David W. MacPhee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David W. MacPhee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Erguvan
Department of Mechanical Engineering, the University of Alabama, Tuscaloosa, AL 35487, USA
4 shared publications - Roohany Mahmud
Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824, USA
3 shared publications - Kellis C. Kincaid
Department of Mechanical Engineering, University of Alabama, Tuscaloosa, AL 35401, USA
2 shared publications - Lalit Roy
Department of Mechanical Engineering, University of Alabama, Tuscaloosa, AL 35401, USA
2 shared publications - Anshuman Vyas1 shared publication
- Asfaw Beyene
San Diego State University, 5500 Campanile Drive, San Diego, CA, 92182, USA
1 shared publication
Latest Publications
- 6 May 2026
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 201
Investigation of air bubble sizes in naturally-aspirated Venturi flows
- 6 May 2026
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 201
Investigation of air bubble sizes in naturally-aspirated Venturi flows
- Open Access
- 19 September 2024
- Published by IntechOpen in Green Energy and Environmental Technology
- Vol. 3
Performance Assessment of Confined Tube Aerators in Parallel Configuration
Aeration plays a major role in the activated-sludge wastewater treatment process. Microbes require an oxygen-enriched environment to digest organic materials and remove nutrients from the wastewater stream. For providing this oxygen, artificial aeration is required, which is responsible for the majority of energy use in treatment plants. Typically, this is accomplished with diffused aerators, where pressurized air is forced through a porous medium at the bottom of deep basins, and bubbles float up through the water column transferring oxygen in the process. This is a relatively energy-intensive process, which is prone to fouling at the porous media. In this study, a Confined Tube Aeration (CTA) system is proposed, where a pump forces water through a Venturi injector, where air is naturally drawn in. At the Venturi discharge, the flow is diverted to a coiled tube in which oxygen transfer occurs. This study analyzes the effect of parallelizing the CTA system with multiple injectors and at varying pump speeds (flow rates). Using experimental and analytical means, the maximum standard aeration efficiency was found to be with three injectors in parallel, at maximum pump speed, and utilizing a CTA with diameter 31.75 mm and length 3.048 m. This value was found to be 0.542 kg O2/kWh, and represents a 25% increase over the single-injector case. Although the analyses herein utilize a relatively small (0.746 kW) pump, these results indicate that CTA systems may scale well to larger pump sizes necessary for full-scale municipal wastewater treatment.
- 19 September 2024
- Published by IntechOpen in Green Energy and Environmental Technology
- Vol. 3
Open AccessPerformance Assessment of Confined Tube Aerators in Parallel Configuration
Aeration plays a major role in the activated-sludge wastewater treatment process. Microbes require an oxygen-enriched environment to digest organic materials and remove nutrients from the wastewater stream. For providing this oxygen, artificial aeration is required, which is responsible for the majority of energy use in treatment plants. Typically, this is accomplished with diffused aerators, where pressurized air is forced through a porous medium at the bottom of deep basins, and bubbles float up through the water column transferring oxygen in the process. This is a relatively energy-intensive process, which is prone to fouling at the porous media. In this study, a Confined Tube Aeration (CTA) system is proposed, where a pump forces water through a Venturi injector, where air is naturally drawn in. At the Venturi discharge, the flow is diverted to a coiled tube in which oxygen transfer occurs. This study analyzes the effect of parallelizing the CTA system with multiple injectors and at varying pump speeds (flow rates). Using experimental and analytical means, the maximum standard aeration efficiency was found to be with three injectors in parallel, at maximum pump speed, and utilizing a CTA with diameter 31.75 mm and length 3.048 m. This value was found to be 0.542 kg O2/kWh, and represents a 25% increase over the single-injector case. Although the analyses herein utilize a relatively small (0.746 kW) pump, these results indicate that CTA systems may scale well to larger pump sizes necessary for full-scale municipal wastewater treatment.
- Open Access
Performance Assessment of Venturi-Assisted Confined Tube Aerators with Varying Diameter
A significant amount of energy in wastewater treatment plants is spent on aeration to treat the organic matter with microorganisms in an oxygen-enriched environment. In this study, a novel and simplistic aeration concept known as Confined Tube Aeration (CTA) is proposed, in which the main elements are a Venturi injector and a coiled tube at its outlet. Two Venturi injector diameters were chosen for evaluation in this study, measuring 1 inch (25.4 mm) and 4 inch (101.6 mm). In this study, a relationship was developed between air suction rate and pressure differential across the injector. Then, a numerical model was developed to analyze hydrodynamic conditions and evaluate system performance. The main findings are that the larger diameter aerator performs 20% better than the smaller injector in terms of standard aeration efficiency (SAE), with a maximal value of 0.74 kgO2/kWh found for the larger diameter system. These results suggest that future SAE improvements may be made for larger diameter systems in full-scale wastewater treatment applications with suitably designed injectors.
Open AccessPerformance Assessment of Venturi-Assisted Confined Tube Aerators with Varying Diameter
A significant amount of energy in wastewater treatment plants is spent on aeration to treat the organic matter with microorganisms in an oxygen-enriched environment. In this study, a novel and simplistic aeration concept known as Confined Tube Aeration (CTA) is proposed, in which the main elements are a Venturi injector and a coiled tube at its outlet. Two Venturi injector diameters were chosen for evaluation in this study, measuring 1 inch (25.4 mm) and 4 inch (101.6 mm). In this study, a relationship was developed between air suction rate and pressure differential across the injector. Then, a numerical model was developed to analyze hydrodynamic conditions and evaluate system performance. The main findings are that the larger diameter aerator performs 20% better than the smaller injector in terms of standard aeration efficiency (SAE), with a maximal value of 0.74 kgO2/kWh found for the larger diameter system. These results suggest that future SAE improvements may be made for larger diameter systems in full-scale wastewater treatment applications with suitably designed injectors.
- 20 January 2023
- Published by Springer Nature in Energy Efficiency
- Vol. 16 (1) , 1-15
Effect of bubble size and column depth on diffused aerator efficiency
- 20 January 2023
- Published by Springer Nature in Energy Efficiency
- Vol. 16 (1) , 1-15
Effect of bubble size and column depth on diffused aerator efficiency
- 2 June 2022
- Published by Elsevier in Journal of Fluids and Structures
- Vol. 112
Aerodynamic behavior of curved flexible wings
- 2 June 2022
- Published by Elsevier in Journal of Fluids and Structures
- Vol. 112
Aerodynamic behavior of curved flexible wings
- Open Access
Double-Multiple Streamtube Analysis of a Flexible Vertical Axis Wind Turbine
Vertical-axis wind turbines (VAWTs) have drawn increased attention for off-grid and off-shore power generation due to inherent advantages over the more popular horizontal-axis wind turbines (HAWTs). Among these advantages are generator locale, omni-directionality and simplistic design. However, one major disadvantage is lower efficiency, which can be alleviated through blade pitching. Since each blade must transit both up- and down-stream each revolution, VAWT blade pitching techniques are not yet commonplace due to increased complexity and cost. Utilizing passively-morphing flexible blades can offer similar results as active pitching, requiring no sensors or actuators, and has shown promise in increasing VAWT performance in select cases. In this study, wind tunnel tests have been conducted with flexible and rigid-bladed NACA 0012 airfoils, in order to provide necessary input data for a Double-Multiple Stream-Tube (DMST) model. The results from this study indicate that a passively-morphing VAWT can achieve a maximum power coefficient () far exceeding that for a rigid-bladed VAWT (18.9% vs. 10%) with reduced normal force fluctuations as much as 6.9%. Operational range of tip-speed ratio also is observed to increase by a maximum of 40.3%.Open AccessDouble-Multiple Streamtube Analysis of a Flexible Vertical Axis Wind Turbine
Vertical-axis wind turbines (VAWTs) have drawn increased attention for off-grid and off-shore power generation due to inherent advantages over the more popular horizontal-axis wind turbines (HAWTs). Among these advantages are generator locale, omni-directionality and simplistic design. However, one major disadvantage is lower efficiency, which can be alleviated through blade pitching. Since each blade must transit both up- and down-stream each revolution, VAWT blade pitching techniques are not yet commonplace due to increased complexity and cost. Utilizing passively-morphing flexible blades can offer similar results as active pitching, requiring no sensors or actuators, and has shown promise in increasing VAWT performance in select cases. In this study, wind tunnel tests have been conducted with flexible and rigid-bladed NACA 0012 airfoils, in order to provide necessary input data for a Double-Multiple Stream-Tube (DMST) model. The results from this study indicate that a passively-morphing VAWT can achieve a maximum power coefficient () far exceeding that for a rigid-bladed VAWT (18.9% vs. 10%) with reduced normal force fluctuations as much as 6.9%. Operational range of tip-speed ratio also is observed to increase by a maximum of 40.3%. - Open Access
Thermodynamic Analysis of a High-Temperature Latent Heat Thermal Energy Storage System
Thermal energy storage (TES) technologies are becoming vitally important due to intermittency of renewable energy sources in solar applications. Since high energy density is an important parameter in TES systems, latent heat thermal energy storage (LHTES) system is a common way to store thermal energy. Though there are a great number of experimental studies in the field of LHTES systems, utilizing computational codes can yield relatively quick analyses with relatively small expense. In this study, a numerical investigation of a LHTES system has been studied using ANSYS FLUENT. Results are validated with experiments, using hydroquinone as a phase-change material (PCM), which is external to Therminol VP-1 as a heat transfer fluid (HTF) contained in pipes. Energy efficiency and entropy generation are investigated for different tube/pipe geometries with a constant PCM volume. HTF inlet temperature and flow rate impacts on the thermodynamic efficiencies are examined including viscous dissipation effects. Highest efficiency and lowest entropy generation cases exist when when flow rates are lowest due to low viscous heating effects. A positive relation is found between energy efficiency and volume ratio while it differs for entropy generation for higher and lower velocities. Both efficiency and entropy generation decreased with decreasing HTF inlet temperature. The novelty of this study is the analysis of the effect of volume ratio on system performance and PCM melting time which ultimately proved to be the most dominant factor among those considered herein. However, as PCM solidification and melting time is of primary importance to system designers, simply minimizing entropy generation by decreasing volume ratio in this case does not lead to a practically optimal system, merely to decrease heat transfer entropy generation. Therefore, caution should be taken when applying entropy analyses to any LHTES storage system as entropy minimization methods may not be appropriate for practicality purposes.
Open AccessThermodynamic Analysis of a High-Temperature Latent Heat Thermal Energy Storage System
Thermal energy storage (TES) technologies are becoming vitally important due to intermittency of renewable energy sources in solar applications. Since high energy density is an important parameter in TES systems, latent heat thermal energy storage (LHTES) system is a common way to store thermal energy. Though there are a great number of experimental studies in the field of LHTES systems, utilizing computational codes can yield relatively quick analyses with relatively small expense. In this study, a numerical investigation of a LHTES system has been studied using ANSYS FLUENT. Results are validated with experiments, using hydroquinone as a phase-change material (PCM), which is external to Therminol VP-1 as a heat transfer fluid (HTF) contained in pipes. Energy efficiency and entropy generation are investigated for different tube/pipe geometries with a constant PCM volume. HTF inlet temperature and flow rate impacts on the thermodynamic efficiencies are examined including viscous dissipation effects. Highest efficiency and lowest entropy generation cases exist when when flow rates are lowest due to low viscous heating effects. A positive relation is found between energy efficiency and volume ratio while it differs for entropy generation for higher and lower velocities. Both efficiency and entropy generation decreased with decreasing HTF inlet temperature. The novelty of this study is the analysis of the effect of volume ratio on system performance and PCM melting time which ultimately proved to be the most dominant factor among those considered herein. However, as PCM solidification and melting time is of primary importance to system designers, simply minimizing entropy generation by decreasing volume ratio in this case does not lead to a practically optimal system, merely to decrease heat transfer entropy generation. Therefore, caution should be taken when applying entropy analyses to any LHTES storage system as entropy minimization methods may not be appropriate for practicality purposes.
- Open Access
Performance of Closed Loop Venturi Aspirated Aeration System: Experimental Study and Numerical Analysis with Discrete Bubble Model
In wastewater treatment plants, aeration plays a significant role as it encourages aerobic respiration of microbes, which are necessary to break down carbonaceous matter in the waste stream. This process can account for the majority of energy use in wastewater treatment plants. The aeration process is also necessary in odor control in lagoons and in the aquaculture industry. Generally, the aeration process is accomplished with compressors or blowers which can be of low efficiency due to ideal gas laws. This study introduces the idea of increasing aeration efficiency by looping water from a reservoir through a piping network which includes a venturi aspirator at its inlet. For this purpose, an experimental study has been conducted in a laboratory setup with a pump which pulls water from a tank, passes it through a Venturi aspirator and a helical piping network intended to increase bubble residence time, before depositing it back into the bulk fluid tank. This same process is modeled computationally, using a discrete bubble method (DBM), with good agreement with experiments. The overall purpose here is to determine the optimal configurations for standard aeration efficiency (SAE) and the standard oxygen transfer rate (SOTR). A parametric study has been implemented using the DBM based on different hydraulic and flow parameters. The model is also used to predict the SAE of a hypothetical aeration system. Results indicate that it is possible to achieve SAE values in the range of surface aerators or submersed jet aerators using the proposed aeration system with less complex components, thereby decreasing overall costs.
Open AccessPerformance of Closed Loop Venturi Aspirated Aeration System: Experimental Study and Numerical Analysis with Discrete Bubble Model
In wastewater treatment plants, aeration plays a significant role as it encourages aerobic respiration of microbes, which are necessary to break down carbonaceous matter in the waste stream. This process can account for the majority of energy use in wastewater treatment plants. The aeration process is also necessary in odor control in lagoons and in the aquaculture industry. Generally, the aeration process is accomplished with compressors or blowers which can be of low efficiency due to ideal gas laws. This study introduces the idea of increasing aeration efficiency by looping water from a reservoir through a piping network which includes a venturi aspirator at its inlet. For this purpose, an experimental study has been conducted in a laboratory setup with a pump which pulls water from a tank, passes it through a Venturi aspirator and a helical piping network intended to increase bubble residence time, before depositing it back into the bulk fluid tank. This same process is modeled computationally, using a discrete bubble method (DBM), with good agreement with experiments. The overall purpose here is to determine the optimal configurations for standard aeration efficiency (SAE) and the standard oxygen transfer rate (SOTR). A parametric study has been implemented using the DBM based on different hydraulic and flow parameters. The model is also used to predict the SAE of a hypothetical aeration system. Results indicate that it is possible to achieve SAE values in the range of surface aerators or submersed jet aerators using the proposed aeration system with less complex components, thereby decreasing overall costs.
- 13 March 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 142 (8) , 1-12
Numerical Fluid–Structure Interaction Analysis of a Wells Turbine With Flexible Blades
Direct energy conversion from ocean waves requires some method of rectifying the oscillatory motion to produce a unidirectional output. The Wells turbine accomplishes this with horizontally mounted symmetric blades, which produce a net torque output when combined with an oscillating water column. Previous studies have been conducted, which investigate the effects of blade profile, turbine solidity, stator tip gap clearance, and a number of guide vane designs intended to improve performance. Both experimental and computational methods have been employed, with computational models typically relying on commercially available computational fluid dynamics (CFD) code and assuming steady-state flow conditions. In this work, the open-source code foam-extend is used to study the transient behavior of a Wells turbine, with both a standard rigid blade and a blade with a flexible trailing edge. A validated model is established, and the effects of various Young’s Moduli are tested and their flow fields analyzed. Significant performance gains are realized, with a nearly 17% increase in output torque in some cases.
- 13 March 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 142 (8) , 1-12
Numerical Fluid–Structure Interaction Analysis of a Wells Turbine With Flexible Blades
Direct energy conversion from ocean waves requires some method of rectifying the oscillatory motion to produce a unidirectional output. The Wells turbine accomplishes this with horizontally mounted symmetric blades, which produce a net torque output when combined with an oscillating water column. Previous studies have been conducted, which investigate the effects of blade profile, turbine solidity, stator tip gap clearance, and a number of guide vane designs intended to improve performance. Both experimental and computational methods have been employed, with computational models typically relying on commercially available computational fluid dynamics (CFD) code and assuming steady-state flow conditions. In this work, the open-source code foam-extend is used to study the transient behavior of a Wells turbine, with both a standard rigid blade and a blade with a flexible trailing edge. A validated model is established, and the effects of various Young’s Moduli are tested and their flow fields analyzed. Significant performance gains are realized, with a nearly 17% increase in output torque in some cases.
- 17 December 2018
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (2)
A Numerical Case Study: Effect of Heat Leakage on Thermodynamic Efficiency of Cylinders in Cross-Flow
Numerical and thermodynamic analyses have been undertaken in this study to examine energy and exergy efficiencies of in-line tube banks for unsteady cross-flow. Pitch ratio (PR) and the number of in-line tubes are varied for Reynolds numbers of 500 and 10,000, and artificial heat leakages are modeled as a source term. Numerical results are compared with published values, and good agreements are obtained regarding Nusselt number and pressure drop. Whereas the energy efficiency varied between 72% and 99%, the exergy efficiency ranged from 40% to 70%. It was found that while viscous dissipation has a low effect on energy and exergy efficiencies for the lower Reynolds number, it has a significant effect for the higher Reynolds number. On the other hand, heat leakage had a greater effect on exergy efficiency compared to energy efficiency, especially for the lower Reynolds number case. Overall, this study verified how heat leakage could play a vital role on efficiency for low-inlet temperature heat recovery systems.
- 17 December 2018
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (2)
A Numerical Case Study: Effect of Heat Leakage on Thermodynamic Efficiency of Cylinders in Cross-Flow
Numerical and thermodynamic analyses have been undertaken in this study to examine energy and exergy efficiencies of in-line tube banks for unsteady cross-flow. Pitch ratio (PR) and the number of in-line tubes are varied for Reynolds numbers of 500 and 10,000, and artificial heat leakages are modeled as a source term. Numerical results are compared with published values, and good agreements are obtained regarding Nusselt number and pressure drop. Whereas the energy efficiency varied between 72% and 99%, the exergy efficiency ranged from 40% to 70%. It was found that while viscous dissipation has a low effect on energy and exergy efficiencies for the lower Reynolds number, it has a significant effect for the higher Reynolds number. On the other hand, heat leakage had a greater effect on exergy efficiency compared to energy efficiency, especially for the lower Reynolds number case. Overall, this study verified how heat leakage could play a vital role on efficiency for low-inlet temperature heat recovery systems.