Philipp Diersing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Philipp Diersing has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Southan
Institute of Interfacial Process Engineering and Plasma Technology IGVP University of Stuttgart Nobelstr. 12 70569 Stuttgart Germany
1 shared publication - Benjamin Riegger
Institute of Interfacial Process Engineering and Plasma Technology (IGVP), University of Stuttgart, 70569 Stuttgart, Germany
1 shared publication - Lotte Rathgeber
Institute of Electrical and Optical Communications Engineering (INT), University of Stuttgart, 70569 Stuttgart, Germany
1 shared publication - Manfred Berroth
Institute of Electrical and Optical Communications Engineering (INT), University of Stuttgart, 70569 Stuttgart, Germany
1 shared publication - Niklas Hoppe
University of Stuttgart, Institute for Electrical and Optical Communications Engineering, Stuttgart, Germany
1 shared publication - Pascal Scheck
Institute of Electrical and Optical Communications Engineering (INT), University of Stuttgart, 70569 Stuttgart, Germany
1 shared publication
Latest Publications
- Open Access
- 14 September 2017
- Published by MDPI AG in Biosensors
- Vol. 7 (3) , 37
Silicon Integrated Dual-Mode Interferometer with Differential Outputs
The dual-mode interferometer (DMI) is an attractive alternative to Mach-Zehnder interferometers for sensor purposes, achieving sensitivities to refractive index changes close to state-of-the-art. Modern designs on silicon-on-insulator (SOI) platforms offer thermally stable and compact devices with insertion losses of less than 1 dB and high extinction ratios. Compact arrays of multiple DMIs in parallel are easy to fabricate due to the simple structure of the DMI. In this work, the principle of operation of an integrated DMI with differential outputs is presented which allows the unambiguous phase shift detection with a single wavelength measurement, rather than using a wavelength sweep and evaluating the optical output power spectrum. Fluctuating optical input power or varying attenuation due to different analyte concentrations can be compensated by observing the sum of the optical powers at the differential outputs. DMIs with two differential single-mode outputs are fabricated in a 250 nm SOI platform, and corresponding measurements are shown to explain the principle of operation in detail. A comparison of DMIs with the conventional Mach-Zehnder interferometer using the same technology concludes this work.
- 14 September 2017
- Published by MDPI AG in Biosensors
- Vol. 7 (3) , 37
Open AccessSilicon Integrated Dual-Mode Interferometer with Differential Outputs
The dual-mode interferometer (DMI) is an attractive alternative to Mach-Zehnder interferometers for sensor purposes, achieving sensitivities to refractive index changes close to state-of-the-art. Modern designs on silicon-on-insulator (SOI) platforms offer thermally stable and compact devices with insertion losses of less than 1 dB and high extinction ratios. Compact arrays of multiple DMIs in parallel are easy to fabricate due to the simple structure of the DMI. In this work, the principle of operation of an integrated DMI with differential outputs is presented which allows the unambiguous phase shift detection with a single wavelength measurement, rather than using a wavelength sweep and evaluating the optical output power spectrum. Fluctuating optical input power or varying attenuation due to different analyte concentrations can be compensated by observing the sum of the optical powers at the differential outputs. DMIs with two differential single-mode outputs are fabricated in a 250 nm SOI platform, and corresponding measurements are shown to explain the principle of operation in detail. A comparison of DMIs with the conventional Mach-Zehnder interferometer using the same technology concludes this work.