Qingqing Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qingqing Hu has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Jun Yang
Interdisciplinary Center for Quantum Information, National University of Defense Technology, Changsha, 410073, China
6 shared publicationsAiai Jia
4 shared publicationsChunhua Wei
4 shared publicationsYukun Luo
3 shared publications- Achim Peters
Institut für Physik, Humboldt-Universität zu Berlin, Berlin, Germany
2 shared publications Ai-Ai Jia
Natl Univ Def Technol, Coll Mechatron Engn & Automat, Changsha 410073, Hunan, Peoples R China
2 shared publications
Latest Publications
- Open Access
- 21 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5379
Research on Subsurface Damage Measurement of Fused Silica in Ultra-Precision Grinding Based on Laser Damage Performance
In order to achieve accurate prediction of subsurface damage (SSD) in ultra-precision grinding of high-performance ultra-violet laser-irradiated fused silica optics, the paper combines damage precursor multimodal measurement technology with magnetorheological finishing spot method detection. Various methods such as photothermal weak absorption and fluorescence confocal imaging are used for measuring the surface roughness and subsurface damage depth of a series of fused silica samples prepared under different ultra-precision grinding parameters. The correlation between surface roughness and subsurface damage depth in ultra-precision grinding based on laser damage performance is established using curve fitting. The results indicate that there is a metamorphic layer below the subsurface crack layer, which can cause additional photothermal absorption. Subsurface damage is constituted of the subsurface crack layer and metamorphic layer. Under ultra-precision grinding conditions, the maximum depth of subsurface damage is generally 2.00–4.22 times the depth of the subsurface damage cluster. The roughness Ra and the subsurface damage cluster depth correspond to SSD(cluster) = 195 × Ra − 0.13. The maximum depth of subsurface damage can be predicted by measuring the Ra value, by which accurate prediction of defect depth in ultra-precision grinding and guiding the high-performance manufacturing of ultra-violet laser-irradiated fused silica optics can be achieved.
- 21 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5379
Open AccessResearch on Subsurface Damage Measurement of Fused Silica in Ultra-Precision Grinding Based on Laser Damage Performance
In order to achieve accurate prediction of subsurface damage (SSD) in ultra-precision grinding of high-performance ultra-violet laser-irradiated fused silica optics, the paper combines damage precursor multimodal measurement technology with magnetorheological finishing spot method detection. Various methods such as photothermal weak absorption and fluorescence confocal imaging are used for measuring the surface roughness and subsurface damage depth of a series of fused silica samples prepared under different ultra-precision grinding parameters. The correlation between surface roughness and subsurface damage depth in ultra-precision grinding based on laser damage performance is established using curve fitting. The results indicate that there is a metamorphic layer below the subsurface crack layer, which can cause additional photothermal absorption. Subsurface damage is constituted of the subsurface crack layer and metamorphic layer. Under ultra-precision grinding conditions, the maximum depth of subsurface damage is generally 2.00–4.22 times the depth of the subsurface damage cluster. The roughness Ra and the subsurface damage cluster depth correspond to SSD(cluster) = 195 × Ra − 0.13. The maximum depth of subsurface damage can be predicted by measuring the Ra value, by which accurate prediction of defect depth in ultra-precision grinding and guiding the high-performance manufacturing of ultra-violet laser-irradiated fused silica optics can be achieved.
- 12 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (2) , 1433-1443
Reanalyzing Atomic Beam Interferometric Gyroscopes: Dependence of Sensitivity on Experimental Parameters
As an important technique for developing high-precision gyroscopes, atom interferometry with continuous atomic beams has exhibited advantages of high short-term sensitivity and dynamic response relative to that with periodically launched atom clouds. This paper reanalyzes the characteristics of an atomic beam interferometric gyroscope from perspectives including the continuous operation mode and the modified sensitivity dependence on laser and atomic sources. Specific requirements on certain experimental parameters are explored including the Raman beam diameter, detection beam diameter, atomic flux, laser power, laser phase noise, atomic longitudinal and transverse velocity distributions. The parameter determining strategy is discussed to achieve target sensitivity with controlled conditions such as system volume and operating bandwidth. The results would provide strong support on analytical method and data reference for further improvement of atomic beam interferometric gyroscopes.
- 12 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (2) , 1433-1443
Reanalyzing Atomic Beam Interferometric Gyroscopes: Dependence of Sensitivity on Experimental Parameters
As an important technique for developing high-precision gyroscopes, atom interferometry with continuous atomic beams has exhibited advantages of high short-term sensitivity and dynamic response relative to that with periodically launched atom clouds. This paper reanalyzes the characteristics of an atomic beam interferometric gyroscope from perspectives including the continuous operation mode and the modified sensitivity dependence on laser and atomic sources. Specific requirements on certain experimental parameters are explored including the Raman beam diameter, detection beam diameter, atomic flux, laser power, laser phase noise, atomic longitudinal and transverse velocity distributions. The parameter determining strategy is discussed to achieve target sensitivity with controlled conditions such as system volume and operating bandwidth. The results would provide strong support on analytical method and data reference for further improvement of atomic beam interferometric gyroscopes.
- 12 April 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (7) , 070601
Michelson laser interferometer-based vibration noise contribution measurement method for cold atom interferometry gravimeter*
The measurement performance of the atom interferometry absolute gravimeter is strongly affected by the ground vibration noise. We propose a vibration noise evaluation scheme using a Michelson laser interferometer constructed by the intrinsic Raman laser of the atomic gravimeter. Theoretical analysis shows that the vibration phase measurement accuracy is better than 4 mrad, which corresponds to about 10−10 g accuracy for a single shot gravity measurement. Compared with the commercial seismometer or accelerometer, this method is a simple, low cost, direct, and fully synchronized measurement of the vibration phase which should benefit the development of the atomic gravimeter. On the other side, limited by equivalence principle, the result of the laser interferometer is not absolute but relative vibration measurement. Triangular cap method could be used to evaluation the noise contribution of vibration, which is a different method from others and should benefit the development of the atomic gravimeter.
- 12 April 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (7) , 070601
Michelson laser interferometer-based vibration noise contribution measurement method for cold atom interferometry gravimeter*
The measurement performance of the atom interferometry absolute gravimeter is strongly affected by the ground vibration noise. We propose a vibration noise evaluation scheme using a Michelson laser interferometer constructed by the intrinsic Raman laser of the atomic gravimeter. Theoretical analysis shows that the vibration phase measurement accuracy is better than 4 mrad, which corresponds to about 10−10 g accuracy for a single shot gravity measurement. Compared with the commercial seismometer or accelerometer, this method is a simple, low cost, direct, and fully synchronized measurement of the vibration phase which should benefit the development of the atomic gravimeter. On the other side, limited by equivalence principle, the result of the laser interferometer is not absolute but relative vibration measurement. Triangular cap method could be used to evaluation the noise contribution of vibration, which is a different method from others and should benefit the development of the atomic gravimeter.
- 14 January 2020
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 51 (4) , 660-668
Measurement of the polarization‐ and orientation‐dependent scalar, vector, and tensor light shifts in 87Rb using the near‐resonant, stimulated Raman spectroscopy
We present the polarization‐ and orientation‐dependent characteristics of the differential light shifts (DLSs) in 87Rb using the near‐resonant, stimulated Raman spectroscopy with an atomic fountain clock. Simulation and experimental results demonstrate that the Raman resonant frequencies would shift sinusoidally as the rotation of the laser's polarization vector due to the polarization‐dependent vector and tensor DLSs, and the total DLS is counteracted in some elliptically polarized laser configurations. What is more, this paper provides an alternative method to measure the effective magnetic field vector and the absolute scalar, vector, and tensor (SVT) DLSs and to verify the theoretically calculated SVT dynamical polarizabilities. These results will facilitate the evaluation and elimination of the light shift‐related systemic errors in the atomic optics‐based quantum sensors, including the atomic magnetometer, atomic interferometer, atomic clock, and quantum register.
- 14 January 2020
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 51 (4) , 660-668
Measurement of the polarization‐ and orientation‐dependent scalar, vector, and tensor light shifts in 87Rb using the near‐resonant, stimulated Raman spectroscopy
We present the polarization‐ and orientation‐dependent characteristics of the differential light shifts (DLSs) in 87Rb using the near‐resonant, stimulated Raman spectroscopy with an atomic fountain clock. Simulation and experimental results demonstrate that the Raman resonant frequencies would shift sinusoidally as the rotation of the laser's polarization vector due to the polarization‐dependent vector and tensor DLSs, and the total DLS is counteracted in some elliptically polarized laser configurations. What is more, this paper provides an alternative method to measure the effective magnetic field vector and the absolute scalar, vector, and tensor (SVT) DLSs and to verify the theoretically calculated SVT dynamical polarizabilities. These results will facilitate the evaluation and elimination of the light shift‐related systemic errors in the atomic optics‐based quantum sensors, including the atomic magnetometer, atomic interferometer, atomic clock, and quantum register.
- 29 January 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 97 (1) , 013424
Observation of vector and tensor light shifts in using near-resonant, stimulated Raman spectroscopyWe present the derivation of the frequency-dependent scalar, vector, and tensor dynamical polarizabilities for the two hyperfine levels of the atom ground state. Based on the characterization of the dynamical polarizabilities, we analyze and measure the differential vector and tensor light shift between the ground-state sublevels with near-resonant, stimulated Raman transitions. These results clarify that the tensor polarizabilities for the ground states of alkali atoms are absent when the light field is far detuned from the atomic resonance and the total electronic angular momentum is a good quantum number. In the near-resonant case, the light shifts are nontrivial and the determination of the frequency-dependent vector and tensor dynamic polarizabilities will help to achieve higher fidelities for applications of neutral atoms in quantum information and precision measurements.- 29 January 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 97 (1) , 013424
Observation of vector and tensor light shifts in using near-resonant, stimulated Raman spectroscopyWe present the derivation of the frequency-dependent scalar, vector, and tensor dynamical polarizabilities for the two hyperfine levels of the atom ground state. Based on the characterization of the dynamical polarizabilities, we analyze and measure the differential vector and tensor light shift between the ground-state sublevels with near-resonant, stimulated Raman transitions. These results clarify that the tensor polarizabilities for the ground states of alkali atoms are absent when the light field is far detuned from the atomic resonance and the total electronic angular momentum is a good quantum number. In the near-resonant case, the light shifts are nontrivial and the determination of the frequency-dependent vector and tensor dynamic polarizabilities will help to achieve higher fidelities for applications of neutral atoms in quantum information and precision measurements.- 20 September 2017
- Published by American Physical Society (APS) in Physical Review A
- Vol. 96 (3) , 033414
Mapping the absolute magnetic field and evaluating the quadratic Zeeman-effect-induced systematic error in an atom interferometer gravimeter
Precisely evaluating the systematic error induced by the quadratic Zeeman effect is important for developing atom interferometer gravimeters aiming at an accuracy in the regime (). This paper reports on the experimental investigation of Raman spectroscopy-based magnetic field measurements and the evaluation of the systematic error in the gravimetric atom interferometer (GAIN) due to quadratic Zeeman effect. We discuss Raman duration and frequency step-size-dependent magnetic field measurement uncertainty, present vector light shift and tensor light shift induced magnetic field measurement offset, and map the absolute magnetic field inside the interferometer chamber of GAIN with an uncertainty of 0.72 nT and a spatial resolution of 12.8 mm. We evaluate the quadratic Zeeman-effect-induced gravity measurement error in GAIN as . The methods shown in this paper are important for precisely mapping the absolute magnetic field in vacuum and reducing the quadratic Zeeman-effect-induced systematic error in Raman transition-based precision measurements, such as atomic interferometer gravimeters.- 20 September 2017
- Published by American Physical Society (APS) in Physical Review A
- Vol. 96 (3) , 033414
Mapping the absolute magnetic field and evaluating the quadratic Zeeman-effect-induced systematic error in an atom interferometer gravimeter
Precisely evaluating the systematic error induced by the quadratic Zeeman effect is important for developing atom interferometer gravimeters aiming at an accuracy in the regime (). This paper reports on the experimental investigation of Raman spectroscopy-based magnetic field measurements and the evaluation of the systematic error in the gravimetric atom interferometer (GAIN) due to quadratic Zeeman effect. We discuss Raman duration and frequency step-size-dependent magnetic field measurement uncertainty, present vector light shift and tensor light shift induced magnetic field measurement offset, and map the absolute magnetic field inside the interferometer chamber of GAIN with an uncertainty of 0.72 nT and a spatial resolution of 12.8 mm. We evaluate the quadratic Zeeman-effect-induced gravity measurement error in GAIN as . The methods shown in this paper are important for precisely mapping the absolute magnetic field in vacuum and reducing the quadratic Zeeman-effect-induced systematic error in Raman transition-based precision measurements, such as atomic interferometer gravimeters.- 1 May 2017
- Published by Elsevier in Optics Communications
- Vol. 390, 111-116
Scheme for suppressing atom expansion induced contrast loss in atom interferometers
- 1 May 2017
- Published by Elsevier in Optics Communications
- Vol. 390, 111-116
Scheme for suppressing atom expansion induced contrast loss in atom interferometers
- 15 December 2016
- Published by Springer Nature in The European Physical Journal D
- Vol. 70 (12) , 262
Contrast enhancement via shaped Raman pulses for thermal cold atom cloud interferometry
- 15 December 2016
- Published by Springer Nature in The European Physical Journal D
- Vol. 70 (12) , 262
Contrast enhancement via shaped Raman pulses for thermal cold atom cloud interferometry
- 1 January 2016
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 14 (5) , 51403
Compact phase-lock loop for external cavity diode lasers
We present a compact, low-noise, and inexpensive optical phase-lock loop (OPLL) system to synchronize the frequency and the phase between two external cavity diode lasers. Based on a direct digital synthesizer technique, a programmable radio-frequency generator is implemented as the reference signal source. The OPLL has a narrow beat note linewidth below 1 Hz and a residual mean-square phase error of 0.06 rad2 in a 10 MHz integration bandwidth. The experimental test results prove the competent performance of the system, which is promising as a low-budget choice in atomic physics applications.
- 1 January 2016
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 14 (5) , 51403
Compact phase-lock loop for external cavity diode lasers
We present a compact, low-noise, and inexpensive optical phase-lock loop (OPLL) system to synchronize the frequency and the phase between two external cavity diode lasers. Based on a direct digital synthesizer technique, a programmable radio-frequency generator is implemented as the reference signal source. The OPLL has a narrow beat note linewidth below 1 Hz and a residual mean-square phase error of 0.06 rad2 in a 10 MHz integration bandwidth. The experimental test results prove the competent performance of the system, which is promising as a low-budget choice in atomic physics applications.