Feifan Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feifan Shen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mingjian Cui
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
2 shared publications Bin Zhang
Senior Engineer, Power Grid Technology Center, Sate Grid Hunan Electric Power Corporation Limited Research Institute, Changsha, Hunan 410007, China
1 shared publication- Bin Zhang
Sate Grid Hunan Electric Power Corporation Research Institute, Changsha 410007, China
1 shared publication - Chen Zhang
School of Electrical Engineering, Wuhan University, Wuhan, Hubei China
1 shared publication - Chi Yung Chung
The Hong Kong Polytechnic University
1 shared publication - Deping Ke
Wuhan University
1 shared publication
Latest Publications
- 1 April 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 144 (2)
Advanced Control of DFIG to Enhance the Transient Voltage Support Capability
This paper presents a novel method to enhance the low-voltage ride-through (LVRT) capability of a doubly fed induction generator (DFIG) equipped with an energy storage system (ESS) to provide voltage support during grid faults. Specifically, the transient DC-link voltage is regulated by controlling the ESS, which is connected to the DC-link capacitor of the DFIG. This is actually equivalent to absorbing the power imbalance between the captured wind power and the power delivered to the grid by the DFIG during the fault so that the DC-link voltage and the rotor current dynamics can be greatly improved. Moreover, both the rotor speed and the pitch angle are also controlled to initially react to the low-voltage transient, which includes increasing rotor speed to store the unbalanced energy as kinetic energy and augmenting the pitch angle to reduce the captured wind power. Thus, because of less unbalanced power flowing into the rotor, the DFIG dynamics can be further improved and the required ESS capacity can be saved. As the grid-side converter (GSC) is not necessarily required to manage the transient DC-link voltage, it is manipulated to devote its entire capacity to injecting reactive power into the grid for voltage support during a fault. Comparisons with the conventional control strategy are obtained by simulating a single machine-infinite bus power system. It is verified that the proposed method can not only ensure the LVRT capability of DFIG by saving the ESS capacity, but also significantly improve the terminal voltage dynamics during the grid fault.
- 1 April 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 144 (2)
Advanced Control of DFIG to Enhance the Transient Voltage Support Capability
This paper presents a novel method to enhance the low-voltage ride-through (LVRT) capability of a doubly fed induction generator (DFIG) equipped with an energy storage system (ESS) to provide voltage support during grid faults. Specifically, the transient DC-link voltage is regulated by controlling the ESS, which is connected to the DC-link capacitor of the DFIG. This is actually equivalent to absorbing the power imbalance between the captured wind power and the power delivered to the grid by the DFIG during the fault so that the DC-link voltage and the rotor current dynamics can be greatly improved. Moreover, both the rotor speed and the pitch angle are also controlled to initially react to the low-voltage transient, which includes increasing rotor speed to store the unbalanced energy as kinetic energy and augmenting the pitch angle to reduce the captured wind power. Thus, because of less unbalanced power flowing into the rotor, the DFIG dynamics can be further improved and the required ESS capacity can be saved. As the grid-side converter (GSC) is not necessarily required to manage the transient DC-link voltage, it is manipulated to devote its entire capacity to injecting reactive power into the grid for voltage support during a fault. Comparisons with the conventional control strategy are obtained by simulating a single machine-infinite bus power system. It is verified that the proposed method can not only ensure the LVRT capability of DFIG by saving the ESS capacity, but also significantly improve the terminal voltage dynamics during the grid fault.
- 10 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 9 (2) , 780-791
Coordinated Supplementary Damping Control of DFIG and PSS to Suppress Inter-Area Oscillations With Optimally Controlled Plant Dynamics
This paper proposes a design method to coordinate dual-channel supplementary damping controllers (SDCs) of doubly-fed induction generators (DFIGs) and power system stabilizers (PSSs) for suppression of inter-area power oscillations. A dynamic performance index is introduced to measure the dynamics of the conventional synchronous generator (SG) and DFIG during the damping control process. Hence, the proposed method designing the PSS and SDC is formulated as an optimization problem with the objective function being the sum of weighted performance indexes and the constraints indicating the requirements on the damping of the inter-area modes. Solving the optimization problem can obtain the optimal SDC and PSS which can meet the required damping results as well as optimize dynamics of the controlled plants. Moreover, by adjusting weights in the objective function, the damping control burden can be flexibly and feasibly allocated between active and reactive power channels of DFIGs or among the damping controllers. Simulations with the modified New England and New York interconnected system prove that the proposed optimization based tuning method can not only robustly coordinate the PSS and SDC to effectively damp inter-area oscillations but also improve the dynamics of controlled plants during the damping control process over different operating conditions.
- 10 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 9 (2) , 780-791
Coordinated Supplementary Damping Control of DFIG and PSS to Suppress Inter-Area Oscillations With Optimally Controlled Plant Dynamics
This paper proposes a design method to coordinate dual-channel supplementary damping controllers (SDCs) of doubly-fed induction generators (DFIGs) and power system stabilizers (PSSs) for suppression of inter-area power oscillations. A dynamic performance index is introduced to measure the dynamics of the conventional synchronous generator (SG) and DFIG during the damping control process. Hence, the proposed method designing the PSS and SDC is formulated as an optimization problem with the objective function being the sum of weighted performance indexes and the constraints indicating the requirements on the damping of the inter-area modes. Solving the optimization problem can obtain the optimal SDC and PSS which can meet the required damping results as well as optimize dynamics of the controlled plants. Moreover, by adjusting weights in the objective function, the damping control burden can be flexibly and feasibly allocated between active and reactive power channels of DFIGs or among the damping controllers. Simulations with the modified New England and New York interconnected system prove that the proposed optimization based tuning method can not only robustly coordinate the PSS and SDC to effectively damp inter-area oscillations but also improve the dynamics of controlled plants during the damping control process over different operating conditions.
- Open Access
Comprehensive Reactive Power Support of DFIG Adapted to Different Depth of Voltage Sags
The low voltage ride-through (LVRT) capability of the doubly-fed induction generator (DFIG) significantly impacts upon the integration of wind power into the power grid. This paper develops a novel comprehensive control strategy to enhance the LVRT and reactive power support capacities of the DFIG by installing the energy storage system (ESS). The ESS is connected to the DC-link capacitor of the DFIG and used to regulate the DC-link voltage during normal or fault operations. The unbalanced power between the captured wind power and the power injected to the grid during the transient process is absorbed or compensated by the ESS. The rotor-side converter (RSC) is used to control the maximum power production and the grid-side converter (GSC) is used to control the reactive power before participating in the voltage support. When the supply voltage continues to drop, the rotor speed is increased by controlling the RSC to realize the LVRT capability and help the GSC further enhance the reactive power support capability. The capacity of the GSC is dedicated to injecting the reactive power to the grid. An auxiliary transient pitch angle controller is proposed to protect the generator’s over speed. Both RSC and GSC act as reactive power sources to further enhance the voltage support capability with serious voltage sags. Simulations based on a single-machine infinite-bus power system verify the effectiveness of the developed comprehensive control strategy.
Open AccessComprehensive Reactive Power Support of DFIG Adapted to Different Depth of Voltage Sags
The low voltage ride-through (LVRT) capability of the doubly-fed induction generator (DFIG) significantly impacts upon the integration of wind power into the power grid. This paper develops a novel comprehensive control strategy to enhance the LVRT and reactive power support capacities of the DFIG by installing the energy storage system (ESS). The ESS is connected to the DC-link capacitor of the DFIG and used to regulate the DC-link voltage during normal or fault operations. The unbalanced power between the captured wind power and the power injected to the grid during the transient process is absorbed or compensated by the ESS. The rotor-side converter (RSC) is used to control the maximum power production and the grid-side converter (GSC) is used to control the reactive power before participating in the voltage support. When the supply voltage continues to drop, the rotor speed is increased by controlling the RSC to realize the LVRT capability and help the GSC further enhance the reactive power support capability. The capacity of the GSC is dedicated to injecting the reactive power to the grid. An auxiliary transient pitch angle controller is proposed to protect the generator’s over speed. Both RSC and GSC act as reactive power sources to further enhance the voltage support capability with serious voltage sags. Simulations based on a single-machine infinite-bus power system verify the effectiveness of the developed comprehensive control strategy.