Dejan Vernon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dejan Vernon has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Ana Mijic
Department of Civil and Environmental Engineering, Imperial College London, London SW7 2AZ, UK
2 shared publications - Mohamad H. El Hattab
Department of Civil and Environmental Engineering, Imperial College London, London SW7 2AZ, UK
2 shared publications
Latest Publications
- Open Access
Optimised Triangular Weir Design for Assessing the Full-Scale Performance of Green Infrastructure
Conventional triangular weirs have been originally developed to measure, divert, and control surface water. However, a special application of these weirs, such as for low flow measurements in full-scale monitoring of Green Infrastructure (GI), is not well investigated. Available head-discharge relationships for triangular sharp-crested weirs are only valid under a free-flow regime. Literature focusing on the V-notch weir usage for GI assessment suggests that it is necessary to calibrate the head-discharge relationship before its use. This study focuses on understanding the effects of site constraints on the measurement performance of a V-notch weir at low flow rates, and the validity of equations derived for similar applications that can be found in the literature. The variation of discharge coefficient in various flow regimes was investigated experimentally based on calibration runs covering flow rates between 0.054 l/s and 7 l/s. The results show that for 30° and 45° V-notch weirs, three flow regimes can be identified. It was observed that literature equations to calculate the discharge coefficient are valid for partially-contracted triangular weirs only at heads greater than vertex distance from the channel. However, for low flows that are expected to occur when estimating the full-scale performance of GI, the equations available from the literature for similar site conditions underestimated the flow rate between 85% and 17%. This emphasises the need for accurate calibration of a V-notch device under the site conditions to achieve the necessary level of accuracy in GI performance estimation. The procedure outlined in this work can be easily replicated to determine the optimal monitoring system configuration. Alternatively, if the site conditions would match those described in this study, the computed discharge using the proposed relations, in combination with the general V-notch weir equation, provides a significant improvement in the accuracy of measurements, expands the head applicability range of V-notch weirs, and enables better understanding of GI performance at the full scale.
Open AccessOptimised Triangular Weir Design for Assessing the Full-Scale Performance of Green Infrastructure
Conventional triangular weirs have been originally developed to measure, divert, and control surface water. However, a special application of these weirs, such as for low flow measurements in full-scale monitoring of Green Infrastructure (GI), is not well investigated. Available head-discharge relationships for triangular sharp-crested weirs are only valid under a free-flow regime. Literature focusing on the V-notch weir usage for GI assessment suggests that it is necessary to calibrate the head-discharge relationship before its use. This study focuses on understanding the effects of site constraints on the measurement performance of a V-notch weir at low flow rates, and the validity of equations derived for similar applications that can be found in the literature. The variation of discharge coefficient in various flow regimes was investigated experimentally based on calibration runs covering flow rates between 0.054 l/s and 7 l/s. The results show that for 30° and 45° V-notch weirs, three flow regimes can be identified. It was observed that literature equations to calculate the discharge coefficient are valid for partially-contracted triangular weirs only at heads greater than vertex distance from the channel. However, for low flows that are expected to occur when estimating the full-scale performance of GI, the equations available from the literature for similar site conditions underestimated the flow rate between 85% and 17%. This emphasises the need for accurate calibration of a V-notch device under the site conditions to achieve the necessary level of accuracy in GI performance estimation. The procedure outlined in this work can be easily replicated to determine the optimal monitoring system configuration. Alternatively, if the site conditions would match those described in this study, the computed discharge using the proposed relations, in combination with the general V-notch weir equation, provides a significant improvement in the accuracy of measurements, expands the head applicability range of V-notch weirs, and enables better understanding of GI performance at the full scale.
- 24 October 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 282-294
Performance Evaluation of Retrofitted Low Impact Development Practices in Urban Environments: A Case Study from London, U.K.
Low impact development practices (LID), or what are known as sustainable urban drainage systems (SuDS) in the U.K., are expected to have a synergetic effect with the existing infrastructure to mitigate urban storm-water flooding. Designing and implementing effective LID practices require reliable full-scale data about their performance in different applications over an extended period of time; however, relatively few examples of LID practices have been monitored to provide such information. This study developed an innovative micro-monitoring system to assess the performance of porous pavement and rain gardens as retrofitting technologies. The system includes the installation of a V-notch weir at the outlet of each LID device to provide an accurate and reliable quantification of a wide range of discharges. In addition, a low flow sensor is installed downstream to check the readings. Extensive laboratory calibrations under different flows depicting the exact site conditions were performed. The micro-monitoring system is well suited for high-resolution temporal monitoring and enables accurate long-term evaluation of LID components’ performance.
- 24 October 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 282-294
Performance Evaluation of Retrofitted Low Impact Development Practices in Urban Environments: A Case Study from London, U.K.
Low impact development practices (LID), or what are known as sustainable urban drainage systems (SuDS) in the U.K., are expected to have a synergetic effect with the existing infrastructure to mitigate urban storm-water flooding. Designing and implementing effective LID practices require reliable full-scale data about their performance in different applications over an extended period of time; however, relatively few examples of LID practices have been monitored to provide such information. This study developed an innovative micro-monitoring system to assess the performance of porous pavement and rain gardens as retrofitting technologies. The system includes the installation of a V-notch weir at the outlet of each LID device to provide an accurate and reliable quantification of a wide range of discharges. In addition, a low flow sensor is installed downstream to check the readings. Extensive laboratory calibrations under different flows depicting the exact site conditions were performed. The micro-monitoring system is well suited for high-resolution temporal monitoring and enables accurate long-term evaluation of LID components’ performance.