Tatsuya Hayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tatsuya Hayashi has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
Tosiaki Miyati
Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan
9 shared publicationsKei Fukuzawa
Department of Radiological Technology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan; Okinaka Memorial Institute for Medical Research, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan
8 shared publicationsSatoshi Saitoh
Okinaka Memorial Institute for Medical Research, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan; Department of Hepatology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan
8 shared publicationsJunji Takahashi
Department of Radiological Technology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan
7 shared publications- Shinya Kojima
Department of Radiological Technology, Faculty of Medical Technology, Teikyo University, Tokyo, Japan
7 shared publications Masakatsu Tano
Department of Radiological Technology, Toranomon Hospital, Tokyo, Japan
6 shared publications
Latest Publications
- Open Access
- 6 October 2026
- Published by Springer Nature in Scientific Reports
Mild hyperbaric oxygen modulates selected proteolytic and mitochondrial markers during cast immobilization in mice
- 6 October 2026
- Published by Springer Nature in Scientific Reports
Open AccessMild hyperbaric oxygen modulates selected proteolytic and mitochondrial markers during cast immobilization in mice
- Open Access
- 10 September 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1816-1823
Evaluation-design effects and reference-CT-defined HU-class errors in brain MRI-to-CT synthesis on SynthRAD2023: a technical note
To quantify how evaluation design affects brain MRI-to-CT synthesis performance, we analyzed 180 MRI/CT pairs from three centers in the SynthRAD2023 Task 1 dataset. A lightweight 2D U-Net was trained with a common validation-based stopping rule under slice-random, patient-random, center-stratified size-matched patient-random, and three center-held-out designs. Comparisons were descriptive. The primary outcome was whole-mask mean absolute error (MAE), supplemented by MAE within reference-CT-defined Hounsfield unit (HU) classes. MAE (mean ± standard deviation) was 94.4 ± 3.0, 100.8 ± 1.3, and 105.2 ± 2.8 HU for the random designs and 187.4 ± 6.0, 160.6 ± 7.1, and 137.4 ± 5.1 HU for centers A, B, and C held out. Slice-random testing yielded lower MAE than patient-random testing. Center-held-out testing yielded higher MAE than the center-stratified comparator, although institutional and acquisition-domain effects could not be separated. Bone errors were high across designs; adipose-range and air errors were elevated in specific center-held-out tests.
- 10 September 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1816-1823
Open AccessEvaluation-design effects and reference-CT-defined HU-class errors in brain MRI-to-CT synthesis on SynthRAD2023: a technical note
To quantify how evaluation design affects brain MRI-to-CT synthesis performance, we analyzed 180 MRI/CT pairs from three centers in the SynthRAD2023 Task 1 dataset. A lightweight 2D U-Net was trained with a common validation-based stopping rule under slice-random, patient-random, center-stratified size-matched patient-random, and three center-held-out designs. Comparisons were descriptive. The primary outcome was whole-mask mean absolute error (MAE), supplemented by MAE within reference-CT-defined Hounsfield unit (HU) classes. MAE (mean ± standard deviation) was 94.4 ± 3.0, 100.8 ± 1.3, and 105.2 ± 2.8 HU for the random designs and 187.4 ± 6.0, 160.6 ± 7.1, and 137.4 ± 5.1 HU for centers A, B, and C held out. Slice-random testing yielded lower MAE than patient-random testing. Center-held-out testing yielded higher MAE than the center-stratified comparator, although institutional and acquisition-domain effects could not be separated. Bone errors were high across designs; adipose-range and air errors were elevated in specific center-held-out tests.
- Open Access
- 4 January 2026
- Published by Springer Nature in Cureus
- Vol. 18 (1)
Deep Learning-Based Image Quality Enhancement Combining Denoising and Super-Resolution for Fat-Suppressed T2-Weighted Breast MRI: A Qualitative and Quantitative Evaluation
Introduction Fat-suppressed T2-weighted breast MRI faces a trade-off among signal-to-noise ratio (SNR), resolution, and scan time. This study evaluated the intrinsic effect of a commercial deep learning reconstruction (DLR) method, combining denoising and super-resolution, on image quality by comparing it with conventional reconstruction (Conv) generated from identical raw data. Materials and methods For this retrospective study, 49 women who underwent 3-T breast MRI were included. From the same k-space data, Conv and DLR images were produced. Qualitative assessment involved two blinded readers qualitatively scoring five image quality parameters. For quantitative analysis (n = 44 analyzable cases), regions of interest were placed to define the SNR within the pectoralis major and the contrast ratio (CR) between muscle and fat. Results Qualitatively, DLR yielded higher scores for contrast, noise, and depiction of breast parenchyma for both readers (all p < 0.001). Signal uniformity improved modestly for one reader. Artifact ratings were mixed: one reader favored DLR (p = 0.002), whereas the other showed no significant difference (p = 0.670). Inter-reader agreement was good to very good for most parameters (kappa = 0.75-0.83), but moderate for artifacts (kappa = 0.42). Quantitatively, DLR increased the SNR by approximately 31% (median 5.00 vs. 3.79; p < 0.001), while the CR changed minimally (median 0.56 vs. 0.53; p = 0.029). Conclusion These findings indicate that DLR enhances perceived conspicuity and SNR via denoising and sharpening while preserving intrinsic tissue contrast. Applying DLR without altering acquisition parameters intrinsically improves image quality, supporting future protocol optimization toward shorter scan times or higher resolution.
- 4 January 2026
- Published by Springer Nature in Cureus
- Vol. 18 (1)
Open AccessDeep Learning-Based Image Quality Enhancement Combining Denoising and Super-Resolution for Fat-Suppressed T2-Weighted Breast MRI: A Qualitative and Quantitative Evaluation
Introduction Fat-suppressed T2-weighted breast MRI faces a trade-off among signal-to-noise ratio (SNR), resolution, and scan time. This study evaluated the intrinsic effect of a commercial deep learning reconstruction (DLR) method, combining denoising and super-resolution, on image quality by comparing it with conventional reconstruction (Conv) generated from identical raw data. Materials and methods For this retrospective study, 49 women who underwent 3-T breast MRI were included. From the same k-space data, Conv and DLR images were produced. Qualitative assessment involved two blinded readers qualitatively scoring five image quality parameters. For quantitative analysis (n = 44 analyzable cases), regions of interest were placed to define the SNR within the pectoralis major and the contrast ratio (CR) between muscle and fat. Results Qualitatively, DLR yielded higher scores for contrast, noise, and depiction of breast parenchyma for both readers (all p < 0.001). Signal uniformity improved modestly for one reader. Artifact ratings were mixed: one reader favored DLR (p = 0.002), whereas the other showed no significant difference (p = 0.670). Inter-reader agreement was good to very good for most parameters (kappa = 0.75-0.83), but moderate for artifacts (kappa = 0.42). Quantitatively, DLR increased the SNR by approximately 31% (median 5.00 vs. 3.79; p < 0.001), while the CR changed minimally (median 0.56 vs. 0.53; p = 0.029). Conclusion These findings indicate that DLR enhances perceived conspicuity and SNR via denoising and sharpening while preserving intrinsic tissue contrast. Applying DLR without altering acquisition parameters intrinsically improves image quality, supporting future protocol optimization toward shorter scan times or higher resolution.
- Open Access
- 13 November 2025
- Published by JMIR Publications Inc. in JMIR Medical Education
- Vol. 11, e81807
Large Language Models for the National Radiological Technologist Licensure Examination in Japan: Cross-Sectional Comparative Benchmarking and Evaluation of Model-Generated Items Study
Background: Mock examinations are widely used in health professional education to assess learning and prepare candidates for national licensure. However, instructor-written multiple-choice items can vary in difficulty, coverage, and clarity. Recently, large language models (LLMs) have achieved high accuracy in medical examinations, highlighting their potential for assisting item-bank development; however, their educational quality remains insufficiently characterized. Objective: This study aimed to (1) identify the most accurate LLM for the Japanese National Examination for Radiological Technologists and (2) use the top model to generate blueprint-aligned multiple-choice questions and evaluate their educational quality. Methods: Four LLMs—OpenAI o3, o4-mini, o4-mini-high (OpenAI), and Gemini 2.5 Flash (Google)—were evaluated on all 200 items of the 77th Japanese National Examination for Radiological Technologists in 2025. Accuracy was analyzed for overall items and for 173 nonimage items. The best-performing model (o3) then generated 192 original items across 14 subjects by matching the official blueprint (image-based items were excluded). Subject-matter experts (≥5 y as coordinators and routine mock examination authors) independently rated each generated item on five criteria using a 5-point scale (1=unacceptable, 5=adoptable): item difficulty, factual accuracy, accuracy of content coverage, appropriateness of wording, and instructional usefulness. Cochran Q with Bonferroni-adjusted McNemar tests compared model accuracies, and one-sided Wilcoxon signed-rank tests assessed whether the median ratings exceeded 4. Results: OpenAI o3 achieved the highest accuracy overall (90.0%; 95% CI 85.1%‐93.4%) and on nonimage items (92.5%; 95% CI 87.6%‐95.6%), significantly outperforming o4-mini on the full set ( P =.02). Across models, accuracy differences on the non-image subset were not significant (Cochran Q, P =.10). Using o3, the 192 generated items received high expert ratings for item difficulty (mean, 4.29; 95% CI 4.11‐4.46), factual accuracy (4.18; 95% CI 3.98‐4.38), and content coverage (4.73; 95% CI 4.60‐4.86). Ratings were comparatively lower for appropriateness of wording (3.92; 95% CI 3.73‐4.11) and instructional usefulness (3.60; 95% CI 3.41‐3.80). For these two criteria, the tests did not support a median rating >4 (one-sided Wilcoxon, P =.45 and P ≥.99, respectively). Representative low-rated examples (ratings 1‐2) and the rationale for those scores—such as ambiguous phrasing or generic explanations without linkage to stem cues—are provided in the supplementary materials. Conclusions: OpenAI o3 can generate radiological licensure items that align with national standards in terms of difficulty, factual correctness, and blueprint coverage. However, wording clarity and the pedagogical specificity of explanations were weaker and did not meet an adoptable threshold without further editorial refinement. These findings support a practical workflow in which LLMs draft syllabus-aligned items at scale, while faculty perform targeted edits to ensure clarity and formative feedback. Future studies should evaluate image-inclusive generation, use Application Programming Interface (API)-pinned model snapshots to increase reproducibility, and develop guidance to improve explanation quality for learner remediation.
- 13 November 2025
- Published by JMIR Publications Inc. in JMIR Medical Education
- Vol. 11, e81807
Open AccessLarge Language Models for the National Radiological Technologist Licensure Examination in Japan: Cross-Sectional Comparative Benchmarking and Evaluation of Model-Generated Items Study
Background: Mock examinations are widely used in health professional education to assess learning and prepare candidates for national licensure. However, instructor-written multiple-choice items can vary in difficulty, coverage, and clarity. Recently, large language models (LLMs) have achieved high accuracy in medical examinations, highlighting their potential for assisting item-bank development; however, their educational quality remains insufficiently characterized. Objective: This study aimed to (1) identify the most accurate LLM for the Japanese National Examination for Radiological Technologists and (2) use the top model to generate blueprint-aligned multiple-choice questions and evaluate their educational quality. Methods: Four LLMs—OpenAI o3, o4-mini, o4-mini-high (OpenAI), and Gemini 2.5 Flash (Google)—were evaluated on all 200 items of the 77th Japanese National Examination for Radiological Technologists in 2025. Accuracy was analyzed for overall items and for 173 nonimage items. The best-performing model (o3) then generated 192 original items across 14 subjects by matching the official blueprint (image-based items were excluded). Subject-matter experts (≥5 y as coordinators and routine mock examination authors) independently rated each generated item on five criteria using a 5-point scale (1=unacceptable, 5=adoptable): item difficulty, factual accuracy, accuracy of content coverage, appropriateness of wording, and instructional usefulness. Cochran Q with Bonferroni-adjusted McNemar tests compared model accuracies, and one-sided Wilcoxon signed-rank tests assessed whether the median ratings exceeded 4. Results: OpenAI o3 achieved the highest accuracy overall (90.0%; 95% CI 85.1%‐93.4%) and on nonimage items (92.5%; 95% CI 87.6%‐95.6%), significantly outperforming o4-mini on the full set ( P =.02). Across models, accuracy differences on the non-image subset were not significant (Cochran Q, P =.10). Using o3, the 192 generated items received high expert ratings for item difficulty (mean, 4.29; 95% CI 4.11‐4.46), factual accuracy (4.18; 95% CI 3.98‐4.38), and content coverage (4.73; 95% CI 4.60‐4.86). Ratings were comparatively lower for appropriateness of wording (3.92; 95% CI 3.73‐4.11) and instructional usefulness (3.60; 95% CI 3.41‐3.80). For these two criteria, the tests did not support a median rating >4 (one-sided Wilcoxon, P =.45 and P ≥.99, respectively). Representative low-rated examples (ratings 1‐2) and the rationale for those scores—such as ambiguous phrasing or generic explanations without linkage to stem cues—are provided in the supplementary materials. Conclusions: OpenAI o3 can generate radiological licensure items that align with national standards in terms of difficulty, factual correctness, and blueprint coverage. However, wording clarity and the pedagogical specificity of explanations were weaker and did not meet an adoptable threshold without further editorial refinement. These findings support a practical workflow in which LLMs draft syllabus-aligned items at scale, while faculty perform targeted edits to ensure clarity and formative feedback. Future studies should evaluate image-inclusive generation, use Application Programming Interface (API)-pinned model snapshots to increase reproducibility, and develop guidance to improve explanation quality for learner remediation.
- Open Access
- 29 October 2025
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 14 (10)
Automatic SNR measurement of brain MR images using a deep learning-based approach
Background: Signal-to-noise ratio (SNR) is a key metric for evaluating MRI image quality, but conventional measurement methods are time-consuming and operator-dependent. Deep learning offers potential for automating this process. Purpose: To develop and validate a deep learning-based method for automatic SNR measurement from single MRI images. Material and methods: A Pix2Pix framework with a U-Net++ generator and GAN-based discriminator was trained using axial brain MRI images (T1WI, T2WI, and FLAIR) from a 3T scanner. The model generated signal and noise maps from a single image, and SNR maps were computed by pixel-wise division. Whole-brain, white matter (WM), and cerebrospinal fluid (CSF) regions were automatically segmented for regional SNR measurement. The subtraction-map method served as the reference. Structural similarity index (SSIM), correlation coefficients, and Bland–Altman analyses were used to evaluate agreement. Results: Across all sequences, the mean SSIM was 0.95 ± 0.02. SNR values showed strong correlations with the reference method ( r > 0.86) and low relative errors (<7%) for whole-brain, WM, and CSF. Bland–Altman analysis demonstrated a small paired bias and narrow 95% limits of agreement across sequences. Conclusion: The proposed deep learning method enables automatic, accurate, and observer-independent SNR quantification from single MR images, supporting clinical and research image quality evaluation.
- 29 October 2025
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 14 (10)
Open AccessAutomatic SNR measurement of brain MR images using a deep learning-based approach
Background: Signal-to-noise ratio (SNR) is a key metric for evaluating MRI image quality, but conventional measurement methods are time-consuming and operator-dependent. Deep learning offers potential for automating this process. Purpose: To develop and validate a deep learning-based method for automatic SNR measurement from single MRI images. Material and methods: A Pix2Pix framework with a U-Net++ generator and GAN-based discriminator was trained using axial brain MRI images (T1WI, T2WI, and FLAIR) from a 3T scanner. The model generated signal and noise maps from a single image, and SNR maps were computed by pixel-wise division. Whole-brain, white matter (WM), and cerebrospinal fluid (CSF) regions were automatically segmented for regional SNR measurement. The subtraction-map method served as the reference. Structural similarity index (SSIM), correlation coefficients, and Bland–Altman analyses were used to evaluate agreement. Results: Across all sequences, the mean SSIM was 0.95 ± 0.02. SNR values showed strong correlations with the reference method ( r > 0.86) and low relative errors (<7%) for whole-brain, WM, and CSF. Bland–Altman analysis demonstrated a small paired bias and narrow 95% limits of agreement across sequences. Conclusion: The proposed deep learning method enables automatic, accurate, and observer-independent SNR quantification from single MR images, supporting clinical and research image quality evaluation.
- Open Access
- 8 August 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Large Language Model-Based Generation and Assessment of Radiological Technologist Licensure Exam Items in Japan (Preprint)
BACKGROUND For health professionals, mock examinations are an essential tool for assessing learning outcomes and reinforcing preparation for national licensure. However, traditionally written items are often inconsistent in difficulty, coverage, and clarity. Meanwhile, large language models (LLMs) have demonstrated high accuracy in medical exams and could potentially support the development of item banks, but the educational quality of artificial intelligence (AI)-generated questions remains underexplored. OBJECTIVE To identify the most accurate LLM for the Japanese National Examination for Radiological Technologists and, using that model, to generate and evaluate blueprint‑aligned multiple‑choice questions. METHODS Four LLMs, OpenAI o3, o4-mini, o4-mini-high (OpenAI), and Gemini 2.5 Flash (Google), were evaluated for their accuracy across all 200 items of the 77th Japanese National Examination for Radiological Technologists. The model with the highest accuracy (OpenAI o3) was then used to generate 192 multiple-choice items, adhering to the official blueprint. Expert reviewers rated these AI-generated items across five educational criteria: item difficulty, factual accuracy, content coverage, appropriateness of wording, and instructional usefulness. Statistical analyses were applied to compare model performance and item quality. RESULTS OpenAI o3 achieved the highest accuracy overall (90.0%) and on non-image items (92.5%), significantly outperforming o4-mini on the full set (P = 0.0234). Based on the expert reviewers’ scores, the AI-generated items strongly performed in terms of item difficulty (4.29), factual accuracy (4.18), and content coverage (4.73), whereas significantly lower scores were seen for appropriateness of wording (3.92) and instructional usefulness (3.60) (P < 0.05). CONCLUSIONS OpenAI o3 can generate radiological licensure questions aligned with national standards in terms of difficulty and content accuracy. There are limitations in wording clarity and pedagogical feedback, although these can be addressed through editorial review. This approach can facilitate efficient collaboration between AI and faculty in developing mock exams and also holds promise for supporting scalable, syllabus-aligned assessment in health professional education.
- 8 August 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessLarge Language Model-Based Generation and Assessment of Radiological Technologist Licensure Exam Items in Japan (Preprint)
BACKGROUND For health professionals, mock examinations are an essential tool for assessing learning outcomes and reinforcing preparation for national licensure. However, traditionally written items are often inconsistent in difficulty, coverage, and clarity. Meanwhile, large language models (LLMs) have demonstrated high accuracy in medical exams and could potentially support the development of item banks, but the educational quality of artificial intelligence (AI)-generated questions remains underexplored. OBJECTIVE To identify the most accurate LLM for the Japanese National Examination for Radiological Technologists and, using that model, to generate and evaluate blueprint‑aligned multiple‑choice questions. METHODS Four LLMs, OpenAI o3, o4-mini, o4-mini-high (OpenAI), and Gemini 2.5 Flash (Google), were evaluated for their accuracy across all 200 items of the 77th Japanese National Examination for Radiological Technologists. The model with the highest accuracy (OpenAI o3) was then used to generate 192 multiple-choice items, adhering to the official blueprint. Expert reviewers rated these AI-generated items across five educational criteria: item difficulty, factual accuracy, content coverage, appropriateness of wording, and instructional usefulness. Statistical analyses were applied to compare model performance and item quality. RESULTS OpenAI o3 achieved the highest accuracy overall (90.0%) and on non-image items (92.5%), significantly outperforming o4-mini on the full set (P = 0.0234). Based on the expert reviewers’ scores, the AI-generated items strongly performed in terms of item difficulty (4.29), factual accuracy (4.18), and content coverage (4.73), whereas significantly lower scores were seen for appropriateness of wording (3.92) and instructional usefulness (3.60) (P < 0.05). CONCLUSIONS OpenAI o3 can generate radiological licensure questions aligned with national standards in terms of difficulty and content accuracy. There are limitations in wording clarity and pedagogical feedback, although these can be addressed through editorial review. This approach can facilitate efficient collaboration between AI and faculty in developing mock exams and also holds promise for supporting scalable, syllabus-aligned assessment in health professional education.
- Open Access
- 5 May 2025
- Published by Wiley in Physiological Reports
- Vol. 13 (9) , e70350
Mild hyperbaric oxygen enhances recovery of the plantaris muscle atrophy induced by cast immobilization of the hindlimb in male rats
Loss of muscle mass is associated with muscle functional decline and mortality. The present study aimed to determine whether exposure to mild hyperbaric oxygen (MHO) during and after casting immobilization reduces muscle atrophy. We distributed eight‐week‐old rats into control (CON), cast immobilization (Cast), and Cast + MHO (1.3 atmosphere absolute with 38% oxygen) groups. Rats were cast for 2 weeks under the normal or MHO condition, followed by a two‐week recovery period under the same condition after cast removal. The plantaris muscle weight (mg/g BW) decreased by approximately 11.5% in the Cast group compared to the CON group (p < 0.01), while there were no differences between the CON and Cast + MHO groups, suggesting that MHO enhanced the recovery of muscle atrophy. However, the soleus muscle weight (mg/g BW) decreased by casting immobilization, regardless of MHO. The enzyme activity by succinate dehydrogenase (SDH) staining in the plantaris muscle was lower in the Cast group than in the CON group (p < 0.01), while there were no differences between the CON and Cast + MHO groups. In summary, MHO enhances the recovery of plantaris muscle atrophy and partially attenuates the decreased SDH activity after cast immobilization of hindlimb in rats.
- 5 May 2025
- Published by Wiley in Physiological Reports
- Vol. 13 (9) , e70350
Open AccessMild hyperbaric oxygen enhances recovery of the plantaris muscle atrophy induced by cast immobilization of the hindlimb in male rats
Loss of muscle mass is associated with muscle functional decline and mortality. The present study aimed to determine whether exposure to mild hyperbaric oxygen (MHO) during and after casting immobilization reduces muscle atrophy. We distributed eight‐week‐old rats into control (CON), cast immobilization (Cast), and Cast + MHO (1.3 atmosphere absolute with 38% oxygen) groups. Rats were cast for 2 weeks under the normal or MHO condition, followed by a two‐week recovery period under the same condition after cast removal. The plantaris muscle weight (mg/g BW) decreased by approximately 11.5% in the Cast group compared to the CON group (p < 0.01), while there were no differences between the CON and Cast + MHO groups, suggesting that MHO enhanced the recovery of muscle atrophy. However, the soleus muscle weight (mg/g BW) decreased by casting immobilization, regardless of MHO. The enzyme activity by succinate dehydrogenase (SDH) staining in the plantaris muscle was lower in the Cast group than in the CON group (p < 0.01), while there were no differences between the CON and Cast + MHO groups. In summary, MHO enhances the recovery of plantaris muscle atrophy and partially attenuates the decreased SDH activity after cast immobilization of hindlimb in rats.
- 19 July 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (3) , 782-792
Clinical application of single-shot fast spin-echo sequence for cerebrospinal fluid flow MR imaging
In normal-pressure hydrocephalus, disturbances in cerebrospinal fluid (CSF) circulation occur; therefore, understanding CSF dynamics is crucial. The two-dimensional phase-contrast (2D-PC) method, a common approach for visualizing CSF flow on MRI, often presents challenges owing to prominent vein signals and excessively high contrast, hindering the interpretation of morphological information. Therefore, we devised a new imaging method that utilizes T2-weighted high-signal intensification of the CSF and saturation pulses, without requiring specialized imaging sequences. This sequence utilized a T2-weighted single-shot fast spin-echo combined with multi-phase imaging synchronized with a pulse wave. Optimal imaging conditions (repetition time, presence/absence of fast recovery, and echo time) were determined using self-made contrast and single-plate phantoms to evaluate signal-to-noise ratio, contrast ratio, and spatial resolution. In certain clinical cases of hydrocephalus, confirming CSF flow using 2D-PC was challenging. However, our method enabled the visualization of CSF flow, proving to be useful in understanding the pathophysiology of hydrocephalus.
- 19 July 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (3) , 782-792
Clinical application of single-shot fast spin-echo sequence for cerebrospinal fluid flow MR imaging
In normal-pressure hydrocephalus, disturbances in cerebrospinal fluid (CSF) circulation occur; therefore, understanding CSF dynamics is crucial. The two-dimensional phase-contrast (2D-PC) method, a common approach for visualizing CSF flow on MRI, often presents challenges owing to prominent vein signals and excessively high contrast, hindering the interpretation of morphological information. Therefore, we devised a new imaging method that utilizes T2-weighted high-signal intensification of the CSF and saturation pulses, without requiring specialized imaging sequences. This sequence utilized a T2-weighted single-shot fast spin-echo combined with multi-phase imaging synchronized with a pulse wave. Optimal imaging conditions (repetition time, presence/absence of fast recovery, and echo time) were determined using self-made contrast and single-plate phantoms to evaluate signal-to-noise ratio, contrast ratio, and spatial resolution. In certain clinical cases of hydrocephalus, confirming CSF flow using 2D-PC was challenging. However, our method enabled the visualization of CSF flow, proving to be useful in understanding the pathophysiology of hydrocephalus.
- 10 May 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (3) , 637-644
Influence of Gd-EOB-DTPA on proton-density fat fraction in the liver using chemical shift-encoded magnetic resonance imaging at 3-T
Non-alcoholic fatty liver disease (NAFLD) and its advanced stage, non-alcoholic steatohepatitis (NASH), have become increasingly prevalent owing to the rise in metabolic syndromes. Accurate assessment of hepatic fat deposition and inflammation is crucial for diagnosing and managing NAFLD/NASH. We investigated the influence of Gd-EOB-DTPA, (EOB) on proton-density fat fraction (PDFF) measurements using chemical shift-encoded magnetic resonance imaging (CSE-MRI) at 3-T. In total, 431 patients who underwent EOB contrast-enhanced MRI were included. PDFF measurements were obtained from pre- and post-contrast CSE-MRI. Linear regression and Bland–Altman analyses were performed to assess the correlation and agreement between pre- and post-EOB PDFF measurements. Relative enhancement (RE) of the liver was calculated as an EOB uptake index. There was a significant decrease in PDFF following EOB administration compared with the pre-contrast values (P < 0.0001), which was observed across all PDFF ranges (< 10% and ≥ 10%). Linear regression analysis revealed high correlation between pre- and post-EOB PDFF measurements. Bland–Altman analysis indicated a small bias between pre- and post-EOB PDFF values. Subgroup analysis based on RE showed a significant difference in ΔPDFF between patients with high RE (> 120%) and those with lower RE levels. EOB administration resulted in a slight decrease in PDFF measurements obtained using CSE-MRI at 3-T. We were able to generalize and clarify that the PDFF of the liver on 3D CSE-MRI at 3-T was slightly decreased after EOB administration as we used a larger group of patients compared to previous studies.
- 10 May 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (3) , 637-644
Influence of Gd-EOB-DTPA on proton-density fat fraction in the liver using chemical shift-encoded magnetic resonance imaging at 3-T
Non-alcoholic fatty liver disease (NAFLD) and its advanced stage, non-alcoholic steatohepatitis (NASH), have become increasingly prevalent owing to the rise in metabolic syndromes. Accurate assessment of hepatic fat deposition and inflammation is crucial for diagnosing and managing NAFLD/NASH. We investigated the influence of Gd-EOB-DTPA, (EOB) on proton-density fat fraction (PDFF) measurements using chemical shift-encoded magnetic resonance imaging (CSE-MRI) at 3-T. In total, 431 patients who underwent EOB contrast-enhanced MRI were included. PDFF measurements were obtained from pre- and post-contrast CSE-MRI. Linear regression and Bland–Altman analyses were performed to assess the correlation and agreement between pre- and post-EOB PDFF measurements. Relative enhancement (RE) of the liver was calculated as an EOB uptake index. There was a significant decrease in PDFF following EOB administration compared with the pre-contrast values (P < 0.0001), which was observed across all PDFF ranges (< 10% and ≥ 10%). Linear regression analysis revealed high correlation between pre- and post-EOB PDFF measurements. Bland–Altman analysis indicated a small bias between pre- and post-EOB PDFF values. Subgroup analysis based on RE showed a significant difference in ΔPDFF between patients with high RE (> 120%) and those with lower RE levels. EOB administration resulted in a slight decrease in PDFF measurements obtained using CSE-MRI at 3-T. We were able to generalize and clarify that the PDFF of the liver on 3D CSE-MRI at 3-T was slightly decreased after EOB administration as we used a larger group of patients compared to previous studies.
- 28 December 2023
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (1) , 186-194
Evaluation of deep learning reconstruction on diffusion-weighted imaging quality and apparent diffusion coefficient using an ice-water phantom
This study assessed the influence of deep learning reconstruction (DLR) on the quality of diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) using an ice-water phantom. An ice-water phantom with known diffusion properties (true ADC = 1.1 × 10–3 mm2/s at 0 °C) was imaged at various b-values (0, 1000, 2000, and 4000 s/mm2) using a 3 T magnetic resonance imaging scanner with slice thicknesses of 1.5 and 3.0 mm. All DWIs were reconstructed with or without DLR. ADC maps were generated using combinations of b-values 0 and 1000, 0 and 2000, and 0 and 4000 s/mm2. Based on the quantitative imaging biomarker alliance profile, the signal-to-noise ratio (SNRs) in DWIs was calculated, and the accuracy, precision, and within-subject parameter variance (wCV) of the ADCs were evaluated. DLR improved the SNR in DWIs with b-values ranging from 0 to 2000s/mm2; however, its effectiveness was diminished at 4000 s/mm2. There was no noticeable difference in the ADCs of images generated with or without implementing DLR. For a slice thickness of 1.5 mm and combined b-values of 0 and 4000 s/mm2, the ADC values were 0.97 × 10–3and 0.98 × 10–3mm2/s with and without DLR, respectively, both being lower than the true ADC value. Furthermore, DLR enhanced the precision and wCV of the ADC measurements. DLR can enhance the SNR, repeatability, and precision of ADC measurements; however, it does not improve their accuracies.
- 28 December 2023
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (1) , 186-194
Evaluation of deep learning reconstruction on diffusion-weighted imaging quality and apparent diffusion coefficient using an ice-water phantom
This study assessed the influence of deep learning reconstruction (DLR) on the quality of diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) using an ice-water phantom. An ice-water phantom with known diffusion properties (true ADC = 1.1 × 10–3 mm2/s at 0 °C) was imaged at various b-values (0, 1000, 2000, and 4000 s/mm2) using a 3 T magnetic resonance imaging scanner with slice thicknesses of 1.5 and 3.0 mm. All DWIs were reconstructed with or without DLR. ADC maps were generated using combinations of b-values 0 and 1000, 0 and 2000, and 0 and 4000 s/mm2. Based on the quantitative imaging biomarker alliance profile, the signal-to-noise ratio (SNRs) in DWIs was calculated, and the accuracy, precision, and within-subject parameter variance (wCV) of the ADCs were evaluated. DLR improved the SNR in DWIs with b-values ranging from 0 to 2000s/mm2; however, its effectiveness was diminished at 4000 s/mm2. There was no noticeable difference in the ADCs of images generated with or without implementing DLR. For a slice thickness of 1.5 mm and combined b-values of 0 and 4000 s/mm2, the ADC values were 0.97 × 10–3and 0.98 × 10–3mm2/s with and without DLR, respectively, both being lower than the true ADC value. Furthermore, DLR enhanced the precision and wCV of the ADC measurements. DLR can enhance the SNR, repeatability, and precision of ADC measurements; however, it does not improve their accuracies.