JFJoseph Firrantello

Joseph Firrantello

*This is an algorithmically generated author record based on publicly available information.

Joseph Firrantello has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • William P. Bahnfleth

    Department of Architectural Engineering and Director of the Indoor Environment Center, The Pennsylvania State University, University Park, PA, USA

    5 shared publications
  • Bin Hu

    Graduate Research Assistant, Indoor Environment Center, Dept. of Architectural Engineering, The Pennsylvania State Univ., 104 Engineering Unit A, University Park, PA 16802

    1 shared publication
  • Brandolyn Thran

    Assistant Professor, Dept. of Architectural Engineering, Sejong Univ., 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747, Korea

    1 shared publication
  • Chandra Sekhar

    Department of the Built Environment, National University of Singapore, Singapore

    1 shared publication
  • James D. Freihaut

    Department of Architectural Engineering, Penn State College of Engineering, University Park, PA 16802, USA

    1 shared publication
  • Kok Wai Cheong

    Department of Building, National University of Singapore, 4 Architecture Drive, Singapore 117566, Singapore

    1 shared publication

Latest Publications

  • Simulation and monetization of collateral airborne infection risk improvements from ultraviolet germicidal irradiation for coil maintenance

    by Joseph Firrantello, William Bahnfleth

    Ultraviolet germicidal irradiation of cooling coils controls biofouling that increases airflow resistance and decreases heat transfer coefficient. Though lower in power than air disinfection systems, coil ultraviolet germicidal irradiation systems should provide some collateral air treatment benefit. This benefit is estimated through monetization of simulated nonfatal illness spread in a group of commercial buildings. Benefits were quantified using appropriate metrics for each building type: work-loss days for office buildings, hospital acquired infections for healthcare facilities, and disability adjusted life years for schools. The pre-ultraviolet germicidal irradiation annual cost of occupant illness was the same order of magnitude as annual energy cost. Area-normalized cost was similar in magnitude for all buildings. The collateral air disinfection of coil surface ultraviolet germicidal irradiation reduced baseline illness costs by 3.5% or less, but the resulting cost savings exceeded the energy cost to operate the coil ultraviolet germicidal irradiation systems by as much as a factor of 20. The effectiveness of air cleaning methods already in place, such as ventilation and filtration, directly influences the incremental benefit of additional air cleaning measures.


  • Open Access

    Field measurement and modeling of UVC cooling coil irradiation for heating, ventilating, and air conditioning energy use reduction (RP-1738)—Part 1: Field measurements

    by Joseph Firrantello, William Bahnfleth, Paul Kremer

    Wet cooling coil surfaces can provide opportunities for microorganism growth. This biological fouling (biofouling) increases airside pressure drop and decreases airside heat transfer coefficient. Ultraviolet germicidal irradiation is one method to eliminate biofouling. The current article reports field measurements of changes in pressure drop and heat-transfer characteristics of fouled coils treated with ultraviolet germicidal irradiation designed for surface disinfection. Ultraviolet germicidal irradiation systems were installed in operating air-handling units with visibly fouled cooling coils at sites in Tampa, Florida and University Park, Pennsylvania. Pressure drop data were controlled for airflow and latent load, and overall heat-transfer coefficient data were controlled for heat exchanger entering conditions. Analysis of Tampa site data showed an initial mean 22.70% to 22.72% decrease (µ ± 2σ) in airside pressure drop and a mean 13.2% to 13.6% (µ ± 2σ) increase in overall heat-transfer coefficient. Longer-term improvement was 14.6% for the airside pressure drop and 15.7% for overall heat-transfer coefficient, though the decrease in pressure drop improvement was not able to be explained. The University Park, Pennsylvania site, cleaned by unaware maintenance personnel before data collection, had an initial mean 10.3% pressure drop improvement and 57.7% overall heat-transfer coefficient improvement, followed by a long-term 0% pressure drop improvement and 36.7% overall heat-transfer coefficient improvement.


  • Open Access

    Field measurement and modeling of UVC cooling coil irradiation for heating, ventilating, and air conditioning energy use reduction (RP-1738)—Part 2: Energy, indoor air quality, and economic modeling

    by Joseph Firrantello, William Bahnfleth

    Ultraviolet germicidal irradiation of cooling coil airside surfaces is used to mitigate biofouling caused by viable microorganisms captured from the air. However, few peer-reviewed studies have investigated its effectiveness. Part 1 of this study presents the results of field measurements of changes in coil performance after treatment with ultraviolet germicidal irradiation. Part 2 reports modeled energy use and indoor air quality impacts of coil irradiation, as well as results of a life-cycle cost analysis that combines energy, indoor air quality, capital, and maintenance costs. Life-cycle costs with coil ultraviolet germicidal irradiation are compared to life-cycle costs with mechanical coil cleaning. Models from the U.S. Department of Energy Commercial Reference Buildings set were used to predict the benefit of ultraviolet germicidal irradiation treatment of fouled coils for 7 buildings in 16 climate zones using pressure drop reduction estimates bounded by experimental results from Part 1 and results reported in literature. Indoor air quality benefits were estimated using a stochastic implementation of the Wells-Riley equation to predict infection rates and monetized metrics appropriate to the various occupancies considered. Using lower estimates of ultraviolet germicidal irradiation energy use impact, ultraviolet germicidal irradiation was economically superior to mechanical cleaning only when collateral air treatment benefits were considered. At the higher level of estimated improvement, ultraviolet germicidal irradiation was superior even without consideration of air quality impact.


  • Effects of an ultraviolet coil irradiation system on the airside heat transfer coefficient and low ΔT syndrome in a hot and humid climate

    by Yi Wang, Chandra Sekhar, William P. Bahnfleth, Kok Wai Cheong, Joseph Firrantello

    Biological fouling (biofouling) on cooling coil surfaces acts as thermal insulation, impeding heat transfer from air to coil surfaces, decreasing airside heat transfer coefficient and degrading coil cooling capacity. It is also a common cause of low ΔT syndrome in chilled water distribution systems. The effects of a commercially available ultraviolet germicidal irradiation system installed in a variable air volume system on the airside heat transfer coefficient, cooling coil capacity, and its potential to mitigate low ΔT syndrome were investigated via a field test. Energy-related measurements including chilled water supply/return temperature, water-/airflow rate and entering/leaving air temperature/relative humidity commenced 4 months before turning on ultraviolet lamps and continued for 10 months after ultraviolet germicidal irradiation intervention. The effects of the ultraviolet germicidal irradiation system were evaluated via a “before ultraviolet” and “after ultraviolet” comparison. After ultraviolet intervention, within the face velocity range of 1.5–3.0 m/s, the airside heat transfer coefficient increased by 11.8%–20.1%, which translated into 8.8%–10.2% increase in the overall enthalpy-based thermal conductance. The coil total cooling capacity and latent cooling capacity increased by 3.3%–3.8% and 4.5%–5.7%, respectively. The chilled water flow rate required to maintain the leaving air temperature set-point decreased by 8.0%–11.9% and the water-side temperature difference increased by 0.4°C–0.6°C.


  • Effects of HVAC System and Building Characteristics on Exposure of Occupants to Short-Duration Point Source Aerosol Releases

    by Joseph T. Firrantello, Ponkamon Aumpansub, William P. Bahnfleth, Bin Hu, James D. Freihaut, Brandolyn Thran, Sherri Hutchens

    This paper presents results from the simulation of localized, short-duration bioaerosol releases in a hypothetical building similar to a dormitory or barracks using public domain multizone air flow and contaminant dispersion modeling software. The primary purpose of the modeling was to generate example exposure data to be used in the development of a comprehensive microbial risk assessment methodology. However, these results are also of intrinsic interest for what they reveal about the contribution of various building characteristics to risk from airborne contaminants. A variety of parameters were varied, including building construction, heating, ventilating, and air-conditioning (HVAC) system design, and release characteristics, among others. Results of these simulations demonstrate the variability of exposure possible under different scenarios and, more particularly, the impact that HVAC design decisions can have on risk. Although a single building and restricted set of scenarios was investigated, several general conclusions could be drawn regarding factors, such as HVAC zoning and filter maintenance, that intrinsically contribute to vulnerability reduction.