Yunze Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yunze Yang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Nongjian Tao
Biodesign Center for Bioelectronics and Biosensors, Arizona State University, Tempe, AZ 85287
3 shared publications - Shaopeng Wang
Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA
2 shared publications - Guangzhong Ma
Zhejiang Key Laboratory of Excited-State Energy Conversion and Energy Storage, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
1 shared publication - Guangzhong Ma
Arizona State University
1 shared publication - Hao Zhu
Nanjing University
1 shared publication Hui Yu
Center for Biosensors and Bioelectronics, Biodesign Institute, Arizona State University
1 shared publication
Latest Publications
- Open Access
Optical imaging of single protein size, charge, mobility, binding and conformational change
Protein analysis has relied on electrophoresis, mass spectroscopy and immunoassay, which separate, detect and identify proteins based on the size, charge, mobility and binding to antibodies. However, measuring these quantities at the single molecule level has not been possible. We tether a protein to a surface with a flexible polymer, drive the protein into mechanical oscillation with an alternating electric field, and image the protein oscillation with a near field imaging method, from which we determine the size, charge, mobility of the protein. We also measure binding of antibodies to single proteins and ligand binding-induced conformational changes in single proteins. This work provides new capabilities for protein analysis and disease biomarker detection at the single molecule level.
Open AccessOptical imaging of single protein size, charge, mobility, binding and conformational change
Protein analysis has relied on electrophoresis, mass spectroscopy and immunoassay, which separate, detect and identify proteins based on the size, charge, mobility and binding to antibodies. However, measuring these quantities at the single molecule level has not been possible. We tether a protein to a surface with a flexible polymer, drive the protein into mechanical oscillation with an alternating electric field, and image the protein oscillation with a near field imaging method, from which we determine the size, charge, mobility of the protein. We also measure binding of antibodies to single proteins and ligand binding-induced conformational changes in single proteins. This work provides new capabilities for protein analysis and disease biomarker detection at the single molecule level.
- Open Access
Time-resolved digital immunoassay for rapid and sensitive quantitation of procalcitonin with plasmonic imaging
Timely diagnosis of acute diseases improves treatment outcomes and saves lives, but it requires fast and precision quantification of biomarkers. Here we report a time-resolved digital immunoassay based on plasmonic imaging of binding of single nanoparticles to biomarkers captured on a sensor surface. The real-time and high contrast of plasmonic imaging lead to fast and precise counting of the individual biomarkers over a wide dynamic range. We demonstrated the detection principle, evaluated the performance of the method using procalcitonin (PCT) as an example, and achieved a limit of detection of ~ 3 pg/mL, dynamic range of 4-12500 pg/mL, for a total detection time of ~ 25 mins.
Open AccessTime-resolved digital immunoassay for rapid and sensitive quantitation of procalcitonin with plasmonic imaging
Timely diagnosis of acute diseases improves treatment outcomes and saves lives, but it requires fast and precision quantification of biomarkers. Here we report a time-resolved digital immunoassay based on plasmonic imaging of binding of single nanoparticles to biomarkers captured on a sensor surface. The real-time and high contrast of plasmonic imaging lead to fast and precise counting of the individual biomarkers over a wide dynamic range. We demonstrated the detection principle, evaluated the performance of the method using procalcitonin (PCT) as an example, and achieved a limit of detection of ~ 3 pg/mL, dynamic range of 4-12500 pg/mL, for a total detection time of ~ 25 mins.
- Open Access
Imaging action potential in single mammalian neurons by tracking the accompanying sub-nanometer mechanical motion
Action potentials in neurons have been studied traditionally by the patch clamp and more recently by the fluorescence detection methods. Here we describe a label-free optical imaging method that can measure mechanical motion in single cells with sub-nanometer detection limit and sub-millisecond temporal resolution. Using the method, we have observed sub-nanometer mechanical motion accompanying the action potential in single mammalian neurons. The shape and width of the transient displacement are similar to those of the electrically recorded action potential, but the amplitude varies from neuron to neuron, and from one region of a neuron to another, ranging from 0.2 - 0.4 nm. The work indicates that action potentials may be studied non-invasively in single mammalian neurons by label-free imaging of the accompanying subnanometer mechanical motion.
Open AccessImaging action potential in single mammalian neurons by tracking the accompanying sub-nanometer mechanical motion
Action potentials in neurons have been studied traditionally by the patch clamp and more recently by the fluorescence detection methods. Here we describe a label-free optical imaging method that can measure mechanical motion in single cells with sub-nanometer detection limit and sub-millisecond temporal resolution. Using the method, we have observed sub-nanometer mechanical motion accompanying the action potential in single mammalian neurons. The shape and width of the transient displacement are similar to those of the electrically recorded action potential, but the amplitude varies from neuron to neuron, and from one region of a neuron to another, ranging from 0.2 - 0.4 nm. The work indicates that action potentials may be studied non-invasively in single mammalian neurons by label-free imaging of the accompanying subnanometer mechanical motion.