clay blocks and grouts

    by Gustavo Sipp, Guilherme Aris Parsekian

    This study aims to evaluate the adherence between clay blocks and grouts. For this purpose, push-out and pull-out tests were performed to assess the adherence presented by different combinations of five types of clay blocks and two types of grouts. The results demonstrated that the geometry of the cells of the clay blocks has a preponderant role in their adherence with grout, as the extent of the contact area between grout and block depends on the geometry of the cell. The shrinkage of the grout can cause the formation of cracks at the interface between block and grout, reducing the adherence between the materials. The shrinkage formed inside each type of block can be estimated based on the testing procedure developed in this research and used in conjunction with the geometric characteristics of the cells of the blocks to estimate the maximum load in the push-out tests. The test procedure developed to estimate the percentage of contact area lost due to grouts shrinkage shows to be promising, since its results were used in the equation to estimate the bond strength between blocks and grouts and shown good correlation. However, more study must be done because there are other variables that can affect the results. These results show that it is possible to use different characteristics of blocks and grouts to increase the adherence between these materials and provide a better behavior for reinforced masonry structures. However, it looks like if block types with a grooved hollow cell are used, a bigger contact surface is produced, and a higher bond strength appears to be assured.


  • High‐rise concrete and clay block masonry building in Brazil

    by Guilherme Aris Parsekian, Wallison Angelim Medeiros, Gustavo Sipp


  • Open Access

    Investigation of the influence of different surface regularization methods for cylindrical concrete specimens in axial compression tests

    by R. Medeiros, B. A. Pereira, G. Sipp, T. Delfino

    This study was conducted with the aim of evaluating the influence of different methods for end surface preparation of compressive strength test specimens. Four different methods were compared: a mechanical wear method through grinding using a diamond wheel established by NBR 5738; a mechanical wear method using a diamond saw which is established by NM 77; an unbonded system using neoprene pads in metal retainer rings established by C1231 and a bonded capping method with sulfur mortar established by NBR 5738 and by NM 77. To develop this research, 4 concrete mixes were determined with different strength levels, 2 of group 1 and 2 of group 2 strength levels established by NBR 8953. Group 1 consists of classes C20 to C50, 5 in 5MPa, also known as normal strength concrete. Group 2 is comprised of class C55, C60 to C100, 10 in 10 MPa, also known as high strength concrete. Compression tests were carried out at 7 and 28 days for the 4 surface preparation methods. The results of this study indicate that the method established by NBR 5738 is the most effective among the 4 strengths considered, once it presents lower dispersion of values obtained from the tests, measured by the coefficient of variation and, in almost all cases, it demonstrates the highest mean of rupture test. The method described by NBR 5738 achieved the expected strength level in all tests.