Alexander Moiseev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander Moiseev has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Grigory V. Gelikonov
A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanova Street, 603950 Nizhny Novgorod, Russia
14 shared publications - Natalia D. Gladkova
Institute of Experimental Oncology and Biomedical Technologies, Privolzhsky Research Medical University, 603950 Nizhny Novgorod, Russia
14 shared publications - Elena Borisovna Kiseleva
Institute of Experimental Oncology and Biomedical Technologies, Privolzhsky Research Medical University, 603950 Nizhny Novgorod, Russia
11 shared publications - Pavel A. Shilyagin
Institute of Applied Physics of the Russian Academy of Sciences
9 shared publications - Vladimir Yu. Zaitsev
Russian Academy of Sciences, 119334 Moscow, Russia
9 shared publications - Lev A. Matveev
A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, Uljanova St. 46, 603950 Nizhny Novgorod, Russia
8 shared publications
Latest Publications
- Open Access
Method of Tissue Differentiation Based on Changes in Tissue Optical Properties Under Mechanical Stress Estimated with Optical Coherence Tomography
This study highlights the possibility of contrasting the differences in tissues’ mechanical properties from Optical Coherence Tomography (OCT) data without maintaining phase stability during OCT data acquisition. The proposed method is based on the rate of attenuation coefficient changes under the mechanical pressure evaluation of the OCT data. It was shown, both on the calibrated synthetic and ex vivo biological samples, that the rate of attenuation coefficient changes observed corresponds to the sample’s mechanical properties and could be used to characterize the sample and distinguish it from other samples even if their optical properties before the pressure application are similar. This opens up the possibility to use an in vivo OCT-based system that can contrast mechanical properties without ensuring phase stability.
Open AccessMethod of Tissue Differentiation Based on Changes in Tissue Optical Properties Under Mechanical Stress Estimated with Optical Coherence Tomography
This study highlights the possibility of contrasting the differences in tissues’ mechanical properties from Optical Coherence Tomography (OCT) data without maintaining phase stability during OCT data acquisition. The proposed method is based on the rate of attenuation coefficient changes under the mechanical pressure evaluation of the OCT data. It was shown, both on the calibrated synthetic and ex vivo biological samples, that the rate of attenuation coefficient changes observed corresponds to the sample’s mechanical properties and could be used to characterize the sample and distinguish it from other samples even if their optical properties before the pressure application are similar. This opens up the possibility to use an in vivo OCT-based system that can contrast mechanical properties without ensuring phase stability.
- Open Access
- 25 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2131
Quantitative Assessment of Polarization and Elastic Properties of Endometrial Tissue for Precancer/Cancer Diagnostics Using Multimodal Optical Coherence Tomography
Objectives: The most important phase in the endometrial pathologies diagnostics is the histological examination of tissue biopsies obtained under visual hysteroscopic control. However, the unclear visual diagnostics characteristics of subtle focal endometrial pathologies often lead to selection errors regarding suspicious endometrial lesions and to a subsequent false pathological diagnosis/underestimation of precancer or early-stage cancer. Methods: In this study, we investigate the potential of Multimodal Optical Coherence Tomography (MM OCT) to verify suspicious endometrial lesion regions before biopsy collection. We study the polarization (by cross-polarization OCT, CP OCT) and elastic (by compression OCT-elastography, C-OCE) properties of ex vivo endometrial tissue samples in normal conditions (proliferative and secretory phases to the menstrual cycle, atrophic endometrium) with endometrial hyperplasia (non-atypical and endometrial intraepithelial neoplasia) and endometrial cancer subtypes (low-grade, high-grade, clear cell and serous). Results: To the best of our knowledge, this is the first quantitative assessment of relevant OCT parameters (depth-resolved attenuation coefficient in co-[Att(co) values] and cross-[(Att(cross) values] polarizations and Young’s elastic modulus [stiffness values]) for the selection of the most objective criteria to identify the clinically significant endometrial pathologies: endometrial intraepithelial neoplasia and endometrial cancer. The study demonstrates the possibility of detecting endometrial pathologies and establishing optimal threshold values of MM OCT criteria for the identification of endometrial cancer using CP OCT (by Att(co) values = 3.69 mm−1, Sensitivity (Se) = 86.1%, Specificity (Sp) = 92.6%; by Att(cross) values = 2.27 mm−1, Se = 86.8%, Sp = 87.0%) and C-OCE (by stiffness values = 122 kPa, Se = 93.2%, Sp = 91.1%). The study also differentiates endometrial intraepithelial neoplasia from non-atypical endometrial hyperplasia and normal endometrium using C-OCE (by stiffness values = 95 kPa, Se = 87.2%, Sp = 90.1%). Conclusions: The results are indicative of the efficacy and potential of clinical implementation of in vivo hysteroscopic-like MM OCT in the diagnosis of endometrial pathologies.
- 25 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2131
Open AccessQuantitative Assessment of Polarization and Elastic Properties of Endometrial Tissue for Precancer/Cancer Diagnostics Using Multimodal Optical Coherence Tomography
Objectives: The most important phase in the endometrial pathologies diagnostics is the histological examination of tissue biopsies obtained under visual hysteroscopic control. However, the unclear visual diagnostics characteristics of subtle focal endometrial pathologies often lead to selection errors regarding suspicious endometrial lesions and to a subsequent false pathological diagnosis/underestimation of precancer or early-stage cancer. Methods: In this study, we investigate the potential of Multimodal Optical Coherence Tomography (MM OCT) to verify suspicious endometrial lesion regions before biopsy collection. We study the polarization (by cross-polarization OCT, CP OCT) and elastic (by compression OCT-elastography, C-OCE) properties of ex vivo endometrial tissue samples in normal conditions (proliferative and secretory phases to the menstrual cycle, atrophic endometrium) with endometrial hyperplasia (non-atypical and endometrial intraepithelial neoplasia) and endometrial cancer subtypes (low-grade, high-grade, clear cell and serous). Results: To the best of our knowledge, this is the first quantitative assessment of relevant OCT parameters (depth-resolved attenuation coefficient in co-[Att(co) values] and cross-[(Att(cross) values] polarizations and Young’s elastic modulus [stiffness values]) for the selection of the most objective criteria to identify the clinically significant endometrial pathologies: endometrial intraepithelial neoplasia and endometrial cancer. The study demonstrates the possibility of detecting endometrial pathologies and establishing optimal threshold values of MM OCT criteria for the identification of endometrial cancer using CP OCT (by Att(co) values = 3.69 mm−1, Sensitivity (Se) = 86.1%, Specificity (Sp) = 92.6%; by Att(cross) values = 2.27 mm−1, Se = 86.8%, Sp = 87.0%) and C-OCE (by stiffness values = 122 kPa, Se = 93.2%, Sp = 91.1%). The study also differentiates endometrial intraepithelial neoplasia from non-atypical endometrial hyperplasia and normal endometrium using C-OCE (by stiffness values = 95 kPa, Se = 87.2%, Sp = 90.1%). Conclusions: The results are indicative of the efficacy and potential of clinical implementation of in vivo hysteroscopic-like MM OCT in the diagnosis of endometrial pathologies.
- 20 September 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (11) , e202400318
The Effect of Cryotherapy on Buccal Blood Vessels Evaluated by Optical Coherence Tomography Angiography: A Pilot Study
While cryotherapy is one of the traditional ways to reduce postoperative complications in maxillofacial surgery, the cooling degree is not regulated in most cases and the achieved effect is not properly controlled. Therefore, to develop optimal cooling modes, we propose to study the buccal vascular response to cooling, which has not been previously shown. To evaluate the effect of cooling, we analyzed vessel networks using optical coherence tomography angiography (OCT‐A). The cheek vessels were OCT‐A monitored using cooling by an ice bag/cooling mask. We found the advantages of using a cooling mask over an ice bag consist of a statistically significant decrease in the perfused vessel density (PVD) of the papillary layer at the oral mucosa. The absence of the reticular layer vessel reaction to any type of cooling was noted. We argue for the necessity to develop optimal modes of cryotherapy, which will contribute to blood perfusion reduction and reduction of PVD recovery.
- 20 September 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (11) , e202400318
The Effect of Cryotherapy on Buccal Blood Vessels Evaluated by Optical Coherence Tomography Angiography: A Pilot Study
While cryotherapy is one of the traditional ways to reduce postoperative complications in maxillofacial surgery, the cooling degree is not regulated in most cases and the achieved effect is not properly controlled. Therefore, to develop optimal cooling modes, we propose to study the buccal vascular response to cooling, which has not been previously shown. To evaluate the effect of cooling, we analyzed vessel networks using optical coherence tomography angiography (OCT‐A). The cheek vessels were OCT‐A monitored using cooling by an ice bag/cooling mask. We found the advantages of using a cooling mask over an ice bag consist of a statistically significant decrease in the perfused vessel density (PVD) of the papillary layer at the oral mucosa. The absence of the reticular layer vessel reaction to any type of cooling was noted. We argue for the necessity to develop optimal modes of cryotherapy, which will contribute to blood perfusion reduction and reduction of PVD recovery.
- 22 January 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (4) , e202300458
Detection of acute and early‐delayed radiation‐induced changes in the white matter of the rat brain based on numerical processing of optical coherence tomography data
Detection of radiation‐induced changes of the brain white matter is important for brain neoplasms repeated surgery. We investigated the influence of irradiation on the scattering properties of the white matter using optical coherence tomography (OCT). Healthy Wistar rats undergone the irradiation of the brain right hemisphere. At seven time points from the irradiation procedure (2–14 weeks), an ex vivo OCT study was performed with subsequent calculation of attenuation coefficient values in the corpus callosum followed by immunohistochemical analysis. As a result, we discovered acute and early‐delayed changes characterized by the edema of different severity, accompanied by a statistically significant decrease in attenuation coefficient values. In particular, these changes were found at 2 weeks after irradiation in the irradiated hemisphere, while at 6‐ and 12‐week time points they affected both irradiated and contralateral hemisphere. Thus, radiation‐induced changes occurring in white matter during the first 3 months after irradiation can be detected by OCT.
- 22 January 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (4) , e202300458
Detection of acute and early‐delayed radiation‐induced changes in the white matter of the rat brain based on numerical processing of optical coherence tomography data
Detection of radiation‐induced changes of the brain white matter is important for brain neoplasms repeated surgery. We investigated the influence of irradiation on the scattering properties of the white matter using optical coherence tomography (OCT). Healthy Wistar rats undergone the irradiation of the brain right hemisphere. At seven time points from the irradiation procedure (2–14 weeks), an ex vivo OCT study was performed with subsequent calculation of attenuation coefficient values in the corpus callosum followed by immunohistochemical analysis. As a result, we discovered acute and early‐delayed changes characterized by the edema of different severity, accompanied by a statistically significant decrease in attenuation coefficient values. In particular, these changes were found at 2 weeks after irradiation in the irradiated hemisphere, while at 6‐ and 12‐week time points they affected both irradiated and contralateral hemisphere. Thus, radiation‐induced changes occurring in white matter during the first 3 months after irradiation can be detected by OCT.
- Open Access
- 20 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3487
Depth-Resolved Attenuation Mapping of the Vaginal Wall under Prolapse and after Laser Treatment Using Cross-Polarization Optical Coherence Tomography: A Pilot Study
Vaginal wall prolapse is the most common type of pelvic organ prolapse and is mainly associated with collagen bundle changes in the lamina propria. Neodymium (Nd:YAG) laser treatment was used as an innovative, minimally invasive and non-ablative procedure for the treatment of early-stage vaginal wall prolapse. The purpose of this pilot study was to assess connective tissue changes in the vaginal wall under prolapse without treatment and after Nd:YAG laser treatment using cross-polarization optical coherence tomography (CP OCT) with depth-resolved attenuation mapping. A total of 26 freshly excised samples of vaginal wall from 26 patients with age norm (n = 8), stage I–II prolapses without treatment (n = 8) and stage I–II prolapse 1–2 months after Nd:YAG laser treatment (n = 10) were assessed. As a result, for the first time, depth-resolved attenuation maps of the vaginal wall in the B-scan projection in the co- and cross-polarization channels were constructed. Two parameters within the lamina propria were target calculated: the median value and the percentages of high (≥4 mm−1) and low (−1) attenuation coefficient values. A significant (p < 0.0001) decrease in the parameters in the case of vaginal wall prolapse compared to the age norm was identified. After laser treatment, a significant (p < 0.0001) increase in the parameters compared to the normal level was also observed. Notably, in the cross-channel, both parameters showed a greater difference between the groups than in the co-channel. Therefore, using the cross-channel achieved more reliable differentiation between the groups. To conclude, attenuation coefficient maps allow visualization and quantification of changes in the condition of the connective tissue of the vaginal wall. In the future, CP OCT could be used for in vivo detection of early-stage vaginal wall prolapse and for monitoring the effectiveness of treatment.
- 20 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3487
Open AccessDepth-Resolved Attenuation Mapping of the Vaginal Wall under Prolapse and after Laser Treatment Using Cross-Polarization Optical Coherence Tomography: A Pilot Study
Vaginal wall prolapse is the most common type of pelvic organ prolapse and is mainly associated with collagen bundle changes in the lamina propria. Neodymium (Nd:YAG) laser treatment was used as an innovative, minimally invasive and non-ablative procedure for the treatment of early-stage vaginal wall prolapse. The purpose of this pilot study was to assess connective tissue changes in the vaginal wall under prolapse without treatment and after Nd:YAG laser treatment using cross-polarization optical coherence tomography (CP OCT) with depth-resolved attenuation mapping. A total of 26 freshly excised samples of vaginal wall from 26 patients with age norm (n = 8), stage I–II prolapses without treatment (n = 8) and stage I–II prolapse 1–2 months after Nd:YAG laser treatment (n = 10) were assessed. As a result, for the first time, depth-resolved attenuation maps of the vaginal wall in the B-scan projection in the co- and cross-polarization channels were constructed. Two parameters within the lamina propria were target calculated: the median value and the percentages of high (≥4 mm−1) and low (−1) attenuation coefficient values. A significant (p < 0.0001) decrease in the parameters in the case of vaginal wall prolapse compared to the age norm was identified. After laser treatment, a significant (p < 0.0001) increase in the parameters compared to the normal level was also observed. Notably, in the cross-channel, both parameters showed a greater difference between the groups than in the co-channel. Therefore, using the cross-channel achieved more reliable differentiation between the groups. To conclude, attenuation coefficient maps allow visualization and quantification of changes in the condition of the connective tissue of the vaginal wall. In the future, CP OCT could be used for in vivo detection of early-stage vaginal wall prolapse and for monitoring the effectiveness of treatment.
- Open Access
- 12 September 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (18) , 13967
Multimodal OCT Control for Early Histological Signs of Vulvar Lichen Sclerosus Recurrence after Systemic PDT: Pilot Study
Photodynamic therapy (PDT) is a modern treatment for severe or treatment-resistant vulvar lichen sclerosus (VLS). The chronic and recurrent nature of VLS requires control of recurrences at an early stage. In this paper, a non-invasive multimodal optical coherence tomography (OCT) method was used to control for early histological signs of VLS recurrence after systemic PDT using Photodithazine®. To interpret the OCT data, a histological examination was performed before PDT and 3 months after PDT. Two groups of patients were identified: with early histological signs of VLS recurrence (Group I, n = 5) and without histological signs of VLS recurrence (Group II, n = 6). We use structural OCT, OCT angiography, and OCT lymphangiography throughout 6 months after PDT to visually assess the skin components and to quantitatively assess the dermis by calculating the depth-resolved attenuation coefficient and the density of blood and lymphatic vessels. The OCT data assessment showed a statistically significant difference between the patient groups 3 months after PDT. In Group II, all the studied OCT parameters reached maximum values by the 3rd month after PDT, which indicated recovery of the skin structure. At the same time, in Group I, the values of OCT parameters did not approach the values those in Group II even after 6 months. The obtained results of multimodal OCT can be used for non-invasive control of early histological recurrence of VLS after systemic PDT and for adjusting treatment tactics in advance, without waiting for new clinical manifestations of the disease.
- 12 September 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (18) , 13967
Open AccessMultimodal OCT Control for Early Histological Signs of Vulvar Lichen Sclerosus Recurrence after Systemic PDT: Pilot Study
Photodynamic therapy (PDT) is a modern treatment for severe or treatment-resistant vulvar lichen sclerosus (VLS). The chronic and recurrent nature of VLS requires control of recurrences at an early stage. In this paper, a non-invasive multimodal optical coherence tomography (OCT) method was used to control for early histological signs of VLS recurrence after systemic PDT using Photodithazine®. To interpret the OCT data, a histological examination was performed before PDT and 3 months after PDT. Two groups of patients were identified: with early histological signs of VLS recurrence (Group I, n = 5) and without histological signs of VLS recurrence (Group II, n = 6). We use structural OCT, OCT angiography, and OCT lymphangiography throughout 6 months after PDT to visually assess the skin components and to quantitatively assess the dermis by calculating the depth-resolved attenuation coefficient and the density of blood and lymphatic vessels. The OCT data assessment showed a statistically significant difference between the patient groups 3 months after PDT. In Group II, all the studied OCT parameters reached maximum values by the 3rd month after PDT, which indicated recovery of the skin structure. At the same time, in Group I, the values of OCT parameters did not approach the values those in Group II even after 6 months. The obtained results of multimodal OCT can be used for non-invasive control of early histological recurrence of VLS after systemic PDT and for adjusting treatment tactics in advance, without waiting for new clinical manifestations of the disease.
- 11 September 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 16 (12) , e202100392
Depth‐resolved method for attenuation coefficient calculation from optical coherence tomography data for improved biological structure visualization
Optical coherence tomography (OCT) is a promising tool for intraoperative tissue morphology determination. Several studies suggest that attenuation coefficient derived from the OCT images, can differentiate between tissues of different morphology, such as normal and pathological structures of the brain, skin, and other tissues. In the present study, the depth‐resolved method for attenuation coefficient calculation was adopted for the real‐world situation of the depth‐dependent OCT sensitivity and additive imaging noise with nonzero mean. It was shown that in the case of sharp focusing (~10 μm spot full width at half maximum [FWHM] or smaller at 1.3 μm central wavelength) only the proposed method for depth‐dependent sensitivity compensation does not introduce misleading artifacts into the calculated attenuation coefficient distribution. At the same time, the scanning beam focus spot with FWHM greater than 10 μm at 1.3 μm central wavelength allows one to use multiple approaches to the attenuation coefficient calculation without introducing noticeable bias. This feature may hinder the need for robust corrections for the depth‐resolved attenuation coefficient estimations from the community.
- 11 September 2023
- Published by Wiley in Journal of Biophotonics
- Vol. 16 (12) , e202100392
Depth‐resolved method for attenuation coefficient calculation from optical coherence tomography data for improved biological structure visualization
Optical coherence tomography (OCT) is a promising tool for intraoperative tissue morphology determination. Several studies suggest that attenuation coefficient derived from the OCT images, can differentiate between tissues of different morphology, such as normal and pathological structures of the brain, skin, and other tissues. In the present study, the depth‐resolved method for attenuation coefficient calculation was adopted for the real‐world situation of the depth‐dependent OCT sensitivity and additive imaging noise with nonzero mean. It was shown that in the case of sharp focusing (~10 μm spot full width at half maximum [FWHM] or smaller at 1.3 μm central wavelength) only the proposed method for depth‐dependent sensitivity compensation does not introduce misleading artifacts into the calculated attenuation coefficient distribution. At the same time, the scanning beam focus spot with FWHM greater than 10 μm at 1.3 μm central wavelength allows one to use multiple approaches to the attenuation coefficient calculation without introducing noticeable bias. This feature may hinder the need for robust corrections for the depth‐resolved attenuation coefficient estimations from the community.
- 31 May 2023
- Published by IOP Publishing in Laser Physics Letters
- Vol. 20 (7) , 075601
Depth-resolved attenuation coefficient estimation from optical coherence tomography data in case of incomplete signal attenuation in the imaging depth range
Attenuation coefficient estimation from optical coherent tomography (OCT) data is one of the emerging methods for additional information extraction from the OCT data. With the reasonable assumptions of uniform proportion of the light, scattered backwards, relative to the light, scattered in all directions and the assumption of complete light attenuation within the imaging depth range, the attenuation coefficient can be estimated in every pixel of the OCT data volume, i.e. with the depth resolution. In the present paper the numerically effective method for lifting the second assumption was proposed. With numerical simulations and experiments it was shown, that the proposed method allows attenuation coefficient estimation even if OCT signal was not completely attenuated within the imaging depth range. Since the proposed method lifts one of the requirements for depth-resolved attenuation coefficient estimation, it allows the extension of the depth-resolved attenuation estimation method to the new applications.
- 31 May 2023
- Published by IOP Publishing in Laser Physics Letters
- Vol. 20 (7) , 075601
Depth-resolved attenuation coefficient estimation from optical coherence tomography data in case of incomplete signal attenuation in the imaging depth range
Attenuation coefficient estimation from optical coherent tomography (OCT) data is one of the emerging methods for additional information extraction from the OCT data. With the reasonable assumptions of uniform proportion of the light, scattered backwards, relative to the light, scattered in all directions and the assumption of complete light attenuation within the imaging depth range, the attenuation coefficient can be estimated in every pixel of the OCT data volume, i.e. with the depth resolution. In the present paper the numerically effective method for lifting the second assumption was proposed. With numerical simulations and experiments it was shown, that the proposed method allows attenuation coefficient estimation even if OCT signal was not completely attenuated within the imaging depth range. Since the proposed method lifts one of the requirements for depth-resolved attenuation coefficient estimation, it allows the extension of the depth-resolved attenuation estimation method to the new applications.
- Open Access
Intraoperative Assessment of Breast Cancer Tissues after Breast-Conserving Surgery Based on Mapping the Attenuation Coefficients in 3D Cross-Polarization Optical Coherence Tomography
Intraoperative differentiation of tumorous from non-tumorous tissue can help in the assessment of resection margins in breast cancer and its response to therapy and, potentially, reduce the incidence of tumor recurrence. In this study, the calculation of the attenuation coefficient and its color-coded 2D distribution was performed for different breast cancer subtypes using spectral-domain CP OCT. A total of 68 freshly excised human breast specimens containing tumorous and surrounding non-tumorous tissues after BCS was studied. Immediately after obtaining structural 3D CP OCT images, en face color-coded attenuation coefficient maps were built in co-(Att(co)) and cross-(Att(cross)) polarization channels using a depth-resolved approach to calculating the values in each A-scan. We determined spatially localized signal attenuation in both channels and reported ranges of attenuation coefficients to five selected breast tissue regions (adipose tissue, non-tumorous fibrous connective tissue, hyalinized tumor stroma, low-density tumor cells in the fibrotic tumor stroma and high-density clusters of tumor cells). The Att(cross) coefficient exhibited a stronger gain contrast of studied tissues compared to the Att(co) coefficient (i.e., conventional attenuation coefficient) and, therefore, allowed improved differentiation of all breast tissue types. It has been shown that color-coded attenuation coefficient maps may be used to detect inter- and intra-tumor heterogeneity of various breast cancer subtypes as well as to assess the effectiveness of therapy. For the first time, the optimal threshold values of the attenuation coefficients to differentiate tumorous from non-tumorous breast tissues were determined. Diagnostic testing values for Att(cross) coefficient were higher for differentiation of tumor cell areas and tumor stroma from non-tumorous fibrous connective tissue: diagnostic accuracy was 91–99%, sensitivity—96–98%, and specificity—87–99%. Att(co) coefficient is more suitable for the differentiation of tumor cell areas from adipose tissue: diagnostic accuracy was 83%, sensitivity—84%, and specificity—84%. Therefore, the present study provides a new diagnostic approach to the differentiation of breast cancer tissue types based on the assessment of the attenuation coefficient from real-time CP OCT data and has the potential to be used for further rapid and accurate intraoperative assessment of the resection margins during BCS.
Open AccessIntraoperative Assessment of Breast Cancer Tissues after Breast-Conserving Surgery Based on Mapping the Attenuation Coefficients in 3D Cross-Polarization Optical Coherence Tomography
Intraoperative differentiation of tumorous from non-tumorous tissue can help in the assessment of resection margins in breast cancer and its response to therapy and, potentially, reduce the incidence of tumor recurrence. In this study, the calculation of the attenuation coefficient and its color-coded 2D distribution was performed for different breast cancer subtypes using spectral-domain CP OCT. A total of 68 freshly excised human breast specimens containing tumorous and surrounding non-tumorous tissues after BCS was studied. Immediately after obtaining structural 3D CP OCT images, en face color-coded attenuation coefficient maps were built in co-(Att(co)) and cross-(Att(cross)) polarization channels using a depth-resolved approach to calculating the values in each A-scan. We determined spatially localized signal attenuation in both channels and reported ranges of attenuation coefficients to five selected breast tissue regions (adipose tissue, non-tumorous fibrous connective tissue, hyalinized tumor stroma, low-density tumor cells in the fibrotic tumor stroma and high-density clusters of tumor cells). The Att(cross) coefficient exhibited a stronger gain contrast of studied tissues compared to the Att(co) coefficient (i.e., conventional attenuation coefficient) and, therefore, allowed improved differentiation of all breast tissue types. It has been shown that color-coded attenuation coefficient maps may be used to detect inter- and intra-tumor heterogeneity of various breast cancer subtypes as well as to assess the effectiveness of therapy. For the first time, the optimal threshold values of the attenuation coefficients to differentiate tumorous from non-tumorous breast tissues were determined. Diagnostic testing values for Att(cross) coefficient were higher for differentiation of tumor cell areas and tumor stroma from non-tumorous fibrous connective tissue: diagnostic accuracy was 91–99%, sensitivity—96–98%, and specificity—87–99%. Att(co) coefficient is more suitable for the differentiation of tumor cell areas from adipose tissue: diagnostic accuracy was 83%, sensitivity—84%, and specificity—84%. Therefore, the present study provides a new diagnostic approach to the differentiation of breast cancer tissue types based on the assessment of the attenuation coefficient from real-time CP OCT data and has the potential to be used for further rapid and accurate intraoperative assessment of the resection margins during BCS.
- Open Access
Optical Coherence Tomography Angiography of the Intestine: How to Prevent Motion Artifacts in Open and Laparoscopic Surgery?
(1) Introduction. The problem that limits the intraoperative use of OCTA for the intestinal circulation diagnostics is the low informative value of OCTA images containing too many motion artifacts. The aim of this study is to evaluate the efficiency and safety of the developed unit for the prevention of the appearance of motion artifacts in the OCTA images of the intestine in both open and laparoscopic surgery in the experiment; (2) Methods. A high-speed spectral-domain multimodal optical coherence tomograph (IAP RAS, Russia) operating at a wavelength of 1310 nm with a spectral width of 100 μm and a power of 2 mW was used. The developed unit was tested in two groups of experimental animals—on minipigs (group I, n = 10, open abdomen) and on rabbits (group II, n = 10, laparoscopy). Acute mesenteric ischemia was modeled and then 1 h later the small intestine underwent OCTA evaluation. A total of 400 OCTA images of the intact and ischemic small intestine were obtained and analyzed. The quality of the obtained OCTA images was evaluated based on the score proposed in 2020 by the group of Magnin M. (3) Results. Without stabilization, OCTA images of the intestine tissues were informative only in 32–44% of cases in open surgery and in 14–22% of cases in laparoscopic surgery. A vacuum bowel stabilizer with a pressure deficit of 22–25 mm Hg significantly reduced the number of motion artifacts. As a result, the proportion of informative OCTA images in open surgery increased up to 86.5% (Χ2 = 200.2, p = 0.001), and in laparoscopy up to 60% (Χ2 = 148.3, p = 0.001). (4) Conclusions. The used vacuum tissue stabilizer enabled a significant increase in the proportion of informative OCTA images by significantly reducing the motion artifacts.
Open AccessOptical Coherence Tomography Angiography of the Intestine: How to Prevent Motion Artifacts in Open and Laparoscopic Surgery?
(1) Introduction. The problem that limits the intraoperative use of OCTA for the intestinal circulation diagnostics is the low informative value of OCTA images containing too many motion artifacts. The aim of this study is to evaluate the efficiency and safety of the developed unit for the prevention of the appearance of motion artifacts in the OCTA images of the intestine in both open and laparoscopic surgery in the experiment; (2) Methods. A high-speed spectral-domain multimodal optical coherence tomograph (IAP RAS, Russia) operating at a wavelength of 1310 nm with a spectral width of 100 μm and a power of 2 mW was used. The developed unit was tested in two groups of experimental animals—on minipigs (group I, n = 10, open abdomen) and on rabbits (group II, n = 10, laparoscopy). Acute mesenteric ischemia was modeled and then 1 h later the small intestine underwent OCTA evaluation. A total of 400 OCTA images of the intact and ischemic small intestine were obtained and analyzed. The quality of the obtained OCTA images was evaluated based on the score proposed in 2020 by the group of Magnin M. (3) Results. Without stabilization, OCTA images of the intestine tissues were informative only in 32–44% of cases in open surgery and in 14–22% of cases in laparoscopic surgery. A vacuum bowel stabilizer with a pressure deficit of 22–25 mm Hg significantly reduced the number of motion artifacts. As a result, the proportion of informative OCTA images in open surgery increased up to 86.5% (Χ2 = 200.2, p = 0.001), and in laparoscopy up to 60% (Χ2 = 148.3, p = 0.001). (4) Conclusions. The used vacuum tissue stabilizer enabled a significant increase in the proportion of informative OCTA images by significantly reducing the motion artifacts.