Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dawit Bogale Alemayehu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Hybrid Biomechanical Design of Dental Implants: Integrating Solid and Gyroid Triply Periodic Minimal Surface Lattice Architectures for Optimized Stress Distribution

    by Dawit Bogale Alemayehu, Masahiro Todoh, Song-Jeng Huang

    Background: Dental implantology has evolved significantly since the introduction of additive manufacturing, which allows for the reproduction of natural bone’s porous architecture to improve bone tissue compatibility and address stress distribution issues important to long-term implant success. Conventional solid dental implants frequently cause stress shielding, which compromises osseointegration and reduces durability. Aim: The current research proposes to examine the biomechanical efficacy of fully and hybrid gyroid triply periodic minimum surface (TPMS) latticed implants across different cell sizes to optimize stress distribution and improve implant durability. Methods: This study evaluates six fully and hybrid gyroid (TPMS) latticed implants, including fully latticed designs with three cell sizes—FLI_111 (1 mm × 1 mm × 1 mm), FLI_222 (2 mm × 2 mm × 2 mm), and FLI_333 (3 mm × 3 mm × 3 mm)—and hybrid gyroid TPMS latticed implants with solid necks in corresponding sizes—HI_111, HI_222, and HI_333. To enhance initial stability, a square-threaded design was added into the bottom part of both fully and hybrid lattice implants. The designs also incorporate anti-rotational connections to enhance fixation, and they undergo a clinical viability comparison with contemporary implants. To improve lattice designs, finite element analysis (FEA) was utilized through nTopology (nTOP 4.17.3) to balance stiffness and flexibility. To examine mechanical performance under realistic conditions, a dynamic mastication loading simulation was conducted for 1.5 s across three cycles. Results: The findings reveal that hybrid implants, particularly HI_222, exhibited improved mechanical characteristics by reducing micromotions at the bone–implant interface, improving osteointegration, and attaining better stress distribution. Conclusions: By addressing stress shielding and boosting implant performance, this work paves the way for personalized implant designs, developing dental technology, and improving clinical results.


  • Open Access

    Nonlinear Finite Element Analysis of Bone–Implant Contact in Three Short Dental Implant Models with Varying Osseointegration Percentages

    by Dawit Bogale Alemayehu, Masahiro Todoh, Song-Jeng Huang

    Objectives: Dental implants have become a cornerstone of restorative dentistry, providing a long-lasting method for tooth replacement. The degree of osseointegration has a significant effect on biomechanical stability at the bone–implant contact (BIC), determining the continued efficacy of these implants. However, the exact consequences of changing osseointegration levels on different implant designs, especially in bones with variable densities, are not well known. Methods: This study used 3D finite element analysis (FEA) to look at the biomechanical performance of three short dental implants: BioMet 3iT3, Straumann® Standard Plus Short-Regular Neck (SPS-RN), and Straumann® Standard Plus Short-Wide Neck (SPS-WN). This paper tested the implants at four stages of osseointegration: 25%, 50%, 75%, and 100% in both high-density (bone type III) and low-density (bone type IV) cancellous bone. It also created and examined realistic CAD models under static occlusal loading conditions to assess stress distribution and major strains at the bone–implant contact. Results: The study discovered that as osseointegration increases, von Mises stress and principal strains go down significantly for all implant types. The SPS-WN implant had the lowest strain values, especially for bone with low density. These reductions demonstrate increased mechanical stability as the bone–implant interface becomes more capable of dispersing mechanical stresses, minimizing the potential for localized deformation and bone resorption. Conclusions: The results highlight the importance of achieving optimum osseointegration to reduce mechanical stress and increase the lifespan of dental implants. The SPS-WN type implant performed better in biomechanical tests than the others, especially when bone conditions were not ideal. This makes it a great choice for clinical applications that need long-term implant success.


  • Open Access

    Hybrid Biomechanical Design of Dental Implants: Integrating Solid and Gyroid TPMS Lattice Architectures for Optimized Stress Distribution

    by Dawit Bogale Alemayehu, Masahiro Todoh, Song-Jeng Huang

    Dental implantology has evolved greatly as a result of the application of biomechanical engineering concepts, notably the utilization of additive manufacturing technologies that recreate the intricate architecture of real bone. This technique intends to improve functional compatibility with bone tissue while also addressing continuing problems of stress distribution inside dental implants. The research examines two types of dental implants: fully gyroid latticed and hybrid gyroid latticed with a solid neck, comprising three different cell sizes—FI-111, FI-222, FI-333, and their hybrid equivalents HI-111, HI-222, and HI-333. Traditional solid implants often cause stress shielding, which reduces long-term osseointegration and implant durability. Developed using nTopology for lattice configuration and meshing, this design undergoes a comprehensive stress analysis using finite element analysis (FEA). The study seeks to determine the most efficient implant design by maximizing stress distribution and mechanical stiffness. Analyses suggest that hybrid latticed implants, notably the HI-222 type, possess superior mechanical characteristics. These implants successfully balance stiffness and flexibility, reducing stress concentrations and improving stress distribution throughout the implant structure. This balance is critical for decreasing micromotions at the bone-implant interface, boosting osseointegration, and, ultimately, increasing implant longevity and success rates in clinical settings. The paper describes a substantial redesign of dental implants by combining biomechanical engineering and modern additive manufacturing. The novel proposed hybrid structure not only addresses typical challenges such as stress shielding, but it also establishes new standards in implantology, potentially leading to better clinical results and patient quality of life. This complete approach emphasizes the ability of personalized implant designs to fulfill individual clinical demands, indicating a significant improvement in dental treatment technology.

  • Open Access

    Enhanced Energy Absorption with Bioinspired Composite Triply Periodic Minimal Surface Gyroid Lattices Fabricated via Fused Filament Fabrication (FFF)

    by Dawit Bogale Alemayehu, Masahiro Todoh

    Bio-inspired gyroid triply periodic minimum surface (TPMS) lattice structures have been the focus of research in automotive engineering because they can absorb a lot of energy and have wider plateau ranges. The main challenge is determining the optimal energy absorption capacity and accurately capturing plastic plateau areas using finite element analysis (FEA). Using nTop’s Boolean subtraction method, this study combined walled TPMS gyroid structures with a normal TPMS gyroid lattice. This made a composite TPMS gyroid lattice (CTG) with relative densities ranging from 14% to 54%. Using ideaMaker 4.2.3 (3DRaise Pro 2) software and the fused deposition modeling (FDM) Raise3D Pro 2 3D printer to print polylactic acid (PLA) bioplastics in 1.75 mm filament made it possible to slice computer-aided design (CAD) models and fabricate 36 lattice samples precisely using a layer-by-layer technique. Shimadzu 100 kN testing equipment was utilized for the mechanical compression experiments. The finite element approach validates the results of mechanical compression testing. Further, a composite CTG was examined using a field emission scanning electron microscope (FE-SEM) before and after compression testing. The composite TPMS gyroid lattice showed potential as shock absorbers for vehicles with relative densities of 33%, 38%, and 54%. The Gibson–Ashby model showed that the composite TPMS gyroid lattice deformed mainly by bending, and the size effect was seen when the relative densities were less than 15%. The lattice’s relative density had a significant impact on its ability to absorb energy. The research also explored the use of these innovative foam-like composite TPMS gyroid lattices in high-speed crash box scenarios to potentially enhance vehicle safety and performance. The structures have tremendous potential to improve vehicle safety by acting as advanced shock absorbers, which are particularly effective at higher relative densities.


  • Open Access

    Advancing 3D Dental Implant Finite Element Analysis: Incorporating Biomimetic Trabecular Bone with Varied Pore Sizes in Voronoi Lattices

    by Dawit Bogale Alemayehu, Masahiro Todoh, Song-Jeng Huang

    The human mandible’s cancellous bone, which is characterized by its unique porosity and directional sensitivity to external forces, is crucial for sustaining biting stress. Traditional computer- aided design (CAD) models fail to fully represent the bone’s anisotropic structure and thus depend on simple isotropic assumptions. For our research, we use the latest versions of nTOP 4.17.3 and Creo Parametric 8.0 software to make biomimetic Voronoi lattice models that accurately reflect the complex geometry and mechanical properties of trabecular bone. The porosity of human cancellous bone is accurately modeled in this work using biomimetic Voronoi lattice models. The porosities range from 70% to 95%, which can be achieved by changing the pore sizes to 1.0 mm, 1.5 mm, 2.0 mm, and 2.5 mm. Finite element analysis (FEA) was used to examine the displacements, stresses, and strains acting on dental implants with a buttress thread, abutment, retaining screw, and biting load surface. The results show that the Voronoi model accurately depicts the complex anatomy of the trabecular bone in the human jaw, compared to standard solid block models. The ideal pore size for biomimetic Voronoi lattice trabecular bone models is 2 mm, taking in to account both the von Mises stress distribution over the dental implant, screw retention, cortical bone, cancellous bone, and micromotions. This pore size displayed balanced performance by successfully matching natural bone’s mechanical characteristics. Advanced FEA improves the biomechanical understanding of how bones and implants interact by creating more accurate models of biological problems and dynamic loading situations. This makes biomechanical engineering better.


  • Open Access

    Enhanced Energy Absorption in Bioinspired Combined TPMS-Gyroid and Walled TPMS-Gyroid Lattice Structure Manufactured via Fused Filament Fabrication (FFF)

    by Dawit Bogale Alemayehu, Masahiro Todoh

    Bio-inspired gyroid triply periodic minimum surface (TPMS) lattice structures have been the focus of research in automotive engineering because they can absorb a lot of energy and have wider plateau ranges. The main challenge is determining the optimal energy absorption capacity and accurately capturing plastic plateau areas using finite element analysis (FEA). Using nTop's Boolean subtraction method, this study combined walled TPMS gyroid structures with normal TPMS gyroid lattice. This made a composite TPMS-gyroid lattice with relative densities ranging from 14% to 54%. Using the ideaMaker software and the fused deposition modeling (FDM) Raise3D Pro 2 3D printer to print polylactic acid (PLA) bioplastics in 1.75 mm filament made it possible to slice computer aided design (CAD) models and fabricate 36 lattices samples precisely layer by layer technique. Shimadzu 100kN testing equipment was utilized for the mechanical compression experiments. And the validation using finite element analysis (FEA). Further, CTG was examined using a field emission scanning electron microscope (FE-SEM) before and after compression testing. The composite TPMS gyroid lattice showed potential as shock absorbers for vehicles with relative densities of 33%, 38%, and 54%. The Gibson-Ashby model showed that the composite TPMS gyroid lattice deformed mainly by bending, and the size effect was seen when the relative densities were less than 15%. The lattice's relative density had a significant impact on its ability to absorb energy. The research also explored the use of these innovative foam-like composite TPMS-gyroid lattices in high-speed crash box scenarios, potentially enhancing vehicle safety and performance.


  • Open Access

    Advancing 3D Dental Implant FEA: Incorporating Biomimetic Trabecular Bone with Varied Pore Sizes in Voronoi Lattices

    by Dawit Bogale Alemayehu, Masahiro Todoh, Song-Jeng Huang

    The human mandible's cancellous bone, which is characterized by its unique porosity and directional sensitivity to external forces, is crucial for sustaining biting stress. Traditional CAD models fail to fully represent bone's anisotropic structure and thus depend on simple isotropic assumptions. For our research, we use the latest versions of nTopology and Creo Parametric software to make biomimetic Voronoi lattice models that accurately reflect the complex geometry and mechanical properties of trabecular bone. The porosity of human cancellous bone is accurately modeled in this work using biomimetic Voronoi lattice models. The porosities range from 70% to 95%, which can be achieved by changing the pore sizes to 1.0 mm, 1.5 mm, 2.0 mm, and 2.5 mm. Finite element analysis (FEA) was used to examine the displacements, stresses, and strains acting on dental implants with a buttress thread, abutment, retaining screw, and biting load surface. The results show that the Voronoi model accurately depicts the complex anatomy of the trabecular bone in the human jaw, compared to standard solid block models. The ideal pore size for biomimetic Voronoi lattice trabecular bone models is 2 mm, taking into account both the von Mises stress distribution over the dental implant, screw retention, cortical bone, cancellous bone, and micromotions. This pore size displayed balanced performance by successfully matching natural bone's mechanical characteristics. Advanced finite element analysis (FEA) improves biomechanical understanding of how bones and implants interact by creating more accurate models of biological problems and dynamic loading situations. This makes biomechanical engineering better.


  • Open Access

    Improving Pure Titanium’s Biological and Mechanical Characteristics through ECAP and Micro-Arc Oxidation Processes

    by Dawit Bogale Alemayehu, Masahiro Todoh, Jang-Hsing Hsieh, Chuan Li, Song-Jeng Huang

    Pure titanium is limited to be used in biomedical applications due to its lower mechanical strength compared to its alloy counterpart. To enhance its properties and improve medical implants feasibility, advancements in titanium processing technologies are necessary. One such technique is equal-channel angular pressing (ECAP) for its severe plastic deformation (SPD). This study aims to surface modify commercially pure titanium using micro-arc oxidation (MAO) or plasma electrolytic oxidation (PEO) technologies, and mineral solutions containing Ca and P. The composition, metallography, and shape of the changed surface were characterized using X-ray diffraction (XRD), digital optical microscopy (OM), and scanning electron microscope (SEM), respectively. A microhardness test is conducted to assess each sample’s mechanical strength. The weight % of Ca and P in the coating was determined using energy dispersive spectroscopy (EDS), and the corrosion resistance was evaluated through potentiodynamic measurement. The behavior of human dental pulp cell and periodontal cell behavior was also studied through a biomedical experiment over a period of 1-, 3-, and 7-days using culture medium, and the cell death and viability can be inferred with the help of enzyme-linked immunosorbent assay (ELISA) since it can detect proteins or biomarkers secreted by cells undergoing apoptosis or necrosis. This study shows that the mechanical grain refinement method and surface modification might improve the mechanical and biomechanical properties of commercially pure (CP) titanium. According to the results of the corrosion loss measurements, 2PassMAO had the lowest corrosion rate, which is determined to be 0.495 mmpy. The electrode potentials for the 1-pass and 2-pass coated samples are 1.44 V and 1.47 V, respectively. This suggests that the coating is highly effective in reducing the corrosion rate of the metallic CP Ti sample. Changes in the grain size and the presence of a high number of grain boundaries have a significant impact on the corrosion resistance of CP Ti. For ECAPED and surface-modified titanium samples in a 3.6% NaCl electrolyte solution, electrochemical impedance spectroscopy (EIS) properties are similar to Nyquist and Bode plot fitting. In light of ISO 10993-5 guidelines for assessing in vitro cytotoxicity, this study contributes valuable insights into pulp and periodontal cell behavior, focusing specifically on material cytotoxicity, a critical factor determined by a 30% decrease in cell viability.


  • Open Access

    Improving Pure Titanium's Biological and Mechanical Characteristics through ECAP and Micro Arc Oxidation Processes

    by Dawit Bogale Alemayehu, Masahiro Todoh, J. H. Hsieh, Chuan Li, Song-Jeng Huang

    Pure titanium is limited to be used in biomedical applications due to its lower mechanical strength compared to its alloy counterpart. To enhance its properties and improve medical implants feasibility, advancements in titanium processing technologies are necessary. One such technique is equal channel angular pressing (ECAP) for its severe plastic deformation (SPD). This study aimed to surface modify commercially pure titanium using micro arc oxidation (MAO) technology and mineral solutions containing Ca and P. The composition and shape of the changed surface were characterized using X-ray diffraction (XRD) and scanning electron microscope (SEM), respectively. The weight % of Ca and P in the coating was determined using Energy Dispersive Spectroscopy (EDS), and the corrosion resistance was evaluated through potentiodynamic measurement. The behavior of human dental pulp cell and periodontal cell behavior was also studied through a biomedical experiment over a period of 1-, 3-, and 7-days using trypsin as the culture medium and ELISA as the observation method. This study showed that the mechanical grain refinement method and surface modification significantly improved the biomechanical properties of commercially pure (CP) Titanium. Although the results showed variations in the absorbance values of cells cultured on different surfaces, this study provides valuable insights into pulp cell behavior and advances the field of biomedical research.


  • A Free-Standing, Silent, Micro/Mesoscale Combustion-Powered Thermoelectric Generator Based on Natural Convection Cooling

    by Mikiyas Bekele Tulu, Guoneng Li, Dawit Bogale Alemayehu, Minbo Yi

    In recent years, the world has become increasingly interested in power generation using thermoelectric generators (TEG) because of the advantage of converting heat directly to electricity. In this work, experimental studies have been carried out on micro/mesoscale combustor-powered thermoelectric generators (MCP-TEG) to evaluate the influence of different types of heat sinks on the cold side of MCP-TEG. The micro/mesoscale combustor was connected with Bi2Te3 based TEG1-12708 thermoelectric modules from both sides along with a heat sink on the cold side of the modules. The system uses natural convection cooling with a flat-plate aluminum heat sink. The MCP-TEG generates electrical power of 0.242 W with an overall efficiency of 0.3% at a hot-end temperature of 351 K. Power load feature and time history tests are conducted to evaluate the performance of the MCP-TEG system and comparisons of various related studies were made.