Sergo Sagareli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sergo Sagareli has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Bosworth
Center for Advanced Power Systems, Florida State University, Tallahassee, FL, USA
2 shared publications A. Zorn
DiGioia Gray and Associates, Monroeville, PA, USA
1 shared publication- Andrew V. Zorn
Digioia Gray & Associates, Pittsburgh United States
1 shared publication D. Birrell
Windsor Bush Consulting, Adams, MA
1 shared publication- David Birrell
Windsor Bush Consulting, Adams, Massachusetts United States
1 shared publication E. Tahmasebi
Center for Advanced Technology for Large Structural System, Lehigh University, Bethlehem, PA, USA
1 shared publication
Latest Publications
- 3 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (5) , 2097-2105
Testing and Analysis of Dynamic Response of a High-Voltage Substation Structure to Short-Circuit Current Forces
In substations, buswork, insulators, and supporting structures are subjected to electromagnetic forces caused by short-circuits. The current industry design standard of practice is to apply the maximum instantaneous short-circuit force to the structure and perform simple static structural analysis to calculate supporting structure members. However, it is well known that this may be overly conservative since the applied forces and the response of the structure is dynamic in nature. To quantify the dynamic effects, full-scale short-circuit testing was performed on a typical 138 kV disconnect switch stand. The switch stand was instrumented with fiber optic strain gauges and subjected to a variety of fault conditions. Extensive dynamic finite element analyses were performed on the subject structure which were validated with the test data. The results confirm the reduced dynamic response of the structure. With further analyses it is anticipated that a generalized quasi-static design methodology that considers dynamic response can be developed to replace the present short-circuit design approach.
- 3 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (5) , 2097-2105
Testing and Analysis of Dynamic Response of a High-Voltage Substation Structure to Short-Circuit Current Forces
In substations, buswork, insulators, and supporting structures are subjected to electromagnetic forces caused by short-circuits. The current industry design standard of practice is to apply the maximum instantaneous short-circuit force to the structure and perform simple static structural analysis to calculate supporting structure members. However, it is well known that this may be overly conservative since the applied forces and the response of the structure is dynamic in nature. To quantify the dynamic effects, full-scale short-circuit testing was performed on a typical 138 kV disconnect switch stand. The switch stand was instrumented with fiber optic strain gauges and subjected to a variety of fault conditions. Extensive dynamic finite element analyses were performed on the subject structure which were validated with the test data. The results confirm the reduced dynamic response of the structure. With further analyses it is anticipated that a generalized quasi-static design methodology that considers dynamic response can be developed to replace the present short-circuit design approach.
- 18 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (4) , 1510-1517
Modeling of Reaction Forces in High-Voltage Substation Structures
When designing utility substations, it is necessary to consider all directional components of the electromagnetic reaction forces during short-circuit faults to properly account for their effects on substation equipment. IEEE 605 assumes straight long parallel conductors in its two-dimensional (2-D) force calculations while ignoring any bends and 3-D placement of conductors. CIGRE's Brochure 105 provides practical information on the mechanical effects of short-circuit currents in HV and EHV open air, conventional substations. Although these computational methods are easy to implement, they have several limitations and are sometimes too conservative. Previously published papers address such conservatism using dynamic analysis approaches that provide more accurate results when compared to experimental data. This paper provides two extensions to IEEE 605 and CIGRE 105 for calculating fault current reaction forces. A closed-form equation defining the simplified 2-D short-circuit force time history during a fault based on CIGRE 105 and a computationally inexpensive numerical 3-D force calculation technique are presented.
- 18 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (4) , 1510-1517
Modeling of Reaction Forces in High-Voltage Substation Structures
When designing utility substations, it is necessary to consider all directional components of the electromagnetic reaction forces during short-circuit faults to properly account for their effects on substation equipment. IEEE 605 assumes straight long parallel conductors in its two-dimensional (2-D) force calculations while ignoring any bends and 3-D placement of conductors. CIGRE's Brochure 105 provides practical information on the mechanical effects of short-circuit currents in HV and EHV open air, conventional substations. Although these computational methods are easy to implement, they have several limitations and are sometimes too conservative. Previously published papers address such conservatism using dynamic analysis approaches that provide more accurate results when compared to experimental data. This paper provides two extensions to IEEE 605 and CIGRE 105 for calculating fault current reaction forces. A closed-form equation defining the simplified 2-D short-circuit force time history during a fault based on CIGRE 105 and a computationally inexpensive numerical 3-D force calculation technique are presented.
- 1 January 2004
- Published by ASME International
- p. 141-146
Implementation of New Technologies in Traction Power Systems
Due to significant developments in power electronics since the 1980’s, a row of new components are being used for both utility [1] and traction power substations, leading to new concepts in their design and construction. Among others, such innovations as incorporation of microprocessor-based multifunction protective relays and programmable logic controllers are changing traditional substations’ equipment layout and inter-connections; the development and experimental use of thyristor rectifiers and solid-state DC circuit breakers is under way. A significant reduction in the amount of protective and control devices (and associated wiring) has been achieved by introduction of multi-function relays (MFR or MPR – Multi-Purpose Relay), capable of replacing a whole group of relays used for equipment protection and automated control; for example, one MFR may perform functions of overcurrent and ground fault protection, over- and undervoltage protection, fault sensing and reclosing. Plus, it may be used for data logging and data recording purposes [2]. Additionally, high end MPRs have remote access features allowing not only to set any parameters, but even provide firmware upgrade without visiting the substation, thus providing labor savings. Therefore, one MFR may replace about a dozen of traditional relays and devices, along with their wiring and save maintenance expenses as well. Thyristor Controlled Rectifiers (TCR’s) are another significant innovation in traditional DC traction power substation design. Thyristor rectifiers are offering very important benefit of regulated DC voltage: at the substation’s bus output, the voltage may be constant from 0 to a 100% or even 150% load, which means improved train performance in terms of speed and reliability, as well as lower losses of energy in third rails, and possibility of raising third rail system voltage in the future, thus further lowering losses of energy in the system. Alternatively, it allows to increase the distance between the substations and thus reduce total number of substations. LIRR installed one thyristor rectifier for experimental use in 2003. Flywheel-based energy storage system is another important innovation that is being installed by the LIRR for experimental use. LIRR is installing for experimental use trackside fly-wheel energy storage system developed and tested by the British uranium enrichment company URENCO. According to Tarrant [3], in March 2002 the company successfully tested the KESS – Kinetic Energy Storage System and demonstrated 11% to 18% energy savings in different conditions of operation, because of the lower losses due to higher voltage during the acceleration period.
- 1 January 2004
- Published by ASME International
- p. 141-146
Implementation of New Technologies in Traction Power Systems
Due to significant developments in power electronics since the 1980’s, a row of new components are being used for both utility [1] and traction power substations, leading to new concepts in their design and construction. Among others, such innovations as incorporation of microprocessor-based multifunction protective relays and programmable logic controllers are changing traditional substations’ equipment layout and inter-connections; the development and experimental use of thyristor rectifiers and solid-state DC circuit breakers is under way. A significant reduction in the amount of protective and control devices (and associated wiring) has been achieved by introduction of multi-function relays (MFR or MPR – Multi-Purpose Relay), capable of replacing a whole group of relays used for equipment protection and automated control; for example, one MFR may perform functions of overcurrent and ground fault protection, over- and undervoltage protection, fault sensing and reclosing. Plus, it may be used for data logging and data recording purposes [2]. Additionally, high end MPRs have remote access features allowing not only to set any parameters, but even provide firmware upgrade without visiting the substation, thus providing labor savings. Therefore, one MFR may replace about a dozen of traditional relays and devices, along with their wiring and save maintenance expenses as well. Thyristor Controlled Rectifiers (TCR’s) are another significant innovation in traditional DC traction power substation design. Thyristor rectifiers are offering very important benefit of regulated DC voltage: at the substation’s bus output, the voltage may be constant from 0 to a 100% or even 150% load, which means improved train performance in terms of speed and reliability, as well as lower losses of energy in third rails, and possibility of raising third rail system voltage in the future, thus further lowering losses of energy in the system. Alternatively, it allows to increase the distance between the substations and thus reduce total number of substations. LIRR installed one thyristor rectifier for experimental use in 2003. Flywheel-based energy storage system is another important innovation that is being installed by the LIRR for experimental use. LIRR is installing for experimental use trackside fly-wheel energy storage system developed and tested by the British uranium enrichment company URENCO. According to Tarrant [3], in March 2002 the company successfully tested the KESS – Kinetic Energy Storage System and demonstrated 11% to 18% energy savings in different conditions of operation, because of the lower losses due to higher voltage during the acceleration period.