Nour Aldeen Jalal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nour Aldeen Jalal has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Knut Möller
Institute of Technical Medicine, Furtwangen University, 78054 Villingen-Schwenningen, Germany
3 shared publications - Lars Mündermann
Karl-Storz GmbH , Germany
2 shared publications - Tamer Abdulbaki Alshirbaji
Furtwangen University , Institute of Technical Medicine , Germany
2 shared publications - Alberto Battistel
Institute of Technical Medicine (ITeM), Furtwangen University, 78054 Villingen-Schwenningen, Germany
1 shared publication - Herag Arabian
Institute of Technical Medicine (ITeM), Furtwangen University, 78054 Villingen-Schwenningen, Germany
1 shared publication - Hisham ElMoaqet
Department of Mechatronics Engineering, German Jordanian University, Amman 11180, Jordan
1 shared publication
Latest Publications
- Open Access
Cholec80-Boxes: Bounding Box Labelling Data for Surgical Tools in Cholecystectomy Images
Surgical data analysis is crucial for developing and integrating context-aware systems (CAS) in advanced operating rooms. Automatic detection of surgical tools is an essential component in CAS, as it enables the recognition of surgical activities and understanding the contextual status of the procedure. Acquiring surgical data is challenging due to ethical constraints and the complexity of establishing data recording infrastructures. For machine learning tasks, there is also the large burden of data labelling. Although a relatively large dataset, namely the Cholec80, is publicly available, it is limited to the binary label data corresponding to the surgical tool presence. In this work, 15,691 frames from five videos from the dataset have been labelled with bounding boxes for surgical tool localisation. These newly labelled data support future research in developing and evaluating object detection models, particularly in the laparoscopic image data analysis domain.
Open AccessCholec80-Boxes: Bounding Box Labelling Data for Surgical Tools in Cholecystectomy Images
Surgical data analysis is crucial for developing and integrating context-aware systems (CAS) in advanced operating rooms. Automatic detection of surgical tools is an essential component in CAS, as it enables the recognition of surgical activities and understanding the contextual status of the procedure. Acquiring surgical data is challenging due to ethical constraints and the complexity of establishing data recording infrastructures. For machine learning tasks, there is also the large burden of data labelling. Although a relatively large dataset, namely the Cholec80, is publicly available, it is limited to the binary label data corresponding to the surgical tool presence. In this work, 15,691 frames from five videos from the dataset have been labelled with bounding boxes for surgical tool localisation. These newly labelled data support future research in developing and evaluating object detection models, particularly in the laparoscopic image data analysis domain.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 191-194
Classifying smoke in laparoscopic videos using SVM
Smoke in laparoscopic videos usually appears due to the use of electrocautery when cutting or coagulating tissues. Therefore, detecting smoke can be used for event-based annotation in laparoscopic surgeries by retrieving the events associated with the electrocauterization. Furthermore, smoke detection can also be used for automatic smoke removal. However, detecting smoke in laparoscopic video is a challenge because of the changeability of smoke patterns, the moving camera and the different lighting conditions. In this paper, we present a video-based smoke detection algorithm to detect smoke of different densities such as fog, low and high density in laparoscopic videos. The proposed method depends on extracting various visual features from the laparoscopic images and providing them to support vector machine (SVM) classifier. Features are based on motion, colour and texture patterns of the smoke. We validated our algorithm using experimental evaluation on four laparoscopic cholecystectomy videos. These four videos were manually annotated by defining every frame as smoke or non-smoke frame. The algorithm was applied to the videos by using different feature combinations for classification. Experimental results show that the combination of all proposed features gives the best classification performance. The overall accuracy (i.e. correctly classified frames) is around 84%, with the sensitivity (i.e. correctly detected smoke frames) and the specificity (i.e. correctly detected non-smoke frames) are 89% and 80%, respectively.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 191-194
Open AccessClassifying smoke in laparoscopic videos using SVM
Smoke in laparoscopic videos usually appears due to the use of electrocautery when cutting or coagulating tissues. Therefore, detecting smoke can be used for event-based annotation in laparoscopic surgeries by retrieving the events associated with the electrocauterization. Furthermore, smoke detection can also be used for automatic smoke removal. However, detecting smoke in laparoscopic video is a challenge because of the changeability of smoke patterns, the moving camera and the different lighting conditions. In this paper, we present a video-based smoke detection algorithm to detect smoke of different densities such as fog, low and high density in laparoscopic videos. The proposed method depends on extracting various visual features from the laparoscopic images and providing them to support vector machine (SVM) classifier. Features are based on motion, colour and texture patterns of the smoke. We validated our algorithm using experimental evaluation on four laparoscopic cholecystectomy videos. These four videos were manually annotated by defining every frame as smoke or non-smoke frame. The algorithm was applied to the videos by using different feature combinations for classification. Experimental results show that the combination of all proposed features gives the best classification performance. The overall accuracy (i.e. correctly classified frames) is around 84%, with the sensitivity (i.e. correctly detected smoke frames) and the specificity (i.e. correctly detected non-smoke frames) are 89% and 80%, respectively.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 521-524
Features for detecting smoke in laparoscopic videos
Video-based smoke detection in laparoscopic surgery has different potential applications, such as the automatic addressing of surgical events associated with the electrocauterization task and the development of automatic smoke removal. In the literature, video-based smoke detection has been studied widely for fire surveillance systems. Nevertheless, the proposed methods are insufficient for smoke detection in laparoscopic videos because they often depend on assumptions which rarely hold in laparoscopic surgery such as static camera. In this paper, ten visual features based on motion, texture and colour of smoke are proposed and evaluated for smoke detection in laparoscopic videos. These features are RGB channels, energy-based feature, texture features based on gray level co-occurrence matrix (GLCM), HSV colour space feature, features based on the detection of moving regions using optical flow and the smoke colour in HSV colour space. These features were tested on four laparoscopic cholecystectomy videos. Experimental observations show that each feature can provide valuable information in performing the smoke detection task. However, each feature has weaknesses to detect the presence of smoke in some cases. By combining all proposed features smoke with high and even low density can be identified robustly and the classification accuracy increases significantly.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 521-524
Open AccessFeatures for detecting smoke in laparoscopic videos
Video-based smoke detection in laparoscopic surgery has different potential applications, such as the automatic addressing of surgical events associated with the electrocauterization task and the development of automatic smoke removal. In the literature, video-based smoke detection has been studied widely for fire surveillance systems. Nevertheless, the proposed methods are insufficient for smoke detection in laparoscopic videos because they often depend on assumptions which rarely hold in laparoscopic surgery such as static camera. In this paper, ten visual features based on motion, texture and colour of smoke are proposed and evaluated for smoke detection in laparoscopic videos. These features are RGB channels, energy-based feature, texture features based on gray level co-occurrence matrix (GLCM), HSV colour space feature, features based on the detection of moving regions using optical flow and the smoke colour in HSV colour space. These features were tested on four laparoscopic cholecystectomy videos. Experimental observations show that each feature can provide valuable information in performing the smoke detection task. However, each feature has weaknesses to detect the presence of smoke in some cases. By combining all proposed features smoke with high and even low density can be identified robustly and the classification accuracy increases significantly.