MHMark S. Hunter

Mark S. Hunter

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mark S. Hunter has a total of 283 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Perspectives for pharmaceutical screening at XFEL sources using the example of Lassa virus endonuclease

    by Sven Falke, Patrick Y. A. Reinke, Daniel Rosenberg, Pontus Fischer, Jan Meyer, Marina Galchenkova, Alexandra Tolstikova, Valerio Mariani, Johanna M. Senst, Philipp Lewe, et al.

    Emerging human pathogenic RNA viruses such as Lassa virus (LASV) and closely related viruses such as Hantavirus and Andes virus continue to be a major health threat globally. Treatment options for infections are severely limited. The widely conserved cap-snatching endonuclease of LASV (LASVendoN) is therefore used as an interesting drug target for our X-ray compound-screening experiments. Considering recent improvements in instrumentation and serial crystallography method development, different approaches may be used to facilitate pharmaceutical compound screening. Current-generation X-ray free-electron laser (XFEL) sources hold promise for obtaining higher quality diffraction data and achieving a high sample throughput using fixed-target serial femtosecond X-ray crystallography. We collected serial fixed-target X-ray diffraction data at Linac Coherent Light Source and at the synchrotron source PETRA III for comparison and solved the crystal structures of 2,4-dioxo-4-phenylbutanoic acid (DPBA) and baloxavir acid (BXA) binding to the active site of LASVendoN. These solved structures represent a reasonable starting point for drug development. In addition to room-temperature diffraction data, conventional single-crystal diffraction data were recorded at 100 K for comparison. To analyse the sample throughput in a compound-screening experiment at an XFEL, we further present data for the bacterial fosfomycin-resistance protein A with six ligands previously identified in a synchrotron screening experiment. In summary, the XFEL and synchrotron data-collection approaches have proven to be useful for compound screening with minor differences in achievable data quality and resolution. The individual experimental setup, detector and potentially the use of beam sweeping at XFELs at close-to-physiological temperatures combined with reasonable sample consumption and minimized radiation damage are considered to be advantageous for high-throughput drug development.

  • Open Access

    Macromolecular crystallography and biology at the Linac Coherent Light Source

    by Sandra Mous, Mark S. Hunter, Frédéric Poitevin, Sébastien Boutet, Leland B. Gee

    The Linac Coherent Light Source (LCLS) has significantly impacted the field of biology by providing advanced capabilities for probing the structure and dynamics of biological molecules with high precision. The ultrashort coherent X-ray pulses from the LCLS have enabled ultrafast, time-resolved, serial femtosecond crystallography that is inaccessible at conventional synchrotron light sources. Since the facility's founding, scientists have captured detailed insights into biological processes at atomic resolution and fundamental timescales. The ability to observe these processes in real time and under conditions closely resembling their natural state is transforming our approach to studying biochemical mechanisms and developing new medical and energy applications. This work recounts some of the history of the LCLS, advances in biological research enabled by the LCLS, key biological areas that have been impacted and how the LCLS has helped to unravel complex biological phenomena in these fields.


  • Open Access

    Structural biology in the age of X-ray free-electron lasers and exascale computing

    by Sandra Mous, Frédéric Poitevin, Mark S. Hunter, Dilipkumar N. Asthagiri, Thomas L. Beck


  • Open Access

    Observations of phase changes in monoolein during high viscous injection

    by Daniel J. Wells, Peter Berntsen, Eugeniu Balaur, Cameron M. Kewish, Patrick Adams, Andrew Aquila, Jack Binns, Sébastien Boutet, Hayden Broomhall, Carl Caleman, et al.

    Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.


  • Co-flow injection for serial crystallography at X-ray free-electron lasers

    by Diandra Doppler, Mohammad T. Rabbani, Romain Letrun, Jorvani Cruz Villarreal, Dai Hyun Kim, Sahir Gandhi, Ana Egatz-Gomez, Mukul Sonker, Joe Chen, Faisal H. M. Koua, et al.

    Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.


  • Open Access

    Unsupervised learning approaches to characterizing heterogeneous samples using X-ray single-particle imaging

    by Yulong Zhuang, Salah Awel, Anton Barty, Richard Bean, Johan Bielecki, Martin Bergemann, Benedikt J. Daurer, Tomas Ekeberg, Armando D. Estillore, Hans Fangohr, et al.

    One of the outstanding analytical problems in X-ray single-particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and the fact that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. Proposed here are two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA), provides a rough classification which is essentially parameter free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs), can generate 3D structures of the objects at any point in the structural landscape. Both these methods are implemented in combination with the noise-tolerant expand–maximize–compress (EMC) algorithm and its utility is demonstrated by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern. Both discrete structural classes and continuous deformations are recovered. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility of moving beyond the study of homogeneous sample sets to addressing open questions on topics such as nanocrystal growth and dynamics, as well as phase transitions which have not been externally triggered.


  • Open Access

    Shock Damage Analysis in Serial Femtosecond Crystallography Data Collected at MHz X-ray Free-Electron Lasers

    by Alexander Gorel, Marie Luise Grünbein, Richard Bean, Johan Bielecki, Mario Hilpert, Michele Cascella, Jacques-Philippe Colletier, Hans Fangohr, Lutz Foucar, Elisabeth Hartmann, et al.

    Serial femtosecond crystallography (SFX) data were recorded at the European X-ray free-electron laser facility (EuXFEL) with protein microcrystals delivered via a microscopic liquid jet. An XFEL beam striking such a jet may launch supersonic shock waves up the jet, compromising the oncoming sample. To investigate this efficiently, we employed a novel XFEL pulse pattern to nominally expose the sample to between zero and four shock waves before being probed. Analyzing hit rate, indexing rate, and resolution for diffraction data recorded at MHz pulse rates, we found no evidence of damage. Notably, however, this conclusion could only be drawn after careful identification and assimilation of numerous interrelated experimental factors, which we describe in detail. Failure to do so would have led to an erroneous conclusion. Femtosecond photography of the sample-carrying jet revealed critically different jet behavior from that of all homogeneous liquid jets studied to date in this manner.


  • Open Access

    Harnessing the power of an X-ray laser for serial crystallography of membrane proteins crystallized in lipidic cubic phase

    by Ming-Yue Lee, James Geiger, Andrii Ishchenko, Gye Won Han, Anton Barty, Thomas A. White, Cornelius Gati, Alexander Batyuk, Mark S. Hunter, Andrew Aquila, et al.

    Serial femtosecond crystallography (SFX) with X-ray free-electron lasers (XFELs) has proven highly successful for structure determination of challenging membrane proteins crystallized in lipidic cubic phase; however, like most techniques, it has limitations. Here we attempt to address some of these limitations related to the use of a vacuum chamber and the need for attenuation of the XFEL beam, in order to further improve the efficiency of this method. Using an optimized SFX experimental setup in a helium atmosphere, the room-temperature structure of the adenosine A2A receptor (A2AAR) at 2.0 Å resolution is determined and compared with previous A2AAR structures determined in vacuum and/or at cryogenic temperatures. Specifically, the capability of utilizing high XFEL beam transmissions is demonstrated, in conjunction with a high dynamic range detector, to collect high-resolution SFX data while reducing crystalline material consumption and shortening the collection time required for a complete dataset. The experimental setup presented herein can be applied to future SFX applications for protein nanocrystal samples to aid in structure-based discovery efforts of therapeutic targets that are difficult to crystallize.


  • Open Access

    Crystallization of ApoA1 and ApoE4 Nanolipoprotein Particles and Initial XFEL-Based Structural Studies

    by Megan L. Shelby, Deepshika Gilbile, Thomas D. Grant, William J. Bauer, Brent Segelke, Wei He, Angela C. Evans, Natalia Crespo, Pontus Fischer, Tim Pakendorf, et al.

    Nanolipoprotein particles (NLPs), also called “nanodiscs”, are discoidal particles with a patch of lipid bilayer corralled by apolipoproteins. NLPs have long been of interest due to both their utility as membrane-model systems into which membrane proteins can be inserted and solubilized and their physiological role in lipid and cholesterol transport via high-density lipoprotein (HDL) and low-density lipoprotein (LDL) maturation, which are important for human health. Serial femtosecond crystallography (SFX) at X-ray free electron lasers (XFELs) is a powerful approach for structural biology of membrane proteins, which are traditionally difficult to crystallize as large single crystals capable of producing high-quality diffraction suitable for structure determination. To facilitate understanding of the specific role of two apolipoprotein/lipid complexes, ApoA1 and ApoE4, in lipid binding and HDL/LDL particle maturation dynamics, and to develop new SFX methods involving NLP membrane protein encapsulation, we have prepared and crystallized homogeneous populations of ApoA1 and ApoE4 NLPs. Crystallization of empty NLPs yields semi-ordered objects that appear crystalline and give highly anisotropic and diffuse X-ray diffraction, similar to fiber diffraction. Several unit cell parameters were approximately determined for both NLPs from these measurements. Thus, low-background, sample conservative methods of delivery are critical. Here we implemented a fixed target sample delivery scheme utilizing the Roadrunner fast-scanning system and ultra-thin polymer/graphene support films, providing a low-volume, low-background approach to membrane protein SFX. This study represents initial steps in obtaining structural information for ApoA1 and ApoE4 NLPs and developing this system as a supporting scaffold for future structural studies of membrane proteins crystalized in a native lipid environment.


  • Ptychography at the Linac Coherent Light Source in a parasitic geometry

    by Benjamin A. Pound, Kevin M. Mertes, Adra V. Carr, Matthew H. Seaberg, Mark S. Hunter, William C. Ward, James F. Hunter, Christine M. Sweeney, Christopher M. Sewell, Nina R. Weisse-Bernstein, et al.

    X-ray free-electron lasers (FELs) are being recognized as a powerful tool in an ever-increasing number of research fields, but are very limited as to the number of experiments that they can support. This work shows that more beamtime could be made available by using `parasitic' geometries, where a secondary experiment uses the X-ray beam that the primary experiment does not utilize. The first successful ptychography experiment, a scanning coherent diffractive imaging technique, in a parasitic geometry at an X-ray FEL is demonstrated. Utilizing the CXI hutch at the Linac Coherent Light Source (LCLS), it is shown that the obtained data are of high quality and that characterizing the beam using ptychography can be much faster than traditional imprinting methods.