Michele Tartaglia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michele Tartaglia has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Massimo Mitolo
Irvine Valley College, Irvine, CA, USA
4 shared publications - Fabio Freschi
Dipartimento Energia G. Ferraris, Politecnico di Torino, Torino, Italy
3 shared publications A. Cavallo
1 shared publicationAlessandra Guerrisi
Department of Electrical Engineering, Politecnico di Torino, Torino, Italy
1 shared publicationB. Covili Faggioli
1 shared publicationF. Moretti
1 shared publication
Latest Publications
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (5) , 4483-4489
Electrical Safety Analysis in the Presence of Resonant Grounding Neutral
The resonant grounding is one of the possible methods of system neutral grounding for the medium voltage distribution. IEEE standards do define this grounding configuration, but important advantages and drawbacks of the resonant grounding might not be fully known, due to its rather uncommon application in North America. On the other hand, resonant grounding in Europe is imposed by the increased requirements for power quality, especially for medium-voltage industrial users, imposed to electric utilities by Regulatory Authorities, with the purpose to protect the interests of users and consumers. Level of the continuity of the service, magnitude and phase of ground-fault currents, magnitude of touch voltages, all depend on how the neutral is connected to ground. In this paper, the authors will discuss electrical safety features of the resonant ground, and analyze issues when a substation, originally operated with different methods of system neutral grounding, is reconfigured with a resonant ground. In particular, a conservative approach for preserving safety during HV-MV substations' reconfiguration is herein proposed; the cases of the substation reconfiguration from resonant grounding to isolated-from-ground and vice versa shall be analyzed. Finally, the analysis of the impact of the use of Petersen Coil on the Global Grounding Systems will be provided.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (5) , 4483-4489
Electrical Safety Analysis in the Presence of Resonant Grounding Neutral
The resonant grounding is one of the possible methods of system neutral grounding for the medium voltage distribution. IEEE standards do define this grounding configuration, but important advantages and drawbacks of the resonant grounding might not be fully known, due to its rather uncommon application in North America. On the other hand, resonant grounding in Europe is imposed by the increased requirements for power quality, especially for medium-voltage industrial users, imposed to electric utilities by Regulatory Authorities, with the purpose to protect the interests of users and consumers. Level of the continuity of the service, magnitude and phase of ground-fault currents, magnitude of touch voltages, all depend on how the neutral is connected to ground. In this paper, the authors will discuss electrical safety features of the resonant ground, and analyze issues when a substation, originally operated with different methods of system neutral grounding, is reconfigured with a resonant ground. In particular, a conservative approach for preserving safety during HV-MV substations' reconfiguration is herein proposed; the cases of the substation reconfiguration from resonant grounding to isolated-from-ground and vice versa shall be analyzed. Finally, the analysis of the impact of the use of Petersen Coil on the Global Grounding Systems will be provided.
- 1 July 2018
- Published by EJournal Publishing in Journal of Clean Energy Technologies
- Vol. 6 (4) , 314-319
Operating Results of a 20MW Biomass Generating Plant in Italy and a GIS Analysis for Exploiting Wood Availability
- 1 July 2018
- Published by EJournal Publishing in Journal of Clean Energy Technologies
- Vol. 6 (4) , 314-319
Operating Results of a 20MW Biomass Generating Plant in Italy and a GIS Analysis for Exploiting Wood Availability
- 4 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 20 (3) , 33-39
Ground-Fault Conditions in Low-Voltage Systems: Potential Differences Between Exposed Conductive Parts
In low-voltage systems, ground faults do not necessarily involve the actual earth, but fault currents may return to the source via conductors. Such conductors, which provide a clear path toward the source, are defined in the applicable codes and technical standards as equipment grounding conductors or protective conductors.
- 4 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 20 (3) , 33-39
Ground-Fault Conditions in Low-Voltage Systems: Potential Differences Between Exposed Conductive Parts
In low-voltage systems, ground faults do not necessarily involve the actual earth, but fault currents may return to the source via conductors. Such conductors, which provide a clear path toward the source, are defined in the applicable codes and technical standards as equipment grounding conductors or protective conductors.
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 49 (5) , 2290-2299
Numerical Simulation of Heart-Current Factors and Electrical Models of the Human Body
Contact with energized parts at different potentials may cause the circulation of body current and the possible inception of the ventricular fibrillation, which is generally considered the most life-threatening effect imposed on the cardiac muscle. The heart-current factors currently present in international standard have been determined owing to measurements on cadavers as well as experiments with volunteers. Due to the difficulties in experimental verifications, the authors propose the use of numerical techniques to investigate the behavior of the human body when it is subjected to electric fields, with the fundamental purpose of increasing the electrical safety of installations. This work is based on a mathematical representation of the human anatomy, which takes into account the boundaries of the internal organs. The simulations carried out and documented in this paper show results that do not entirely match the published IEC heart-current factors; most noticeably, for the pathways hands-feet, right hand-feet, and left hand-right foot, the heart-current factors seem to be overestimated by the IEC.
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 49 (5) , 2290-2299
Numerical Simulation of Heart-Current Factors and Electrical Models of the Human Body
Contact with energized parts at different potentials may cause the circulation of body current and the possible inception of the ventricular fibrillation, which is generally considered the most life-threatening effect imposed on the cardiac muscle. The heart-current factors currently present in international standard have been determined owing to measurements on cadavers as well as experiments with volunteers. Due to the difficulties in experimental verifications, the authors propose the use of numerical techniques to investigate the behavior of the human body when it is subjected to electric fields, with the fundamental purpose of increasing the electrical safety of installations. This work is based on a mathematical representation of the human anatomy, which takes into account the boundaries of the internal organs. The simulations carried out and documented in this paper show results that do not entirely match the published IEC heart-current factors; most noticeably, for the pathways hands-feet, right hand-feet, and left hand-right foot, the heart-current factors seem to be overestimated by the IEC.
- 6 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 47 (2) , 984-988
Ecodesign of Low-Voltage Systems and Exposure to ELF Magnetic Fields
The ecodesign of modern residential and commercial low-voltage systems implements energy and equipment cost savings, optimizing the size of the distribution system without compromising its functionality or causing environmental contamination, including electromagnetic pollution. Protection of persons against shock hazards should be increased, and the electrical interferences among power systems should be reduced. To achieve the aforementioned improvements, a possible ecodesign calls for an earthing system utilizing single-phase separation transformers installed in the unit and grounded at the midpoint of their secondary side. The introduction of a source of magnetic fields into the premises at the power frequency of 60/50 Hz [i.e., extremely low frequency (ELF)] might expose persons to potential adverse health effects, as well as sensitive electronic equipment to disturbances. This paper seeks to clarify this matter by evaluating the ELF magnetic fields as produced by the user's own transformer and by other units eventually present in the vicinity.
- 6 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 47 (2) , 984-988
Ecodesign of Low-Voltage Systems and Exposure to ELF Magnetic Fields
The ecodesign of modern residential and commercial low-voltage systems implements energy and equipment cost savings, optimizing the size of the distribution system without compromising its functionality or causing environmental contamination, including electromagnetic pollution. Protection of persons against shock hazards should be increased, and the electrical interferences among power systems should be reduced. To achieve the aforementioned improvements, a possible ecodesign calls for an earthing system utilizing single-phase separation transformers installed in the unit and grounded at the midpoint of their secondary side. The introduction of a source of magnetic fields into the premises at the power frequency of 60/50 Hz [i.e., extremely low frequency (ELF)] might expose persons to potential adverse health effects, as well as sensitive electronic equipment to disturbances. This paper seeks to clarify this matter by evaluating the ELF magnetic fields as produced by the user's own transformer and by other units eventually present in the vicinity.