Carsten Müller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carsten Müller has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Frank R. Ihmig
Affiliation Fraunhofer Institute for Biomedical Engineering IBMT, Sulzbach, Saarland, Germany
2 shared publications - Ana Cisnal
Universidad de Valladolid
1 shared publication - Javier Pérez-Turiel
Universidad de Valladolid
1 shared publication Josep M. Cardona Audí
Fraunhofer Institute for Biomedical Engineering (IBMT), St. Ingbert, Germany
1 shared publication- Juan Carlos Fraile
Universidad de Valladolid
1 shared publication Klaus-Peter Hoffmann
Fraunhofer Institute for Biomedical Engineering (IBMT), St. Ingbert, Germany
1 shared publication
Latest Publications
- Open Access
- 14 November 2019
- Published by MDPI AG in Proceedings
- Vol. 42 (1) , 61
Modeling the Nonlinear Properties of Ferroelectric Materials in Ceramic Capacitors for the Implementation of Sensor Functionalities in Implantable Electronics
For several years, the requirements on miniaturization of electronic implants with application in functional electrostimulation have been increasing, while functionality and reliability should not be impaired. One solution concept is to use neither active electronic components nor sensors or batteries. Instead, the functionalities are ensured by the use of intrinsic nonlinear properties of the already used components and energy is transferred by inductive coupling. In this paper, ceramic capacitors are investigated as a first step towards exploiting the nonlinear characteristics of ferroelectric materials. The ceramic capacitors are characterized by simulation and measurements. The modeling is carried out in Mathcad Prime 3.1 and ANSYS 2019 R2 Simplorer and different solvers are compared for exemplary calculations. Finally, a measurement setup is realized to validate the models. Calculations show that the trapezoid method with a number of 500 k points in the given solution interval is best suited for ANSYS. In Mathcad, the Adams, Bulirsch–Stoer, Backward Differentiation Formula, Radau5, and fourth order Runge–Kutta methods with an adaptive step width and a resolution of 50 k points are the most suitable. The nonlinear properties of ferroelectric materials in ceramic capacitors modeled with these methods using ANSYS and Mathcad show small and equal deviation from the measurements.
- 14 November 2019
- Published by MDPI AG in Proceedings
- Vol. 42 (1) , 61
Open AccessModeling the Nonlinear Properties of Ferroelectric Materials in Ceramic Capacitors for the Implementation of Sensor Functionalities in Implantable Electronics
For several years, the requirements on miniaturization of electronic implants with application in functional electrostimulation have been increasing, while functionality and reliability should not be impaired. One solution concept is to use neither active electronic components nor sensors or batteries. Instead, the functionalities are ensured by the use of intrinsic nonlinear properties of the already used components and energy is transferred by inductive coupling. In this paper, ceramic capacitors are investigated as a first step towards exploiting the nonlinear characteristics of ferroelectric materials. The ceramic capacitors are characterized by simulation and measurements. The modeling is carried out in Mathcad Prime 3.1 and ANSYS 2019 R2 Simplorer and different solvers are compared for exemplary calculations. Finally, a measurement setup is realized to validate the models. Calculations show that the trapezoid method with a number of 500 k points in the given solution interval is best suited for ANSYS. In Mathcad, the Adams, Bulirsch–Stoer, Backward Differentiation Formula, Radau5, and fourth order Runge–Kutta methods with an adaptive step width and a resolution of 50 k points are the most suitable. The nonlinear properties of ferroelectric materials in ceramic capacitors modeled with these methods using ANSYS and Mathcad show small and equal deviation from the measurements.
- Open Access
A Measurement Setup and Automated Calculation Method to Determine the Charge Injection Capacity of Implantable Microelectrodes
The design of safe stimulation protocols for functional electrostimulation requires knowledge of the “maximum reversible charge injection capacity” of the implantable microelectrodes. One of the main difficulties encountered in characterizing such microelectrodes is the calculation of the access voltage Va. This paper proposes a method to calculate Va that does not require prior knowledge of the overpotential terms and of the electrolyte (or excitable tissue) resistance, which is an advantage for in vivo electrochemical characterization of microelectrodes. To validate this method, we compare the calculated results with those obtained from conventional methods for characterizing three flexible platinum microelectrodes by cyclic voltammetry and voltage transient measurements. This paper presents the experimental setup, the required instrumentation, and the signal processing.
Open AccessA Measurement Setup and Automated Calculation Method to Determine the Charge Injection Capacity of Implantable Microelectrodes
The design of safe stimulation protocols for functional electrostimulation requires knowledge of the “maximum reversible charge injection capacity” of the implantable microelectrodes. One of the main difficulties encountered in characterizing such microelectrodes is the calculation of the access voltage Va. This paper proposes a method to calculate Va that does not require prior knowledge of the overpotential terms and of the electrolyte (or excitable tissue) resistance, which is an advantage for in vivo electrochemical characterization of microelectrodes. To validate this method, we compare the calculated results with those obtained from conventional methods for characterizing three flexible platinum microelectrodes by cyclic voltammetry and voltage transient measurements. This paper presents the experimental setup, the required instrumentation, and the signal processing.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 721-724
Signal and energy transmission for implanted systems
Aspects and approaches for the design of systems for simultaneous signal and energy transmission for medical implants are presented. The main focus is on the consideration of the mutual influence on both transmission lines. To minimize the influence of capacitive as well as inductive paths, that affect the transmission, reducing the number of components is discussed. In order to increase the degree of miniaturization and reliability, the realization of certain functionalities is based on the so-called parasitics of electrical components. An implementation example is presented.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 721-724
Open AccessSignal and energy transmission for implanted systems
Aspects and approaches for the design of systems for simultaneous signal and energy transmission for medical implants are presented. The main focus is on the consideration of the mutual influence on both transmission lines. To minimize the influence of capacitive as well as inductive paths, that affect the transmission, reducing the number of components is discussed. In order to increase the degree of miniaturization and reliability, the realization of certain functionalities is based on the so-called parasitics of electrical components. An implementation example is presented.