Xingjuan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingjuan Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Chunxin Yang
School of Aeronautic Science and Engineering, Beihang University, China
4 shared publicationsChao Wang
School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China
3 shared publicationsHan Yang
School of Aeronautic Science and Engineering, Beihang University, China
3 shared publications- Han Yang
School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China
3 shared publications - Chao Wang
School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China
1 shared publication - Chunxin Yang
School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
Experimental and Simulation Research on Straight-Through Cyclone Water Separator: Effects of Structural and Operational Parameters on Separation Performance
The aircraft air-cycle system (ACS) provides cabin cooling, dehumidification, and pressurization. As a key component, the water separator removes free moisture from the air, preventing turbine icing/blockage under high humidity and avoiding humidity-induced electronics failures, thus ensuring reliable ACS operation. Existing studies focus mainly on oil and chemical applications, with limited work for aircraft ACS. To address this research gap, this study investigates a straight-through cyclone water separator for aircraft ACS applications. We built a test platform to measure separation efficiency and conducted experiments at swirl angles of 20°, 30°, and 40°. A simulation model based on the Reynolds Stress turbulence model and a discrete phase model was established, and its simulation efficiency agreed with experiments within 4.1%. Simulation on water separator under high-pressure and low-pressure conditions were conducted, revealing internal flow fields and droplet dynamics. Results show each swirl angle has a distinct high-efficiency operating range, enabling selection according to system parameters across air mass flow rates; under varying humidification rate, the 40° swirl generator performed best. Simulations further indicate that higher operating pressure markedly improves performance: pressure loss decreased from 4.5 kPa to 0.7 kPa, while separation efficiency increased by 30.7%.
Open AccessExperimental and Simulation Research on Straight-Through Cyclone Water Separator: Effects of Structural and Operational Parameters on Separation Performance
The aircraft air-cycle system (ACS) provides cabin cooling, dehumidification, and pressurization. As a key component, the water separator removes free moisture from the air, preventing turbine icing/blockage under high humidity and avoiding humidity-induced electronics failures, thus ensuring reliable ACS operation. Existing studies focus mainly on oil and chemical applications, with limited work for aircraft ACS. To address this research gap, this study investigates a straight-through cyclone water separator for aircraft ACS applications. We built a test platform to measure separation efficiency and conducted experiments at swirl angles of 20°, 30°, and 40°. A simulation model based on the Reynolds Stress turbulence model and a discrete phase model was established, and its simulation efficiency agreed with experiments within 4.1%. Simulation on water separator under high-pressure and low-pressure conditions were conducted, revealing internal flow fields and droplet dynamics. Results show each swirl angle has a distinct high-efficiency operating range, enabling selection according to system parameters across air mass flow rates; under varying humidification rate, the 40° swirl generator performed best. Simulations further indicate that higher operating pressure markedly improves performance: pressure loss decreased from 4.5 kPa to 0.7 kPa, while separation efficiency increased by 30.7%.
- Open Access
Performance Analysis of an Ejector-Enhanced Heat Pump System for Low-Temperature Waste Heat Recovery Using UHVDC Converter Valves
This article proposes a heating method based on heat pump technology to address the large amount of low-grade waste heat generated by a certain type of ultra-high voltage direct current (UHVDC) converter valve. Thermal performance calculations for two systems, a basic vapor compression heat pump system (BVCHPS) based on thermal expansion valve throttling and an ejector-enhanced heat pump system (EEHPS) are analyzed. The research results show that the EEHPS exhibits superior COP and exergy efficiency when generating hot water above 80 °C using a heat source below 50 °C. Additionally, mathematical modeling analysis identifies optimal structural parameters such as nozzle throat diameter, throat area ratio, and nozzle outlet diameter for the ejector in its design state. The low-temperature waste heat recovered from the UHVDC converter valves can be further used in engineering applications such as heating, refrigeration, seawater desalination, and sewage treatment.
Open AccessPerformance Analysis of an Ejector-Enhanced Heat Pump System for Low-Temperature Waste Heat Recovery Using UHVDC Converter Valves
This article proposes a heating method based on heat pump technology to address the large amount of low-grade waste heat generated by a certain type of ultra-high voltage direct current (UHVDC) converter valve. Thermal performance calculations for two systems, a basic vapor compression heat pump system (BVCHPS) based on thermal expansion valve throttling and an ejector-enhanced heat pump system (EEHPS) are analyzed. The research results show that the EEHPS exhibits superior COP and exergy efficiency when generating hot water above 80 °C using a heat source below 50 °C. Additionally, mathematical modeling analysis identifies optimal structural parameters such as nozzle throat diameter, throat area ratio, and nozzle outlet diameter for the ejector in its design state. The low-temperature waste heat recovered from the UHVDC converter valves can be further used in engineering applications such as heating, refrigeration, seawater desalination, and sewage treatment.
- Open Access
Prediction of the Heat Generation Rate of Lithium-Ion Batteries Based on Three Machine Learning Algorithms
The heat generation rate (HGR) of lithium-ion batteries is crucial for the design of a battery thermal management system. Machine learning algorithms can effectively solve nonlinear problems and have been implemented in the state estimation and life prediction of batteries; however, limited research has been conducted on determining the battery HGR through machine learning. In this study, we employ three common machine learning algorithms, i.e., artificial neural network (ANN), support vector machine (SVM), and Gaussian process regression (GPR), to predict the battery HGR based on our experimental data, along with cases of interpolation and extrapolation. The results indicated the following: (1) the prediction accuracies for the interpolation cases were better than those of extrapolation, and the R2 values of interpolation were greater than 0.96; (2) after the discharge voltage was added as an input parameter, the prediction of the ANN was barely affected, whereas the performance of the SVM and GPR were improved; and (3) the ANN exhibited the best performance among the three algorithms. Accurate results can be obtained by using a single hidden layer and no more than 15 neurons without the additional input, where the R2 values were in the range of 0.89–1.00. Therefore, the ANN is preferable for predicting the HGR of lithium-ion batteries.
Open AccessPrediction of the Heat Generation Rate of Lithium-Ion Batteries Based on Three Machine Learning Algorithms
The heat generation rate (HGR) of lithium-ion batteries is crucial for the design of a battery thermal management system. Machine learning algorithms can effectively solve nonlinear problems and have been implemented in the state estimation and life prediction of batteries; however, limited research has been conducted on determining the battery HGR through machine learning. In this study, we employ three common machine learning algorithms, i.e., artificial neural network (ANN), support vector machine (SVM), and Gaussian process regression (GPR), to predict the battery HGR based on our experimental data, along with cases of interpolation and extrapolation. The results indicated the following: (1) the prediction accuracies for the interpolation cases were better than those of extrapolation, and the R2 values of interpolation were greater than 0.96; (2) after the discharge voltage was added as an input parameter, the prediction of the ANN was barely affected, whereas the performance of the SVM and GPR were improved; and (3) the ANN exhibited the best performance among the three algorithms. Accurate results can be obtained by using a single hidden layer and no more than 15 neurons without the additional input, where the R2 values were in the range of 0.89–1.00. Therefore, the ANN is preferable for predicting the HGR of lithium-ion batteries.
- Open Access
Influences of Different Architectures on the Thermodynamic Performance and Network Structure of Aircraft Environmental Control System
The environmental control system (ECS) is one of the most important systems in the aircraft used to regulate the pressure, temperature and humidity of the air in the cabin. This study investigates the influences of different architectures on the thermal performance and network structure of ECS. The refrigeration and pressurization performances of ECS with four different architectures are analyzed and compared by the endoreversible thermodynamic analysis method, and their external and internal responses have also been discussed. The results show that the connection modes of the heat exchanger have minor effects on the performance of ECSs, but the influence of the air cycle machine is obvious. This study attempts to abstract the ECS as a network structure based on the graph theory, and use entropy in information theory for quantitative evaluation. The results provide a theoretical basis for the design of ECS and facilitate engineers to make reliable decisions.
Open AccessInfluences of Different Architectures on the Thermodynamic Performance and Network Structure of Aircraft Environmental Control System
The environmental control system (ECS) is one of the most important systems in the aircraft used to regulate the pressure, temperature and humidity of the air in the cabin. This study investigates the influences of different architectures on the thermal performance and network structure of ECS. The refrigeration and pressurization performances of ECS with four different architectures are analyzed and compared by the endoreversible thermodynamic analysis method, and their external and internal responses have also been discussed. The results show that the connection modes of the heat exchanger have minor effects on the performance of ECSs, but the influence of the air cycle machine is obvious. This study attempts to abstract the ECS as a network structure based on the graph theory, and use entropy in information theory for quantitative evaluation. The results provide a theoretical basis for the design of ECS and facilitate engineers to make reliable decisions.
- 1 January 2018
- Published by INSTICC
- p. 87-91
Research on the Environmental Control System of the Equipment Bay for A High Altitude Long Endurance Solar-powered UAV
Substantial efforts have been focused on developing high altitude long endurance solar-powered unmanned aerial vehicles (LESP UAVs). With increasingly integrated and compact electronic equipment, the demand for effective heat dissipation becomes more critical but challenging. Aiming at LESP UAV’s equipment bay with the cooling capacity demand of 5kW, after the availability of heat sink is analysed, a single-stage and two-stage vapor compression refrigeration cycle based on radiation cooling are proposed. By using thermodynamic analysis and quality estimation, the corresponding quantitative relationship is obtained, and the variation between cooling capacity and power consumption/system weight are calculated. Combined with the engineering application, the suitable conditions of two schemes are given. The results can provide theoretical and engineering guidance for the research in this field, and have good engineering application value.
- 1 January 2018
- Published by INSTICC
- p. 87-91
Research on the Environmental Control System of the Equipment Bay for A High Altitude Long Endurance Solar-powered UAV
Substantial efforts have been focused on developing high altitude long endurance solar-powered unmanned aerial vehicles (LESP UAVs). With increasingly integrated and compact electronic equipment, the demand for effective heat dissipation becomes more critical but challenging. Aiming at LESP UAV’s equipment bay with the cooling capacity demand of 5kW, after the availability of heat sink is analysed, a single-stage and two-stage vapor compression refrigeration cycle based on radiation cooling are proposed. By using thermodynamic analysis and quality estimation, the corresponding quantitative relationship is obtained, and the variation between cooling capacity and power consumption/system weight are calculated. Combined with the engineering application, the suitable conditions of two schemes are given. The results can provide theoretical and engineering guidance for the research in this field, and have good engineering application value.
- Open Access
- 7 October 2015
- Published by Elsevier in Procedia Engineering
- Vol. 121, 325-332
Study on Ground-Test Simulation Method of the Ram Air for Commercial Airliners’ Environmental Control System
- 7 October 2015
- Published by Elsevier in Procedia Engineering
- Vol. 121, 325-332
Open AccessStudy on Ground-Test Simulation Method of the Ram Air for Commercial Airliners’ Environmental Control System
- Open Access
- 7 October 2015
- Published by Elsevier in Procedia Engineering
- Vol. 121, 248-255
Design Analysis of Power Recovery Systems for Cabin Exhaust Air
- 7 October 2015
- Published by Elsevier in Procedia Engineering
- Vol. 121, 248-255
Open AccessDesign Analysis of Power Recovery Systems for Cabin Exhaust Air
- 8 July 2012
- Published by ASME International
- p. 475-479
Analysis on Air-Side Characteristics of the Condenser at Low Ambient Pressure Conditions
The vapor cycle refrigeration system is used in aircraft cooling. The changes of the ambient air properties will affect the condenser performance of the vapor cycle refrigeration system. The air-side characteristics between the flow and pressure drop at low pressure conditions must be taken into account, especially when it is used in the aircraft. Through the three tests of the condenser fan, the condenser, and the condenser module, the common property model of the air-side flow and pressure head/drop for each part is established and experimentally verified. The results show that the flow and pressure head or drop relationship of each unit under different pressures of 101.3kPa, 79.5kPa, 61.7kPa, and 47.2kPa is simply deduced by means of the ground test. From this study, the operation points of the condenser module under low ambient pressure conditions can be derived as well.
- 8 July 2012
- Published by ASME International
- p. 475-479
Analysis on Air-Side Characteristics of the Condenser at Low Ambient Pressure Conditions
The vapor cycle refrigeration system is used in aircraft cooling. The changes of the ambient air properties will affect the condenser performance of the vapor cycle refrigeration system. The air-side characteristics between the flow and pressure drop at low pressure conditions must be taken into account, especially when it is used in the aircraft. Through the three tests of the condenser fan, the condenser, and the condenser module, the common property model of the air-side flow and pressure head/drop for each part is established and experimentally verified. The results show that the flow and pressure head or drop relationship of each unit under different pressures of 101.3kPa, 79.5kPa, 61.7kPa, and 47.2kPa is simply deduced by means of the ground test. From this study, the operation points of the condenser module under low ambient pressure conditions can be derived as well.