XLXiang Li

Xiang Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiang Li has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Haibing Hu

    Jiangsu Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing, China

    8 shared publications
  • Daorong Lu

    School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, China

    6 shared publications
  • Liuniu Guo

    College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China

    3 shared publications
  • Yan Xing

    Center for More-Electric-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China

    3 shared publications
  • Miaoyu Wei

    Jiangsu Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing, China

    2 shared publications
  • Tianchen Lang

    College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China

    2 shared publications

Latest Publications

  • Power Sharing Control Strategy of ISOP LLC-DAB Hybrid Bidirectional Converters Based on Multiagent Consensus Theory

    by Yuefeng Liao, Zhenkun Yang, Duo Yang, Xiang Li, Guo Xu, Jing Liang

    In applications such as dc microgrids and energy storage systems that are characterized by high power and input voltage, input-series output-parallel (ISOP) dc-dc bidirectional converters are widely adopted to intermediate power conversion. The LLC-DAB hybrid bidirectional converter is a single-stage converter, which is composed of LLC resonant circuit and dual active bridge (DAB) circuit. It combines the advantages of LLC and DAB, making it highly suitable for use as a submodule (SM). However, differences in input impedance among these SMs can lead to power imbalance during operation, affecting the performance of the system. To address this problem, a novel power sharing control strategy based on multiagent consensus theory is proposed in this article. This method treats each SM as an agent. By exchanging information with its neighbors, each SM can regulate its power in real- time to achieve power sharing. Additionally, an adaptive dynamic compensator is proposed to compensate for control processes in real-time, thereby reducing settling time of the system. Compared to traditional power sharing strategies, the proposed method not only ensures power sharing among SMs but also improves the dynamic performance of the system. Finally, the effectiveness of the proposed method is demonstrated through an experimental prototype.


  • A Generalized Harmonic Extraction Algorithm Based on Multi-Window Average Filter Under Synchronous Rotating Frame

    by Shuo Zhang, Cheng Chen, Bowen Ling, Xiang Li, Daorong Lu, Haibing Hu

    Various harmonic extraction algorithms have been proposed to improve the steady-state and dynamic performance for active power filter. However, it is difficult to select a suitable method for a certain load current scenario. This article analyses the general characteristics of the harmonic extraction based on the ‘frequency shift’ characteristic by Park transform, and it can be transformed into a low-pass filter under the synchronous rotating frame (SRF) for design. Starting from the typical average filter, a general FIR filter structure called multi-window average (MWA) is proposed. According to the actual load current components, aiming at the shortest delay, the design process and guideline are given. Combined with SRF, the MWA structure can generalize recursive discrete Fourier transform (RDFT), cascade delayed signal cancellation (CDSC) and their derived algorithms, which proves the equivalence between time-based harmonic extraction methods and frequency-based ones. Moreover, using the MWA structure can effectively reduce the complexity of the CDSC algorithm. The experiment proves that the typical RDFT and CDSC harmonic extraction can be equivalently realized by using the SRF-based structure. Under the presence of 6 r +1 and 12 r -2 harmonics, the proposed harmonic extraction time can reach 1/4 fundamental cycle. While greatly reducing the dynamic response time, the MWA structure reveals inherent unity among various harmonic extraction algorithms for the first time.


  • A Three-Phase Single-Stage ac/dc Converter Based on Swiss Rectifier and Three-Level LLC Topology

    by Xiang Li, Julu Sun, Liuniu Guo, Mingzhi Gao, Haibing Hu, Ming Xu

    LLC resonant converter is widely used due to its soft switching, high power density, and high efficiency. To incorporate the merits of the LLC resonant tank into a three-phase single-stage ac/dc converter, this article proposes a three-phase single-stage ac/dc converter based on Swiss rectifier and three-level LLC topology. It takes advantage of the high-efficiency Swiss rectifier to convert three-phase ac voltages into three variable dc voltages and interface a three-level LLC resonant circuit. With help of the LLC resonant tank, all the high-frequency three-level switches achieve soft switching. To both regulate the output voltage and achieve three-phase power factor correction, the frequency modulation in combination with the duty cycle control strategy is employed by splitting the resonant current into three parts and then forming three phase sinusoidal currents. The proposed converter's detailed operation principles, steady-state characteristics, and design considerations are given. Finally, a 10 kW experimental prototype with three-phase 220 Vac inputs and 500 Vdc output is built to verify the effectiveness and feasibility of the proposed topology and its control strategy.


  • A Coordination Control With Extra Active Power Exchange Way to Extend Negative Sequence Current Compensation Range for STATCOM Based on Hybrid Cascaded Converter

    by Daorong Lu, Miaoyu Wei, Shibin Shen, Haibing Hu, Yan Xing, Xiang Li

    The star-connected Cascaded H-Bridge (CHB) converter is one of the most attractive multilevel topologies for medium/high-voltage STATCOM. However, due to the fact that CHB has separated dc-links, three-phase unbalanced active powers cannot exchange automatically, which, thus, requires extra zero sequence voltage (ZSV) to eliminate them. Especially when negative sequence current is compensated, the negative sequence current compensation range (NCCR) is seriously limited. To extend the NCCR, this article combines the CHB and the converter with a common dc-link, which is utilized to exchange and eliminate the unbalanced active power generated from CHB. Based on this new active power exchange way and conventional ZSV injection, a novel cluster voltage balancing control method is proposed to eliminate the unbalanced cluster active powers. Moreover, based on the proposed control, the NCCR is identified, which is larger than that based on the conventional control. Finally, the proposed control and the derived NCCR are verified by simulation and experimental results on a 400 V/7.5 kvar Hybrid Cascaded Converter STATCOM.


  • Time Domain Analysis of Three-Phase Single-Stage AC/DC Resonant Converter Using Numerical Calculation

    by Xiang Li, Liuniu Guo, Sainan Chen, Tianchen Lang, Daorong Lu, Haibing Hu

    Since LLC converter is capable of naturally creating the soft-switching condition to improve the overall efficiency, it is widely used in dc–dc applications. Using LLC resonant tank to realize soft switching for three-phase ac–dc converters would be a very promising solution to high efficiency and low cost ac–dc conversion, an LLC -based three-phase single-stage ac–dc converter was configured by taking advantage of three-phase voltage feature $ u_{\mathrm a}$ + $ u_{\mathrm b}$ + $ u_{\mathrm c}$ = 0 and incorporating three bidirectional switches. Because of time-varying feature of three-phase voltages, the input voltage of the converter to the LLC resonant tank is no longer a symmetrical square wave, but a time-varying and asymmetrical three-level waveform, which makes the analysis of the resonant circuit behavior much complicated. Some traditional analysis methods, such as fundamental harmonic approximation and its variants, are impossible to deal with. To overcome this analysis obstacle, this article proposes a numerical analysis method to analyze the time-varying three-level LLC resonant tank for this converter. According to the monotonous change of LLC input voltage in one fundamental cycle, it calculates and determines the time durations of three phases and the corresponding operation modes in each switching cycle. And this numerical analysis method is used to calculate the numerical relationship between the two control variables (switching frequency $ f_{\mathrm s}$ and duty cycle $ D_{\mathrm M}$ ) of this converter and the voltage gain and power level, which is a guideline for the design of the resonant tank parameters and control strategy of the LLC -based three-phase single-stage ac–dc converter. Finally, the time-varying waveforms of $ f_{\mathrm s}$ and $ D_{\mathrm M}$ obtained by numerical calculation well match the PSIM simulation results, and a 3.3-kW three-phase 220Vac input and 48Vdc output prototype was built to verify the effectiveness of the proposed numerical analysis method and the feasibility of the control strategy.


  • Startup Control to Eliminate Inrush Current for Star-Connected Cascaded H-Bridge STATCOM

    by Daorong Lu, Yu Yu, Miaoyu Wei, Xiang Li, Haibing Hu, Yan Xing

    Soft startup is essential to the operation of the star-connected cascaded H-bridge (CHB) STATCOM. The conventional startup stage involves only uncontrolled rectifier process in which the dc voltages are charged by inserting startup resistors to limit the inrush current. Nevertheless, another inrush current is induced at the beginning of normal operation due to the low charged dc voltages during the startup stage. In this article, to eliminate this inrush current, a novel startup control is proposed for further charging the dc voltages after the uncontrolled rectifier process. During this controlled charging process, the startup resistors are not bypassed so as to smoothen the dc voltages and limit the inrush current. In this scenario, the overall dc voltage control with constant charging current is proposed by establishing a relationship between the overall dc voltage and the positive sequence modulation index. Besides, the cluster dc voltage balancing control based on the negative sequence voltage injection is proposed by redistributing the active power of the STATCOM. Moreover, the charging current is designed to reduce the active power of the startup resistors and increase the charging speed. Due to the flexibility of the startup control, it can be applied to any voltage-source-based ac/dc grid-connected converter. Finally, the performance of the proposed control is verified by the simulation and experimental results.


  • Flexible Nonsinusoidal Zero Sequence Voltage Injection Method to Extend Negative Sequence Current Compensation Range for Star-Connected CHB STATCOM

    by Daorong Lu, Chenxing Sha, Yu Yu, Xiang Li, Haibing Hu, Yan Xing

    DC voltage balance based on zero sequence voltage is commonly used for star-connected cascaded H-Bridge (SCHB) STATCOM to compensate negative sequence current. However, zero sequence voltage injection brings about side-effect of increasing STATCOM output voltage and thus the Negative sequence Current Compensation Range (NCCR) is significantly limited to avoid overmodulation. To extend the NCCR, improving the dc voltage utilization by injecting third harmonic component is a typical method. Compared with third harmonic injection (THI), square wave features lower peak-to-average ratio. Unfortunately, the capability of square wave injection (SWI) for the NCCR extension has not been well explored. In this article, to further extend NCCR, not only the SWI is employed for SCHB STATCOM, but also it is compared with THI in term of NCCR by establishing the relationship between the maximum STATCOM voltage and negative sequence current. The comparison results reveal that the THI and SWI both have their own strengths and weaknesses in NCCR, which highly depends on the amplitudes and phases of positive and negative sequence currents. Furthermore, the criteria associated with the amplitudes and phases of the positive and negative sequence currents are derived to determine the harmonic injection method with larger NCCR by using symbolic-graphic combination method and MATLAB tools. As a result, a new harmonic injection method is proposed by selecting the THI or SWI with larger NCCR flexibly according to the amplitudes and phases of positive and negative sequence currents. Finally, the proposed method is verified by experimental results on a 400 V/7.5 kVar SCHB STATCOM prototype.


  • Steady-State Characterization of LLC-Based Single-Stage AC/DC Converter Based on Numerical Analysis

    by Xiang Li, Liuniu Guo, Tianchen Lang, Daorong Lu, Khalil Alluhaybi, Haibing Hu

    The LLC-based single-stage ac/dc converter can achieve zero voltage switching under full load range, which offers a very attractive solution to realize high efficiency, low cost, and extreme compactness of ac/dc power conversion. However, with the introduction of LLC resonant tank in this ac/dc conversion, it becomes very challenging to accurately analyze the steady-state characterization of the converter due to its complex resonant circuit behaviors and time-varying ac input voltage. Although some analysis methods, like first-order harmonics approximation (FHA), extended FHA, and multiharmonic approximation, etc., can be adopted to analyze this converter, they cannot obtain the accurate gain curves, especially when the switching frequency deviates far from the resonant frequency. In this situation, the numerical analysis method is offered to cope with the difficulties resulting from time-varying ac input and dc output fluctuation. A set of equations describing resonant circuit behaviors, power conservation, inductor current, and capacitor voltage are presented. Also, the numerical analysis procedure is given in detail. The numerical calculation results are found that they match with those results in PSIM simulation pretty well. A 1-kW 48-V output prototype is built to verify the effectiveness of the numerical analysis.


  • A Hybrid Boundary Conduction Modulation for a Single-Phase H-bridge Inverter to Alleviate Zero-Crossing Distortion and Enable Reactive Power Capability

    by Hao Yin, Tianchen Lang, Xiang Li, Shixiang Du, Haibing Hu

    Boundary Conduction Modulation(BCM) featuring zero voltage switching has caught researchers' eyes . In single-phase full-bridge inverter with one leg operating in high switching frequency and one leg in line frequency, it is easy to achieve high efficiency. However, severe distortion will be introduced during zero voltage crossing area due to too low switching frequency around this area, and reactive power generation is not allowed under this modulation scheme due to zero voltage crossing issue. This paper proposes a hybrid BCM strategy for a single-phase full-bridge inverter to both alleviate voltage zero-crossing distortion and enable reactive power generation by reshaping the triangular waveform of inductor current into quadrangle waveform by rearranging the driving signals during voltage zero crossing area. This alleviates zero-crossing distortion by avoiding too low switching frequency and enables reactive power generation by employing the hybrid BCM around voltage zero-crossing area. High efficiency can be maintained by combining the proposed hybrid BCM employed only for a small portion of zero crossing area and the conventional BCM for the rest. The principle of operation, theoretical analysis and simulation results are presented in this paper. A 300W microinverter prototype was built to verify the feasibility of the proposed hybrid BCM scheme.