Yuki Uchida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuki Uchida has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
E. Takada
National Institute of Technology, Toyama College, 13 Hongo-mach, Toyama 939-8630, Japan
3 shared publicationsKazumasa Takahashi
Nagaoka University of Technology
3 shared publicationsSeiki Saito
3 shared publicationsTakashi Kikuchi
Nagaoka University of Technology
3 shared publicationsTsuneo Suzuki
3 shared publicationsA. Fujisaki
National Institute of Technology, Toyama College, 13 Hongo-mach, Toyama 939-8630, Japan
2 shared publications
Latest Publications
- 6 July 2026
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (10) , 1097-1100
A simple formulation of heat flux factor for transient heat loads
1. Transient heat loads such as edge localized modes (ELMs) and plasma disruptions cause thermal shocks on plasma-facing materials in magnetic confinement fusion systems [1–4]. These events can cau...
- 6 July 2026
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (10) , 1097-1100
A simple formulation of heat flux factor for transient heat loads
1. Transient heat loads such as edge localized modes (ELMs) and plasma disruptions cause thermal shocks on plasma-facing materials in magnetic confinement fusion systems [1–4]. These events can cau...
- 26 December 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 211
Observation of greater blister skin thickness compared with the implantation depth of high-energy helium in tungsten
- 26 December 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 211
Observation of greater blister skin thickness compared with the implantation depth of high-energy helium in tungsten
- Open Access
Preliminary Verification of the PHITS Code Applicability to Conversion Efficiency Calculation of Direct Charge Nuclear Battery
A direct charge nuclear battery, or DCNB, is one of the nuclear batteries based on direct energy conversion and is characterized by exceptional high voltage generation and conversion efficiency higher than other nuclear batteries. For studying potential applications of DCNB, a preliminary estimation of DCNB electrical power and performance is required; hence, conversion efficiency analysis is crucial. For preliminary verification purposes, an ideal DCNB conversion efficiency was calculated under the simplified electron transport model by using the general-purpose Monte Carlo particle transport calculation code PHITS. The result was compared with a reference experimental efficiency for a T-loaded parallel plate DCNB, and the resulting relative error was approximately 12%. Considering the relative error of 20% or less in DCNB conversion efficiency shown by preceding studies, the resulting error was comparable, and it was concluded that the PHITS code is sufficiently applicable to DCNB conversion efficiency analysis.
Open AccessPreliminary Verification of the PHITS Code Applicability to Conversion Efficiency Calculation of Direct Charge Nuclear Battery
A direct charge nuclear battery, or DCNB, is one of the nuclear batteries based on direct energy conversion and is characterized by exceptional high voltage generation and conversion efficiency higher than other nuclear batteries. For studying potential applications of DCNB, a preliminary estimation of DCNB electrical power and performance is required; hence, conversion efficiency analysis is crucial. For preliminary verification purposes, an ideal DCNB conversion efficiency was calculated under the simplified electron transport model by using the general-purpose Monte Carlo particle transport calculation code PHITS. The result was compared with a reference experimental efficiency for a T-loaded parallel plate DCNB, and the resulting relative error was approximately 12%. Considering the relative error of 20% or less in DCNB conversion efficiency shown by preceding studies, the resulting error was comparable, and it was concluded that the PHITS code is sufficiently applicable to DCNB conversion efficiency analysis.
- 16 September 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 123 (40) , 24584-24591
Thermostable Rh Metal Nanoparticles Formed on Al2O3 by High-Temperature H2 Reduction and Its Impact on Three-Way Catalysis
- 16 September 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 123 (40) , 24584-24591
Thermostable Rh Metal Nanoparticles Formed on Al2O3 by High-Temperature H2 Reduction and Its Impact on Three-Way Catalysis
- 10 July 2018
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 13, 1205084
Blister Formation on Tungsten Irradiated by 4 MeV Helium Ion Beam in Ordinary Temperature
Blistering was observed on surface of polycrystalline tungsten samples irradiated by helium ion beams with 4 MeV kinetic energy in a fluence of 1022 m−2. The helium ion beam was used as the damage source to the tungsten plate, and the surface temperature of tungsten sample was increased up to 345 K by the ion beam irradiation. The surface was modified by the ion beam irradiation, and its maximum height was about 20 µm.
- 10 July 2018
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 13, 1205084
Blister Formation on Tungsten Irradiated by 4 MeV Helium Ion Beam in Ordinary Temperature
Blistering was observed on surface of polycrystalline tungsten samples irradiated by helium ion beams with 4 MeV kinetic energy in a fluence of 1022 m−2. The helium ion beam was used as the damage source to the tungsten plate, and the surface temperature of tungsten sample was increased up to 345 K by the ion beam irradiation. The surface was modified by the ion beam irradiation, and its maximum height was about 20 µm.
- Open Access
- 1 December 2017
- Published by Elsevier in Energy Procedia
- Vol. 131, 359-362
Experiment and measurement with high-energy helium irradiation to tungsten using tandem accelerator for divertor in magnetic confinement fusion system
- 1 December 2017
- Published by Elsevier in Energy Procedia
- Vol. 131, 359-362
Open AccessExperiment and measurement with high-energy helium irradiation to tungsten using tandem accelerator for divertor in magnetic confinement fusion system
- 1 August 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (8) , 083504
Probabilistic n/γ discrimination with robustness against outliers for use in neutron profile monitors
A method to stochastically discriminate neutron and γ-ray signals measured with a stilbene organic scintillator is proposed. Each pulse signal was stochastically categorized into two groups: neutron and γ-ray. In previous work, the Expectation Maximization (EM) algorithm was used with the assumption that the measured data followed a Gaussian mixture distribution. It was shown that probabilistic discrimination between these groups is possible. Moreover, by setting the initial parameters for the Gaussian mixture distribution with a k-means algorithm, the possibility of automatic discrimination was demonstrated. In this study, the Student’s t-mixture distribution was used as a probabilistic distribution with the EM algorithm to improve the robustness against the effect of outliers caused by pileup of the signals. To validate the proposed method, the figures of merit (FOMs) were compared for the EM algorithm assuming a t-mixture distribution and a Gaussian mixture distribution. The t-mixture distribution resulted in an improvement of the FOMs compared with the Gaussian mixture distribution. The proposed data processing technique is a promising tool not only for neutron and γ-ray discrimination in fusion experiments but also in other fields, for example, homeland security, cancer therapy with high energy particles, nuclear reactor decommissioning, pattern recognition, and so on.
- 1 August 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (8) , 083504
Probabilistic n/γ discrimination with robustness against outliers for use in neutron profile monitors
A method to stochastically discriminate neutron and γ-ray signals measured with a stilbene organic scintillator is proposed. Each pulse signal was stochastically categorized into two groups: neutron and γ-ray. In previous work, the Expectation Maximization (EM) algorithm was used with the assumption that the measured data followed a Gaussian mixture distribution. It was shown that probabilistic discrimination between these groups is possible. Moreover, by setting the initial parameters for the Gaussian mixture distribution with a k-means algorithm, the possibility of automatic discrimination was demonstrated. In this study, the Student’s t-mixture distribution was used as a probabilistic distribution with the EM algorithm to improve the robustness against the effect of outliers caused by pileup of the signals. To validate the proposed method, the figures of merit (FOMs) were compared for the EM algorithm assuming a t-mixture distribution and a Gaussian mixture distribution. The t-mixture distribution resulted in an improvement of the FOMs compared with the Gaussian mixture distribution. The proposed data processing technique is a promising tool not only for neutron and γ-ray discrimination in fusion experiments but also in other fields, for example, homeland security, cancer therapy with high energy particles, nuclear reactor decommissioning, pattern recognition, and so on.
- Open Access
- 12 August 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 11E118
A study on fast digital discrimination of neutron and gamma-ray for improvement neutron emission profile measurement
Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was applied using the EM algorithm and k-means algorithm.
- 12 August 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 11E118
Open AccessA study on fast digital discrimination of neutron and gamma-ray for improvement neutron emission profile measurement
Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was applied using the EM algorithm and k-means algorithm.
- 22 July 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 11E110
Progress in development of the neutron profile monitor for the large helical device
The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 105 counts per second.
- 22 July 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 11E110
Progress in development of the neutron profile monitor for the large helical device
The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 105 counts per second.