Emma Brunton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Emma Brunton has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Kianoush Nazarpour
School of Informatics, University of Edinburgh
8 shared publications Carolina Silveira
School of Engineering, Newcastle University, Newcastle-upon-Tyne, UK
4 shared publications- Adrien Rapeaux
Imperial College London Faculty of Engineering, Imperial College London, London, SW7 2AZ, United Kingdom of Great Britain and Northern Ireland
2 shared publications Christoph W. Blau
Faculty of Medical Sciences, Newcastle University, Newcastle-upon-Tyne, NE1 7RU, Newcastle, UK
2 shared publicationsJohn Riddell
Institute of Neuroscience and Psychology, University of Glasgow, UK
2 shared publicationsSally Spendiff
Institute of Genetic Medicine, Newcastle University, Newcastle-upon- Tyne, UK
2 shared publications
Latest Publications
- Open Access
- 10 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (5) , 1079-1087
SenseBack - An Implantable System for Bidirectional Neural Interfacing
Chronic in-vivo neurophysiology experiments require highly miniaturized, remotely powered multi-channel neural interfaces which are currently lacking in power or flexibility post implantation. To resolve this problem we present the SenseBack system, a post-implantation reprogrammable wireless 32-channel bidirectional neural interfacing device that can enable chronic peripheral electrophysiology experiments in freely behaving small animals. The large number of channels for a peripheral neural interface, coupled with fully implantable hardware and complete software flexibility enable complex in-vivo studies where the system can adapt to evolving study needs as they arise. In complementary \textit{ex-vivo} and \textit{in-vivo} preparations, we demonstrate that this system can record neural signals and perform high-voltage, bipolar stimulation on any channel. In addition, we demonstrate transcutaneous power delivery and Bluetooth 5 data communication with a PC. The SenseBack system is capable of stimulation on any channel with 20 V of compliance and up to 315 A of current, and highly configurable recording with per-channel adjustable gain and filtering with 8 sets of 10-bit ADCs to sample data at 20 kHz for each channel. To our knowledge this is the first such implantable research platform offering this level of performance and flexibility post-implantation (including complete reprogramming even after encapsulation) for small animal electrophysiology. Here we present initial acute trials, demonstrations and progress towards a system that we expect to enable a wide range of electrophysiology experiments in freely behaving animals.
- 10 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (5) , 1079-1087
Open AccessSenseBack - An Implantable System for Bidirectional Neural Interfacing
Chronic in-vivo neurophysiology experiments require highly miniaturized, remotely powered multi-channel neural interfaces which are currently lacking in power or flexibility post implantation. To resolve this problem we present the SenseBack system, a post-implantation reprogrammable wireless 32-channel bidirectional neural interfacing device that can enable chronic peripheral electrophysiology experiments in freely behaving small animals. The large number of channels for a peripheral neural interface, coupled with fully implantable hardware and complete software flexibility enable complex in-vivo studies where the system can adapt to evolving study needs as they arise. In complementary \textit{ex-vivo} and \textit{in-vivo} preparations, we demonstrate that this system can record neural signals and perform high-voltage, bipolar stimulation on any channel. In addition, we demonstrate transcutaneous power delivery and Bluetooth 5 data communication with a PC. The SenseBack system is capable of stimulation on any channel with 20 V of compliance and up to 315 A of current, and highly configurable recording with per-channel adjustable gain and filtering with 8 sets of 10-bit ADCs to sample data at 20 kHz for each channel. To our knowledge this is the first such implantable research platform offering this level of performance and flexibility post-implantation (including complete reprogramming even after encapsulation) for small animal electrophysiology. Here we present initial acute trials, demonstrations and progress towards a system that we expect to enable a wide range of electrophysiology experiments in freely behaving animals.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 27 (9) , 1676-1683
Temporal Modulation of the Response of Sensory Fibers to Paired-Pulse Stimulation
Multi-channel nerve cuff electrode arrays can provide sensory feedback to prosthesis users. To develop efficacious stimulation protocols, an understanding of the impact that spatio-temporal patterned stimulation can have on the response of sensory fibers is crucial. We used experimental and modelling methods to investigate the response of nerve fibers to paired-pulse stimulation. Nerve cuff electrode arrays were implanted for stimulation of the sciatic nerves of rats and the sensory compound action potentials were recorded from the L4 dorsal root. A model of the nerve cuff electrode array and sciatic nerve was also developed. The experimental and modelling results were compared. Experiments showed that it took 8 ms for the sensory fibers to completely recover from a conditioning stimulus, regardless of the relative position of the electrodes used for stimulation. The results demonstrate that the electrodes on the cuff cannot be considered independent. Additionally, at 120% of the threshold, there is a large overlap in the fibers that were activated by the different electrodes. If a stimulus paradigm considered the electrodes as independent, stimuli from the different electrodes would need to be interleaved, and the intervals between the stimuli should be greater than 8 ms.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 27 (9) , 1676-1683
Temporal Modulation of the Response of Sensory Fibers to Paired-Pulse Stimulation
Multi-channel nerve cuff electrode arrays can provide sensory feedback to prosthesis users. To develop efficacious stimulation protocols, an understanding of the impact that spatio-temporal patterned stimulation can have on the response of sensory fibers is crucial. We used experimental and modelling methods to investigate the response of nerve fibers to paired-pulse stimulation. Nerve cuff electrode arrays were implanted for stimulation of the sciatic nerves of rats and the sensory compound action potentials were recorded from the L4 dorsal root. A model of the nerve cuff electrode array and sciatic nerve was also developed. The experimental and modelling results were compared. Experiments showed that it took 8 ms for the sensory fibers to completely recover from a conditioning stimulus, regardless of the relative position of the electrodes used for stimulation. The results demonstrate that the electrodes on the cuff cannot be considered independent. Additionally, at 120% of the threshold, there is a large overlap in the fibers that were activated by the different electrodes. If a stimulus paradigm considered the electrodes as independent, stimuli from the different electrodes would need to be interleaved, and the intervals between the stimuli should be greater than 8 ms.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2018, 2430-2433
Positioning the Nerve Cuff Distally on the Sciatic Nerve Improves the Classification of Ankle-Movement Proprioceptive ENG Signals
Recording of neural signals from intact peripheral nerves in patients with spinal cord injury or stroke survivors offers the possibility for the development of closed-loop sensorimotor prostheses. However, questions remain over the positioning of neural interfaces such that the separability of neural data recorded from the peripheral nerves is improved. Afferent electroneurographic signals were recorded with nerve cuffs placed on the sciatic nerve of rats in response to various mechanical stimuli to the hindpaw. The mean absolute value of the signal was extracted and fed into classifiers. The performance of the classifier was evaluated when information was available from a single cuff placed either distally or proximally on the sciatic nerve. Results confirmed earlier findings that proprioceptive ENG signals, elicited by the movement of the ankle, can be identified and separated in neural recordings made with a cuff electrode. In addition, classification scores improved when the nerve cuff was placed distally on the nerve rather than proximally, taking advantage of the nerve's underlying anatomy.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2018, 2430-2433
Positioning the Nerve Cuff Distally on the Sciatic Nerve Improves the Classification of Ankle-Movement Proprioceptive ENG Signals
Recording of neural signals from intact peripheral nerves in patients with spinal cord injury or stroke survivors offers the possibility for the development of closed-loop sensorimotor prostheses. However, questions remain over the positioning of neural interfaces such that the separability of neural data recorded from the peripheral nerves is improved. Afferent electroneurographic signals were recorded with nerve cuffs placed on the sciatic nerve of rats in response to various mechanical stimuli to the hindpaw. The mean absolute value of the signal was extracted and fed into classifiers. The performance of the classifier was evaluated when information was available from a single cuff placed either distally or proximally on the sciatic nerve. Results confirmed earlier findings that proprioceptive ENG signals, elicited by the movement of the ankle, can be identified and separated in neural recordings made with a cuff electrode. In addition, classification scores improved when the nerve cuff was placed distally on the nerve rather than proximally, taking advantage of the nerve's underlying anatomy.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2018, 1214-1217
Recovery of the Response of Sensory Fibers to the Second of a Pair of Peripheral Nerve Stimuli
Neural interfaces that stimulate the peripheral nerves have the potential to provide sensory feedback from artificial hands. Many neural interfaces are now being developed that allow for multi-channel stimulation of nerves. It is widely accepted that the electric fields generated by two or more contacts on a neural interface can interact. However, this has previously not been examined in the context of sensory feedback prostheses. Here, we aimed to investigate these interactions and the recovery dynamics of the sensory fibers. A multi-channel cuff electrode was implanted on the sciatic nerve of a rat. It comprised four rings (1 mm apart), each containing four circumferentially arranged electrodes. Temporally-patterned pairs of electrical stimuli were delivered through all 120 combinations of electrode pairs. Compound action potentials, elicited by stimulation of the sciatic nerve, were measured with two pairs of hook electrodes placed on the L 4 dorsal root. We find that regardless of the relative position of the two electrodes on the cuff, at an interval of 0 ms, the CAP response is facilitated. At all other intervals, an inter-stimulus interval of even 5 ms was not enough for the response to the second stimulus to fully recover. This observation suggests that overlapping regions of nerve were stimulated. Examining only the intervals where the CAP did not fully recover, we noticed that if the electrodes lay longitudinally, that is, along the nerve, the CAP recovery was significantly impaired, compared to when the electrodes were in any other relative position. The observed space- and time-dependent interactions advocate for further controlled neuroscience studies in parallel to translational work on closed-loop prosthesis control.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2018, 1214-1217
Recovery of the Response of Sensory Fibers to the Second of a Pair of Peripheral Nerve Stimuli
Neural interfaces that stimulate the peripheral nerves have the potential to provide sensory feedback from artificial hands. Many neural interfaces are now being developed that allow for multi-channel stimulation of nerves. It is widely accepted that the electric fields generated by two or more contacts on a neural interface can interact. However, this has previously not been examined in the context of sensory feedback prostheses. Here, we aimed to investigate these interactions and the recovery dynamics of the sensory fibers. A multi-channel cuff electrode was implanted on the sciatic nerve of a rat. It comprised four rings (1 mm apart), each containing four circumferentially arranged electrodes. Temporally-patterned pairs of electrical stimuli were delivered through all 120 combinations of electrode pairs. Compound action potentials, elicited by stimulation of the sciatic nerve, were measured with two pairs of hook electrodes placed on the L 4 dorsal root. We find that regardless of the relative position of the two electrodes on the cuff, at an interval of 0 ms, the CAP response is facilitated. At all other intervals, an inter-stimulus interval of even 5 ms was not enough for the response to the second stimulus to fully recover. This observation suggests that overlapping regions of nerve were stimulated. Examining only the intervals where the CAP did not fully recover, we noticed that if the electrodes lay longitudinally, that is, along the nerve, the CAP recovery was significantly impaired, compared to when the electrodes were in any other relative position. The observed space- and time-dependent interactions advocate for further controlled neuroscience studies in parallel to translational work on closed-loop prosthesis control.
- Open Access
- 9 May 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (4) , 046004
Influence of nerve cuff channel count and implantation site on the separability of afferent ENG
Recording of neural signals from intact peripheral nerves in patients with spinal cord injury or stroke survivors offers the possibility for the development of closed-loop sensorimotor prostheses. Nerve cuffs have been found to provide stable recordings from peripheral nerves for prolonged periods of time. However, questions remain over the design and positioning of nerve cuffs such that the separability of neural data recorded from the peripheral nerves is improved. Afferent electroneurographic (ENG) signals were recorded with nerve cuffs placed on the sciatic nerve of rats in response to various mechanical stimuli to the hindpaw. The mean absolute value of the signal was extracted and input to a classifier. The performance of the classifier was evaluated under two conditions: (1) when information from either a 3- or 16-channel cuff was used; (2) when information was available from a cuff placed either distally or proximally along the nerve. We show that both 3- and 16-channel cuffs were able to separate afferent ENG signals with an accuracy greater than chance. The highest classification scores were achieved when the classifier was fed with information obtained from a 16-channel cuff placed distally. While the 16-channel cuff always outperformed the 3-channel cuff, the difference in performance was increased when the 16-channel cuff was placed distally rather than proximally on the nerve. The results indicate that increasing the complexity of a nerve cuff may only be advantageous if the nerve cuff is to be implanted distally, where the nerve has begun to divide into individual fascicles.
- 9 May 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (4) , 046004
Open AccessInfluence of nerve cuff channel count and implantation site on the separability of afferent ENG
Recording of neural signals from intact peripheral nerves in patients with spinal cord injury or stroke survivors offers the possibility for the development of closed-loop sensorimotor prostheses. Nerve cuffs have been found to provide stable recordings from peripheral nerves for prolonged periods of time. However, questions remain over the design and positioning of nerve cuffs such that the separability of neural data recorded from the peripheral nerves is improved. Afferent electroneurographic (ENG) signals were recorded with nerve cuffs placed on the sciatic nerve of rats in response to various mechanical stimuli to the hindpaw. The mean absolute value of the signal was extracted and input to a classifier. The performance of the classifier was evaluated under two conditions: (1) when information from either a 3- or 16-channel cuff was used; (2) when information was available from a cuff placed either distally or proximally along the nerve. We show that both 3- and 16-channel cuffs were able to separate afferent ENG signals with an accuracy greater than chance. The highest classification scores were achieved when the classifier was fed with information obtained from a 16-channel cuff placed distally. While the 16-channel cuff always outperformed the 3-channel cuff, the difference in performance was increased when the 16-channel cuff was placed distally rather than proximally on the nerve. The results indicate that increasing the complexity of a nerve cuff may only be advantageous if the nerve cuff is to be implanted distally, where the nerve has begun to divide into individual fascicles.
- Open Access
Recovery Dynamics of the High Frequency Alternating Current Nerve Block
Objective: High-Frequency alternating current (HFAC) nerve block has great potential for neuromodulation-based therapies. However nerve function recovery dynamics after a block is highly understudied. This study aims to characterise the recovery dynamics of neural function after an HFAC block. Approach: Experiments were carried out in-vivo to determine blocking efficacy as a function of blocking signal amplitude and frequency, and recovery times as well as recovery completeness was measured within a 0.7 s time scale from the end of block. The sciatic nerve was stimulated at 100 Hz during recovery to reduce error to within ±10 ms for measurements of recovery dynamics. The electromyogram (EMG) signals were measured from gastrocnemius medialis and tibialis anterior during trials as an indicator for nerve function. Main Results: The HFAC block was most reliable around 20 kHz, with block thresholds approximately 5 or 6 mA depending on the animal and muscle. Recovery times ranged from 20 to 430 milliseconds and final values spanned relative outputs from approximately 1 to 0.2. Higher blocking signal frequencies and amplitudes increased recovery time and decreased recovery completeness. Significance: These results confirm that recovery dynamics from block depend on blocking signal frequency and amplitude, which is of particular importance for neuromodulation therapies and for comparing results across studies using different blocking signal parameters.
Open AccessRecovery Dynamics of the High Frequency Alternating Current Nerve Block
Objective: High-Frequency alternating current (HFAC) nerve block has great potential for neuromodulation-based therapies. However nerve function recovery dynamics after a block is highly understudied. This study aims to characterise the recovery dynamics of neural function after an HFAC block. Approach: Experiments were carried out in-vivo to determine blocking efficacy as a function of blocking signal amplitude and frequency, and recovery times as well as recovery completeness was measured within a 0.7 s time scale from the end of block. The sciatic nerve was stimulated at 100 Hz during recovery to reduce error to within ±10 ms for measurements of recovery dynamics. The electromyogram (EMG) signals were measured from gastrocnemius medialis and tibialis anterior during trials as an indicator for nerve function. Main Results: The HFAC block was most reliable around 20 kHz, with block thresholds approximately 5 or 6 mA depending on the animal and muscle. Recovery times ranged from 20 to 430 milliseconds and final values spanned relative outputs from approximately 1 to 0.2. Higher blocking signal frequencies and amplitudes increased recovery time and decreased recovery completeness. Significance: These results confirm that recovery dynamics from block depend on blocking signal frequency and amplitude, which is of particular importance for neuromodulation therapies and for comparing results across studies using different blocking signal parameters.
- Open Access
- 11 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-14
Separability of neural responses to standardised mechanical stimulation of limbs
Considerable scientific and technological efforts are currently being made towards the development of neural prostheses. Understanding how the peripheral nervous system responds to electro-mechanical stimulation of the limb, will help to inform the design of prostheses that can restore function or accelerate recovery from injury to the sensory motor system. However, due to differences in experimental protocols, it is difficult, if not impossible, to make meaningful comparisons between different peripheral nerve interfaces. Therefore, we developed a low-cost electronic system to standardise the mechanical stimulation of a rat’s hindpaw. Three types of mechanical stimulations, namely, proprioception, touch and nociception were delivered to the limb and the electroneurogram signals were recorded simultaneously from the sciatic nerve with a 16-contact cuff electrode. For the first time, results indicate separability of neural responses according to stimulus type as well as intensity. Statistical analysis reveal that cuff contacts placed circumferentially, rather than longitudinally, are more likely to lead to higher classification rates. This flexible setup may be readily adapted for systematic comparison of various electrodes and mechanical stimuli in rodents. Hence, we have made its electro-mechanical design and computer programme available online
- 11 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-14
Open AccessSeparability of neural responses to standardised mechanical stimulation of limbs
Considerable scientific and technological efforts are currently being made towards the development of neural prostheses. Understanding how the peripheral nervous system responds to electro-mechanical stimulation of the limb, will help to inform the design of prostheses that can restore function or accelerate recovery from injury to the sensory motor system. However, due to differences in experimental protocols, it is difficult, if not impossible, to make meaningful comparisons between different peripheral nerve interfaces. Therefore, we developed a low-cost electronic system to standardise the mechanical stimulation of a rat’s hindpaw. Three types of mechanical stimulations, namely, proprioception, touch and nociception were delivered to the limb and the electroneurogram signals were recorded simultaneously from the sciatic nerve with a 16-contact cuff electrode. For the first time, results indicate separability of neural responses according to stimulus type as well as intensity. Statistical analysis reveal that cuff contacts placed circumferentially, rather than longitudinally, are more likely to lead to higher classification rates. This flexible setup may be readily adapted for systematic comparison of various electrodes and mechanical stimuli in rodents. Hence, we have made its electro-mechanical design and computer programme available online
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 391-394
Identification of sensory information in mixed nerves using multi-channel cuff electrodes for closed loop neural prostheses
The addition of sensory feedback is expected to greatly enhance the performance of motor neuroprostheses. In the case of stroke or spinal cord injured patients, sensory information can be obtained from electroneurographic (ENG) signals recorded from intact nerves in the non-functioning limb. Here, we aimed to identify sensory information recorded from mixed nerves using a multi-channel cuff electrode. ENG afferent signals were recorded in response to mechanical stimulation of the foot corresponding to three different functional types of sensory stimuli, namely: nociception, proprioception and touch. Offline digital signal processing was used to extract features for use as inputs for classification. A quadratic support vector machine was used to classify the data and the five fold cross validation error was measured. The results show that classification of nociceptive and proprioceptive stimuli is feasible, with cross validation errors of less than 10%. However, further work is needed to determine whether the touch information can be extracted more reliably from these recordings.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 391-394
Identification of sensory information in mixed nerves using multi-channel cuff electrodes for closed loop neural prostheses
The addition of sensory feedback is expected to greatly enhance the performance of motor neuroprostheses. In the case of stroke or spinal cord injured patients, sensory information can be obtained from electroneurographic (ENG) signals recorded from intact nerves in the non-functioning limb. Here, we aimed to identify sensory information recorded from mixed nerves using a multi-channel cuff electrode. ENG afferent signals were recorded in response to mechanical stimulation of the foot corresponding to three different functional types of sensory stimuli, namely: nociception, proprioception and touch. Offline digital signal processing was used to extract features for use as inputs for classification. A quadratic support vector machine was used to classify the data and the five fold cross validation error was measured. The results show that classification of nociceptive and proprioceptive stimuli is feasible, with cross validation errors of less than 10%. However, further work is needed to determine whether the touch information can be extracted more reliably from these recordings.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 003223-003227
Multichannel cuff electrodes for peripheral nerve stimulation and recording
In the development of neuroprostheses to restore sensory and motor function to disabled patients the choice of the electrodes to be used remains an important consideration. The optimal electrode design should be minimally invasive and be capable of recording or stimulating selectively a large number of nerve fibers. Additionally, the electrodes should be capable of delivering stimulation within electrochemically safe limits. Here we report on the use of a multi-contact cuff electrode for stimulation and recording from peripheral nerves. Nerve cuffs with 16 electrodes, comprising 4 rings of 4 electrodes, were implanted around the sciatic nerve of two rats. The electromyogram signal (EMG) was recorded in response to electrical stimulation delivered by the electrodes, and the electroneurogram signal (ENG) was recorded in response to sensory stimulation applied to the ipsilateral foot. Visually detectable muscle movements were elicited with charge injections ranging from 4.6 to 8.2 nC. ENG recordings in response to sensory stimulus allowed for the onset and culmination of sensory stimulation to be detected using mean absolute value of the signal. Initial results indicate that flexion and extension of the ankle joint can be differentiated by combining information recorded from pairs of electrodes. The results of this study indicate that multi-contact cuffs can be used for decoding neural signals; however, more data needs to be collected for classification of sensory movements to be tested.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 003223-003227
Multichannel cuff electrodes for peripheral nerve stimulation and recording
In the development of neuroprostheses to restore sensory and motor function to disabled patients the choice of the electrodes to be used remains an important consideration. The optimal electrode design should be minimally invasive and be capable of recording or stimulating selectively a large number of nerve fibers. Additionally, the electrodes should be capable of delivering stimulation within electrochemically safe limits. Here we report on the use of a multi-contact cuff electrode for stimulation and recording from peripheral nerves. Nerve cuffs with 16 electrodes, comprising 4 rings of 4 electrodes, were implanted around the sciatic nerve of two rats. The electromyogram signal (EMG) was recorded in response to electrical stimulation delivered by the electrodes, and the electroneurogram signal (ENG) was recorded in response to sensory stimulation applied to the ipsilateral foot. Visually detectable muscle movements were elicited with charge injections ranging from 4.6 to 8.2 nC. ENG recordings in response to sensory stimulus allowed for the onset and culmination of sensory stimulation to be detected using mean absolute value of the signal. Initial results indicate that flexion and extension of the ankle joint can be differentiated by combining information recorded from pairs of electrodes. The results of this study indicate that multi-contact cuffs can be used for decoding neural signals; however, more data needs to be collected for classification of sensory movements to be tested.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 116 (19483546) , 1477-1480
Optimising electrode surface area to minimize power consumption in a cortical penetrating prosthesis
In the design of cortical stimulating prostheses for applications such as vision perception or motor control it is preferable to use wireless power and data transfer to maintain a biological barrier to infection. This puts a constraint on the amount of power that can be supplied to the implant, in turn limiting the power that can be used for stimulation. Design of electrodes for such prostheses have considered factors such as efficiency of stimulation and penetrating capacity; here we consider the design of electrodes from the power consumption perspective. We use the simple electrode geometry of a sphere to determine if the surface area of the electrode can be chosen in order to minimize the power consumed during stimulation. As is known to happen when an electrode is inserted to penetrate into brain tissue, we have assumed that, due to mechanical damage from electrode insertion and the response of brain tissue to the foreign body of an electrode, there will be a kill zone around the electrode where no viable neurons are present. Using realistic thicknesses for the kill zone from the published literature and our own unpublished work, we demonstrate that when the width of the kill zone is known, an electrode's surface area can be chosen so that the power consumed during stimulation is minimized.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 116 (19483546) , 1477-1480
Optimising electrode surface area to minimize power consumption in a cortical penetrating prosthesis
In the design of cortical stimulating prostheses for applications such as vision perception or motor control it is preferable to use wireless power and data transfer to maintain a biological barrier to infection. This puts a constraint on the amount of power that can be supplied to the implant, in turn limiting the power that can be used for stimulation. Design of electrodes for such prostheses have considered factors such as efficiency of stimulation and penetrating capacity; here we consider the design of electrodes from the power consumption perspective. We use the simple electrode geometry of a sphere to determine if the surface area of the electrode can be chosen in order to minimize the power consumed during stimulation. As is known to happen when an electrode is inserted to penetrate into brain tissue, we have assumed that, due to mechanical damage from electrode insertion and the response of brain tissue to the foreign body of an electrode, there will be a kill zone around the electrode where no viable neurons are present. Using realistic thicknesses for the kill zone from the published literature and our own unpublished work, we demonstrate that when the width of the kill zone is known, an electrode's surface area can be chosen so that the power consumed during stimulation is minimized.