Richard Eiland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Richard Eiland has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dereje Agonafer
Department of Mechanical and Aerospace Engineering, The University of Texas at Arlington , Arlington, TX 76019
3 shared publications - John Edward Fernandes
Mechanical and Aerospace Engineering Department, University of Texas at Arlington, P.O. Box 19023, Arlington, TX 76013
3 shared publications - Bharath Nagendran
Amazon Lab, 126 Thermal Engineer Enterprise, Sunnyvale, CA 94089
2 shared publications - Veerendra Mulay
The University of Texas at Arlington, Arlington, TX
2 shared publications - Ashwin Siddarth
University of Texas at Arlington, Arlington, TX
1 shared publication - Marianna Vallejo
CH2M, 2020 SW 4th Avenue, Street 300, Portland, OR 97201
1 shared publication
Latest Publications
- 27 October 2017
- Published by ASME International in Journal of Electronic Packaging
- Vol. 139 (4)
Effectiveness of Rack-Level Fans—Part II: Control Strategies and System Redundancy
Fan efficiency is known to increase with size. In part I of this study, savings in server fan power on the order of 50% were reported by replacing server-enclosed 60 mm fans with a rear-mounted wall of larger fans (80 mm or 120 mm in size). A methodology for row-wise control of such rack-level fans, with the purpose of simulating an actual product, is previewed and savings comparable to part I are reported. Performance under real-life scenarios such as nonuniform computational loads and fan failure is investigated. Each rack-level setup has distinct advantages. Selecting between configurations would necessitate a compromise between efficiency, redundancy, and cost.
- 27 October 2017
- Published by ASME International in Journal of Electronic Packaging
- Vol. 139 (4)
Effectiveness of Rack-Level Fans—Part II: Control Strategies and System Redundancy
Fan efficiency is known to increase with size. In part I of this study, savings in server fan power on the order of 50% were reported by replacing server-enclosed 60 mm fans with a rear-mounted wall of larger fans (80 mm or 120 mm in size). A methodology for row-wise control of such rack-level fans, with the purpose of simulating an actual product, is previewed and savings comparable to part I are reported. Performance under real-life scenarios such as nonuniform computational loads and fan failure is investigated. Each rack-level setup has distinct advantages. Selecting between configurations would necessitate a compromise between efficiency, redundancy, and cost.
- 27 October 2017
- Published by ASME International in Journal of Electronic Packaging
- Vol. 139 (4)
Effectiveness of Rack-Level Fans—Part I: Energy Savings Through Consolidation
In general, smaller fans operate at lower efficiencies than larger fans of proportional linear dimensions. In this work, the applicability of replacing smaller, 60 mm baseline fans from within the chassis of web servers with an array of larger, geometrically proportional 80 mm and 120 mm fans consolidated to the back of a rack is experimentally tested. Initial characterization of the selected fans showed that the larger fans operate at double peak total efficiency of the smaller fans. A stack of four servers were used in a laboratory setting to represent a rack of servers. When all four servers were stressed at uniform computational loadings, the 80 mm fans resulted in 50.1–52.6% reduction in total rack fan power compared to the baseline fans. The 120 mm fans showed similar reduction in rack fan power of 47.6–54.0% over the baseline. Since actual data centers rarely operate at uniform computational loading across servers in a rack, a worst case scenario test was conceived in which the array of larger fans were controlled by a single server operating at peak computational workload while the other three in the rack remained idle. Despite significant overcooling in the three idle servers, the 80 mm and 120 mm fan configurations still showed 35% and 34% reduction in total rack fan power compared to the baseline fans. The findings strongly suggest that a rack-level fan scheme in which servers share airflow from an array of consolidated larger fans is superior to traditional chassis fans.
- 27 October 2017
- Published by ASME International in Journal of Electronic Packaging
- Vol. 139 (4)
Effectiveness of Rack-Level Fans—Part I: Energy Savings Through Consolidation
In general, smaller fans operate at lower efficiencies than larger fans of proportional linear dimensions. In this work, the applicability of replacing smaller, 60 mm baseline fans from within the chassis of web servers with an array of larger, geometrically proportional 80 mm and 120 mm fans consolidated to the back of a rack is experimentally tested. Initial characterization of the selected fans showed that the larger fans operate at double peak total efficiency of the smaller fans. A stack of four servers were used in a laboratory setting to represent a rack of servers. When all four servers were stressed at uniform computational loadings, the 80 mm fans resulted in 50.1–52.6% reduction in total rack fan power compared to the baseline fans. The 120 mm fans showed similar reduction in rack fan power of 47.6–54.0% over the baseline. Since actual data centers rarely operate at uniform computational loading across servers in a rack, a worst case scenario test was conceived in which the array of larger fans were controlled by a single server operating at peak computational workload while the other three in the rack remained idle. Despite significant overcooling in the three idle servers, the 80 mm and 120 mm fan configurations still showed 35% and 34% reduction in total rack fan power compared to the baseline fans. The findings strongly suggest that a rack-level fan scheme in which servers share airflow from an array of consolidated larger fans is superior to traditional chassis fans.
- Open Access
- 7 September 2017
- Published by ASME International in Journal of Electronic Packaging
- Vol. 139 (4)
Thermal Performance and Efficiency of a Mineral Oil Immersed Server Over Varied Environmental Operating Conditions
Complete immersion of servers in dielectric mineral oil has recently become a promising technique for minimizing cooling energy consumption in data centers. However, a lack of sufficient published data and long-term documentation of oil immersion cooling performance make most data center operators hesitant to apply these approaches to their mission critical facilities. In this study, a single server was fully submerged horizontally in mineral oil. Experiments were conducted to observe the effects of varying the volumetric flow rate and oil inlet temperature on thermal performance and power consumption of the server. Specifically, temperature measurements of the central processing units (CPUs), motherboard (MB) components, and bulk fluid were recorded at steady-state conditions. These results provide an initial bounding envelope of environmental conditions suitable for an oil immersion data center. Comparing with results from baseline tests performed with traditional air cooling, the technology shows a 34.4% reduction in the thermal resistance of the system. Overall, the cooling loop was able to achieve partial power usage effectiveness (pPUECooling) values as low as 1.03. This server level study provides a preview of possible facility energy savings by utilizing high temperature, low flow rate oil for cooling. A discussion on additional opportunities for optimization of information technology (IT) hardware and implementation of oil cooling is also included.
- 7 September 2017
- Published by ASME International in Journal of Electronic Packaging
- Vol. 139 (4)
Open AccessThermal Performance and Efficiency of a Mineral Oil Immersed Server Over Varied Environmental Operating Conditions
Complete immersion of servers in dielectric mineral oil has recently become a promising technique for minimizing cooling energy consumption in data centers. However, a lack of sufficient published data and long-term documentation of oil immersion cooling performance make most data center operators hesitant to apply these approaches to their mission critical facilities. In this study, a single server was fully submerged horizontally in mineral oil. Experiments were conducted to observe the effects of varying the volumetric flow rate and oil inlet temperature on thermal performance and power consumption of the server. Specifically, temperature measurements of the central processing units (CPUs), motherboard (MB) components, and bulk fluid were recorded at steady-state conditions. These results provide an initial bounding envelope of environmental conditions suitable for an oil immersion data center. Comparing with results from baseline tests performed with traditional air cooling, the technology shows a 34.4% reduction in the thermal resistance of the system. Overall, the cooling loop was able to achieve partial power usage effectiveness (pPUECooling) values as low as 1.03. This server level study provides a preview of possible facility energy savings by utilizing high temperature, low flow rate oil for cooling. A discussion on additional opportunities for optimization of information technology (IT) hardware and implementation of oil cooling is also included.