Qingwei Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qingwei Li has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Peng Jiang
State Key Laboratory of Radio Astronomy and Technology, National Astronomical Observatories, Chinese Academy of Sciences, Beijing, China
2 shared publications - Rui Yao
National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China
2 shared publications - Bin Luo
Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of Education, Southeast University, Nanjing 211189, China
1 shared publication - Caihong Sun
National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China
1 shared publication - De-Xiu Mo
Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian 116023, China
1 shared publication - Hong-Nan Li
School of Infrastructure Engineering, Dalian University of Technology, Dalian 116024, P. R. China
1 shared publication
Latest Publications
- Open Access
- 24 June 2025
- Published by MDPI AG in Electronics
- Vol. 14 (13) , 2544
Broken Wire Detection Based on TDFWNet and Its Application in the FAST Project
This research proposes a wire-breakage detection method based on a Time-Domain Feature Weighted Network (TDFWNet) to address the challenging issue of wire-breakage detection in the feed source cabin drive cables of the Five-hundred-meter Aperture Spherical radio Telescope (FAST). The study begins with a temporal domain morphology analysis, revealing significant differences between wire-breakage signals and interference signals in key characteristic parameters such as waveform factor, pulse factor, and kurtosis. These parameters are thus employed as the basis for feature input, and their corresponding feature probabilities are calculated to provide prior feature weights for the model. The TDFWNet model integrates the feature learning capability of a Convolutional Neural Network (CNN) with temporal domain feature analysis using the feature probabilities derived from key temporal domain characteristic parameters as weight inputs to enhance the sensitivity and recognition accuracy of wire-breakage signals. Furthermore, the research team has developed a data augmentation method based on Feature-Constrained Dynamic Time Warping (FCDTW). This method processes the original wire-breakage signals to generate high-quality augmented data, thereby improving the model’s ability to recognize wire-breakage signals. Ultimately, the TDFWNet outperforms traditional CNN models by 1.5%, 2.0%, 1.8%, and 16.6% in precision, recall, F1 score, and accuracy, respectively. In practical engineering applications, this method demonstrated excellent stability and practicality in three domestic FAST drive cable-bending fatigue tests. The detected suspected wire-breakage signals were highly consistent with the results of post-fatigue test disassembly inspections, effectively supporting the wire-breakage detection requirements in actual engineering scenarios.
- 24 June 2025
- Published by MDPI AG in Electronics
- Vol. 14 (13) , 2544
Open AccessBroken Wire Detection Based on TDFWNet and Its Application in the FAST Project
This research proposes a wire-breakage detection method based on a Time-Domain Feature Weighted Network (TDFWNet) to address the challenging issue of wire-breakage detection in the feed source cabin drive cables of the Five-hundred-meter Aperture Spherical radio Telescope (FAST). The study begins with a temporal domain morphology analysis, revealing significant differences between wire-breakage signals and interference signals in key characteristic parameters such as waveform factor, pulse factor, and kurtosis. These parameters are thus employed as the basis for feature input, and their corresponding feature probabilities are calculated to provide prior feature weights for the model. The TDFWNet model integrates the feature learning capability of a Convolutional Neural Network (CNN) with temporal domain feature analysis using the feature probabilities derived from key temporal domain characteristic parameters as weight inputs to enhance the sensitivity and recognition accuracy of wire-breakage signals. Furthermore, the research team has developed a data augmentation method based on Feature-Constrained Dynamic Time Warping (FCDTW). This method processes the original wire-breakage signals to generate high-quality augmented data, thereby improving the model’s ability to recognize wire-breakage signals. Ultimately, the TDFWNet outperforms traditional CNN models by 1.5%, 2.0%, 1.8%, and 16.6% in precision, recall, F1 score, and accuracy, respectively. In practical engineering applications, this method demonstrated excellent stability and practicality in three domestic FAST drive cable-bending fatigue tests. The detected suspected wire-breakage signals were highly consistent with the results of post-fatigue test disassembly inspections, effectively supporting the wire-breakage detection requirements in actual engineering scenarios.
- Open Access
Modal Frequency and Damping Identification of the FAST Cabin-Cable System
The Five-Hundred-Meter Aperture Spherical Radio Telescope (FAST) faces challenges in establishing high-precision rigid connections between the receiver and the reflective surface due to its vast spatial span. Innovatively, FAST suspends the feed cabin in mid-air using six supporting cables. The precise positioning of the feed focal point is achieved through the coordinated control of cable extension and retraction, along with the A-B axis and the Stewart platform within the cabin. The cables and the feed cabin form a large parallel mechanism. Since the cables are flexible, and the feed cabin remains at a high altitude during observations, it is inevitably subject to internal and external disturbances. To quickly dissipate these disturbances, the system requires a certain level of damping, which directly affects the pointing and tracking accuracy of FAST. During the 2022–2023 operational period, there were multiple instances where the pulleys of the curtain mechanism on the supporting cables became stuck and were carried to the top of the towers by the cables. This also led to the phenomenon where the pulleys, after being stuck, would rapidly slide down the cables due to accumulation. At such moments, the cabin-cable system would experience instantaneous excitation, causing vibrations. This study uses the intrinsic time-scale decomposition (ITD) method to analyze the inertial navigation data installed in the cabin during these events, identifying modal frequencies and damping ratios. The analysis results show that the lowest primary vibration frequency of the FAST cabin-cable suspension system ranges from approximately 0.12 to 0.2 Hz, with a damping ratio of no less than 0.004. These data indicate that the current structure of FAST has a strong energy dissipation capability, providing important reference points for improving the control accuracy of FAST and for the upgrade of the feed support system.
Open AccessModal Frequency and Damping Identification of the FAST Cabin-Cable System
The Five-Hundred-Meter Aperture Spherical Radio Telescope (FAST) faces challenges in establishing high-precision rigid connections between the receiver and the reflective surface due to its vast spatial span. Innovatively, FAST suspends the feed cabin in mid-air using six supporting cables. The precise positioning of the feed focal point is achieved through the coordinated control of cable extension and retraction, along with the A-B axis and the Stewart platform within the cabin. The cables and the feed cabin form a large parallel mechanism. Since the cables are flexible, and the feed cabin remains at a high altitude during observations, it is inevitably subject to internal and external disturbances. To quickly dissipate these disturbances, the system requires a certain level of damping, which directly affects the pointing and tracking accuracy of FAST. During the 2022–2023 operational period, there were multiple instances where the pulleys of the curtain mechanism on the supporting cables became stuck and were carried to the top of the towers by the cables. This also led to the phenomenon where the pulleys, after being stuck, would rapidly slide down the cables due to accumulation. At such moments, the cabin-cable system would experience instantaneous excitation, causing vibrations. This study uses the intrinsic time-scale decomposition (ITD) method to analyze the inertial navigation data installed in the cabin during these events, identifying modal frequencies and damping ratios. The analysis results show that the lowest primary vibration frequency of the FAST cabin-cable suspension system ranges from approximately 0.12 to 0.2 Hz, with a damping ratio of no less than 0.004. These data indicate that the current structure of FAST has a strong energy dissipation capability, providing important reference points for improving the control accuracy of FAST and for the upgrade of the feed support system.
- Open Access
Wind-Induced Vibrations and Gust Response Factors of the Cabin–Cable–Tower System
A large-scale radio astronomical telescope is a typical complex coupled system, consisting of a feed cabin, cables, and supporting structures. The system is extremely sensitive to wind loads, especially the feed cabin, which has high requirements for vibration displacement during operation, and excessive vibration may affect normal operation. To investigate the wind-induced vibration characteristics of such coupled systems, this study takes the Five-hundred-meter Aperture Spherical Radio Telescope (FAST) as an example to conduct research. First, a refined finite element model of FAST is established, and a dynamic analysis using simulated random wind loads is conducted. The influence of the cable boundary on the time–frequency domain responses of the feed cabin is particularly considered. Then, the gust response factor (GRF) for different structural components within the coupled system is calculated. Finally, the evolution law of the GRF under various wind speeds and directions is revealed by parametric analysis. The parameter analysis only considers the wind directions ranging from 0° to 60°, because FAST is a symmetric structure. The results indicate that obvious differences are observed in both the rotational and translational displacements of the feed cabin under northward wind, especially the results along the east–west axis. When the supporting towers are considered, there is no change in the power spectral density (PSD) of the feed cabin in the low-frequency range. However, in the high-frequency range, taking the supporting towers into account leads to an increase in PSD and a resonance near the first-order natural frequency of the supporting tower. The GRF based on the dynamic response exhibits substantial deviations compared to those obtained from design codes, highlighting the need for an independent analysis when determining GRF for such coupled systems.
Open AccessWind-Induced Vibrations and Gust Response Factors of the Cabin–Cable–Tower System
A large-scale radio astronomical telescope is a typical complex coupled system, consisting of a feed cabin, cables, and supporting structures. The system is extremely sensitive to wind loads, especially the feed cabin, which has high requirements for vibration displacement during operation, and excessive vibration may affect normal operation. To investigate the wind-induced vibration characteristics of such coupled systems, this study takes the Five-hundred-meter Aperture Spherical Radio Telescope (FAST) as an example to conduct research. First, a refined finite element model of FAST is established, and a dynamic analysis using simulated random wind loads is conducted. The influence of the cable boundary on the time–frequency domain responses of the feed cabin is particularly considered. Then, the gust response factor (GRF) for different structural components within the coupled system is calculated. Finally, the evolution law of the GRF under various wind speeds and directions is revealed by parametric analysis. The parameter analysis only considers the wind directions ranging from 0° to 60°, because FAST is a symmetric structure. The results indicate that obvious differences are observed in both the rotational and translational displacements of the feed cabin under northward wind, especially the results along the east–west axis. When the supporting towers are considered, there is no change in the power spectral density (PSD) of the feed cabin in the low-frequency range. However, in the high-frequency range, taking the supporting towers into account leads to an increase in PSD and a resonance near the first-order natural frequency of the supporting tower. The GRF based on the dynamic response exhibits substantial deviations compared to those obtained from design codes, highlighting the need for an independent analysis when determining GRF for such coupled systems.
- Open Access
- 30 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 332
Development of a Pre-Evaluation and Health Monitoring System for FAST Cable-Net Structure
The Five-hundred-meter Aperture Spherical radio Telescope (FAST) is one of China’s major pieces of national infrastructure. A variable cable-net structure is used as the main supporting structure of the active reflector. The displacement of the cable net works through actuators. The realization of linkage control is a multi-degree-of-freedom and complex coupling control system. Due to factors such as the temperature difference between day and night, as well as actuator failure, the reflector control accuracy and even structural safety are affected during the position-control process of the cable net, so realizing evaluation of control accuracy and fault warning of the reflector is a significant problem. This paper proposes a pre-evaluation and health monitoring system based on advanced mechanical simulation technology. Through this system, on-site staff can expeditiously analyze the model to determine whether the cable net is currently in a safe state, predict the fatigue degree of the components, and maintain the structure when appropriate. The pre-evaluation and health monitoring system adequately ensure the stable functioning of the FAST cable net, improve the efficiency of on-site maintenance work, and markedly reduce the safety risk of the structure.
- 30 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 332
Open AccessDevelopment of a Pre-Evaluation and Health Monitoring System for FAST Cable-Net Structure
The Five-hundred-meter Aperture Spherical radio Telescope (FAST) is one of China’s major pieces of national infrastructure. A variable cable-net structure is used as the main supporting structure of the active reflector. The displacement of the cable net works through actuators. The realization of linkage control is a multi-degree-of-freedom and complex coupling control system. Due to factors such as the temperature difference between day and night, as well as actuator failure, the reflector control accuracy and even structural safety are affected during the position-control process of the cable net, so realizing evaluation of control accuracy and fault warning of the reflector is a significant problem. This paper proposes a pre-evaluation and health monitoring system based on advanced mechanical simulation technology. Through this system, on-site staff can expeditiously analyze the model to determine whether the cable net is currently in a safe state, predict the fatigue degree of the components, and maintain the structure when appropriate. The pre-evaluation and health monitoring system adequately ensure the stable functioning of the FAST cable net, improve the efficiency of on-site maintenance work, and markedly reduce the safety risk of the structure.
- 1 September 2017
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 17 (9) , 099
Research on design of adaptive connecting mechanisms for the cable-net and panels of FAST
The reflector system of the Five-hundred-meter Aperture Spherical radio Telescope (FAST) is designed to incorporate 4450 rigid panels supported by a flexible cable-net structure. The shape-changing operation that occurs in the process of observation will lead to a relative displacement between adjacent nodes in the cable-net. In addition, three nodes on a rigid panel are fixed with respect to each other. Thus, adaptive connecting mechanisms between panels and the cable-net are certainly needed. The present work focuses on the following aspects. Firstly, the degrees of freedom of adaptive connecting mechanisms were designed so that we can not only adapt the panel to the deformation of the cable-net, but also restrict the panel to its right place. Secondly, finite element and theoretical analyses were applied to calculate the scope of motion in adaptive connecting mechanisms during the cable-net’s shape-changing operation, thus providing input parameters for the design size of the adaptive connecting mechanisms. In addition, the gap size between the panels is also investigated to solve the trade-off between avoiding panel collisions and increasing the observation efficiency of FAST.
- 1 September 2017
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 17 (9) , 099
Research on design of adaptive connecting mechanisms for the cable-net and panels of FAST
The reflector system of the Five-hundred-meter Aperture Spherical radio Telescope (FAST) is designed to incorporate 4450 rigid panels supported by a flexible cable-net structure. The shape-changing operation that occurs in the process of observation will lead to a relative displacement between adjacent nodes in the cable-net. In addition, three nodes on a rigid panel are fixed with respect to each other. Thus, adaptive connecting mechanisms between panels and the cable-net are certainly needed. The present work focuses on the following aspects. Firstly, the degrees of freedom of adaptive connecting mechanisms were designed so that we can not only adapt the panel to the deformation of the cable-net, but also restrict the panel to its right place. Secondly, finite element and theoretical analyses were applied to calculate the scope of motion in adaptive connecting mechanisms during the cable-net’s shape-changing operation, thus providing input parameters for the design size of the adaptive connecting mechanisms. In addition, the gap size between the panels is also investigated to solve the trade-off between avoiding panel collisions and increasing the observation efficiency of FAST.
- Open Access
- 1 January 2017
- Published by Chinese Journal of Mechanical Engineering in Journal of Mechanical Engineering
- Vol. 53 (17) , 4-9
Initial Gap between Panels of the Reflector of FAST
2 南仁东 1, 2 (1. 中国科学院国家天文台 北京 100012; 2. 中国射电天文重点实验室 北京 100012)
- 1 January 2017
- Published by Chinese Journal of Mechanical Engineering in Journal of Mechanical Engineering
- Vol. 53 (17) , 4-9
Open AccessInitial Gap between Panels of the Reflector of FAST
2 南仁东 1, 2 (1. 中国科学院国家天文台 北京 100012; 2. 中国射电天文重点实验室 北京 100012)