Muneaki Hashimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Muneaki Hashimoto has a total of 208 co-authors. Here are the top co-authors by number of shared publications:
- Kazuaki Kajimoto
Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14, Hayashi-cho, Takamatsu, Kagawa 761-0301, Japan
10 shared publications Takeshi Nara
Department of Molecular and Cellular Parasitology Juntendo University School of Medicine Tokyo Japan
10 shared publicationsTakashi Aoki
9 shared publications- Toshihiro Mita
Department of Tropical Medicine and Parasitology, Faculty of Medicine, Juntendo University, Tokyo, Japan
8 shared publications - Masatoshi Kataoka
Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14, Hayashi-cho, Takamatsu, Kagawa 761-0301, Japan
7 shared publications - Kazumichi Yokota
National Institute of Advanced Industrial Science and Technology
6 shared publications
Latest Publications
- Open Access
Measuring Asymmetric Ionic Current Waveform Through Micropores for Detecting Reduced Red Blood Cell Deformability Due to Plasmodium falciparum Infection
The mechanisms underlying reduced deformability of red blood cells (RBCs) in Plasmodium falciparum remain unclear. The decrease in RBC deformability associated with malarial infection was measured using ektacytometry, and only mean values were evaluated. In this study, we report the development of a microfluidic sensing device that can evaluate decreased RBC deformability at the single-cell level by measuring ionic current waveforms through micropores. Using an in vitro culture system, we found that when RBC deformability was reduced by P. falciparum infection, ionic current waveforms changed. As RBC deformability decreased, waveforms became asymmetric. Computer simulations suggested that these waveform parameters are largely independent of RBC size and may represent a reliable indicator of diminished deformability. This novel microfluidic RBC deformability sensor allows for detailed single-cell analysis of malaria-associated deformability reduction, potentially aiding in elucidating its pathology.
Open AccessMeasuring Asymmetric Ionic Current Waveform Through Micropores for Detecting Reduced Red Blood Cell Deformability Due to Plasmodium falciparum Infection
The mechanisms underlying reduced deformability of red blood cells (RBCs) in Plasmodium falciparum remain unclear. The decrease in RBC deformability associated with malarial infection was measured using ektacytometry, and only mean values were evaluated. In this study, we report the development of a microfluidic sensing device that can evaluate decreased RBC deformability at the single-cell level by measuring ionic current waveforms through micropores. Using an in vitro culture system, we found that when RBC deformability was reduced by P. falciparum infection, ionic current waveforms changed. As RBC deformability decreased, waveforms became asymmetric. Computer simulations suggested that these waveform parameters are largely independent of RBC size and may represent a reliable indicator of diminished deformability. This novel microfluidic RBC deformability sensor allows for detailed single-cell analysis of malaria-associated deformability reduction, potentially aiding in elucidating its pathology.
- Open Access
- 12 August 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (8) , 272
Application of Micropore Device for Accurate, Easy, and Rapid Discrimination of Saccharomyces pastorianus from Dekkera spp.
Traceability analysis, such as identification and discrimination of yeasts used for fermentation, is important for ensuring manufacturing efficiency and product safety during brewing. However, conventional methods based on morphological and physiological properties have disadvantages such as time consumption and low sensitivity. In this study, the resistive pulse method (RPM) was employed to discriminate between Saccharomyces pastorianus and Dekkera anomala and S. pastorianus and D. bruxellensis by measuring the ionic current response of cells flowing through a microsized pore. The height and shape of the pulse signal were used for the simultaneous measurement of the size, shape, and surface charge of individual cells. Accurate discrimination of S. pastorianus from Dekkera spp. was observed with a recall rate of 96.3 ± 0.8%. Furthermore, budding S. pastorianus was quantitatively detected by evaluating the shape of the waveform of the current ionic blockade. We showed a proof-of-concept demonstration of RPM for the detection of contamination of Dekkera spp. in S. pastorianus and for monitoring the fermentation of S. pastorianus through the quantitative detection of budding cells.
- 12 August 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (8) , 272
Open AccessApplication of Micropore Device for Accurate, Easy, and Rapid Discrimination of Saccharomyces pastorianus from Dekkera spp.
Traceability analysis, such as identification and discrimination of yeasts used for fermentation, is important for ensuring manufacturing efficiency and product safety during brewing. However, conventional methods based on morphological and physiological properties have disadvantages such as time consumption and low sensitivity. In this study, the resistive pulse method (RPM) was employed to discriminate between Saccharomyces pastorianus and Dekkera anomala and S. pastorianus and D. bruxellensis by measuring the ionic current response of cells flowing through a microsized pore. The height and shape of the pulse signal were used for the simultaneous measurement of the size, shape, and surface charge of individual cells. Accurate discrimination of S. pastorianus from Dekkera spp. was observed with a recall rate of 96.3 ± 0.8%. Furthermore, budding S. pastorianus was quantitatively detected by evaluating the shape of the waveform of the current ionic blockade. We showed a proof-of-concept demonstration of RPM for the detection of contamination of Dekkera spp. in S. pastorianus and for monitoring the fermentation of S. pastorianus through the quantitative detection of budding cells.
- Open Access
- 12 March 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (3) , 78
Effect of Electrolyte Concentration on Cell Sensing by Measuring Ionic Current Waveform through Micropores
Immunostaining has been widely used in cancer prognosis for the quantitative detection of cancer cells present in the bloodstream. However, conventional detection methods based on the target membrane protein expression exhibit the risk of missing cancer cells owing to variable protein expressions. In this study, the resistive pulse method (RPM) was employed to discriminate between cultured cancer cells (NCI-H1650) and T lymphoblastoid leukemia cells (CCRF-CEM) by measuring the ionic current response of cells flowing through a micro-space. The height and shape of a pulse signal were used for the simultaneous measurement of size, deformability, and surface charge of individual cells. An accurate discrimination of cancer cells could not be obtained using 1.0 × phosphate-buffered saline (PBS) as an electrolyte solution to compare the size measurements by a microscopic observation. However, an accurate discrimination of cancer cells with a discrimination error rate of 4.5 ± 0.5% was achieved using 0.5 × PBS containing 2.77% glucose as the electrolyte solution. The potential application of RPM for the accurate discrimination of cancer cells from leukocytes was demonstrated through the measurement of the individual cell size, deformability, and surface charge in a solution with a low electrolyte concentration.
- 12 March 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (3) , 78
Open AccessEffect of Electrolyte Concentration on Cell Sensing by Measuring Ionic Current Waveform through Micropores
Immunostaining has been widely used in cancer prognosis for the quantitative detection of cancer cells present in the bloodstream. However, conventional detection methods based on the target membrane protein expression exhibit the risk of missing cancer cells owing to variable protein expressions. In this study, the resistive pulse method (RPM) was employed to discriminate between cultured cancer cells (NCI-H1650) and T lymphoblastoid leukemia cells (CCRF-CEM) by measuring the ionic current response of cells flowing through a micro-space. The height and shape of a pulse signal were used for the simultaneous measurement of size, deformability, and surface charge of individual cells. An accurate discrimination of cancer cells could not be obtained using 1.0 × phosphate-buffered saline (PBS) as an electrolyte solution to compare the size measurements by a microscopic observation. However, an accurate discrimination of cancer cells with a discrimination error rate of 4.5 ± 0.5% was achieved using 0.5 × PBS containing 2.77% glucose as the electrolyte solution. The potential application of RPM for the accurate discrimination of cancer cells from leukocytes was demonstrated through the measurement of the individual cell size, deformability, and surface charge in a solution with a low electrolyte concentration.
- Open Access
- 11 November 2020
- Published by MDPI AG in Microorganisms
- Vol. 8 (11) , 1769
Highly Sensitive and Rapid Quantitative Detection of Plasmodium falciparum Using an Image Cytometer
The gold standard for malaria diagnosis is microscopic examination of blood films by expert microscopists. It is important to detect submicroscopic and asymptomatic Plasmodium infections in people, therefore the development of highly sensitive devices for diagnosing malaria is required. In the present study, we investigated whether an imaging cytometer was useful for the highly sensitive quantitative detection of parasites. Whole blood samples were prepared from uninfected individuals spiked with Plasmodium falciparum-infected erythrocytes. Thereafter, erythrocytes were purified using a push column comprising of a syringe filter unit with SiO2-nanofiber filters. After adding the erythrocytes, stained with nuclear stain, to a six-well plate, quantitative detection of the parasites was performed using an image cytometer, CQ1. Imaging of 2.6 × 106 erythrocytes was completed in 3 min, and the limit of detection indicated parasitemia of 0.00010% (≈5 parasites/μL of blood). In addition to rapid, highly sensitive, and quantitative detection, the ease of application and economic costs, image cytometry could be efficiently applied to diagnose submicroscopic parasites in infected people from endemic countries.
- 11 November 2020
- Published by MDPI AG in Microorganisms
- Vol. 8 (11) , 1769
Open AccessHighly Sensitive and Rapid Quantitative Detection of Plasmodium falciparum Using an Image Cytometer
The gold standard for malaria diagnosis is microscopic examination of blood films by expert microscopists. It is important to detect submicroscopic and asymptomatic Plasmodium infections in people, therefore the development of highly sensitive devices for diagnosing malaria is required. In the present study, we investigated whether an imaging cytometer was useful for the highly sensitive quantitative detection of parasites. Whole blood samples were prepared from uninfected individuals spiked with Plasmodium falciparum-infected erythrocytes. Thereafter, erythrocytes were purified using a push column comprising of a syringe filter unit with SiO2-nanofiber filters. After adding the erythrocytes, stained with nuclear stain, to a six-well plate, quantitative detection of the parasites was performed using an image cytometer, CQ1. Imaging of 2.6 × 106 erythrocytes was completed in 3 min, and the limit of detection indicated parasitemia of 0.00010% (≈5 parasites/μL of blood). In addition to rapid, highly sensitive, and quantitative detection, the ease of application and economic costs, image cytometry could be efficiently applied to diagnose submicroscopic parasites in infected people from endemic countries.
- Open Access
- 4 September 2020
- Published by MDPI AG in Microorganisms
- Vol. 8 (9) , 1356
Quantitative Detection of Plasmodium falciparum Using, LUNA-FL, A Fluorescent Cell Counter
The microscopic examination of Giemsa-stained thin and/or thick blood films (Giemsa microscopy) is the standard method of malaria diagnosis. However, the results of the diagnosis significantly depend on the skills of clinical technicians. Furthermore, sample preparation and analysis are laborious and time-consuming. Therefore, in this study, we investigated if a commercially available fluorescent cell counter, LUNA-FL, was useful for the detection of Plasmodium parasite and the estimation of parasitemia. Whole blood samples from uninfected persons, spiked with P. falciparum-infected erythrocytes, were analysed. Most of the leucocytes and platelets were removed from whole blood samples with SiO2-nanofiber filters set on spin columns. The filtered samples were stained with acridine orange, and automatic detection, as well as counting of erythrocytes and parasites, were performed using LUNA-FL. Whole blood, with various levels of parasites, was analysed by Giemsa microscopy or with LUNA-FL to estimate parasitemia, and a comparative analysis was performed. The coefficient determination value of the regression line was high (R2 = 0.98), indicating that accurate quantitative parasite detection could be performed using LUNA-FL. LUNA-FL has a low running cost; it is compact, fast, and easy to operate, and may therefore be useful for point-of-care testing in the endemic areas.
- 4 September 2020
- Published by MDPI AG in Microorganisms
- Vol. 8 (9) , 1356
Open AccessQuantitative Detection of Plasmodium falciparum Using, LUNA-FL, A Fluorescent Cell Counter
The microscopic examination of Giemsa-stained thin and/or thick blood films (Giemsa microscopy) is the standard method of malaria diagnosis. However, the results of the diagnosis significantly depend on the skills of clinical technicians. Furthermore, sample preparation and analysis are laborious and time-consuming. Therefore, in this study, we investigated if a commercially available fluorescent cell counter, LUNA-FL, was useful for the detection of Plasmodium parasite and the estimation of parasitemia. Whole blood samples from uninfected persons, spiked with P. falciparum-infected erythrocytes, were analysed. Most of the leucocytes and platelets were removed from whole blood samples with SiO2-nanofiber filters set on spin columns. The filtered samples were stained with acridine orange, and automatic detection, as well as counting of erythrocytes and parasites, were performed using LUNA-FL. Whole blood, with various levels of parasites, was analysed by Giemsa microscopy or with LUNA-FL to estimate parasitemia, and a comparative analysis was performed. The coefficient determination value of the regression line was high (R2 = 0.98), indicating that accurate quantitative parasite detection could be performed using LUNA-FL. LUNA-FL has a low running cost; it is compact, fast, and easy to operate, and may therefore be useful for point-of-care testing in the endemic areas.
- Open Access
- 20 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Development of a quantitative, portable, and automated fluorescent blue-ray device-based malaria diagnostic equipment with an on-disc SiO2 nanofiber filter
There is an urgent need to develop an automated malaria diagnostic system that can easily and rapidly detect malaria parasites and determine the proportion of malaria-infected erythrocytes in the clinical blood samples. In this study, we developed a quantitative, mobile, and fully automated malaria diagnostic system equipped with an on-disc SiO2 nanofiber filter and blue-ray devices. The filter removes the leukocytes and platelets from the blood samples, which interfere with the accurate detection of malaria by the blue-ray devices. We confirmed that the filter, which can be operated automatically by centrifugal force due to the rotation of the disc, achieved a high removal rate of leukocytes (99.7%) and platelets (90.2%) in just 30 s. The automated system exhibited a higher sensitivity (100%) and specificity (92.8%) for detecting Plasmodium falciparum from the blood of 274 asymptomatic individuals in Kenya when compared to the common rapid diagnosis test (sensitivity = 98.1% and specificity = 54.8%). This indicated that this system can be a potential alternative to conventional methods used at local health facilities, which lack basic infrastructure.
- 20 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessDevelopment of a quantitative, portable, and automated fluorescent blue-ray device-based malaria diagnostic equipment with an on-disc SiO2 nanofiber filter
There is an urgent need to develop an automated malaria diagnostic system that can easily and rapidly detect malaria parasites and determine the proportion of malaria-infected erythrocytes in the clinical blood samples. In this study, we developed a quantitative, mobile, and fully automated malaria diagnostic system equipped with an on-disc SiO2 nanofiber filter and blue-ray devices. The filter removes the leukocytes and platelets from the blood samples, which interfere with the accurate detection of malaria by the blue-ray devices. We confirmed that the filter, which can be operated automatically by centrifugal force due to the rotation of the disc, achieved a high removal rate of leukocytes (99.7%) and platelets (90.2%) in just 30 s. The automated system exhibited a higher sensitivity (100%) and specificity (92.8%) for detecting Plasmodium falciparum from the blood of 274 asymptomatic individuals in Kenya when compared to the common rapid diagnosis test (sensitivity = 98.1% and specificity = 54.8%). This indicated that this system can be a potential alternative to conventional methods used at local health facilities, which lack basic infrastructure.
- 1 December 2019
- Published by Elsevier in Parasitology International
- Vol. 73, 101941
Nucleic acid purification from dried blood spot on FTA Elute Card provides template for polymerase chain reaction for highly sensitive Plasmodium detection
- 1 December 2019
- Published by Elsevier in Parasitology International
- Vol. 73, 101941
Nucleic acid purification from dried blood spot on FTA Elute Card provides template for polymerase chain reaction for highly sensitive Plasmodium detection
- Open Access
- 19 June 2018
- Published by Springer Nature in Malaria Journal
- Vol. 17 (1) , 235
In situ loop-mediated isothermal amplification (LAMP) for identification of Plasmodium species in wide-range thin blood smears
Five species of Plasmodium are known to infect humans. For proper treatment of malaria, accurate identification of the parasite species is crucial. The current gold standard for malaria diagnosis is microscopic examination of Giemsa-stained blood smears. Since the parasite species are identified by microscopists who manually search for the parasite-infected red blood cells (RBCs), misdiagnosis due to human error tends to occur in case of low parasitaemia or mixed infection. Then, molecular methods, such as polymerase chain reaction or loop-mediated isothermal amplification (LAMP), are required for conclusive identification of the parasite species. However, since molecular methods are highly sensitive, false-positive results tend to occur due to contamination (carry over) or the target gene products may be detected even after clearance of the parasites from the patient’s blood. Therefore, accurate detection of parasites themselves by microscopic examination is essential for the definitive diagnosis. Thus, the method of in situ LAMP for the parasites was developed. Red blood cell suspensions, including cultured Plasmodium falciparum, strain 3D7, infected-RBCs, were dispersed on cyclic olefin copolymer (COC) plate surfaces rendered hydrophilic by reactive ion-etching treatment using a SAMCO RIE system (hydrophilic-treated), followed by standing for 10 min to allow the RBCs to settle down on the plate surface. By rinsing the plate with RPMI 1640 medium, monolayers of RBCs formed on almost the entire plate surface. The plate was then dried with a hair drier. The RBCs were fixed with formalin, followed by permeabilization with Triton X-100. Then, amplification of the P. falciparum 18S rRNA gene by the LAMP reaction with digoxigenin (DIG)-labelled dUTP and a specific primer set was performed. Infected RBCs as fluorescence-positive cells with anti-DIG antibodies conjugated with fluorescein using fluorescent microscopy could be detected. The present work shows that the potential of in situ LAMP for the identification of Plasmodium species at the single cell level on hydrophilic-treated COC palates, allowing highly sensitive and accurate malaria diagnosis. The findings will improve the efficacy of the gold standard method for malaria diagnosis.
- 19 June 2018
- Published by Springer Nature in Malaria Journal
- Vol. 17 (1) , 235
Open AccessIn situ loop-mediated isothermal amplification (LAMP) for identification of Plasmodium species in wide-range thin blood smears
Five species of Plasmodium are known to infect humans. For proper treatment of malaria, accurate identification of the parasite species is crucial. The current gold standard for malaria diagnosis is microscopic examination of Giemsa-stained blood smears. Since the parasite species are identified by microscopists who manually search for the parasite-infected red blood cells (RBCs), misdiagnosis due to human error tends to occur in case of low parasitaemia or mixed infection. Then, molecular methods, such as polymerase chain reaction or loop-mediated isothermal amplification (LAMP), are required for conclusive identification of the parasite species. However, since molecular methods are highly sensitive, false-positive results tend to occur due to contamination (carry over) or the target gene products may be detected even after clearance of the parasites from the patient’s blood. Therefore, accurate detection of parasites themselves by microscopic examination is essential for the definitive diagnosis. Thus, the method of in situ LAMP for the parasites was developed. Red blood cell suspensions, including cultured Plasmodium falciparum, strain 3D7, infected-RBCs, were dispersed on cyclic olefin copolymer (COC) plate surfaces rendered hydrophilic by reactive ion-etching treatment using a SAMCO RIE system (hydrophilic-treated), followed by standing for 10 min to allow the RBCs to settle down on the plate surface. By rinsing the plate with RPMI 1640 medium, monolayers of RBCs formed on almost the entire plate surface. The plate was then dried with a hair drier. The RBCs were fixed with formalin, followed by permeabilization with Triton X-100. Then, amplification of the P. falciparum 18S rRNA gene by the LAMP reaction with digoxigenin (DIG)-labelled dUTP and a specific primer set was performed. Infected RBCs as fluorescence-positive cells with anti-DIG antibodies conjugated with fluorescein using fluorescent microscopy could be detected. The present work shows that the potential of in situ LAMP for the identification of Plasmodium species at the single cell level on hydrophilic-treated COC palates, allowing highly sensitive and accurate malaria diagnosis. The findings will improve the efficacy of the gold standard method for malaria diagnosis.
- 1 June 2018
- Published by American Society of Parasitologists in Journal of Parasitology
- Vol. 104 (3) , 283-288
Pseudo-Infected Red Blood Cell Beads as Positive Control for Cell Microarray Chip–Based Detection of Plasmodium-Infected RBCs
The cell microarray chip is a polystyrene plate with 20,944 microchambers and is used to detect red blood cells (RBCs) infected with the causative agent of malaria, Plasmodium. Plasmodium-infected red blood cells (iRBCs) stained with a nuclear staining dye (SYTO 21) form a monolayer on the bottom of the microchambers, and about 130 RBCs were accommodated in each such microchamber of the chip. The iRBCs in the RBC monolayer (containing 2.7 million RBCs) can be identified using a fluorescence detector, and the infection rate can be calculated by counting the number of fluorescent positive RBCs. This diagnostic device is highly sensitive and hence advantageous for early diagnosis of malaria infections in endemic areas. However, a standard positive control for Plasmodium-infected RBCs is required to ensure that the reagents and detectors of these cell microarray chips are working efficiently in remote endemic areas. Here, we introduce "pseudo iRBC beads" which consist of a mixture of DEA beads mimicking RBCs and DEA beads coated with nucleic acids mimicking nuclei of the parasite. These beads can be stained with SYTO 21, applied onto the cell microarray chip to form a monolayer, and detected using the fluorescence detector in the same way as iRBCs. Therefore, introduction of pseudo iRBC beads as a positive control ensures unbiased malaria diagnoses with the cell microarray chip device in remote endemic areas.
- 1 June 2018
- Published by American Society of Parasitologists in Journal of Parasitology
- Vol. 104 (3) , 283-288
Pseudo-Infected Red Blood Cell Beads as Positive Control for Cell Microarray Chip–Based Detection of Plasmodium-Infected RBCs
The cell microarray chip is a polystyrene plate with 20,944 microchambers and is used to detect red blood cells (RBCs) infected with the causative agent of malaria, Plasmodium. Plasmodium-infected red blood cells (iRBCs) stained with a nuclear staining dye (SYTO 21) form a monolayer on the bottom of the microchambers, and about 130 RBCs were accommodated in each such microchamber of the chip. The iRBCs in the RBC monolayer (containing 2.7 million RBCs) can be identified using a fluorescence detector, and the infection rate can be calculated by counting the number of fluorescent positive RBCs. This diagnostic device is highly sensitive and hence advantageous for early diagnosis of malaria infections in endemic areas. However, a standard positive control for Plasmodium-infected RBCs is required to ensure that the reagents and detectors of these cell microarray chips are working efficiently in remote endemic areas. Here, we introduce "pseudo iRBC beads" which consist of a mixture of DEA beads mimicking RBCs and DEA beads coated with nucleic acids mimicking nuclei of the parasite. These beads can be stained with SYTO 21, applied onto the cell microarray chip to form a monolayer, and detected using the fluorescence detector in the same way as iRBCs. Therefore, introduction of pseudo iRBC beads as a positive control ensures unbiased malaria diagnoses with the cell microarray chip device in remote endemic areas.
- Open Access
- 1 April 2018
- Published by Centers for Disease Control and Prevention (CDC) in Emerging Infectious Diseases
- Vol. 24 (4) , 718-726
Artemisinin-ResistantPlasmodium falciparumwith High Survival Rates, Uganda, 2014–2016
Because ≈90% of malaria cases occur in Africa, emergence of artemisinin-resistant Plasmodium falciparum in Africa poses a serious public health threat. To assess emergence of artemisinin-resistant parasites in Uganda during 2014–2016, we used the recently developed ex vivo ring-stage survival assay, which estimates ring-stage–specific P. falciparum susceptibility to artemisinin. We conducted 4 cross-sectional surveys to assess artemisinin sensitivity in Gulu, Uganda. Among 194 isolates, survival rates (ratio of viable drug-exposed parasites to drug-nonexposed controls) were high (>10%) for 4 isolates. Similar rates have been closely associated with delayed parasite clearance after drug treatment and are considered to be a proxy for the artemisinin-resistant phenotype. Of these, the PfKelch13 mutation was observed in only 1 isolate, A675V. Population genetics analysis suggested that these possibly artemisinin-resistant isolates originated in Africa. Large-scale surveillance of possibly artemisinin-resistant parasites in Africa would provide useful information about treatment outcomes and help regional malaria control.
- 1 April 2018
- Published by Centers for Disease Control and Prevention (CDC) in Emerging Infectious Diseases
- Vol. 24 (4) , 718-726
Open AccessArtemisinin-ResistantPlasmodium falciparumwith High Survival Rates, Uganda, 2014–2016
Because ≈90% of malaria cases occur in Africa, emergence of artemisinin-resistant Plasmodium falciparum in Africa poses a serious public health threat. To assess emergence of artemisinin-resistant parasites in Uganda during 2014–2016, we used the recently developed ex vivo ring-stage survival assay, which estimates ring-stage–specific P. falciparum susceptibility to artemisinin. We conducted 4 cross-sectional surveys to assess artemisinin sensitivity in Gulu, Uganda. Among 194 isolates, survival rates (ratio of viable drug-exposed parasites to drug-nonexposed controls) were high (>10%) for 4 isolates. Similar rates have been closely associated with delayed parasite clearance after drug treatment and are considered to be a proxy for the artemisinin-resistant phenotype. Of these, the PfKelch13 mutation was observed in only 1 isolate, A675V. Population genetics analysis suggested that these possibly artemisinin-resistant isolates originated in Africa. Large-scale surveillance of possibly artemisinin-resistant parasites in Africa would provide useful information about treatment outcomes and help regional malaria control.