Philipp Quenzel
Research Subjects
Research Interests
Philipp Quenzel has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Kathrin Lang
DKMS Life Science Lab, Dresden, Germany
5 shared publications - Vinzenz Lange
DKMS Life Science Lab, Dresden, Germany
4 shared publications Alexander H. Schmidt
DKMS Life Science Lab, Dresden, Germany
3 shared publications- Gerhard Schöfl
DKMS Life Science Lab, Dresden, Germany
3 shared publications - Jan A. Hofmann
DKMS Tübingen Germany
2 shared publications - Julia Pingel
DKMS, Kressbach 1, 72072, Tübingen, Germany
2 shared publications
Latest Publications
- 2 June 2018
- Published by Springer Nature
- Vol. 1802, 155-162
Full-Length HLA Class I Genotyping with the MinION Nanopore Sequencer
Nanopore sequencing, a paradigm change in sequencing technologies, offers a new cost-effective and scalable platform for HLA genotyping. Among the new generation of high-throughput sequencing technologies, the MinION nanopore sequencer is the first to offer a non-template-based direct DNA sensing sequencing technology. Oxford Nanopore Technologies (ONT) introduced the first version of the MinION in 2014; since then, the platform has gone through multiple iterations resulting in higher throughput and sequencing accuracy. The “what you put in is what you get” nature of the platform enables molecules to be sequenced without fragmentation. This results in ultra-long read lengths in the order of tens of kilobases enabling entire genes to be characterized with fully phased sequence information. With release R9.5, the MinION platform has reached a quality that enables HLA genotyping with minor shortcomings in long homopolymer regions. Within this chapter, we describe a protocol for sequencing and genotyping HLA Class I alleles using the MinION.
- 2 June 2018
- Published by Springer Nature
- Vol. 1802, 155-162
Full-Length HLA Class I Genotyping with the MinION Nanopore Sequencer
Nanopore sequencing, a paradigm change in sequencing technologies, offers a new cost-effective and scalable platform for HLA genotyping. Among the new generation of high-throughput sequencing technologies, the MinION nanopore sequencer is the first to offer a non-template-based direct DNA sensing sequencing technology. Oxford Nanopore Technologies (ONT) introduced the first version of the MinION in 2014; since then, the platform has gone through multiple iterations resulting in higher throughput and sequencing accuracy. The “what you put in is what you get” nature of the platform enables molecules to be sequenced without fragmentation. This results in ultra-long read lengths in the order of tens of kilobases enabling entire genes to be characterized with fully phased sequence information. With release R9.5, the MinION platform has reached a quality that enables HLA genotyping with minor shortcomings in long homopolymer regions. Within this chapter, we describe a protocol for sequencing and genotyping HLA Class I alleles using the MinION.
- Open Access
Accurate typing of class I human leukocyte antigen by Oxford nanopore sequencing
Oxford Nanopore Technologies’ MinION has expanded the current DNA sequencing toolkit by delivering long read lengths and extreme portability. The MinION has the potential to enable expedited point-of-care human leukocyte antigen (HLA) typing, an assay routinely used to assess the immunological compatibility between organ donors and recipients, but the platform’s high error rate makes it challenging to type alleles with clinical-grade accuracy. Here, we developed and validated Athlon, an algorithm that iteratively scores nanopore reads mapped to a hierarchical database of HLA alleles to arrive at a consensus diploid genotype; Athlon achieved a 100% accuracy in class I HLA typing at high resolution.
Open AccessAccurate typing of class I human leukocyte antigen by Oxford nanopore sequencing
Oxford Nanopore Technologies’ MinION has expanded the current DNA sequencing toolkit by delivering long read lengths and extreme portability. The MinION has the potential to enable expedited point-of-care human leukocyte antigen (HLA) typing, an assay routinely used to assess the immunological compatibility between organ donors and recipients, but the platform’s high error rate makes it challenging to type alleles with clinical-grade accuracy. Here, we developed and validated Athlon, an algorithm that iteratively scores nanopore reads mapped to a hierarchical database of HLA alleles to arrive at a consensus diploid genotype; Athlon achieved a 100% accuracy in class I HLA typing at high resolution.
- Open Access
- 14 February 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (1) , 1-16
2.7 million samples genotyped for HLA by next generation sequencing: lessons learned
At the DKMS Life Science Lab, Next Generation Sequencing (NGS) has been used for ultra-high-volume high-resolution genotyping of HLA loci for the last three and a half years. Here, we report on our experiences in genotyping the HLA, CCR5, ABO, RHD and KIR genes using a direct amplicon sequencing approach on Illumina MiSeq and HiSeq 2500 instruments. Between January 2013 and June 2016, 2,714,110 samples largely from German, Polish and UK-based potential stem cell donors have been processed. 98.9% of all alleles for the targeted HLA loci (HLA-A, -B, -C, -DRB1, -DQB1 and -DPB1) were typed at high resolution or better. Initially a simple three-step workflow based on nanofluidic chips in conjunction with 4-primer amplicon tagging was used. Over time, we found that this setup results in PCR artefacts such as primer dimers and PCR-mediated recombination, which may necessitate repeat typing. Split workflows for low- and high-DNA-concentration samples helped alleviate these problems and reduced average per-locus repeat rates from 3.1 to 1.3%. Further optimisations of the workflow included the use of phosphorothioate oligos to reduce primer degradation and primer dimer formation, and employing statistical models to predict read yield from initial template DNA concentration to avoid intermediate quantification of PCR products. Finally, despite the populations typed at DKMS Life Science Lab being relatively homogenous genetically, an analysis of 1.4 million donors processed between January 2015 and May 2016 led to the discovery of 1,919 distinct novel HLA alleles. Amplicon-based NGS HLA genotyping workflows have become the workhorse in high-volume tissue typing of registry donors. The optimisation of workflow practices over multiple years has led to insights and solutions that improve the efficiency and robustness of short amplicon based genotyping workflows.
- 14 February 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (1) , 1-16
Open Access2.7 million samples genotyped for HLA by next generation sequencing: lessons learned
At the DKMS Life Science Lab, Next Generation Sequencing (NGS) has been used for ultra-high-volume high-resolution genotyping of HLA loci for the last three and a half years. Here, we report on our experiences in genotyping the HLA, CCR5, ABO, RHD and KIR genes using a direct amplicon sequencing approach on Illumina MiSeq and HiSeq 2500 instruments. Between January 2013 and June 2016, 2,714,110 samples largely from German, Polish and UK-based potential stem cell donors have been processed. 98.9% of all alleles for the targeted HLA loci (HLA-A, -B, -C, -DRB1, -DQB1 and -DPB1) were typed at high resolution or better. Initially a simple three-step workflow based on nanofluidic chips in conjunction with 4-primer amplicon tagging was used. Over time, we found that this setup results in PCR artefacts such as primer dimers and PCR-mediated recombination, which may necessitate repeat typing. Split workflows for low- and high-DNA-concentration samples helped alleviate these problems and reduced average per-locus repeat rates from 3.1 to 1.3%. Further optimisations of the workflow included the use of phosphorothioate oligos to reduce primer degradation and primer dimer formation, and employing statistical models to predict read yield from initial template DNA concentration to avoid intermediate quantification of PCR products. Finally, despite the populations typed at DKMS Life Science Lab being relatively homogenous genetically, an analysis of 1.4 million donors processed between January 2015 and May 2016 led to the discovery of 1,919 distinct novel HLA alleles. Amplicon-based NGS HLA genotyping workflows have become the workhorse in high-volume tissue typing of registry donors. The optimisation of workflow practices over multiple years has led to insights and solutions that improve the efficiency and robustness of short amplicon based genotyping workflows.
- 1 September 2016
- Published by Elsevier in Human Immunology
- Vol. 77, 33
OR38 Whole gene HLA class I genotyping with the minion nanopore sequencer
- 1 September 2016
- Published by Elsevier in Human Immunology
- Vol. 77, 33
OR38 Whole gene HLA class I genotyping with the minion nanopore sequencer
- 1 April 2015
- Published by Elsevier in Human Immunology
- Vol. 76 (4) , 210
LBOR01