Amanda M. Murray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Amanda M. Murray has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Grant E. Norte
University of Central Florida
5 shared publications - David Matthew Bazett-Jones
The University of Toledo
4 shared publications - Cory L. Christiansen
Bone‐Anchored Limb Research Group University of Colorado Anschutz Medical Campus Aurora Colorado USA
3 shared publications - Justin L. Rush
Department of Exercise and Rehabilitation Sciences, University of Toledo, Toledo, OH, USA; Division of Physical Therapy, School of Rehabilitation and Communication Sciences, College of Health Sciences and Professions, Ohio University, Athens, OH, USA; Ohio Musculoskeletal & Neurological Institute, Ohio University, Athens, OH, 45701, USA
3 shared publications - Brecca M. M. Gaffney
Department of Mechanical Engineering, University of Colorado Denver, Denver, CO, USA
2 shared publications - Neal Robert Glaviano
Department of Kinesiology, University of Connecticut, Storrs, CT, USA
2 shared publications
Latest Publications
- 5 May 2025
- Published by Elsevier in Physical Therapy in Sport
- Vol. 74, 18-24
Examining neurocognitive profiles and single-limb landing mechanics following anterior cruciate ligament reconstruction
- 5 May 2025
- Published by Elsevier in Physical Therapy in Sport
- Vol. 74, 18-24
Examining neurocognitive profiles and single-limb landing mechanics following anterior cruciate ligament reconstruction
- 25 February 2025
- Published by Elsevier in Physical Therapy in Sport
- Vol. 72, 109-115
Kinesiophobia is associated with lower extremity landing biomechanics in individuals with ACL reconstruction
- 25 February 2025
- Published by Elsevier in Physical Therapy in Sport
- Vol. 72, 109-115
Kinesiophobia is associated with lower extremity landing biomechanics in individuals with ACL reconstruction
- 1 January 2025
- Published by National Athletic Trainers' Association in Journal of Athletic Training
- Vol. 60 (1) , 21-28
Cognitive-Motor Dual-Task Performance of the Landing Error Scoring System
Context: The Landing Error Scoring System (LESS) is a common assessment used to determine biomechanical landing errors. However, this assessment is completed as a single motor task, which does not require additional attentional resources. It is unclear if the LESS can be used to detect cognitive-motor interference (ie, dual-task cost) in biomechanical errors associated with lower extremity injury. Objective: To determine if the LESS is a suitable clinical assessment of dual-task performance in uninjured women and to evaluate whether specific landing criteria are more affected by an additional cognitive load than others. Design: Cross-sectional study. Setting: University research laboratory. Patients or Other Participants: A total of 20 uninjured, physically active female participants (age = 22.4 ± 2.5 years, height = 1.68 ± 0.07 m, mass = 67.0 ± 13.8 kg, Tegner Activity Scale = 5.9 ± 1.1). Intervention(s): Participants performed the LESS under 3 different conditions: baseline landing with no cognitive distraction (Single), a visual-based dual task (Visual), and a number-based dual task (Number). Main Outcome Measures(s): Mean sagittal-plane, frontal-plane, and total LESS scores were compared between conditions using a 1-way repeated-measures analysis of variance with Tukey post hoc correction. A Cohen d effect size with a 95% confidence interval was used to determine the magnitude of differences. The frequency of errors for each LESS item under the 3 conditions was compared using χ2 analysis. Results: Participants exhibited greater sagittal-plane (P = .02, d = 0.91; 95% confidence interval, 0.26–1.56) and total (P = .008, d = 1.03; 95% confidence interval, 0.37–1.69) errors during the Visual condition than during the Single condition. The frequency of errors observed for each LESS item did not differ between conditions (all P > .05). Conclusions: The LESS was able to detect a dual-task cost in landing errors during both the Visual conditions. We recommend developing clinically oriented solutions to incorporate similar dual-task paradigms in traditional injury risk-reduction programs.
- 1 January 2025
- Published by National Athletic Trainers' Association in Journal of Athletic Training
- Vol. 60 (1) , 21-28
Cognitive-Motor Dual-Task Performance of the Landing Error Scoring System
Context: The Landing Error Scoring System (LESS) is a common assessment used to determine biomechanical landing errors. However, this assessment is completed as a single motor task, which does not require additional attentional resources. It is unclear if the LESS can be used to detect cognitive-motor interference (ie, dual-task cost) in biomechanical errors associated with lower extremity injury. Objective: To determine if the LESS is a suitable clinical assessment of dual-task performance in uninjured women and to evaluate whether specific landing criteria are more affected by an additional cognitive load than others. Design: Cross-sectional study. Setting: University research laboratory. Patients or Other Participants: A total of 20 uninjured, physically active female participants (age = 22.4 ± 2.5 years, height = 1.68 ± 0.07 m, mass = 67.0 ± 13.8 kg, Tegner Activity Scale = 5.9 ± 1.1). Intervention(s): Participants performed the LESS under 3 different conditions: baseline landing with no cognitive distraction (Single), a visual-based dual task (Visual), and a number-based dual task (Number). Main Outcome Measures(s): Mean sagittal-plane, frontal-plane, and total LESS scores were compared between conditions using a 1-way repeated-measures analysis of variance with Tukey post hoc correction. A Cohen d effect size with a 95% confidence interval was used to determine the magnitude of differences. The frequency of errors for each LESS item under the 3 conditions was compared using χ2 analysis. Results: Participants exhibited greater sagittal-plane (P = .02, d = 0.91; 95% confidence interval, 0.26–1.56) and total (P = .008, d = 1.03; 95% confidence interval, 0.37–1.69) errors during the Visual condition than during the Single condition. The frequency of errors observed for each LESS item did not differ between conditions (all P > .05). Conclusions: The LESS was able to detect a dual-task cost in landing errors during both the Visual conditions. We recommend developing clinically oriented solutions to incorporate similar dual-task paradigms in traditional injury risk-reduction programs.
- 1 July 2021
- Published by Elsevier in Gait & Posture
- Vol. 88, 138-145
Sex influences the relationship between hamstrings-to-quadriceps strength imbalance and co-activation during walking gait
- 1 July 2021
- Published by Elsevier in Gait & Posture
- Vol. 88, 138-145
Sex influences the relationship between hamstrings-to-quadriceps strength imbalance and co-activation during walking gait
- 1 December 2020
- Published by Elsevier in Human Movement Science
- Vol. 74, 102719
Restricting ankle dorsiflexion does not mitigate the benefits of external focus of attention on landing biomechanics in healthy females
- 1 December 2020
- Published by Elsevier in Human Movement Science
- Vol. 74, 102719
Restricting ankle dorsiflexion does not mitigate the benefits of external focus of attention on landing biomechanics in healthy females
- 7 July 2020
- Published by Elsevier in Clinical Biomechanics
- Vol. 80, 105102
Movement asymmetry during low and high demand mobility tasks after dysvascular transtibial amputation
- 7 July 2020
- Published by Elsevier in Clinical Biomechanics
- Vol. 80, 105102
Movement asymmetry during low and high demand mobility tasks after dysvascular transtibial amputation
- 31 May 2020
- Published by Elsevier in Gait & Posture
- Vol. 80, 162-167
Step length symmetry adaptation to split-belt treadmill walking after acquired non-traumatic transtibial amputation
- 31 May 2020
- Published by Elsevier in Gait & Posture
- Vol. 80, 162-167
Step length symmetry adaptation to split-belt treadmill walking after acquired non-traumatic transtibial amputation
- 1 November 2017
- Published by Elsevier in Clinical Biomechanics
- Vol. 49, 64-71
Biomechanical compensations of the trunk and lower extremities during stepping tasks after unilateral transtibial amputation
- 1 November 2017
- Published by Elsevier in Clinical Biomechanics
- Vol. 49, 64-71
Biomechanical compensations of the trunk and lower extremities during stepping tasks after unilateral transtibial amputation
- 1 September 2017
- Published by ASME International in Journal of Verification, Validation and Uncertainty Quantification
- Vol. 2 (3) , 031003-1-031003-8
The Effects of Prosthesis Inertial Parameters on Inverse Dynamics: A Probabilistic Analysis
Joint kinetic measurement is a fundamental tool used to quantify compensatory movement patterns in participants with transtibial amputation (TTA). Joint kinetics are calculated through inverse dynamics (ID) and depend on segment kinematics, external forces, and both segment and prosthetic inertial parameters (PIPS); yet the individual influence of PIPs on ID is unknown. The objective of this investigation was to assess the importance of parameterizing PIPs when calculating ID using a probabilistic analysis. A series of Monte Carlo simulations were performed to assess the influence of uncertainty in PIPs on ID. Multivariate input distributions were generated from experimentally measured PIPs (foot/shank: mass, center of mass (COM), moment of inertia) of ten prostheses and output distributions were hip and knee joint kinetics. Confidence bounds (2.5–97.5%) and sensitivity of outputs to model input parameters were calculated throughout one gait cycle. Results demonstrated that PIPs had a larger influence on joint kinetics during the swing period than the stance period (e.g., maximum hip flexion/extension moment confidence bound size: stance = 5.6 N·m, swing: 11.4 N·m). Joint kinetics were most sensitive to shank mass during both the stance and swing periods. Accurate measurement of prosthesis shank mass is necessary to calculate joint kinetics with ID in participants with TTA with passive prostheses consisting of total contact carbon fiber sockets and dynamic elastic response feet during walking.
- 1 September 2017
- Published by ASME International in Journal of Verification, Validation and Uncertainty Quantification
- Vol. 2 (3) , 031003-1-031003-8
The Effects of Prosthesis Inertial Parameters on Inverse Dynamics: A Probabilistic Analysis
Joint kinetic measurement is a fundamental tool used to quantify compensatory movement patterns in participants with transtibial amputation (TTA). Joint kinetics are calculated through inverse dynamics (ID) and depend on segment kinematics, external forces, and both segment and prosthetic inertial parameters (PIPS); yet the individual influence of PIPs on ID is unknown. The objective of this investigation was to assess the importance of parameterizing PIPs when calculating ID using a probabilistic analysis. A series of Monte Carlo simulations were performed to assess the influence of uncertainty in PIPs on ID. Multivariate input distributions were generated from experimentally measured PIPs (foot/shank: mass, center of mass (COM), moment of inertia) of ten prostheses and output distributions were hip and knee joint kinetics. Confidence bounds (2.5–97.5%) and sensitivity of outputs to model input parameters were calculated throughout one gait cycle. Results demonstrated that PIPs had a larger influence on joint kinetics during the swing period than the stance period (e.g., maximum hip flexion/extension moment confidence bound size: stance = 5.6 N·m, swing: 11.4 N·m). Joint kinetics were most sensitive to shank mass during both the stance and swing periods. Accurate measurement of prosthesis shank mass is necessary to calculate joint kinetics with ID in participants with TTA with passive prostheses consisting of total contact carbon fiber sockets and dynamic elastic response feet during walking.