Hong-Liang Cui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hong-Liang Cui has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Dongshan Wei
Chongqing Institute of green and intelligent technology Chinese Academy of Sciences Chongqing China
5 shared publicationsMingkun Zhang
Chongqing Institute of green and intelligent technology Chinese Academy of Sciences Chongqing China
4 shared publications- Shihan Yan
Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
4 shared publications Chunlei Du
Chongqing Institute of green and intelligent technology Chinese Academy of Sciences Chongqing China
3 shared publicationsLiangping Xia
Chongqing Institute of green and intelligent technology Chinese Academy of Sciences Chongqing China
3 shared publicationsMingjie Tang
Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing, 400714, China; University of Chinese Academy of Sciences, Beijing, 100049, China
3 shared publications
Latest Publications
- Open Access
- 1 March 2021
- Published by Elsevier in Plant Communications
- Vol. 2 (2) , 100106
A solid-state nanopore-based single-molecule approach for label-free characterization of plant polysaccharides
- 1 March 2021
- Published by Elsevier in Plant Communications
- Vol. 2 (2) , 100106
Open AccessA solid-state nanopore-based single-molecule approach for label-free characterization of plant polysaccharides
- Open Access
- 8 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (2) , 1-10
Pragmatic Implementation With Non-Gaussian Devices of Noise-Limited Weak Value Amplification
An effective approach for general measurement based on weak value amplification using non-Gaussian broadband light sources is demonstrated. This scheme can reduce the difficulty of preparing the measurement apparatus and correcting the systematic error caused by the imperfection of device's wave function, thus making the weak-value amplification scheme more convenient and robust for practical field applications. The influence of several common noise sources in a general application based on weak value amplification is analyzed theoretically and examined experimentally. A purely imaginary weak-value phase measurement system is considered for the noise model verification experimentally. In this we show how to optimize the precision of measurement in a unique solution that takes into account the interplay between precision and uncertainty, and explicate the ramifications of such a compromising and pragmatic approach
- 8 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (2) , 1-10
Open AccessPragmatic Implementation With Non-Gaussian Devices of Noise-Limited Weak Value Amplification
An effective approach for general measurement based on weak value amplification using non-Gaussian broadband light sources is demonstrated. This scheme can reduce the difficulty of preparing the measurement apparatus and correcting the systematic error caused by the imperfection of device's wave function, thus making the weak-value amplification scheme more convenient and robust for practical field applications. The influence of several common noise sources in a general application based on weak value amplification is analyzed theoretically and examined experimentally. A purely imaginary weak-value phase measurement system is considered for the noise model verification experimentally. In this we show how to optimize the precision of measurement in a unique solution that takes into account the interplay between precision and uncertainty, and explicate the ramifications of such a compromising and pragmatic approach
- 27 September 2020
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (1) , e202000315
Detection of gene mutation responsible for Huntington's disease by terahertz attenuated total reflection microfluidic spectroscopy
Terahertz absorption spectroscopy based on attenuated total reflection (ATR) from a microfluidic sample cell was designed and implemented to detect gene mutations leading to Huntington's disease (HD). The self‐developed compact ATR microfluidic system was employed to detect two groups of base‐repeated DNA molecules combined with a terahertz time‐domain spectrometer in a marker‐free manner. The first group featured different repetition patterns of oligonucleotide fragments, and the second group included the HD gene. For the oligonucleotides of different repetition patterns, there were significant differences among the three oligonucleotides with three repeats of the double bases, which could be unambiguously classified and identified; For the HD gene, it was found that the magnitude of the terahertz absorption coefficients of the four oligonucleotide solutions was, in ascending order, CAG‐4 < CAG‐16 < CAG‐32 < CAG‐40 (the numbers are the repeat times of the CAG base segment, with 40 repeats belonging to the HD gene), when the concentration of oligonucleotide was 1 mg/mL. Principal component analysis result indicated that the spectral differences of the four oligonucleotide solutions with different CAG repeat times were statistically significant and clearly distinguishable. These results demonstrate the potential of terahertz spectroscopy as a noninvasive, unmarked, fast and low‐cost assay for gene diagnosis and clinical disease detection.
- 27 September 2020
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (1) , e202000315
Detection of gene mutation responsible for Huntington's disease by terahertz attenuated total reflection microfluidic spectroscopy
Terahertz absorption spectroscopy based on attenuated total reflection (ATR) from a microfluidic sample cell was designed and implemented to detect gene mutations leading to Huntington's disease (HD). The self‐developed compact ATR microfluidic system was employed to detect two groups of base‐repeated DNA molecules combined with a terahertz time‐domain spectrometer in a marker‐free manner. The first group featured different repetition patterns of oligonucleotide fragments, and the second group included the HD gene. For the oligonucleotides of different repetition patterns, there were significant differences among the three oligonucleotides with three repeats of the double bases, which could be unambiguously classified and identified; For the HD gene, it was found that the magnitude of the terahertz absorption coefficients of the four oligonucleotide solutions was, in ascending order, CAG‐4 < CAG‐16 < CAG‐32 < CAG‐40 (the numbers are the repeat times of the CAG base segment, with 40 repeats belonging to the HD gene), when the concentration of oligonucleotide was 1 mg/mL. Principal component analysis result indicated that the spectral differences of the four oligonucleotide solutions with different CAG repeat times were statistically significant and clearly distinguishable. These results demonstrate the potential of terahertz spectroscopy as a noninvasive, unmarked, fast and low‐cost assay for gene diagnosis and clinical disease detection.
- Open Access
- 23 March 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (3) , 585
Low Voltage Graphene-Based Amplitude Modulator for High Efficiency Terahertz Modulation
In this paper, a high-efficiency terahertz amplitude modulation device based on a field-effect transistor has been proposed. The polarization insensitive modulator is designed to achieve a maximum experimental modulation depth of about 53% within 5 V of gate voltages using monolayer graphene. Moreover, the manufacturing processes are inexpensive. Two methods are adopted to improve modulation performance. For one thing, the metal metamaterial designed can effectively enhance the electromagnetic field near single-layer graphene and therefore greatly promote the graphene’s modulation ability in terahertz. For another, polyethylene oxide-based electrolytes (PEO:LiClO4) acts as a high-capacity donor, which makes it possible to dope single-layer graphene at a relatively low voltage.
- 23 March 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (3) , 585
Open AccessLow Voltage Graphene-Based Amplitude Modulator for High Efficiency Terahertz Modulation
In this paper, a high-efficiency terahertz amplitude modulation device based on a field-effect transistor has been proposed. The polarization insensitive modulator is designed to achieve a maximum experimental modulation depth of about 53% within 5 V of gate voltages using monolayer graphene. Moreover, the manufacturing processes are inexpensive. Two methods are adopted to improve modulation performance. For one thing, the metal metamaterial designed can effectively enhance the electromagnetic field near single-layer graphene and therefore greatly promote the graphene’s modulation ability in terahertz. For another, polyethylene oxide-based electrolytes (PEO:LiClO4) acts as a high-capacity donor, which makes it possible to dope single-layer graphene at a relatively low voltage.
- Open Access
Terahertz Spectroscopic Signatures of Microcystin Aptamer Solution Probed with a Microfluidic Chip
Terahertz signature detection of biological samples in aqueous solution remains a great challenge due to the strong terahertz absorption of water. Here we propose a new preparation process for fabricating a microfluidic chip and use it as an effective sensor to probe the terahertz absorption signatures of microcystin aptamer (a linear single-stranded DNA with 60 nucleotides) dissolved in TE buffer with different concentrations. The microfluidic chip made of silicon includes thousands of 2.4 μm × 2.4 μm square-cross-section channels. One repeatable terahertz absorption signature is detected and recognized around 830 GHz, fitted to a Lorentz oscillator. This signature is theorized to originate from the bending of hydrogen bonds formed between adjacent hydrated DNA bases surrounded by water molecules. Furthermore, the low-lying vibrational modes are also investigated by molecular dynamics simulations which suggest that strong resonant oscillations are highly probable in the 815–830 GHz frequency band.
Open AccessTerahertz Spectroscopic Signatures of Microcystin Aptamer Solution Probed with a Microfluidic Chip
Terahertz signature detection of biological samples in aqueous solution remains a great challenge due to the strong terahertz absorption of water. Here we propose a new preparation process for fabricating a microfluidic chip and use it as an effective sensor to probe the terahertz absorption signatures of microcystin aptamer (a linear single-stranded DNA with 60 nucleotides) dissolved in TE buffer with different concentrations. The microfluidic chip made of silicon includes thousands of 2.4 μm × 2.4 μm square-cross-section channels. One repeatable terahertz absorption signature is detected and recognized around 830 GHz, fitted to a Lorentz oscillator. This signature is theorized to originate from the bending of hydrogen bonds formed between adjacent hydrated DNA bases surrounded by water molecules. Furthermore, the low-lying vibrational modes are also investigated by molecular dynamics simulations which suggest that strong resonant oscillations are highly probable in the 815–830 GHz frequency band.
- Open Access
- 27 February 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (3) , 1350-1359
Terahertz time-domain spectroscopy of chondroitin sulfate
Chondroitin sulfate (CS), derived from cartilage tissues, is an important type of biomacromolecule. In this paper, the terahertz time-domain spectroscopy (THz-TDS) was investigated as a potential method for content detection of CS. With the increase of the CS content, the THz absorption coefficients of the CS/polyethylene mixed samples linearly increase. The refractive indices of the mixed samples also increase when the CS content increases. The extinction coefficient of CS demonstrates the THz frequency dependence to be approximately the power of 1.4, which can be explained by the effects of CS granular solids on THz scattering.
- 27 February 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (3) , 1350-1359
Open AccessTerahertz time-domain spectroscopy of chondroitin sulfate
Chondroitin sulfate (CS), derived from cartilage tissues, is an important type of biomacromolecule. In this paper, the terahertz time-domain spectroscopy (THz-TDS) was investigated as a potential method for content detection of CS. With the increase of the CS content, the THz absorption coefficients of the CS/polyethylene mixed samples linearly increase. The refractive indices of the mixed samples also increase when the CS content increases. The extinction coefficient of CS demonstrates the THz frequency dependence to be approximately the power of 1.4, which can be explained by the effects of CS granular solids on THz scattering.
- Open Access
- 4 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 10 (1) , 1-7
Graphene Terahertz Amplitude Modulation Enhanced by Square Ring Resonant Structure
A terahertz amplitude modulator based on graphene on a metallic square ring resonant structure is proposed. By separating the graphene and the metallic structure with a thin organic dielectric layer, both the resonant frequency and the amplitude of the transmission resonant peak are modulated when graphene is electrically tuned by a bias voltage. A maximal amplitude modulation depth of 72% at the frequency of 0.6 THz is achieved for the fabricated Terahertz modulator. An analysis model based on the transmission line theory is built to explore the modulation mechanism. Results of the transmission spectrum and the amplitude modulation indicate a good agreement between the transmission line theoretical predictions and the experimental measurements.
- 4 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 10 (1) , 1-7
Open AccessGraphene Terahertz Amplitude Modulation Enhanced by Square Ring Resonant Structure
A terahertz amplitude modulator based on graphene on a metallic square ring resonant structure is proposed. By separating the graphene and the metallic structure with a thin organic dielectric layer, both the resonant frequency and the amplitude of the transmission resonant peak are modulated when graphene is electrically tuned by a bias voltage. A maximal amplitude modulation depth of 72% at the frequency of 0.6 THz is achieved for the fabricated Terahertz modulator. An analysis model based on the transmission line theory is built to explore the modulation mechanism. Results of the transmission spectrum and the amplitude modulation indicate a good agreement between the transmission line theoretical predictions and the experimental measurements.
- Open Access
- 23 November 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (85) , 53963-53969
Cell viability and hydration assay based on metamaterial-enhanced terahertz spectroscopy
We analyze cell viability and hydration state of tumor cells in a label-free manner based on metamaterial-enhanced terahertz spectroscopy.
- 23 November 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (85) , 53963-53969
Open AccessCell viability and hydration assay based on metamaterial-enhanced terahertz spectroscopy
We analyze cell viability and hydration state of tumor cells in a label-free manner based on metamaterial-enhanced terahertz spectroscopy.
- 11 September 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (10) , 4427-4437
Label-free sensing of the binding state of MUC1 peptide and anti-MUC1 aptamer solution in fluidic chip by terahertz spectroscopy
The aptamer and target molecule binding reaction has been widely applied for construction of aptasensors, most of which are labeled methods. In contrast, terahertz technology proves to be a label-free sensing tool for biomedical applications. We utilize terahertz absorption spectroscopy and molecular dynamics simulation to investigate the variation of binding-induced collective vibration of hydrogen bond network in a mixed solution of MUC1 peptide and anti-MUC1 aptamer. The results show that binding-induced alterations of hydrogen bond numbers could be sensitively reflected by the variation of terahertz absorption coefficients of the mixed solution in a customized fluidic chip. The minimal detectable concentration is determined as 1 pmol/μL, which is approximately equal to the optimal immobilized concentration of aptasensors.
- 11 September 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (10) , 4427-4437
Label-free sensing of the binding state of MUC1 peptide and anti-MUC1 aptamer solution in fluidic chip by terahertz spectroscopy
The aptamer and target molecule binding reaction has been widely applied for construction of aptasensors, most of which are labeled methods. In contrast, terahertz technology proves to be a label-free sensing tool for biomedical applications. We utilize terahertz absorption spectroscopy and molecular dynamics simulation to investigate the variation of binding-induced collective vibration of hydrogen bond network in a mixed solution of MUC1 peptide and anti-MUC1 aptamer. The results show that binding-induced alterations of hydrogen bond numbers could be sensitively reflected by the variation of terahertz absorption coefficients of the mixed solution in a customized fluidic chip. The minimal detectable concentration is determined as 1 pmol/μL, which is approximately equal to the optimal immobilized concentration of aptasensors.