Michael Stiehm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael Stiehm has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Klaus-Peter Schmitz
Institute of ImplantTechnology and Biomaterials e.V., Rostock-Warnemünde, Germany
5 shared publicationsNiels Grabow
Institute for Biomedical Engineering, Rostock University Medical Center, Rostock- Warnemünde , Germany
4 shared publicationsStefan Siewert
Institute for Implant Technology and Biomaterials e.V., Rostock- Warnemünde , Germany
4 shared publications- Klaus-Peter Schmitz
Institute for ImplantTechnology and Biomaterials e.V. and Institute for Biomedical Engineering, Rostock University Medical Center, Rostock-Warnemuende , Germany
3 shared publications - Niels Grabow
Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, Germany
3 shared publications Carolin Wüstenhagen
Institute for ImplantatTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, Germany
2 shared publications
Latest Publications
- Open Access
- 28 July 2023
- Published by Elsevier in Clinical Biomechanics
- Vol. 108, 106056
Development of a testing device for external wrist bridging dynamic fixators used for distal radius fractures
- 28 July 2023
- Published by Elsevier in Clinical Biomechanics
- Vol. 108, 106056
Open AccessDevelopment of a testing device for external wrist bridging dynamic fixators used for distal radius fractures
- Open Access
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 123-126
Computational flow analysis of the washout of an aortic valve by means of Eulerian transport equation
Although the development of the transcatheter aortic valve (TAV) has saved many lives of inoperable patients and has a very good clinical outcome, concerns about valve thrombosis are increasing. Due to the potential risk of late clinically relevant events, the US Food and Drug Administration (FDA) suggests a careful systematic investigation of thrombosis and reduced leaflet motion related to hemodynamic changes induced by TAV implantation. Furthermore, recently published position papers of the ISO working group address numerical and experimental flow field assessment of TAV. In particular, pathologically high shear rates and a reduced washout of the sinuses may increase the risk of valve thrombosis and should therefore be investigated. By means of fluid-structure interaction (FSI) as a powerful in silico tool, the transient flow field in an aortic valve was analyzed. A linear elastic behavior was assumed for leaflet material properties (Young modulus: 10 MPa, Poisson ratio: 0.46 and leaflet material density: 1000 kg/m3) and blood was specified as a homogeneous, Newtonian and incompressible fluid (fluid density: 1060 kg/m3 and a dynamic viscosity: 0.0035 Pa s). In this numerical study we present a Eulerian approach, which is based on transport equation of the residence time (RT) as a passively transported scalar. It can be clearly seen that the RT is significantly higher in the sinus referred to the main flow. At time step t = 0.25 s, the average residence time in the main flow is RTavg ≈ 0.05 s, whereas RT ≈ 0.25 s in the sinus. In particular, RT is a valuable hemodynamic metric to quantify the washout of the sinus in order to evaluate the thrombogenic potential of TAV devices. Further studies will concentrate on particle image velocimetry measurements for validation purposes. In particular the velocity in the sinus and therefore the washout is one important hemodynamic key feature that has to be improved for future TAV designs.
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 123-126
Open AccessComputational flow analysis of the washout of an aortic valve by means of Eulerian transport equation
Although the development of the transcatheter aortic valve (TAV) has saved many lives of inoperable patients and has a very good clinical outcome, concerns about valve thrombosis are increasing. Due to the potential risk of late clinically relevant events, the US Food and Drug Administration (FDA) suggests a careful systematic investigation of thrombosis and reduced leaflet motion related to hemodynamic changes induced by TAV implantation. Furthermore, recently published position papers of the ISO working group address numerical and experimental flow field assessment of TAV. In particular, pathologically high shear rates and a reduced washout of the sinuses may increase the risk of valve thrombosis and should therefore be investigated. By means of fluid-structure interaction (FSI) as a powerful in silico tool, the transient flow field in an aortic valve was analyzed. A linear elastic behavior was assumed for leaflet material properties (Young modulus: 10 MPa, Poisson ratio: 0.46 and leaflet material density: 1000 kg/m3) and blood was specified as a homogeneous, Newtonian and incompressible fluid (fluid density: 1060 kg/m3 and a dynamic viscosity: 0.0035 Pa s). In this numerical study we present a Eulerian approach, which is based on transport equation of the residence time (RT) as a passively transported scalar. It can be clearly seen that the RT is significantly higher in the sinus referred to the main flow. At time step t = 0.25 s, the average residence time in the main flow is RTavg ≈ 0.05 s, whereas RT ≈ 0.25 s in the sinus. In particular, RT is a valuable hemodynamic metric to quantify the washout of the sinus in order to evaluate the thrombogenic potential of TAV devices. Further studies will concentrate on particle image velocimetry measurements for validation purposes. In particular the velocity in the sinus and therefore the washout is one important hemodynamic key feature that has to be improved for future TAV designs.
- Open Access
- 1 September 2018
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 4 (1) , 149-151
Hemodynamic influence of design parameters of novel venous valve prostheses
Venous ulcers of the lower limbs are one clinical manifestation of chronic venous insufficiency. Currently, there is no venous valve prosthesis available. This study presents novel venous valve prostheses made of threedimensional electrospun fibrous nonwoven leaflets. The aim of this study was to prove the feasibility of the manufacturing process as well as to investigate design features of the venous valve prostheses from a hemodynamic point of view. An adapted pulse duplicator system (ViVitrolabs, Victoria, BC, CA) was used for characterization of the hydrodynamic performance. For eight different venous valve prototypes flow rate, effective orifice area and regurgitation fraction was investigated in vitro. In particular, tricusp valve designs showed an up to 40% higher effective orifice area as well as 15% higher maximum flowrate compared to bicusp valve designs. However, the regurgitation fraction of the bicusp valve designs is up to 86% lower compared to tricusp valve. Additionally, the hemodynamic performance of the tricuspid valves showed a high sensitivity regarding the leaflet length. Bicuspid valves are less sensitive to changes of design parameters, more sufficient and therefore highly reliable.
- 1 September 2018
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 4 (1) , 149-151
Open AccessHemodynamic influence of design parameters of novel venous valve prostheses
Venous ulcers of the lower limbs are one clinical manifestation of chronic venous insufficiency. Currently, there is no venous valve prosthesis available. This study presents novel venous valve prostheses made of threedimensional electrospun fibrous nonwoven leaflets. The aim of this study was to prove the feasibility of the manufacturing process as well as to investigate design features of the venous valve prostheses from a hemodynamic point of view. An adapted pulse duplicator system (ViVitrolabs, Victoria, BC, CA) was used for characterization of the hydrodynamic performance. For eight different venous valve prototypes flow rate, effective orifice area and regurgitation fraction was investigated in vitro. In particular, tricusp valve designs showed an up to 40% higher effective orifice area as well as 15% higher maximum flowrate compared to bicusp valve designs. However, the regurgitation fraction of the bicusp valve designs is up to 86% lower compared to tricusp valve. Additionally, the hemodynamic performance of the tricuspid valves showed a high sensitivity regarding the leaflet length. Bicuspid valves are less sensitive to changes of design parameters, more sufficient and therefore highly reliable.
- 22 June 2018
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 64 (3) , 251-262
Impact of strut dimensions and vessel caliber on thrombosis risk of bioresorbable scaffolds using hemodynamic metrics
Bioresorbable scaffolds (BRS) promise to be the treatment of choice for stenosed coronary vessels. But higher thrombosis risk found in current clinical studies limits the expectations. Three hemodynamic metrics are introduced to evaluate the thrombosis risk of coronary stents/scaffolds using transient computational fluid dynamics (CFD). The principal phenomena are platelet activation and effective diffusion (platelet shear number, PSN), convective platelet transport (platelet convection number, PCN) and platelet aggregation (platelet aggregation number, PAN) were taken into consideration. In the present study, two different stent designs (thick-strut vs. thin-strut design) positioned in small- and medium-sized vessels (reference vessel diameter, RVD=2.25 mm vs. 2.70 mm) were analyzed. In both vessel models, the thick-strut design induced higher PSN, PCN and PAN values than the thin-strut design (thick-strut vs. thin-strut: PSN=2.92/2.19 and 0.54/0.30; PCN=3.14/1.15 and 2.08/0.43; PAN: 14.76/8.19 and 20.03/10.18 for RVD=2.25 mm and 2.70 mm). PSN and PCN are increased by the reduction of the vessel size (PSN: RVD=2.25 mm vs. 2.70 mm=5.41 and 7.30; PCN: RVD=2.25 mm vs. 2.70 mm=1.51 and 2.67 for thick-strut and thin-strut designs). The results suggest that bulky stents implanted in small caliber vessels may substantially increase the thrombosis risk. Moreover, sensitivity analyses imply that PSN is mostly influenced by vessel size (lesion-related factor), whereas PCN and PAN sensitively respond to strut-thickness (device-related factor).
- 22 June 2018
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 64 (3) , 251-262
Impact of strut dimensions and vessel caliber on thrombosis risk of bioresorbable scaffolds using hemodynamic metrics
Bioresorbable scaffolds (BRS) promise to be the treatment of choice for stenosed coronary vessels. But higher thrombosis risk found in current clinical studies limits the expectations. Three hemodynamic metrics are introduced to evaluate the thrombosis risk of coronary stents/scaffolds using transient computational fluid dynamics (CFD). The principal phenomena are platelet activation and effective diffusion (platelet shear number, PSN), convective platelet transport (platelet convection number, PCN) and platelet aggregation (platelet aggregation number, PAN) were taken into consideration. In the present study, two different stent designs (thick-strut vs. thin-strut design) positioned in small- and medium-sized vessels (reference vessel diameter, RVD=2.25 mm vs. 2.70 mm) were analyzed. In both vessel models, the thick-strut design induced higher PSN, PCN and PAN values than the thin-strut design (thick-strut vs. thin-strut: PSN=2.92/2.19 and 0.54/0.30; PCN=3.14/1.15 and 2.08/0.43; PAN: 14.76/8.19 and 20.03/10.18 for RVD=2.25 mm and 2.70 mm). PSN and PCN are increased by the reduction of the vessel size (PSN: RVD=2.25 mm vs. 2.70 mm=5.41 and 7.30; PCN: RVD=2.25 mm vs. 2.70 mm=1.51 and 2.67 for thick-strut and thin-strut designs). The results suggest that bulky stents implanted in small caliber vessels may substantially increase the thrombosis risk. Moreover, sensitivity analyses imply that PSN is mostly influenced by vessel size (lesion-related factor), whereas PCN and PAN sensitively respond to strut-thickness (device-related factor).
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 603-606
Inflow mapping method for numerical flow simulations of OCT-based patient-specific vessels using CFD
Alteration of the flow characteristics in coronary vessels is correlated with coronary heart disease (CHD). In particular, wall shear stress (WSS) appears to be a hemody-namic key factor in the genesis of CHD. Since computational fluid dynamics (CFD) is a well-known method for the inves-tigation of WSS, it may be a valuable tool for the prediction of CHD. Latest imaging techniques, such as optical coher-ence tomography (OCT) in conjunction with angiography deliver precise 2D data sets of patient-specific vessel geome-try, which can be used for CFD analysis. Current CFD stud-ies utilize patient-specific geometries, but are lacking well defined physiologic inflow conditions.In this study, we present an inflow mapping method for patient-specific arterial vessels, which is capable of consider-ing the influence of bifurcations located proximal of the OCT-data set. At first, the patient-specific vessel was recon-structed. For this purpose the OCT-based vessel cross sec-tions were arranged along an angiographic based vessel pathway. Secondly, we simulated the flow field in a generic bifurcation model by means of CFD. Thereafter the flow field of a side branch was extracted and transferred (mapped) to the inlet of the patient-specific vessel.To evaluate the influence of the physiological inlet the WSS distribution of the same patient-specific vessel was calculated using an axial-symmetric inflow condition. Analy-sis of the simulation data yielded deviations of the WSS distribution in the proximal vessel segment. A bifurcation, located upstream of the relevant vessel segment strongly affects the flow in the OCT-based vessel reconstruction and has a strong influence on the results of the numerical analy-sis. Therefore, it is important to implement not only the pa-tient-specific geometry, but also an inlet boundary condition adapted to the upstream velocity distribution reflecting the actual proximal flow situation of the vessel.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 603-606
Open AccessInflow mapping method for numerical flow simulations of OCT-based patient-specific vessels using CFD
Alteration of the flow characteristics in coronary vessels is correlated with coronary heart disease (CHD). In particular, wall shear stress (WSS) appears to be a hemody-namic key factor in the genesis of CHD. Since computational fluid dynamics (CFD) is a well-known method for the inves-tigation of WSS, it may be a valuable tool for the prediction of CHD. Latest imaging techniques, such as optical coher-ence tomography (OCT) in conjunction with angiography deliver precise 2D data sets of patient-specific vessel geome-try, which can be used for CFD analysis. Current CFD stud-ies utilize patient-specific geometries, but are lacking well defined physiologic inflow conditions.In this study, we present an inflow mapping method for patient-specific arterial vessels, which is capable of consider-ing the influence of bifurcations located proximal of the OCT-data set. At first, the patient-specific vessel was recon-structed. For this purpose the OCT-based vessel cross sec-tions were arranged along an angiographic based vessel pathway. Secondly, we simulated the flow field in a generic bifurcation model by means of CFD. Thereafter the flow field of a side branch was extracted and transferred (mapped) to the inlet of the patient-specific vessel.To evaluate the influence of the physiological inlet the WSS distribution of the same patient-specific vessel was calculated using an axial-symmetric inflow condition. Analy-sis of the simulation data yielded deviations of the WSS distribution in the proximal vessel segment. A bifurcation, located upstream of the relevant vessel segment strongly affects the flow in the OCT-based vessel reconstruction and has a strong influence on the results of the numerical analy-sis. Therefore, it is important to implement not only the pa-tient-specific geometry, but also an inlet boundary condition adapted to the upstream velocity distribution reflecting the actual proximal flow situation of the vessel.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 631-634
Assessment of heart valve performance by finite-element design studies of polymeric leaflet-structures
For the treatment of severe symptomatic aortic valve stenosis, minimally invasive heart valve prostheses are increasingly used, especially for elderly patients. The current generation of devices is based on xenogenic leaflet material, involving limitations with regard to calcification and durability. Artificial polymeric leaflet-structures re-present a promising approach for improvement of valve performance. Within the current work, finite-element ana-lysis (FEA) design studies of polymeric leaflet structures were conducted. Design of an unpressurized and axially-symmetric trileaflet heart valve was developed based on nine parameters. Physiological pressurization in FEA was specified, based on in vitro hydrodynamic testing of a commercially available heart valve prosthesis. Hyper-elastic constitutive law for polymeric leaflet material was implemented based on experimental stress strain curves resulting from uniaxial tensile and planar shear testing. As a result of FEA, time dependent leaflet deformation of the leaflet structure was calculated. Obtained leaflet dynamics were comparable to in vitro performance of the analyzed prosthesis. As a major design parameter, the lunula angle has demonstrated crucial influence on the performance of the polymeric leaflet structures. FEA represented a useful tool for design of improved polymeric leaflet structures for minimally invasive implantable heart valve prostheses.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 631-634
Open AccessAssessment of heart valve performance by finite-element design studies of polymeric leaflet-structures
For the treatment of severe symptomatic aortic valve stenosis, minimally invasive heart valve prostheses are increasingly used, especially for elderly patients. The current generation of devices is based on xenogenic leaflet material, involving limitations with regard to calcification and durability. Artificial polymeric leaflet-structures re-present a promising approach for improvement of valve performance. Within the current work, finite-element ana-lysis (FEA) design studies of polymeric leaflet structures were conducted. Design of an unpressurized and axially-symmetric trileaflet heart valve was developed based on nine parameters. Physiological pressurization in FEA was specified, based on in vitro hydrodynamic testing of a commercially available heart valve prosthesis. Hyper-elastic constitutive law for polymeric leaflet material was implemented based on experimental stress strain curves resulting from uniaxial tensile and planar shear testing. As a result of FEA, time dependent leaflet deformation of the leaflet structure was calculated. Obtained leaflet dynamics were comparable to in vitro performance of the analyzed prosthesis. As a major design parameter, the lunula angle has demonstrated crucial influence on the performance of the polymeric leaflet structures. FEA represented a useful tool for design of improved polymeric leaflet structures for minimally invasive implantable heart valve prostheses.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 775-778
Numerical simulation of pulsatile flow through a coronary nozzle model based on FDA’s benchmark geometry
Computational fluid dynamics (CFD) is a powerful tool to extent knowledge of biomechanical processes in cardiovascular implants. To provide a standardized method the U.S. Food and Drug Administration (FDA) initialized a CFD round robin study. One of the developed benchmark standard models is a generic nozzle geometry, consisting of a cylindrical throat with a conical collector and sudden expansion on either side. Several fluid mechanical data obtained from international institutes by means of CFD and particle image velocimetry (PIV) measurements under different flow regimes (Re = 500, 2000, 3500, 5000 and 6500) are freely available. This database includes only steady state simulations. In this study we performed pulsatile CFD simulations to consider the physiological environment of the coronary vessels. Furthermore, the nozzle geometry was scaled down to coronary dimension (D inlet = 12 mm to 3 mm) while retaining the average Reynolds number Re = 500 constant. The pulsatile character is described by a Womersley number of Wo = 2.065. Our CFD code was previously validated by using FDA’s data for steady state inflow conditions. It could be shown that time averaged wall shear stress and shear stress values agree well with steady state results. We conclude that steady state simulations are valid for hemodynamic analyses if only time averaged values are needed. This could save computational costs of future hemodynamic investigations. In addition, this study expands FDA’s benchmark case by pulsatile inlet condition for further code validation. This could be necessary for the development of new numerical methods as well as for validation of CFD codes used in the approval process of medical devices.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 775-778
Open AccessNumerical simulation of pulsatile flow through a coronary nozzle model based on FDA’s benchmark geometry
Computational fluid dynamics (CFD) is a powerful tool to extent knowledge of biomechanical processes in cardiovascular implants. To provide a standardized method the U.S. Food and Drug Administration (FDA) initialized a CFD round robin study. One of the developed benchmark standard models is a generic nozzle geometry, consisting of a cylindrical throat with a conical collector and sudden expansion on either side. Several fluid mechanical data obtained from international institutes by means of CFD and particle image velocimetry (PIV) measurements under different flow regimes (Re = 500, 2000, 3500, 5000 and 6500) are freely available. This database includes only steady state simulations. In this study we performed pulsatile CFD simulations to consider the physiological environment of the coronary vessels. Furthermore, the nozzle geometry was scaled down to coronary dimension (D inlet = 12 mm to 3 mm) while retaining the average Reynolds number Re = 500 constant. The pulsatile character is described by a Womersley number of Wo = 2.065. Our CFD code was previously validated by using FDA’s data for steady state inflow conditions. It could be shown that time averaged wall shear stress and shear stress values agree well with steady state results. We conclude that steady state simulations are valid for hemodynamic analyses if only time averaged values are needed. This could save computational costs of future hemodynamic investigations. In addition, this study expands FDA’s benchmark case by pulsatile inlet condition for further code validation. This could be necessary for the development of new numerical methods as well as for validation of CFD codes used in the approval process of medical devices.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 297-300
Transient Euler-Lagrange/DEM simulation of stent thrombosis
Stent implantation is the treatment of choice for cardiovascular diseases. By introduction of biodegradable thick strut stents investigations of thrombosis formation is one focus of research. This study deals with a transient Euler-Lagrange/DEM approach to simulate the flow field, platelet movement and clotting. The recirculation zones prolong particle residence time. As a result, the vicinity of stent struts shown a particularly higher risk for stent thrombosis.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 297-300
Open AccessTransient Euler-Lagrange/DEM simulation of stent thrombosis
Stent implantation is the treatment of choice for cardiovascular diseases. By introduction of biodegradable thick strut stents investigations of thrombosis formation is one focus of research. This study deals with a transient Euler-Lagrange/DEM approach to simulate the flow field, platelet movement and clotting. The recirculation zones prolong particle residence time. As a result, the vicinity of stent struts shown a particularly higher risk for stent thrombosis.