Jean-Luc Veyrune
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jean-Luc Veyrune has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Emmanuel Nicolas
Université Clermont Auvergne, CROC, and CHU Clermont‐Ferrand, Service d'Odontologie Clermont‐Ferrand France
5 shared publications - Cindy Batisse
Universite Clermont Auvergne CROC Clermont‐Ferrand France
3 shared publications - Marion Bessadet
Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, F-63000 Clermont-Ferrand, France
3 shared publications - Emmanuel Nicolas
CHU Clermont-Ferrand, Service d'Odontologie, Hôtel-Dieu, F-63000 Clermont-Ferrand, France
2 shared publications - Guillaume Bonnet
Université Clermont Auvergne, CROC, F-63000, Clermont-Ferrand, France
2 shared publications - Marion Bessadet
Clermont Université, Université d'Auvergne, EA4847, CROC, BP 10448, 63000 Clermont-Ferrand, France ; CHU Clermont-Ferrand, Service d'Odontologie, 63003 Clermont-Ferrand, France
2 shared publications
Latest Publications
- Open Access
- 15 May 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (5) , 832
Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
Both conventional and digital impressions aim to record the spatial position of implants in the dental arches. However, there is still a lack of data to justify the use of intraoral scanning over conventional impressions for full-arch implant-supported prostheses. The objective of the in vitro study was to compare the trueness and precision of conventional and digital impressions obtained with four intra-oral scanners: Trios 4 from 3Shape®, Primescan from Dentsply Sirona®, CS3600 from Carestream® and i500 from Medit®. This study focused on the impression of an edentulous maxilla in which five implants were placed for implant-supported complete prosthesis. The digital models were superimposed on a digital reference model using dimensional control and metrology software. Angular and distance deviations from the digital reference model were calculated to assess trueness. Dispersion of the values around their mean for each impression was also calculated for precision. The mean distance deviation in absolute value and the direction of the distance deviation were smaller for conventional impressions (p-value < 0.001). The I-500 had the best results regarding angular measurements, followed by Trios 4 and CS3600 (p < 0.001). The conventional and I-500 digital impressions showed the lowest dispersion of values around the mean (p-value < 0.001). Within the limitations of our study, our results revealed that the conventional impression was more accurate than the digital impression, but further clinical studies are needed to confirm these findings.
- 15 May 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (5) , 832
Open AccessAccuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
Both conventional and digital impressions aim to record the spatial position of implants in the dental arches. However, there is still a lack of data to justify the use of intraoral scanning over conventional impressions for full-arch implant-supported prostheses. The objective of the in vitro study was to compare the trueness and precision of conventional and digital impressions obtained with four intra-oral scanners: Trios 4 from 3Shape®, Primescan from Dentsply Sirona®, CS3600 from Carestream® and i500 from Medit®. This study focused on the impression of an edentulous maxilla in which five implants were placed for implant-supported complete prosthesis. The digital models were superimposed on a digital reference model using dimensional control and metrology software. Angular and distance deviations from the digital reference model were calculated to assess trueness. Dispersion of the values around their mean for each impression was also calculated for precision. The mean distance deviation in absolute value and the direction of the distance deviation were smaller for conventional impressions (p-value < 0.001). The I-500 had the best results regarding angular measurements, followed by Trios 4 and CS3600 (p < 0.001). The conventional and I-500 digital impressions showed the lowest dispersion of values around the mean (p-value < 0.001). Within the limitations of our study, our results revealed that the conventional impression was more accurate than the digital impression, but further clinical studies are needed to confirm these findings.
- Open Access
- 17 February 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (2) , 382
Comprehensive CAD/CAM Prosthetic Rehabilitation Management in a Young Patient with Agenesis: A Case Report
With the advancement in ceramic restorations bonded to the tooth structure, the treatment has become a practicable and conservative option to restore teeth with shape alteration owing to the high demand for aesthetics, with minimum tooth preparation. This article describes the case of a 25-year-old man who was dissatisfied with his smile. After an assessment of the clinical situation, a decision was made to place a full-mouth prosthodontic rehabilitation (monolithic lithium disilicate glass-ceramic, IPS E-max CAD) with minimal tooth preparation, which figures as a conservative full-coverage approach. The restoration of an aesthetic smile resulted in the patient’s satisfaction. Bonding of all monolithic veenerlay and crowns onto minimally prepared teeth figures as conservative treatment in cases of hypodontia.
- 17 February 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (2) , 382
Open AccessComprehensive CAD/CAM Prosthetic Rehabilitation Management in a Young Patient with Agenesis: A Case Report
With the advancement in ceramic restorations bonded to the tooth structure, the treatment has become a practicable and conservative option to restore teeth with shape alteration owing to the high demand for aesthetics, with minimum tooth preparation. This article describes the case of a 25-year-old man who was dissatisfied with his smile. After an assessment of the clinical situation, a decision was made to place a full-mouth prosthodontic rehabilitation (monolithic lithium disilicate glass-ceramic, IPS E-max CAD) with minimal tooth preparation, which figures as a conservative full-coverage approach. The restoration of an aesthetic smile resulted in the patient’s satisfaction. Bonding of all monolithic veenerlay and crowns onto minimally prepared teeth figures as conservative treatment in cases of hypodontia.
- Open Access
- 6 May 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (5) , 542
Dental Trauma Management in a Young Teenager through Endodontics and Implantology: A Case Report
Endodontic treatment is often the first-line procedure to manage the immediate or long-term aftermath of dental trauma, particularly in cases of luxation or avulsion. Failure to manage trauma in the short or medium term leads to significant functional or aesthetic consequences, especially in the adolescence period. Under this specific conditions, endodontic treatment could provide a temporary solution by keeping teeth with poor prognosis on the arch while waiting for better anatomical conditions for implantology. This clinical case aimed to describe the management of a maxilla-facial dental trauma and the following consequences in a 10-year-old male patient. Clinical and radiological examination showed complete extrusive luxation of 11 and 21 and intrusive luxation of 12 and 22. Endodontic treatment of 11 and 21 was performed six months after the trauma. Two years later, the patient was referred to the endodontic department because pink spot lesions appeared on 12 and 22 due to cervical invasive resorptions (class III for 12 and class II for 22). Endodontic treatment of 12 and filling with resin composite of 22 were performed. During the following two years, complication management finally led to placement of four OBI® (Euroteknika, Sallanches, France)-type mini-implants after avulsion of all four maxillary incisors. Palliative endodontic treatment helped maintain the prosthetic space and the volume of supporting tissue needed for future implant placement. The interest of using delaying procedures (palliative endodontic treatments and mini-implants) was to allow the patient to complete growth. Managing early treatment failure of trauma in adolescents has to be pluridisciplinary and should take into account the evaluation of the treatment’s difficulty, the prognosis of the endodontic treatment, the available bone volume and the pubertal growth stage.
- 6 May 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (5) , 542
Open AccessDental Trauma Management in a Young Teenager through Endodontics and Implantology: A Case Report
Endodontic treatment is often the first-line procedure to manage the immediate or long-term aftermath of dental trauma, particularly in cases of luxation or avulsion. Failure to manage trauma in the short or medium term leads to significant functional or aesthetic consequences, especially in the adolescence period. Under this specific conditions, endodontic treatment could provide a temporary solution by keeping teeth with poor prognosis on the arch while waiting for better anatomical conditions for implantology. This clinical case aimed to describe the management of a maxilla-facial dental trauma and the following consequences in a 10-year-old male patient. Clinical and radiological examination showed complete extrusive luxation of 11 and 21 and intrusive luxation of 12 and 22. Endodontic treatment of 11 and 21 was performed six months after the trauma. Two years later, the patient was referred to the endodontic department because pink spot lesions appeared on 12 and 22 due to cervical invasive resorptions (class III for 12 and class II for 22). Endodontic treatment of 12 and filling with resin composite of 22 were performed. During the following two years, complication management finally led to placement of four OBI® (Euroteknika, Sallanches, France)-type mini-implants after avulsion of all four maxillary incisors. Palliative endodontic treatment helped maintain the prosthetic space and the volume of supporting tissue needed for future implant placement. The interest of using delaying procedures (palliative endodontic treatments and mini-implants) was to allow the patient to complete growth. Managing early treatment failure of trauma in adolescents has to be pluridisciplinary and should take into account the evaluation of the treatment’s difficulty, the prognosis of the endodontic treatment, the available bone volume and the pubertal growth stage.
- Open Access
- 20 December 2017
- Published by Springer Nature in BMC Oral Health
- Vol. 17 (1) , 155
A new digital denture procedure: a first practitioners appraisal
Historically, the complete removable denture is the last prosthetic procedure to switch to digital techniques whose advantages are mainly observed in the laboratory stages; however, it is not possible to measure the depressibility of the oral mucosa using optical cameras, thus conventional impression techniques are still necessary. This article describes the clinical and laboratory procedure and practitioners appraisal of the first fifteen digitally designed complete removable dental prostheses. Several systems are now available including the Wieland® Digital Denture® which offers a complete procedure. This system is composed of a five axis-milling machine combined with a laboratory scanner and a design software application. Fifteen rehabilitations were carried out using the Wieland® system. The practitioner’s role is simplified by intraoral recording with a central point and a reduced number of sessions. The prosthesis laboratory requires considerable investment in learning and equipment, making it possible to obtain ideal mounting assemblies in accordance with the occluso-prosthetic concept of bilateral balanced occlusion. The absence of polymerization and therefore of base deformation risks reduce the equilibration step. Finally, the creation of templates as an alternative to the assembly of teeth on wax makes it possible to functionally validate (masticatory and phonatory) the future dentures. However, this procedure still presented some limitations in terms of scanning and software scope of applications. Digital denture design software is relatively efficient and helps to standardize clinical results. However, to this date, improvements of the software are still required for a routine use.
- 20 December 2017
- Published by Springer Nature in BMC Oral Health
- Vol. 17 (1) , 155
Open AccessA new digital denture procedure: a first practitioners appraisal
Historically, the complete removable denture is the last prosthetic procedure to switch to digital techniques whose advantages are mainly observed in the laboratory stages; however, it is not possible to measure the depressibility of the oral mucosa using optical cameras, thus conventional impression techniques are still necessary. This article describes the clinical and laboratory procedure and practitioners appraisal of the first fifteen digitally designed complete removable dental prostheses. Several systems are now available including the Wieland® Digital Denture® which offers a complete procedure. This system is composed of a five axis-milling machine combined with a laboratory scanner and a design software application. Fifteen rehabilitations were carried out using the Wieland® system. The practitioner’s role is simplified by intraoral recording with a central point and a reduced number of sessions. The prosthesis laboratory requires considerable investment in learning and equipment, making it possible to obtain ideal mounting assemblies in accordance with the occluso-prosthetic concept of bilateral balanced occlusion. The absence of polymerization and therefore of base deformation risks reduce the equilibration step. Finally, the creation of templates as an alternative to the assembly of teeth on wax makes it possible to functionally validate (masticatory and phonatory) the future dentures. However, this procedure still presented some limitations in terms of scanning and software scope of applications. Digital denture design software is relatively efficient and helps to standardize clinical results. However, to this date, improvements of the software are still required for a routine use.
- Open Access
Predictive Parameters of Oral Health Quality of Life in Complete Mandibular Denture Wearers Stabilized by Mini-Implants: A Two-Year Follow-Up Study
The frequent instability of mandibular removable complete dentures affects patient Oral Health Related Quality of Life (OHRQoL). An innovative therapeutic strategy used to improve stability involves placing four symphyseal mini-implants. This study was aimed at assessing OHRQoL over time in subjects in which mini-implants were placed and exploring if certain parameters could predict the evolution of their OHRQoL. The OHRQoL of subjects with dentures was assessed using the Geriatric Oral Health Assessment Index (GOHAI) before (T0), 2–6 months (T1), twelve months (T2) and twenty-four or more months (T3) after mini-implant setting. Age, gender and chewing ability were tested as explanatory variables for the change in OHRQoL with time. Thirteen women and six men were included (mean age: 69 ± 10 years). After treatment, mean GOHAI scores at T1, T2 and T3 increased significantly (p < 0.001). The GOHAI-Add mean score was not affected by age or gender. Baseline chewing ability impacted the “functional” and “pain and discomfort” fields of the mean GOHAI scores (p < 0.05). The OHRQoL quickly improved after mini-implant placement in complete denture wearers and then stabilized over time. Baseline chewing ability can be used as a predictive parameter of OHRQoL.
Open AccessPredictive Parameters of Oral Health Quality of Life in Complete Mandibular Denture Wearers Stabilized by Mini-Implants: A Two-Year Follow-Up Study
The frequent instability of mandibular removable complete dentures affects patient Oral Health Related Quality of Life (OHRQoL). An innovative therapeutic strategy used to improve stability involves placing four symphyseal mini-implants. This study was aimed at assessing OHRQoL over time in subjects in which mini-implants were placed and exploring if certain parameters could predict the evolution of their OHRQoL. The OHRQoL of subjects with dentures was assessed using the Geriatric Oral Health Assessment Index (GOHAI) before (T0), 2–6 months (T1), twelve months (T2) and twenty-four or more months (T3) after mini-implant setting. Age, gender and chewing ability were tested as explanatory variables for the change in OHRQoL with time. Thirteen women and six men were included (mean age: 69 ± 10 years). After treatment, mean GOHAI scores at T1, T2 and T3 increased significantly (p < 0.001). The GOHAI-Add mean score was not affected by age or gender. Baseline chewing ability impacted the “functional” and “pain and discomfort” fields of the mean GOHAI scores (p < 0.05). The OHRQoL quickly improved after mini-implant placement in complete denture wearers and then stabilized over time. Baseline chewing ability can be used as a predictive parameter of OHRQoL.
- 1 December 2014
- Vol. 22 (4) , 159-65
Ceramo-Metal Crown or Cad-Cam Rehabilitation: Patient and Practitioner Appraisal.
Crowns produced using CAD-CAM technology must be evaluated so they can be integrated in the dentist's therapeutic arsenal. To this end, an evaluation tool for the fixed element units was developed and tested in a randomized cross-over pilot study. At a hospital centre, 10 single crowns from the same dental preparation and produced using CEREC technology were compared to Ceramo-Metal Crowns produced using a conventional procedure. Practitioners generally evaluated CEREC crowns more positively, corroborating the subjects' preference for these crowns. The CEREC technology used in a hospital setting meets the requirements of both patients and practitioners.
- 1 December 2014
- Vol. 22 (4) , 159-65
Ceramo-Metal Crown or Cad-Cam Rehabilitation: Patient and Practitioner Appraisal.
Crowns produced using CAD-CAM technology must be evaluated so they can be integrated in the dentist's therapeutic arsenal. To this end, an evaluation tool for the fixed element units was developed and tested in a randomized cross-over pilot study. At a hospital centre, 10 single crowns from the same dental preparation and produced using CEREC technology were compared to Ceramo-Metal Crowns produced using a conventional procedure. Practitioners generally evaluated CEREC crowns more positively, corroborating the subjects' preference for these crowns. The CEREC technology used in a hospital setting meets the requirements of both patients and practitioners.
- 1 December 2011
- Published by EDP Sciences in Actualites Odonto-Stomatologiques
- No. 256,p. 335-340
Phase pilote d’élaboration d’un logiciel pédagogique en prothèse adjointe partielle : METACIEL
- 1 December 2011
- Published by EDP Sciences in Actualites Odonto-Stomatologiques
- No. 256,p. 335-340
Phase pilote d’élaboration d’un logiciel pédagogique en prothèse adjointe partielle : METACIEL