Masahiro Ichikawa
Research Subjects
Research Interests
Masahiro Ichikawa has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
D. Aprile
Consorzio RFX (CNR, ENEA, INFN, Univ. of Padova, Acciaierie Venete), c.so Stati Uniti 4, 35127, Padova, ITALY
2 shared publications- Emanuele Sartori
Consorzio RFX (CNR, ENEA, INFN, Universit di Padova, Acciaierie Venete SpA), Padua, Italy
2 shared publications - Giuseppe Chitarin
Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4
2 shared publications J. Hiratsuka
QST, National Institutes for Quantum and Radiological Science and Technology, Naka, Ibaraki-ken, JAPAN
2 shared publications- Nicolo' Marconato
Department of Industrial Engineering, University of Padova, Via Gradenigo 6/A, 35131 Padova, Italy
2 shared publications A. Kojima
National Institute for Quantum and Radiological Science and Technology (QST)
1 shared publication
Latest Publications
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 060009
Benchmark of 3D multi-beamlet numerical models for the optics design of negative ion accelerators
The optics design of the multi-beamlet negative ion accelerator for MITICA has been verified by means of specific experiments in the NITS test facility at the QST lab, employing a scaled-down configuration having the same features as the accelerator of MITICA and ITER HNB. The experiments confirmed the validity of the accelerator design. However it was found that, in the presence of transverse magnetic field in the ion extraction stage, the ion beamlet deflection in numerical simulations was somehow underestimated with respect to the beamlet deflection inferred from thermal images of a CFC target exposed to the negative ion beam. A detailed benchmark, using also another (completely independent) numerical model of the accelerator, has allowed the identification of possible origins of the differences.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 060009
Benchmark of 3D multi-beamlet numerical models for the optics design of negative ion accelerators
The optics design of the multi-beamlet negative ion accelerator for MITICA has been verified by means of specific experiments in the NITS test facility at the QST lab, employing a scaled-down configuration having the same features as the accelerator of MITICA and ITER HNB. The experiments confirmed the validity of the accelerator design. However it was found that, in the presence of transverse magnetic field in the ion extraction stage, the ion beamlet deflection in numerical simulations was somehow underestimated with respect to the beamlet deflection inferred from thermal images of a CFC target exposed to the negative ion beam. A detailed benchmark, using also another (completely independent) numerical model of the accelerator, has allowed the identification of possible origins of the differences.
- Open Access
- 9 August 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1869 (1) , 030024
Determination of the meniscus shape of a negative ion beam from an experimentally obtained beam profile
In order to understand the physics mechanism of a negative ion extraction in negative ion sources, an emission surface of the negative ions around an aperture at a plasma grid, so-called a meniscus, has been analyzed by an inverse calculation of the negative ion trajectory in a two dimensional beam analysis code. In this method, the meniscus is defined as the final position of the negative ion trajectories which are inversely calculated from the measured beam profile to the plasma grid. In a case of the volume-produced negative ions, the calculated meniscus by the inverse calculation was similar to that obtained in conventional beam simulation codes for positive ion extractions such as BEAMORBT and SLACCAD. The negative ion current density was uniform along the meniscus. This indicates that the negative ions produced in the plasma are transported to the plasma grid uniformly as considered in the transportation of the positive ions. However, in a surface production case of negative ions, where the negative ions are generated near the plasma grid with lower work function by seeding cesium, the current density in the peripheral region of the meniscus close to the plasma grid surface was estimated to be 2 times larger than the center region, which suggested that the extraction process of the surface-produced negative ions was much different with that for the positive ions. Because this non-uniform profile of the current density made the meniscus shape strongly concave, the beam extracted from the peripheral region could have a large divergence angle, which might be one of origins of so-called beam halo. This is the first results of the determination of the meniscus based on the experiment, which is useful to improve the prediction of the meniscus shape and heat loads based on the beam trajectories including beam halo.
- 9 August 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1869 (1) , 030024
Open AccessDetermination of the meniscus shape of a negative ion beam from an experimentally obtained beam profile
In order to understand the physics mechanism of a negative ion extraction in negative ion sources, an emission surface of the negative ions around an aperture at a plasma grid, so-called a meniscus, has been analyzed by an inverse calculation of the negative ion trajectory in a two dimensional beam analysis code. In this method, the meniscus is defined as the final position of the negative ion trajectories which are inversely calculated from the measured beam profile to the plasma grid. In a case of the volume-produced negative ions, the calculated meniscus by the inverse calculation was similar to that obtained in conventional beam simulation codes for positive ion extractions such as BEAMORBT and SLACCAD. The negative ion current density was uniform along the meniscus. This indicates that the negative ions produced in the plasma are transported to the plasma grid uniformly as considered in the transportation of the positive ions. However, in a surface production case of negative ions, where the negative ions are generated near the plasma grid with lower work function by seeding cesium, the current density in the peripheral region of the meniscus close to the plasma grid surface was estimated to be 2 times larger than the center region, which suggested that the extraction process of the surface-produced negative ions was much different with that for the positive ions. Because this non-uniform profile of the current density made the meniscus shape strongly concave, the beam extracted from the peripheral region could have a large divergence angle, which might be one of origins of so-called beam halo. This is the first results of the determination of the meniscus based on the experiment, which is useful to improve the prediction of the meniscus shape and heat loads based on the beam trajectories including beam halo.
- Open Access
- 1 January 2016
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 11, 2405108
Investigation of Oxygen-Induced-Arcing in Cs-Seeded Negative Ion Source
High-power and long-pulse arc discharges of 150 kW for 100 s have been achieved for the first time by suppressing oxygen-induced-arcing which was one of the critical issues on JT-60SA negative ion source. Toward the realization of such arc discharge, the suppression of recycling of oxygen from the arc chamber wall was found to be a key issue in the large-size arc-driven negative ion source. Because the experimental results showed that this oxygen was derived from release of water due to high temperature chamber wall of heated by an arc discharge, the baking of the arc chamber was tried to reduce water adsorbing to the chamber before the long-pulse discharge. After the baking at 80 • C for 8 hours, since the oxygen level was reduced to half of that before baking, the available pulse duration became twice longer. By combining this baking and long-pulse conditioning shots, the stable long-pulse arc discharge has been obtained. This result contributes to the improvement of availability of the large-size negative ion sources which require long-conditioning time.
- 1 January 2016
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 11, 2405108
Open AccessInvestigation of Oxygen-Induced-Arcing in Cs-Seeded Negative Ion Source
High-power and long-pulse arc discharges of 150 kW for 100 s have been achieved for the first time by suppressing oxygen-induced-arcing which was one of the critical issues on JT-60SA negative ion source. Toward the realization of such arc discharge, the suppression of recycling of oxygen from the arc chamber wall was found to be a key issue in the large-size arc-driven negative ion source. Because the experimental results showed that this oxygen was derived from release of water due to high temperature chamber wall of heated by an arc discharge, the baking of the arc chamber was tried to reduce water adsorbing to the chamber before the long-pulse discharge. After the baking at 80 • C for 8 hours, since the oxygen level was reduced to half of that before baking, the available pulse duration became twice longer. By combining this baking and long-pulse conditioning shots, the stable long-pulse arc discharge has been obtained. This result contributes to the improvement of availability of the large-size negative ion sources which require long-conditioning time.
- 1 November 1986
- Vol. 55 (6) , 783-8
[Mediastinal hemorrhage as a complication of retrograde brachial angiography].
- 1 November 1986
- Vol. 55 (6) , 783-8
[Mediastinal hemorrhage as a complication of retrograde brachial angiography].