David Andrew Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
David Andrew Anderson has a total of 359 co-authors. Here are the top co-authors by number of shared publications:
Fan Li
Burnet Institute, Melbourne, Victoria, Australia
13 shared publications- Minh Duc Pham
Burnet Institute, Melbourne, Australia
8 shared publications - Rebecca Guy
The Kirby Institute, University of New South Wales, Sydney, NSW, Australia
8 shared publications - Basil Donovan
Kirby Institute, University of New South Wales , Sydney, New South Wales
6 shared publications - James Ward
Poche Centre for Indigenous Health, University of Queensland, Brisbane, Australia
6 shared publications - Steven G. Badman
Kirby Institute, University of New South Wales, Sydney, New South Wales, Australia
6 shared publications
Latest Publications
- Open Access
- 17 December 2023
- Published by BMJ in BMJ Global Health
- Vol. 8 (Suppl 10) , A63.1-A63
PA-309 Comparing the accuracy of inflammation detection using the lateral flow point of care Genital InFlammation Test (GIFT) interpreted by visual inspection versus automated reader
Background Sexually transmitted infections (STIs) and bacterial vaginosis (BV) are highly prevalent risk factors for HIV infection, partly driven by genital inflammation. We have developed a novel true point-of-care inflammation lateral flow assay called the Genital InFlammation Test (GIFT). GIFT detects the presence of elevated genital inflammatory cytokines to screen for asymptomatic STIs/BV cases that are missed in settings where syndromic management is practiced. Novel point-of-care tests (like GIFT) must benchmark their performance against the guidelines specified by the WHO’s REASSURED criteria, which includes being equipment-free. This study compared the performance of human eye reading of the GIFT device to an automated device reader. Methods Bio-banked lateral vaginal wall swabs collected from 10 women were tested for the presence of inflammation biomarker bands (IL-1alpha, IL-1beta) on GIFT devices, which were visually assessed by two independent researchers for band intensity (using G-scores between 0–10). Visual inspection of G-score band intensity was benchmarked against cytokine concentrations measured by commercial ELISA. G-score visual assessments were compared with band intensity measurements using an automated device reader (AXXIN-AX-2X-S™). Results Significant concordance was observed between visual (G-scores) for IL-1alpha and IL-1beta and automated reader intensities (rho=0.96, pConclusion This laboratory evaluation of the GIFT device performance, assessed visually or using an automated reader suggests that the reader may offer a sensitivity benefit over visual reading at lower vaginal cytokine concentrations, while accuracy will be comparable at higher concentrations.
- 17 December 2023
- Published by BMJ in BMJ Global Health
- Vol. 8 (Suppl 10) , A63.1-A63
Open AccessPA-309 Comparing the accuracy of inflammation detection using the lateral flow point of care Genital InFlammation Test (GIFT) interpreted by visual inspection versus automated reader
Background Sexually transmitted infections (STIs) and bacterial vaginosis (BV) are highly prevalent risk factors for HIV infection, partly driven by genital inflammation. We have developed a novel true point-of-care inflammation lateral flow assay called the Genital InFlammation Test (GIFT). GIFT detects the presence of elevated genital inflammatory cytokines to screen for asymptomatic STIs/BV cases that are missed in settings where syndromic management is practiced. Novel point-of-care tests (like GIFT) must benchmark their performance against the guidelines specified by the WHO’s REASSURED criteria, which includes being equipment-free. This study compared the performance of human eye reading of the GIFT device to an automated device reader. Methods Bio-banked lateral vaginal wall swabs collected from 10 women were tested for the presence of inflammation biomarker bands (IL-1alpha, IL-1beta) on GIFT devices, which were visually assessed by two independent researchers for band intensity (using G-scores between 0–10). Visual inspection of G-score band intensity was benchmarked against cytokine concentrations measured by commercial ELISA. G-score visual assessments were compared with band intensity measurements using an automated device reader (AXXIN-AX-2X-S™). Results Significant concordance was observed between visual (G-scores) for IL-1alpha and IL-1beta and automated reader intensities (rho=0.96, pConclusion This laboratory evaluation of the GIFT device performance, assessed visually or using an automated reader suggests that the reader may offer a sensitivity benefit over visual reading at lower vaginal cytokine concentrations, while accuracy will be comparable at higher concentrations.
- Open Access
- 18 August 2023
- Published by Wiley in Immunology & Cell Biology
- Vol. 101 (9) , 857-866
Serological assays to measure dimeric IgA antibodies in SARS‐CoV‐2 infections
Current serological tests cannot differentiate between total immunoglobulin A (IgA) and dimeric IgA (dIgA) associated with mucosal immunity. Here, we describe two new assays, dIgA‐ELISA and dIgA‐multiplex bead assay (MBA), that utilize the preferential binding of dIgA to a chimeric form of secretory component, allowing the differentiation between dIgA and monomeric IgA. dIgA responses elicited through severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) infection were measured in (i) a longitudinal panel, consisting of 74 samples (n = 20 individuals) from hospitalized cases of coronavirus disease 2019 (COVID‐19); (ii) a longitudinal panel, consisting of 96 samples (n = 10 individuals) from individuals with mild COVID‐19; (iii) a cross‐sectional panel with PCR‐confirmed SARS‐CoV‐2 infection with mild COVID‐19 (n = 199) and (iv) pre–COVID‐19 samples (n = 200). The dIgA‐ELISA and dIgA‐MBA demonstrated a specificity for dIgA of 99% and 98.5%, respectively. Analysis of dIgA responses in the longitudinal panels revealed that 70% (ELISA) and 50% (MBA) of patients elicited a dIgA response by day 20 after PCR diagnosis with a SARS‐CoV‐2 infection. Individuals with mild COVID‐19 displayed increased levels of dIgA within the first 3 weeks after diagnosis but responses appeared to be short lived, compared with sustained IgA levels. However, in samples from hospitalized patients with COVID‐19 we observed high and sustained levels of dIgA, up to 245 days after PCR diagnosis. Our results suggest that severe COVID‐19 infections are associated with sustained levels of plasma dIgA compared with mild cases.
- 18 August 2023
- Published by Wiley in Immunology & Cell Biology
- Vol. 101 (9) , 857-866
Open AccessSerological assays to measure dimeric IgA antibodies in SARS‐CoV‐2 infections
Current serological tests cannot differentiate between total immunoglobulin A (IgA) and dimeric IgA (dIgA) associated with mucosal immunity. Here, we describe two new assays, dIgA‐ELISA and dIgA‐multiplex bead assay (MBA), that utilize the preferential binding of dIgA to a chimeric form of secretory component, allowing the differentiation between dIgA and monomeric IgA. dIgA responses elicited through severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) infection were measured in (i) a longitudinal panel, consisting of 74 samples (n = 20 individuals) from hospitalized cases of coronavirus disease 2019 (COVID‐19); (ii) a longitudinal panel, consisting of 96 samples (n = 10 individuals) from individuals with mild COVID‐19; (iii) a cross‐sectional panel with PCR‐confirmed SARS‐CoV‐2 infection with mild COVID‐19 (n = 199) and (iv) pre–COVID‐19 samples (n = 200). The dIgA‐ELISA and dIgA‐MBA demonstrated a specificity for dIgA of 99% and 98.5%, respectively. Analysis of dIgA responses in the longitudinal panels revealed that 70% (ELISA) and 50% (MBA) of patients elicited a dIgA response by day 20 after PCR diagnosis with a SARS‐CoV‐2 infection. Individuals with mild COVID‐19 displayed increased levels of dIgA within the first 3 weeks after diagnosis but responses appeared to be short lived, compared with sustained IgA levels. However, in samples from hospitalized patients with COVID‐19 we observed high and sustained levels of dIgA, up to 245 days after PCR diagnosis. Our results suggest that severe COVID‐19 infections are associated with sustained levels of plasma dIgA compared with mild cases.
- Open Access
- 30 March 2023
- Published by Wolters Kluwer Health in Hepatology Communications
- Vol. 7 (4)
A novel point-of-care test for cirrhosis based on dimeric to monomeric IgA ratio in blood: a pilot cohort study
Background and Aims: Dimeric IgA to monomeric IgA ratio (dIgA ratio) is a biomarker of gut mucosal leakage in liver cirrhosis. We evaluated the diagnostic performance of a novel point-of-care (POC) dIgA ratio test for cirrhosis. Methods: Plasma samples from people with chronic liver disease were analyzed using the BioPoint POC dIgA ratio antigen immunoassay lateral flow test. Cirrhosis was defined by Fibroscan>12.5 kPa, clinical evidence of cirrhosis or liver histopathology. POC dIgA test diagnostic accuracy was determined in a test cohort using receiver operating characteristic curve analysis; optimal cutoffs for sensitivity and specificity were then applied to a validation cohort. Results: A total of 1478 plasma samples from 866 patients with chronic liver disease were included (test cohort n = 260, validation cohort n = 606). In all, 32% had cirrhosis; 44% Child-Pugh A, 26% Child-Pugh B, and 29% Child-Pugh C. Median POC dIgA ratio was higher in cirrhosis (0.9) compared with no cirrhosis (0.4, p < 0.001), and in Child-Pugh class B/C compared with A cirrhosis (1.4 Child-Pugh B/C vs. 0.6 Child-Pugh A, p < 0.001). POC dIgA ratio test had good diagnostic accuracy for liver cirrhosis in the test cohort (area under the receiver operating characteristic curve=0.80); a dIgA ratio cutoff of 0.6 had a sensitivity of 74% and specificity of 86%. POC dIgA test accuracy was moderate in the validation cohort (area under the receiver operating characteristic curve=0.75; positive predictive value 64%, negative predictive value 83%). Using a dual cutoff approach, 79% of cirrhosis cases were correctly diagnosed and further testing was avoided in 57%. Conclusions: POC dIgA ratio test had moderate accuracy for cirrhosis. Further studies evaluating the accuracy of POC dIgA ratio testing for cirrhosis screening are warranted. Export
- 30 March 2023
- Published by Wolters Kluwer Health in Hepatology Communications
- Vol. 7 (4)
Open AccessA novel point-of-care test for cirrhosis based on dimeric to monomeric IgA ratio in blood: a pilot cohort study
Background and Aims: Dimeric IgA to monomeric IgA ratio (dIgA ratio) is a biomarker of gut mucosal leakage in liver cirrhosis. We evaluated the diagnostic performance of a novel point-of-care (POC) dIgA ratio test for cirrhosis. Methods: Plasma samples from people with chronic liver disease were analyzed using the BioPoint POC dIgA ratio antigen immunoassay lateral flow test. Cirrhosis was defined by Fibroscan>12.5 kPa, clinical evidence of cirrhosis or liver histopathology. POC dIgA test diagnostic accuracy was determined in a test cohort using receiver operating characteristic curve analysis; optimal cutoffs for sensitivity and specificity were then applied to a validation cohort. Results: A total of 1478 plasma samples from 866 patients with chronic liver disease were included (test cohort n = 260, validation cohort n = 606). In all, 32% had cirrhosis; 44% Child-Pugh A, 26% Child-Pugh B, and 29% Child-Pugh C. Median POC dIgA ratio was higher in cirrhosis (0.9) compared with no cirrhosis (0.4, p < 0.001), and in Child-Pugh class B/C compared with A cirrhosis (1.4 Child-Pugh B/C vs. 0.6 Child-Pugh A, p < 0.001). POC dIgA ratio test had good diagnostic accuracy for liver cirrhosis in the test cohort (area under the receiver operating characteristic curve=0.80); a dIgA ratio cutoff of 0.6 had a sensitivity of 74% and specificity of 86%. POC dIgA test accuracy was moderate in the validation cohort (area under the receiver operating characteristic curve=0.75; positive predictive value 64%, negative predictive value 83%). Using a dual cutoff approach, 79% of cirrhosis cases were correctly diagnosed and further testing was avoided in 57%. Conclusions: POC dIgA ratio test had moderate accuracy for cirrhosis. Further studies evaluating the accuracy of POC dIgA ratio testing for cirrhosis screening are warranted. Export
- Open Access
- 4 July 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (13) , 8172
Point-of-Care Diagnostics for Diagnosis of Active Syphilis Infection: Needs, Challenges and the Way Forward
Syphilis, a curable sexually transmitted infection, has re-emerged as a global public health threat with an estimated 5.6 million new cases every year. Pregnant women and men who have sex with men are key target populations for syphilis control and prevention programs. Frequent syphilis testing for timely and accurate diagnosis of active infections for appropriate clinical management is a key strategy to effectively prevent disease transmission. However, there are persistent challenges in the diagnostic landscape and service delivery/testing models that hinder global syphilis control efforts. In this commentary, we summarise the current trends and challenges in diagnosis of active syphilis infection and identify the data gaps and key areas for research and development of novel point-of-care diagnostics which could help to overcome the present technological, individual and structural barriers in access to syphilis testing. We present expert opinion on future research which will be required to accelerate the validation and implementation of new point-of-care diagnostics in real-world settings.
- 4 July 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (13) , 8172
Open AccessPoint-of-Care Diagnostics for Diagnosis of Active Syphilis Infection: Needs, Challenges and the Way Forward
Syphilis, a curable sexually transmitted infection, has re-emerged as a global public health threat with an estimated 5.6 million new cases every year. Pregnant women and men who have sex with men are key target populations for syphilis control and prevention programs. Frequent syphilis testing for timely and accurate diagnosis of active infections for appropriate clinical management is a key strategy to effectively prevent disease transmission. However, there are persistent challenges in the diagnostic landscape and service delivery/testing models that hinder global syphilis control efforts. In this commentary, we summarise the current trends and challenges in diagnosis of active syphilis infection and identify the data gaps and key areas for research and development of novel point-of-care diagnostics which could help to overcome the present technological, individual and structural barriers in access to syphilis testing. We present expert opinion on future research which will be required to accelerate the validation and implementation of new point-of-care diagnostics in real-world settings.
- Open Access
- 16 June 2022
- Published by Springer Nature in BMC Public Health
- Vol. 22 (1) , 1-23
Viral load monitoring for people living with HIV in the era of test and treat: progress made and challenges ahead – a systematic review
Background: In 2016, we conducted a systematic review to assess the feasibility of treatment monitoring for people living with HIV (PLHIV) receiving antiretroviral therapy (ART) in low and middle-income countries (LMICs), in line with the 90-90-90 treatment target. By 2020, global estimates suggest the 90-90-90 target, particularly the last 90, remains unattainable in many LMICs. This study aims to review the progress and identify needs for public health interventions to improve viral load monitoring and viral suppression for PLHIV in LMICs. Methods: A literature search was conducted using an update of the initial search strategy developed for the 2016 review. Electronic databases (Medline and PubMed) were searched to identify relevant literature published in English between Dec 2015 and August 2021. The primary outcome was initial viral load (VL) monitoring (the proportion of PLHIV on ART and eligible for VL monitoring who received a VL test). Secondary outcomes included follow-up VL monitoring (the proportion of PLHIV who received a follow-up VL after an initial elevated VL test), confirmation of treatment failure (the proportion of PLHIV who had two consecutive elevated VL results) and switching treatment regimen rates (the proportion of PLHIV who switched treatment regimen after confirmation of treatment failure). Results: The search strategy identified 1984 non-duplicate records, of which 34 studies were included in the review. Marked variations in initial VL monitoring coverage were reported across study settings/countries (range: 12–93% median: 74% IQR: 46–82%) and study populations (adults (range: 25–96%, median: 67% IQR: 50–84%), children, adolescents/young people (range: 2–94%, median: 72% IQR: 47–85%), and pregnant women (range: 32–82%, median: 57% IQR: 43–71%)). Community-based models reported higher VL monitoring (median: 85%, IQR: 82-88%) compared to decentralised care at primary health facility (median: 64%, IRQ: 48-82%). Suboptimal uptake of follow-up VL monitoring and low regimen switching rates were observed. Conclusions: Substantial gaps in VL coverage across study settings and study populations were evident, with limited data availability outside of sub-Saharan Africa. Further research is needed to fill the data gaps. Development and implementation of innovative, community-based interventions are required to improve VL monitoring and address the “failure cascade” in PLHIV on ART who fail to achieve viral suppression.
- 16 June 2022
- Published by Springer Nature in BMC Public Health
- Vol. 22 (1) , 1-23
Open AccessViral load monitoring for people living with HIV in the era of test and treat: progress made and challenges ahead – a systematic review
Background: In 2016, we conducted a systematic review to assess the feasibility of treatment monitoring for people living with HIV (PLHIV) receiving antiretroviral therapy (ART) in low and middle-income countries (LMICs), in line with the 90-90-90 treatment target. By 2020, global estimates suggest the 90-90-90 target, particularly the last 90, remains unattainable in many LMICs. This study aims to review the progress and identify needs for public health interventions to improve viral load monitoring and viral suppression for PLHIV in LMICs. Methods: A literature search was conducted using an update of the initial search strategy developed for the 2016 review. Electronic databases (Medline and PubMed) were searched to identify relevant literature published in English between Dec 2015 and August 2021. The primary outcome was initial viral load (VL) monitoring (the proportion of PLHIV on ART and eligible for VL monitoring who received a VL test). Secondary outcomes included follow-up VL monitoring (the proportion of PLHIV who received a follow-up VL after an initial elevated VL test), confirmation of treatment failure (the proportion of PLHIV who had two consecutive elevated VL results) and switching treatment regimen rates (the proportion of PLHIV who switched treatment regimen after confirmation of treatment failure). Results: The search strategy identified 1984 non-duplicate records, of which 34 studies were included in the review. Marked variations in initial VL monitoring coverage were reported across study settings/countries (range: 12–93% median: 74% IQR: 46–82%) and study populations (adults (range: 25–96%, median: 67% IQR: 50–84%), children, adolescents/young people (range: 2–94%, median: 72% IQR: 47–85%), and pregnant women (range: 32–82%, median: 57% IQR: 43–71%)). Community-based models reported higher VL monitoring (median: 85%, IQR: 82-88%) compared to decentralised care at primary health facility (median: 64%, IRQ: 48-82%). Suboptimal uptake of follow-up VL monitoring and low regimen switching rates were observed. Conclusions: Substantial gaps in VL coverage across study settings and study populations were evident, with limited data availability outside of sub-Saharan Africa. Further research is needed to fill the data gaps. Development and implementation of innovative, community-based interventions are required to improve VL monitoring and address the “failure cascade” in PLHIV on ART who fail to achieve viral suppression.
- Open Access
- 3 December 2021
- Published by Elsevier in EBioMedicine
- Vol. 74, 103729
A point-of-care lateral flow assay for neutralising antibodies against SARS-CoV-2
- 3 December 2021
- Published by Elsevier in EBioMedicine
- Vol. 74, 103729
Open AccessA point-of-care lateral flow assay for neutralising antibodies against SARS-CoV-2
- Open Access
Dimeric IgA is a specific biomarker of recent SARS-CoV-2 infection
Current tests for SARS-CoV-2 antibodies (IgG, IgM, IgA) cannot differentiate recent and past infections. We describe a point of care, lateral flow assay for SARS-CoV-2 dIgA based on the highly selective binding of dIgA to a chimeric form of secretory component (CSC), that distinguishes dIgA from monomeric IgA. Detection of specific dIgA uses a complex of biotinylated SARS-CoV-2 receptor binding domain and streptavidin-colloidal gold. SARS-CoV-2-specific dIgA was measured both in 112 cross-sectional samples and a longitudinal panel of 362 plasma samples from 45 patients with PCR-confirmed SARS-CoV-2 infection, and 193 discrete pre-COVID-19 or PCR-negative patient samples. The assay demonstrated 100% sensitivity from 11 days post-symptom onset, and a specificity of 98.2%. With an estimated half-life of 6.3 days, dIgA provides a unique biomarker for the detection of recent SARS-CoV-2 infections with potential to enhance diagnosis and management of COVID-19 at point-of-care.
Open AccessDimeric IgA is a specific biomarker of recent SARS-CoV-2 infection
Current tests for SARS-CoV-2 antibodies (IgG, IgM, IgA) cannot differentiate recent and past infections. We describe a point of care, lateral flow assay for SARS-CoV-2 dIgA based on the highly selective binding of dIgA to a chimeric form of secretory component (CSC), that distinguishes dIgA from monomeric IgA. Detection of specific dIgA uses a complex of biotinylated SARS-CoV-2 receptor binding domain and streptavidin-colloidal gold. SARS-CoV-2-specific dIgA was measured both in 112 cross-sectional samples and a longitudinal panel of 362 plasma samples from 45 patients with PCR-confirmed SARS-CoV-2 infection, and 193 discrete pre-COVID-19 or PCR-negative patient samples. The assay demonstrated 100% sensitivity from 11 days post-symptom onset, and a specificity of 98.2%. With an estimated half-life of 6.3 days, dIgA provides a unique biomarker for the detection of recent SARS-CoV-2 infections with potential to enhance diagnosis and management of COVID-19 at point-of-care.
- Open Access
A point-of-care lateral flow assay for neutralising antibodies against SARS-CoV-2
As vaccines against SARS-CoV-2 are now being rolled out, a better understanding of immunity to the virus; whether through infection, or passive or active immunisation, and the durability of this protection is required. This will benefit from the ability to measure SARS-CoV-2 immunity, ideally with rapid turnaround and without the need for laboratory-based testing. Current rapid point-of-care (POC) tests measure antibodies (Ab) against the SARS-CoV-2 virus, however, these tests provide no information on whether the antibodies can neutralise virus infectivity and are potentially protective, especially against newly emerging variants of the virus. Neutralising Antibodies (NAb) are emerging as a strong correlate of protection, but most current NAb assays require many hours or days, samples of venous blood, and access to laboratory facilities, which is especially problematic in resource-limited settings. We have developed a lateral flow POC test that can measure levels of RBD-ACE2 neutralising antibodies from whole blood, with a result that can be determined by eye (semi-quantitative) or on a small instrument (quantitative), and results show high correlation with microneutralisation assays. This assay also provides a measure of total anti-RBD antibody, thereby providing evidence of exposure to SARS-CoV-2 or immunisation, regardless of whether NAb are present in the sample. By testing samples from immunised macaques, we demonstrate that this test is equally applicable for use with animal samples, and we show that this assay is readily adaptable to test for immunity to newly emerging SARS-CoV-2 variants. Lastly, using a cohort of vaccinated humans, we demonstrate that our whole-blood test correlates closely with microneutralisation assay data (R 2 =0.75, p<0.0001), and that fingerprick whole blood samples are sufficient for this test. Accordingly, the COVID-19 NAb-test™ device described here can provide a rapid readout of immunity to SARS-CoV-2 at the point of care.
Open AccessA point-of-care lateral flow assay for neutralising antibodies against SARS-CoV-2
As vaccines against SARS-CoV-2 are now being rolled out, a better understanding of immunity to the virus; whether through infection, or passive or active immunisation, and the durability of this protection is required. This will benefit from the ability to measure SARS-CoV-2 immunity, ideally with rapid turnaround and without the need for laboratory-based testing. Current rapid point-of-care (POC) tests measure antibodies (Ab) against the SARS-CoV-2 virus, however, these tests provide no information on whether the antibodies can neutralise virus infectivity and are potentially protective, especially against newly emerging variants of the virus. Neutralising Antibodies (NAb) are emerging as a strong correlate of protection, but most current NAb assays require many hours or days, samples of venous blood, and access to laboratory facilities, which is especially problematic in resource-limited settings. We have developed a lateral flow POC test that can measure levels of RBD-ACE2 neutralising antibodies from whole blood, with a result that can be determined by eye (semi-quantitative) or on a small instrument (quantitative), and results show high correlation with microneutralisation assays. This assay also provides a measure of total anti-RBD antibody, thereby providing evidence of exposure to SARS-CoV-2 or immunisation, regardless of whether NAb are present in the sample. By testing samples from immunised macaques, we demonstrate that this test is equally applicable for use with animal samples, and we show that this assay is readily adaptable to test for immunity to newly emerging SARS-CoV-2 variants. Lastly, using a cohort of vaccinated humans, we demonstrate that our whole-blood test correlates closely with microneutralisation assay data (R 2 =0.75, p<0.0001), and that fingerprick whole blood samples are sufficient for this test. Accordingly, the COVID-19 NAb-test™ device described here can provide a rapid readout of immunity to SARS-CoV-2 at the point of care.
- 1 October 2019
- Published by SAGE Publications in Monoclonal Antibodies in Immunodiagnosis and Immunotherapy
- Vol. 38 (5) , 185-189
Development and Characterization of Monoclonal Antibodies Against Glycophorin A Applicable for Blood Sample Processing
The separation of plasma from blood cells is critical for the accuracy of blood tests because cellular fractions can create discrepancies in analysis. The most common method to separate blood cells from the liquid part of the blood is centrifugation, which is not always applicable in resource-constrained areas and countries. In this study, we describe the generation of monoclonal antibodies (mAbs) against glycophorin A (GPA) of human erythrocytes. BALB/c mice were immunized with human erythrocytes followed by purified GPA. The splenocytes of the immunized mice were fused with Sp2/0 myeloma cells by hybridoma technique. Hybridoma clones were screened by hemagglutination assay and enzyme-linked immunosorbent assay (ELISA). Six hybridoma clones were obtained and subcloned. The characterization of the purified mAbs demonstrates that they are able to bind and retain erythrocytes in hemagglutination assay. Furthermore, one of the mAbs 1A9 recognizes purified GPA in ELISA, whereas the other mAb 1G7 is able to immunoprecipitate GPA from human erythrocyte lysates, and a band of 38 kDa is detected. In conclusion, the anti-GPA mAbs are useful tools in developing a quick and easy way to separate blood plasma from whole blood for clinical tests, and in developing bi-specific antibodies for other clinical applications.
- 1 October 2019
- Published by SAGE Publications in Monoclonal Antibodies in Immunodiagnosis and Immunotherapy
- Vol. 38 (5) , 185-189
Development and Characterization of Monoclonal Antibodies Against Glycophorin A Applicable for Blood Sample Processing
The separation of plasma from blood cells is critical for the accuracy of blood tests because cellular fractions can create discrepancies in analysis. The most common method to separate blood cells from the liquid part of the blood is centrifugation, which is not always applicable in resource-constrained areas and countries. In this study, we describe the generation of monoclonal antibodies (mAbs) against glycophorin A (GPA) of human erythrocytes. BALB/c mice were immunized with human erythrocytes followed by purified GPA. The splenocytes of the immunized mice were fused with Sp2/0 myeloma cells by hybridoma technique. Hybridoma clones were screened by hemagglutination assay and enzyme-linked immunosorbent assay (ELISA). Six hybridoma clones were obtained and subcloned. The characterization of the purified mAbs demonstrates that they are able to bind and retain erythrocytes in hemagglutination assay. Furthermore, one of the mAbs 1A9 recognizes purified GPA in ELISA, whereas the other mAb 1G7 is able to immunoprecipitate GPA from human erythrocyte lysates, and a band of 38 kDa is detected. In conclusion, the anti-GPA mAbs are useful tools in developing a quick and easy way to separate blood plasma from whole blood for clinical tests, and in developing bi-specific antibodies for other clinical applications.
- Open Access
- 10 September 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (9) , e0221733
Malaria vaccine candidates displayed on novel virus-like particles are immunogenic and induce transmission-blocking activity
The development of effective malaria vaccines remains a global health priority. Currently, the most advanced vaccine, known as RTS,S, has only shown modest efficacy in clinical trials. Thus, the development of more efficacious vaccines by improving the formulation of RTS,S for increased efficacy or to interrupt malaria transmission are urgently needed. The RTS,S vaccine is based on the presentation of a fragment of the sporozoite antigen on the surface of virus-like particles (VLPs) based on human hepatitis B virus (HBV). In this study, we have developed and evaluated a novel VLP platform based on duck HBV (known as Metavax) for malaria vaccine development. This platform can incorporate large and complex proteins into VLPs and is produced in a Hansenula cell line compatible with cGMP vaccine production. Here, we have established the expression of leading P. falciparum malaria vaccine candidates as VLPs. This includes Pfs230 and Pfs25, which are candidate transmission-blocking vaccine antigens. We demonstrated that the VLPs effectively induce antibodies to malaria vaccine candidates with minimal induction of antibodies to the duck-HBV scaffold antigen. Antibodies to Pfs230 also recognised native protein on the surface of gametocytes, and antibodies to both Pfs230 and Pfs25 demonstrated transmission-reducing activity in standard membrane feeding assays. These results establish the potential utility of this VLP platform for malaria vaccines, which may be suitable for the development of multi-component vaccines that achieve high vaccine efficacy and transmission-blocking immunity.
- 10 September 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (9) , e0221733
Open AccessMalaria vaccine candidates displayed on novel virus-like particles are immunogenic and induce transmission-blocking activity
The development of effective malaria vaccines remains a global health priority. Currently, the most advanced vaccine, known as RTS,S, has only shown modest efficacy in clinical trials. Thus, the development of more efficacious vaccines by improving the formulation of RTS,S for increased efficacy or to interrupt malaria transmission are urgently needed. The RTS,S vaccine is based on the presentation of a fragment of the sporozoite antigen on the surface of virus-like particles (VLPs) based on human hepatitis B virus (HBV). In this study, we have developed and evaluated a novel VLP platform based on duck HBV (known as Metavax) for malaria vaccine development. This platform can incorporate large and complex proteins into VLPs and is produced in a Hansenula cell line compatible with cGMP vaccine production. Here, we have established the expression of leading P. falciparum malaria vaccine candidates as VLPs. This includes Pfs230 and Pfs25, which are candidate transmission-blocking vaccine antigens. We demonstrated that the VLPs effectively induce antibodies to malaria vaccine candidates with minimal induction of antibodies to the duck-HBV scaffold antigen. Antibodies to Pfs230 also recognised native protein on the surface of gametocytes, and antibodies to both Pfs230 and Pfs25 demonstrated transmission-reducing activity in standard membrane feeding assays. These results establish the potential utility of this VLP platform for malaria vaccines, which may be suitable for the development of multi-component vaccines that achieve high vaccine efficacy and transmission-blocking immunity.