Bani Gandhi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bani Gandhi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Nallanthighal Srinivasa Raghava
ECE Department, Delhi Technological University, New Delhi, India
3 shared publications N. S. Raghava
Delhi Technological University
2 shared publicationsAnil Kumar Shukla
Amity University
1 shared publicationG. N. Pandey
Amity Institute of Applied Science, Amity University
1 shared publication
Latest Publications
- 2 January 2026
- Published by Springer Nature
- p. 37-51
Fabrication and Analysis of Graphene and Its Hybrid-Based ECG Electrodes for Wireless Healthcare Applications
- 2 January 2026
- Published by Springer Nature
- p. 37-51
Fabrication and Analysis of Graphene and Its Hybrid-Based ECG Electrodes for Wireless Healthcare Applications
- Open Access
Fabrication and Analysis of Carboxylic Acid-Functionalized SWCNT/PDMS-Based Electrodes for ECG Monitoring via IoT
This paper presents the design and fabrication of flexible and gel-less electrodes using carboxylic acid-functionalized single-walled carbon nanotubes (SWCNT-COOHs) and polydimethylsiloxane (PDMS) at thirteen different concentrations. The dispersion was attained by magnetic stirring and sonication using isopropyl alcohol (IPA). Physical characterizations like Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), and Fourier Transform Infrared Spectroscopy (FTIR) were performed. The electrodes were fabricated using molds. The percolation threshold was achieved at 4 wt%. The ECG results were compared with conventional ECG electrodes and 3.5 wt% displayed the best results. Also, after using the electrodes for 5 days, the ECG signals did not degrade and no skin allergies were observed. The fabricated electrodes are suitable for long-term and continuous ECG monitoring, facilitated with the help of an Internet of Things (IoT) tracking system. The data can then be transmitted to the medical expert and loaded onto the cloud server for analysis.
Open AccessFabrication and Analysis of Carboxylic Acid-Functionalized SWCNT/PDMS-Based Electrodes for ECG Monitoring via IoT
This paper presents the design and fabrication of flexible and gel-less electrodes using carboxylic acid-functionalized single-walled carbon nanotubes (SWCNT-COOHs) and polydimethylsiloxane (PDMS) at thirteen different concentrations. The dispersion was attained by magnetic stirring and sonication using isopropyl alcohol (IPA). Physical characterizations like Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), and Fourier Transform Infrared Spectroscopy (FTIR) were performed. The electrodes were fabricated using molds. The percolation threshold was achieved at 4 wt%. The ECG results were compared with conventional ECG electrodes and 3.5 wt% displayed the best results. Also, after using the electrodes for 5 days, the ECG signals did not degrade and no skin allergies were observed. The fabricated electrodes are suitable for long-term and continuous ECG monitoring, facilitated with the help of an Internet of Things (IoT) tracking system. The data can then be transmitted to the medical expert and loaded onto the cloud server for analysis.
- 23 August 2022
- Published by Springer Nature in Biomedical Microdevices
- Vol. 24 (3) , 1-14
Graphene and graphene nanohybrid composites-based electrodes for physiological sensing applications
In this paper, three categories of ECG electrodes were fabricated. Graphene/PDMS(Polydimethylsiloxane)(G-I), Graphene/MWCNT-COOH(Carboxylic-acid functionalized Multi-walled Carbon Nanotubes)/PDMS(G-II),and Graphene/SWCNT-COOH(Carboxylic-acid functionalized Single-walled Carbon Nanotubes)/PDMS(G-III). Each group had thirteen electrodes with varying concentrations ranging from 0.1-5wt%. Since CNTs get tangled easily, it becomes necessary to disperse them properly. To achieve optimal dispersion, CNTs were first sonicated with Isopropyl Alcohol (IPA), and then with PDMS. Mold casting was the technique used for fabricating the electrodes. The results were compared with the conventional ECG electrodes. Best results were achieved from G-III at 3wt% as the value of capacitance is high (0.172nF) as compared to G-I and G-III values at 3wt% which are 0.036nF (0.036nF) and 0.015nF respectively. As capacitance has an inverse relationship with the resistance and impedance, thus at 3wt% the resistance (0.361MΩ) and impedance (0.36MΩ) values are low, which satisfies the relationship. The values of resistance and impedance of G-II are low when compared with the values of G-I and G-II. Great results and ECG waveform are achieved with 3wt% for G-II, which also uses less nanomaterials to produce such great ECG results. It was observed that even after using the electrodes for 5 days, the ECG signal did not degrade over time and no skin allergies were detected for any of the three groups. The ECG tracking system was developed on the concept of the Internet-of-Things (IoT) using various electronic hardware components and software solutions. The results from the fabricated electrodes were promising and were suitable for long-term, and continuous ECG monitoring.
- 23 August 2022
- Published by Springer Nature in Biomedical Microdevices
- Vol. 24 (3) , 1-14
Graphene and graphene nanohybrid composites-based electrodes for physiological sensing applications
In this paper, three categories of ECG electrodes were fabricated. Graphene/PDMS(Polydimethylsiloxane)(G-I), Graphene/MWCNT-COOH(Carboxylic-acid functionalized Multi-walled Carbon Nanotubes)/PDMS(G-II),and Graphene/SWCNT-COOH(Carboxylic-acid functionalized Single-walled Carbon Nanotubes)/PDMS(G-III). Each group had thirteen electrodes with varying concentrations ranging from 0.1-5wt%. Since CNTs get tangled easily, it becomes necessary to disperse them properly. To achieve optimal dispersion, CNTs were first sonicated with Isopropyl Alcohol (IPA), and then with PDMS. Mold casting was the technique used for fabricating the electrodes. The results were compared with the conventional ECG electrodes. Best results were achieved from G-III at 3wt% as the value of capacitance is high (0.172nF) as compared to G-I and G-III values at 3wt% which are 0.036nF (0.036nF) and 0.015nF respectively. As capacitance has an inverse relationship with the resistance and impedance, thus at 3wt% the resistance (0.361MΩ) and impedance (0.36MΩ) values are low, which satisfies the relationship. The values of resistance and impedance of G-II are low when compared with the values of G-I and G-II. Great results and ECG waveform are achieved with 3wt% for G-II, which also uses less nanomaterials to produce such great ECG results. It was observed that even after using the electrodes for 5 days, the ECG signal did not degrade over time and no skin allergies were detected for any of the three groups. The ECG tracking system was developed on the concept of the Internet-of-Things (IoT) using various electronic hardware components and software solutions. The results from the fabricated electrodes were promising and were suitable for long-term, and continuous ECG monitoring.
- 31 May 2020
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 71 (1) , 24-43
Fabrication Techniques for Carbon Nanotubes Based ECG Electrodes: A Review
Alternatives to the conventional wet ECG (Electrocardiogram) electrodes are highly in demand in the medical field, primarily when the prolongated recording of ECG signals is required. The lifestyle possessed by people nowadays encourages heart diseases to hover around us, and it becomes pertinent for managing one’s health, which is not inhibited by parameters such as time-span, distance, and space. Hence, this system entails ECG sensors that are light-weight, highly conductive, wearable, and flexible. For devising such a system, such materials should be employed, which possess these characteristics. Therefore, this work focuses on Carbon Nanotubes based ECG sensors. These nanomaterials possess the specifications as mentioned above, and most importantly, these sensors can be easily incorporated with the various IoT platforms available. This system is a combination of nanoelectronics and wireless communication technologies, which allows the ECG signals to be monitored, recorded, and communicated to the medical expert in a remote location. Further, it helps in providing immediate assistance to the patient in need, consequently reviving many deaths due to various heart diseases. Subsequently, it becomes necessary to discuss the different approaches to craft the ECG sensors, which can be used in this system. This paper focuses on the review of several CNT based ECG sensor fabrication methodologies such as Screen printing, Bar-coating, Metal patterning, Mold creation so on and so forth.
- 31 May 2020
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 71 (1) , 24-43
Fabrication Techniques for Carbon Nanotubes Based ECG Electrodes: A Review
Alternatives to the conventional wet ECG (Electrocardiogram) electrodes are highly in demand in the medical field, primarily when the prolongated recording of ECG signals is required. The lifestyle possessed by people nowadays encourages heart diseases to hover around us, and it becomes pertinent for managing one’s health, which is not inhibited by parameters such as time-span, distance, and space. Hence, this system entails ECG sensors that are light-weight, highly conductive, wearable, and flexible. For devising such a system, such materials should be employed, which possess these characteristics. Therefore, this work focuses on Carbon Nanotubes based ECG sensors. These nanomaterials possess the specifications as mentioned above, and most importantly, these sensors can be easily incorporated with the various IoT platforms available. This system is a combination of nanoelectronics and wireless communication technologies, which allows the ECG signals to be monitored, recorded, and communicated to the medical expert in a remote location. Further, it helps in providing immediate assistance to the patient in need, consequently reviving many deaths due to various heart diseases. Subsequently, it becomes necessary to discuss the different approaches to craft the ECG sensors, which can be used in this system. This paper focuses on the review of several CNT based ECG sensor fabrication methodologies such as Screen printing, Bar-coating, Metal patterning, Mold creation so on and so forth.
- 23 September 2017
- Published by Springer Nature in Springer Proceedings in Physics
- p. 551-557
Design of 1 × 4 All Optical Splitter Based on 2D Photonic Crystal
- 23 September 2017
- Published by Springer Nature in Springer Proceedings in Physics
- p. 551-557
Design of 1 × 4 All Optical Splitter Based on 2D Photonic Crystal