Josette Zaklit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Josette Zaklit has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Gale L. Craviso
Department of Pharmacology, University of Nevada, Reno School of Medicine, Reno, Nevada
5 shared publicationsNormand Leblanc
Department of Pharmacology, University of Nevada, Reno School of Medicine, Reno, Nevada
5 shared publicationsIndira Chatterjee
Department of Electrical and Biomedical Engineering, College of Engineering, University of Nevada, Reno, NV 89557, USA
3 shared publicationsYantao Shen
Department of Electrical and Biomedical Engineering, University of Nevada, Reno, Reno, Nevada 89557, USA
3 shared publications- Gale L. Craviso
Department of Pharmacology University of Nevada Reno School of Medicine Reno Nevada USA
2 shared publications - Lisha Yang
Department of Pharmacology, University of Nevada, Reno School of Medicine, Reno, NV, United States of America
2 shared publications
Latest Publications
- 22 July 2026
- Published by Wiley in Journal of Neurochemistry
- Vol. 170 (7) , e70525
Activation of GCaMP6f‐Expressing Chromaffin and Satellite Glial Cells in Murine Adrenal Slices by Nanosecond Electric Pulses
Nanosecond electric pulses (NEP) are being explored as a novel bioelectric stimulus to modulate neurosecretion. Recently we reported that NEP trigger transient, voltage‐gated Ca 2+ channel‐mediated Ca 2+ influx in cultured murine adrenal chromaffin cells (ACC) expressing the genetically‐encoded Ca 2+ indicator GCaMP6f. The present study investigated ACC Ca 2+ responses to NEP in acute adrenal slices from mice that expressed GCaMP6f in both ACC and satellite glial cells (SGC), as well as exclusively in SGC. Adrenal glands from male and female mice were sectioned into 100 μm slices that were placed in a chamber and perfused at a rate of 3–4 mL/min with a balanced salt solution maintained at 35°C. A custom‐fabricated non‐contact electrode delivered NEP ranging from 12 to 90 ns to a large area of the adrenal medulla. Our results show that a single 30 ns pulse elicited a rapid, transient rise in intracellular Ca 2+ in ACC in situ. Like NEP‐induced Ca 2+ responses in cultured ACC, ACC Ca 2+ responses in situ depended on extracellular Ca 2+ and voltage‐gated Ca 2+ channel activation. The nicotinic receptor antagonist hexamethonium failed to inhibit these responses, indicating that NEP stimulation, in contrast to stimulation with conventional duration electrical pulses, activates ACC directly rather than indirectly through activation of splanchnic nerve terminals. Furthermore, NEP exposure of the adrenal medulla also resulted in Ca 2+ increases in surrounding SGC that were slower in onset and longer in duration than those evoked by NEP in ACC. Finally, comparison of Ca 2+ responses elicited by NEP trains in ACC in situ to those evoked by such trains in ACC in vitro revealed that the native tissue environment promotes more highly synchronized Ca 2+ responses. Together, these results lay the foundation for future studies exploring the potential for NEP to modulate catecholamine release from ACC remotely and non‐invasively in vivo. image
- 22 July 2026
- Published by Wiley in Journal of Neurochemistry
- Vol. 170 (7) , e70525
Activation of GCaMP6f‐Expressing Chromaffin and Satellite Glial Cells in Murine Adrenal Slices by Nanosecond Electric Pulses
Nanosecond electric pulses (NEP) are being explored as a novel bioelectric stimulus to modulate neurosecretion. Recently we reported that NEP trigger transient, voltage‐gated Ca 2+ channel‐mediated Ca 2+ influx in cultured murine adrenal chromaffin cells (ACC) expressing the genetically‐encoded Ca 2+ indicator GCaMP6f. The present study investigated ACC Ca 2+ responses to NEP in acute adrenal slices from mice that expressed GCaMP6f in both ACC and satellite glial cells (SGC), as well as exclusively in SGC. Adrenal glands from male and female mice were sectioned into 100 μm slices that were placed in a chamber and perfused at a rate of 3–4 mL/min with a balanced salt solution maintained at 35°C. A custom‐fabricated non‐contact electrode delivered NEP ranging from 12 to 90 ns to a large area of the adrenal medulla. Our results show that a single 30 ns pulse elicited a rapid, transient rise in intracellular Ca 2+ in ACC in situ. Like NEP‐induced Ca 2+ responses in cultured ACC, ACC Ca 2+ responses in situ depended on extracellular Ca 2+ and voltage‐gated Ca 2+ channel activation. The nicotinic receptor antagonist hexamethonium failed to inhibit these responses, indicating that NEP stimulation, in contrast to stimulation with conventional duration electrical pulses, activates ACC directly rather than indirectly through activation of splanchnic nerve terminals. Furthermore, NEP exposure of the adrenal medulla also resulted in Ca 2+ increases in surrounding SGC that were slower in onset and longer in duration than those evoked by NEP in ACC. Finally, comparison of Ca 2+ responses elicited by NEP trains in ACC in situ to those evoked by such trains in ACC in vitro revealed that the native tissue environment promotes more highly synchronized Ca 2+ responses. Together, these results lay the foundation for future studies exploring the potential for NEP to modulate catecholamine release from ACC remotely and non‐invasively in vivo. image
- 21 June 2024
- Published by Elsevier in Biophysical Journal
- Vol. 123 (16) , 2537-2556
Modulating Ca2+ influx into adrenal chromaffin cells with short-duration nanosecond electric pulses
- 21 June 2024
- Published by Elsevier in Biophysical Journal
- Vol. 123 (16) , 2537-2556
Modulating Ca2+ influx into adrenal chromaffin cells with short-duration nanosecond electric pulses
- 1 August 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 140, 107830
5 ns electric pulses induce Ca2+-dependent exocytotic release of catecholamine from adrenal chromaffin cells
- 1 August 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 140, 107830
5 ns electric pulses induce Ca2+-dependent exocytotic release of catecholamine from adrenal chromaffin cells
- Open Access
- 1 February 2021
- Published by Elsevier in Biophysical Journal
- Vol. 120 (3) , 556-567
2-ns Electrostimulation of Ca2+ Influx into Chromaffin Cells: Rapid Modulation by Field Reversal
- 1 February 2021
- Published by Elsevier in Biophysical Journal
- Vol. 120 (3) , 556-567
Open Access2-ns Electrostimulation of Ca2+ Influx into Chromaffin Cells: Rapid Modulation by Field Reversal
- 1 June 2019
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1861 (6) , 1180-1188
Ultrashort nanosecond electric pulses evoke heterogeneous patterns of Ca2+ release from the endoplasmic reticulum of adrenal chromaffin cells
- 1 June 2019
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1861 (6) , 1180-1188
Ultrashort nanosecond electric pulses evoke heterogeneous patterns of Ca2+ release from the endoplasmic reticulum of adrenal chromaffin cells
- 1 February 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 119, 84-91
Dielectric properties of isolated adrenal chromaffin cells determined by microfluidic impedance spectroscopy
- 1 February 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 119, 84-91
Dielectric properties of isolated adrenal chromaffin cells determined by microfluidic impedance spectroscopy
- 24 August 2017
- Published by Springer Nature in The Journal of Membrane Biology
- Vol. 250 (5) , 535-552
Adrenal Chromaffin Cells Exposed to 5-ns Pulses Require Higher Electric Fields to Porate Intracellular Membranes than the Plasma Membrane: An Experimental and Modeling Study
Nanosecond-duration electric pulses (NEPs) can permeabilize the endoplasmic reticulum (ER), causing release of Ca2+ into the cytoplasm. This study used experimentation coupled with numerical modeling to understand the lack of Ca2+ mobilization from Ca2+-storing organelles in catecholamine-secreting adrenal chromaffin cells exposed to 5-ns pulses. Fluorescence imaging determined a threshold electric (E) field of 8 MV/m for mobilizing intracellular Ca2+ whereas whole-cell recordings of membrane conductance determined a threshold E-field of 3 MV/m for causing plasma membrane permeabilization. In contrast, a 2D numerical model of a chromaffin cell, which was constructed with internal structures representing a nucleus, mitochondrion, ER, and secretory granule, predicted that exposing the cell to the same 5-ns pulse electroporated the plasma and ER membranes at the same E-field amplitude, 3–4 MV/m. Agreement of the numerical simulations with the experimental results was obtained only when the ER interior conductivity was 30-fold lower than that of the cytoplasm and the ER membrane permittivity was twice that of the plasma membrane. A more realistic intracellular geometry for chromaffin cells in which structures representing multiple secretory granules and an ER showed slight differences in the thresholds necessary to porate the membranes of the secretory granules. We conclude that more sophisticated cell models together with knowledge of accurate dielectric properties are needed to understand the effects of NEPs on intracellular membranes in chromaffin cells, information that will be important for elucidating how NEPs porate organelle membranes in other cell types having a similarly complex cytoplasmic ultrastructure.
- 24 August 2017
- Published by Springer Nature in The Journal of Membrane Biology
- Vol. 250 (5) , 535-552
Adrenal Chromaffin Cells Exposed to 5-ns Pulses Require Higher Electric Fields to Porate Intracellular Membranes than the Plasma Membrane: An Experimental and Modeling Study
Nanosecond-duration electric pulses (NEPs) can permeabilize the endoplasmic reticulum (ER), causing release of Ca2+ into the cytoplasm. This study used experimentation coupled with numerical modeling to understand the lack of Ca2+ mobilization from Ca2+-storing organelles in catecholamine-secreting adrenal chromaffin cells exposed to 5-ns pulses. Fluorescence imaging determined a threshold electric (E) field of 8 MV/m for mobilizing intracellular Ca2+ whereas whole-cell recordings of membrane conductance determined a threshold E-field of 3 MV/m for causing plasma membrane permeabilization. In contrast, a 2D numerical model of a chromaffin cell, which was constructed with internal structures representing a nucleus, mitochondrion, ER, and secretory granule, predicted that exposing the cell to the same 5-ns pulse electroporated the plasma and ER membranes at the same E-field amplitude, 3–4 MV/m. Agreement of the numerical simulations with the experimental results was obtained only when the ER interior conductivity was 30-fold lower than that of the cytoplasm and the ER membrane permittivity was twice that of the plasma membrane. A more realistic intracellular geometry for chromaffin cells in which structures representing multiple secretory granules and an ER showed slight differences in the thresholds necessary to porate the membranes of the secretory granules. We conclude that more sophisticated cell models together with knowledge of accurate dielectric properties are needed to understand the effects of NEPs on intracellular membranes in chromaffin cells, information that will be important for elucidating how NEPs porate organelle membranes in other cell types having a similarly complex cytoplasmic ultrastructure.
- 13 April 2016
- Published by Springer Nature in The Journal of Membrane Biology
- Vol. 249 (5) , 633-644
Enhanced Monitoring of Nanosecond Electric Pulse-Evoked Membrane Conductance Changes in Whole-Cell Patch Clamp Experiments
Patch clamp electrophysiology serves as a powerful method for studying changes in plasma membrane ion conductance induced by externally applied high-intensity nanosecond electric pulses (NEPs). This paper describes an enhanced monitoring technique that minimizes the length of time between pulse exposure and data recording in a patch-clamped excitable cell. Whole-cell membrane currents were continuously recorded up to 11 ms before and resumed 8 ms after delivery of a 5-ns, 6 MV/m pulse by a pair of tungsten rod electrodes to a patched adrenal chromaffin cell maintained at a holding potential of −70 mV. This timing was achieved by two sets of relay switches. One set was used to disconnect the patch pipette electrode from the pre-amplifier and connect it to a battery to maintain membrane potential at −70 mV, and also to disconnect the reference electrode from the amplifier. The other set was used to disconnect the electrodes from the pulse generator until the time of NEP/sham exposure. The sequence and timing of both sets of relays were computer-controlled. Using this procedure, we observed that a 5-ns pulse induced an instantaneous inward current that decayed exponentially over the course of several minutes, that a second pulse induced a similar response, and that the current was carried, at least in part, by Na+. This approach for characterizing ion conductance changes in an excitable cell in response to NEPs will yield information essential for assessing the potential use of NEP stimulation for therapeutic applications.
- 13 April 2016
- Published by Springer Nature in The Journal of Membrane Biology
- Vol. 249 (5) , 633-644
Enhanced Monitoring of Nanosecond Electric Pulse-Evoked Membrane Conductance Changes in Whole-Cell Patch Clamp Experiments
Patch clamp electrophysiology serves as a powerful method for studying changes in plasma membrane ion conductance induced by externally applied high-intensity nanosecond electric pulses (NEPs). This paper describes an enhanced monitoring technique that minimizes the length of time between pulse exposure and data recording in a patch-clamped excitable cell. Whole-cell membrane currents were continuously recorded up to 11 ms before and resumed 8 ms after delivery of a 5-ns, 6 MV/m pulse by a pair of tungsten rod electrodes to a patched adrenal chromaffin cell maintained at a holding potential of −70 mV. This timing was achieved by two sets of relay switches. One set was used to disconnect the patch pipette electrode from the pre-amplifier and connect it to a battery to maintain membrane potential at −70 mV, and also to disconnect the reference electrode from the amplifier. The other set was used to disconnect the electrodes from the pulse generator until the time of NEP/sham exposure. The sequence and timing of both sets of relays were computer-controlled. Using this procedure, we observed that a 5-ns pulse induced an instantaneous inward current that decayed exponentially over the course of several minutes, that a second pulse induced a similar response, and that the current was carried, at least in part, by Na+. This approach for characterizing ion conductance changes in an excitable cell in response to NEPs will yield information essential for assessing the potential use of NEP stimulation for therapeutic applications.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Enhancing measurement accuracy of position sensitive detector (PSD) systems using the Kalman filter and distortion rectifying
Factors affecting measurement accuracy of Position Sensitive Detector (PSD) systems consist of inaccuracies caused by interface circuits, system connection, outside environment change, and the semi-conductive properties of the sensor. The presence of these factors causes noises and distortions that are interpreted as a valid signal by the PSD system. As a result, these inaccuracies heavily degrade the PSD performance and hamper the measurement resolution and accuracy of the PSD system, which greatly limit its applications in micro/nano positioning systems. Our work is to (1) design a Kalman filter for the system that is used to recursively and optimally estimate the laser spot position value of the modeled second-order linear lateral effect PSD sensing system from a series of measurements mixed with these noises and (2) develop a distortion rectifying methodology to collect pincushion-type radial distortion associated with the lateral effect PSD systems, so as to enhance measurement accuracy in a larger active area of the PSD. After implementation, both the developed Kalman filter and distortion rectifying algorithm can greatly improve the measurement accuracy of the PSD systems. It will be very useful in a wide variety of applications that use a PSD embedded system.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Enhancing measurement accuracy of position sensitive detector (PSD) systems using the Kalman filter and distortion rectifying
Factors affecting measurement accuracy of Position Sensitive Detector (PSD) systems consist of inaccuracies caused by interface circuits, system connection, outside environment change, and the semi-conductive properties of the sensor. The presence of these factors causes noises and distortions that are interpreted as a valid signal by the PSD system. As a result, these inaccuracies heavily degrade the PSD performance and hamper the measurement resolution and accuracy of the PSD system, which greatly limit its applications in micro/nano positioning systems. Our work is to (1) design a Kalman filter for the system that is used to recursively and optimally estimate the laser spot position value of the modeled second-order linear lateral effect PSD sensing system from a series of measurements mixed with these noises and (2) develop a distortion rectifying methodology to collect pincushion-type radial distortion associated with the lateral effect PSD systems, so as to enhance measurement accuracy in a larger active area of the PSD. After implementation, both the developed Kalman filter and distortion rectifying algorithm can greatly improve the measurement accuracy of the PSD systems. It will be very useful in a wide variety of applications that use a PSD embedded system.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1892-1895
Development of an optical surface characterization sensor for simultaneously measuring both 3-D surface texture and mechanical properties
Current surface characterization technologies are generally sorted into two categories: non-contact and contact-based technologies. Among these technologies, no one can stand out to simultaneously and rapidly measure both surface patterns/textures and mechanical properties such as softness, friction, and mechanical impedance. Our work addresses this problem, through combination of both contact and non-contact optical surface profiling mechanisms, the developed new optical Total Internal Reflection (TIR) based surface texture sensor can be efficiently used for quantitative characterization of surface texture properties including 3-D texture pattern, roughness, and even mechanical properties like softness, etc. We have used this sensor to measure and analyze texture properties of extensive sample surfaces of soft materials. The results demonstrate the high performance of the sensor.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1892-1895
Development of an optical surface characterization sensor for simultaneously measuring both 3-D surface texture and mechanical properties
Current surface characterization technologies are generally sorted into two categories: non-contact and contact-based technologies. Among these technologies, no one can stand out to simultaneously and rapidly measure both surface patterns/textures and mechanical properties such as softness, friction, and mechanical impedance. Our work addresses this problem, through combination of both contact and non-contact optical surface profiling mechanisms, the developed new optical Total Internal Reflection (TIR) based surface texture sensor can be efficiently used for quantitative characterization of surface texture properties including 3-D texture pattern, roughness, and even mechanical properties like softness, etc. We have used this sensor to measure and analyze texture properties of extensive sample surfaces of soft materials. The results demonstrate the high performance of the sensor.