Reinhard Gerlach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Reinhard Gerlach has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dirk Vordermark
Department of Radiation Oncology, University Hospital Halle (Saale), Halle (Saale), Germany
2 shared publications - Christian Ostheimer
Department of Radiation Oncology, Faculty of Medicine, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
1 shared publication - Christine Kornhuber
Department of Radiation Oncology, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
1 shared publication - Frithjof Lange1 shared publication
- Martin Janich
Department of Radiation Oncology, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
1 shared publication - Nico Homonnay1 shared publication
Latest Publications
- Open Access
- 8 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 651-654
Gynecological brachytherapy with Elekta microSelectron V3 afterloading system
Objective: For commissioning of source path mo-dels for ring tubes of Nucletron (now Elekta) CT/MR ring applicators, a method was established using a source position simulator (SPS) and a CT scanner. Methods: An acrylic glass support for ring tubes was constructed serving as defined coordinate system. With SPS, 40 positions were set in the ring in steps of 2.5mm from proximal to distal direction. In each position a CT-series was taken with ring plane inside scan plane using a GE Optima 580 scanner (slice width 0.625mm). Evaluation was done in multiplanar recon-struction mode under display settings revealing dummy source shape. With a 3D-cursor dwell position coordinate (center of Ir-192 core) was determined. Measurements were validated by film autoradiography in selected positions. Four rings were investigated: 60° Φ26, 45° Φ26, 60° Φ30, and 45° Φ30 with figures denoting angle between ring plane and stem and ring diameter in mm. Results: The method is feasible to reconstruct source dwell positions with an overall accuracy of ±0.3mm. Detected coordinates are consistent and in excel-lent agreement with those obtained by autoradiography. Comparison with Elekta’s source path models, however, re-vealed mean deviations of up to 3.5mm. Discussion: It is advisable to measure individual source paths and have them added to the data base of the treatment planning system.
- 8 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 651-654
Open AccessGynecological brachytherapy with Elekta microSelectron V3 afterloading system
Objective: For commissioning of source path mo-dels for ring tubes of Nucletron (now Elekta) CT/MR ring applicators, a method was established using a source position simulator (SPS) and a CT scanner. Methods: An acrylic glass support for ring tubes was constructed serving as defined coordinate system. With SPS, 40 positions were set in the ring in steps of 2.5mm from proximal to distal direction. In each position a CT-series was taken with ring plane inside scan plane using a GE Optima 580 scanner (slice width 0.625mm). Evaluation was done in multiplanar recon-struction mode under display settings revealing dummy source shape. With a 3D-cursor dwell position coordinate (center of Ir-192 core) was determined. Measurements were validated by film autoradiography in selected positions. Four rings were investigated: 60° Φ26, 45° Φ26, 60° Φ30, and 45° Φ30 with figures denoting angle between ring plane and stem and ring diameter in mm. Results: The method is feasible to reconstruct source dwell positions with an overall accuracy of ±0.3mm. Detected coordinates are consistent and in excel-lent agreement with those obtained by autoradiography. Comparison with Elekta’s source path models, however, re-vealed mean deviations of up to 3.5mm. Discussion: It is advisable to measure individual source paths and have them added to the data base of the treatment planning system.
- Open Access
- 24 March 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 82
The treatment of extensive scalp lesions using coplanar and non-coplanar photon IMRT: a single institution experience
This clinical study compared four different cases of extensive scalp malignancies treated by intensity-modulated radiation therapy. The merits of coplanar and non-coplanar Step-and-shoot total scalp irradiation techniques were evaluated against the background of the literature.
- 24 March 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 82
Open AccessThe treatment of extensive scalp lesions using coplanar and non-coplanar photon IMRT: a single institution experience
This clinical study compared four different cases of extensive scalp malignancies treated by intensity-modulated radiation therapy. The merits of coplanar and non-coplanar Step-and-shoot total scalp irradiation techniques were evaluated against the background of the literature.