Slaven Kincic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Slaven Kincic has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
A. Chandra
École de technologie supérieure, Montréal, Canada
1 shared publication- Abhishek Somani
Pacific Northwest National Laboratory, Richland, WA, USA
1 shared publication - Alexander A. Anderson
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
1 shared publication - Alison Ha Colotelo
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
1 shared publication - Antos Cheeramban Varghese
School of Electrical, Computer, and Energy Engineering, Arizona State University, Tempe, AZ, USA
1 shared publication B.T. Ooi
Dept. of Electr. Eng., Univ. du Quebec, Quebec City, Canada
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 119578-119591
Oscillations in Hydropower-Rich Power Grids: Characterizing Risks, Causes, and Impacts
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 119578-119591
Open AccessOscillations in Hydropower-Rich Power Grids: Characterizing Risks, Causes, and Impacts
- Open Access
- 5 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 109689-109707
Human-Centric Contingency Analysis Metrics for Evaluating Operator Performance and Trust
A novel set of system-state and control-action penalty functions are introduced as an alternative to traditional performance index contingency ranking. The novel system state penalty metrics are formulated based on piecewise linear functions of the system voltage and branch flow, guided by Weber’s Law of human cognition. Novel continuous and discrete control action metrics are also developed to measure the inherent cost and risk associated with every action taken by human power system operator to resolve violations on a pre-contingent basis. These new metrics are combined with traditional human factors indices for measuring human-machine trust and cognitive workload to create a systematic framework for measuring and evaluating operator trust and reliance on artificial intelligence (AI) algorithms for control room use. An existing AI-based contingency analysis recommender tool using a semi-supervised action algorithm is selected for a series of experiments with operations engineering staff using the IEEE 118 Bus System. The penalty metrics presented are demonstrated for both steady-state contingency analysis and transient stability studies, with the operations participants able to reduce the total system penalty in 85% of scenarios through remedial actions. A human-machine team was able to achieve equal or lower continuous control action penalty scores than the participant without availability of the recommender in 57% of experiment scenarios and lower continuous control action penalty scores than the AI tool alone in 83% of scenarios.
- 5 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 109689-109707
Open AccessHuman-Centric Contingency Analysis Metrics for Evaluating Operator Performance and Trust
A novel set of system-state and control-action penalty functions are introduced as an alternative to traditional performance index contingency ranking. The novel system state penalty metrics are formulated based on piecewise linear functions of the system voltage and branch flow, guided by Weber’s Law of human cognition. Novel continuous and discrete control action metrics are also developed to measure the inherent cost and risk associated with every action taken by human power system operator to resolve violations on a pre-contingent basis. These new metrics are combined with traditional human factors indices for measuring human-machine trust and cognitive workload to create a systematic framework for measuring and evaluating operator trust and reliance on artificial intelligence (AI) algorithms for control room use. An existing AI-based contingency analysis recommender tool using a semi-supervised action algorithm is selected for a series of experiments with operations engineering staff using the IEEE 118 Bus System. The penalty metrics presented are demonstrated for both steady-state contingency analysis and transient stability studies, with the operations participants able to reduce the total system penalty in 85% of scenarios through remedial actions. A human-machine team was able to achieve equal or lower continuous control action penalty scores than the participant without availability of the recommender in 57% of experiment scenarios and lower continuous control action penalty scores than the AI tool alone in 83% of scenarios.
- Open Access
- 1 October 2021
- Published by Office of Scientific and Technical Information (OSTI)
Hydropower’s Contributions to Grid Reliability and Resilience
This is the final report from the project. The report presents results from data and simulation based analyses of hydropower resources' contributions to grid reliability and resilience.
- 1 October 2021
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessHydropower’s Contributions to Grid Reliability and Resilience
This is the final report from the project. The report presents results from data and simulation based analyses of hydropower resources' contributions to grid reliability and resilience.
- 14 November 2020
- Published by Springer Nature
- p. 391-421
Bringing EMS Node-Breaker Model into Offline Planning Tools
- 14 November 2020
- Published by Springer Nature
- p. 391-421
Bringing EMS Node-Breaker Model into Offline Planning Tools
- 30 May 2018
- Published by Springer Nature
- p. 433-447
Model Validation Using Synchrophasor Technology
- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (3) , 2895-2905
Calibrating Parameters of Power System Stability Models Using Advanced Ensemble Kalman Filter
With the ever increasing penetration of renewable energy, smart loads, energy storage, and new market behavior, today's power grid becomes more dynamic and stochastic, which may invalidate traditional study assumptions and pose great operational challenges. Thus, it is of critical importance to maintain good-quality models for secure and economic planning and real-time operation. Following the 1996 Western Systems Coordinating Council system blackout, North American Electric Reliability Corporation (NERC) and Western Electricity Coordinating Council (WECC) in North America enforced a number of policies and standards to guide the power industry to periodically validate power grid models and calibrate poor parameters with the goal of building sufficient confidence in model quality. The PMU-based approach using online measurements without interfering with the operation of generators provides a low-cost alternative to meet NERC standards. This paper presents an innovative procedure and tool suites to validate and calibrate models based on a trajectory sensitivity analysis method and an advanced ensemble Kalman filter algorithm. The developed prototype demonstrates excellent performance in identifying and calibrating bad parameters of a realistic hydro power plant against multiple system events.
- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (3) , 2895-2905
Calibrating Parameters of Power System Stability Models Using Advanced Ensemble Kalman Filter
With the ever increasing penetration of renewable energy, smart loads, energy storage, and new market behavior, today's power grid becomes more dynamic and stochastic, which may invalidate traditional study assumptions and pose great operational challenges. Thus, it is of critical importance to maintain good-quality models for secure and economic planning and real-time operation. Following the 1996 Western Systems Coordinating Council system blackout, North American Electric Reliability Corporation (NERC) and Western Electricity Coordinating Council (WECC) in North America enforced a number of policies and standards to guide the power industry to periodically validate power grid models and calibrate poor parameters with the goal of building sufficient confidence in model quality. The PMU-based approach using online measurements without interfering with the operation of generators provides a low-cost alternative to meet NERC standards. This paper presents an innovative procedure and tool suites to validate and calibrate models based on a trajectory sensitivity analysis method and an advanced ensemble Kalman filter algorithm. The developed prototype demonstrates excellent performance in identifying and calibrating bad parameters of a realistic hydro power plant against multiple system events.
- 1 January 2006
- Published by Institution of Engineering and Technology (IET) in IEE Proceedings - Generation, Transmission and Distribution
- Vol. 153 (1) , 51
Voltage support of radial transmission lines by var compensation at distribution buses
- 1 January 2006
- Published by Institution of Engineering and Technology (IET) in IEE Proceedings - Generation, Transmission and Distribution
- Vol. 153 (1) , 51
Voltage support of radial transmission lines by var compensation at distribution buses