Xingchen Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingchen Yang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Honghai Liu
Harbin Institute of Technology (Shenzhen)
3 shared publications - Jipeng Yan
Ultrasound Lab for Imaging and Sensing, Department of Bioengineering, Imperial College London, London, UK
2 shared publications - Dalin Zhou
University of Portsmouth
1 shared publication - Han Ding
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication - Youjia Huang
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai Jiao Tong University, 12474 Shanghai China 200240
1 shared publication - Yu Zhou
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication
Latest Publications
- 27 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (9) , 2434-2442
Comparative Analysis of Wearable A-Mode Ultrasound and sEMG for Muscle-Computer Interface
Objective: While surface electromyography (sEMG) is still dominant in the field of muscle-computer interface, ultrasound (US) sensing has been regarded as a promising alternative to sEMG, owing to its ability to precisely monitor muscle deformations. Among different US modalities, A-mode US is more compact and cost-effective for wearable applications against its cumbersome B-mode counterpart. In this work, we conduct a comprehensive comparison of wearable A-mode US and sEMG on gesture recognition and isometric muscle contraction force estimation. Methods: We experimented with eight types of gesture, with a range of 0-60% maximum voluntary contraction for each motion. Results: Results show that A-mode US outperforms sEMG on gesture recognition accuracy, robustness, and discrete force estimation accuracy, while sEMG is superior to US on continuous force estimation accuracy and ease of use in force estimation. Moreover, an extended online experiment demonstrates that the complementary advantages of US and sEMG on gesture recognition and continuous force estimation can be combined for the achievement of multi-class proportional gesture control. Significance: This study demonstrates the potential of A-mode US in automated gesture recognition, and the prospect of sEMG/US fusion for proportional gesture interaction.
- 27 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (9) , 2434-2442
Comparative Analysis of Wearable A-Mode Ultrasound and sEMG for Muscle-Computer Interface
Objective: While surface electromyography (sEMG) is still dominant in the field of muscle-computer interface, ultrasound (US) sensing has been regarded as a promising alternative to sEMG, owing to its ability to precisely monitor muscle deformations. Among different US modalities, A-mode US is more compact and cost-effective for wearable applications against its cumbersome B-mode counterpart. In this work, we conduct a comprehensive comparison of wearable A-mode US and sEMG on gesture recognition and isometric muscle contraction force estimation. Methods: We experimented with eight types of gesture, with a range of 0-60% maximum voluntary contraction for each motion. Results: Results show that A-mode US outperforms sEMG on gesture recognition accuracy, robustness, and discrete force estimation accuracy, while sEMG is superior to US on continuous force estimation accuracy and ease of use in force estimation. Moreover, an extended online experiment demonstrates that the complementary advantages of US and sEMG on gesture recognition and continuous force estimation can be combined for the achievement of multi-class proportional gesture control. Significance: This study demonstrates the potential of A-mode US in automated gesture recognition, and the prospect of sEMG/US fusion for proportional gesture interaction.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (1) , 800-808
A Proportional Pattern Recognition Control Scheme for Wearable A-mode Ultrasound Sensing
It is evident that the prevailing solution, myoelectric pattern recognition for prosthetic manipulation, constrains gesture-based interaction due to the lack of proportional control information such as exerted force. This paper reports an attempt, named simultaneous gesture recognition and muscle contraction force estimation, to realize proportional pattern recognition (PPR) control taking advantage of arm muscle deformation via wearable ultrasound sensing. We experiment with eight types of predefined hand motions, with a range of 0 - 60% maximum voluntary contraction (MVC) using a wearable multi-channel Amode ultrasound system. The experimental result demonstrates that above 93.7% of gestures are correctly recognized during dynamic muscle contraction forces (0 - 60% MVC), albeit only training at a slight force level (<6% MVC). Besides, the adopted non-parametric Gaussian process regression estimates the muscle contraction forces accurately synchronously, with average coefficient of determination ( $\mathbf{R}^2$ ) and normalized root-mean-square error (nRMSE) of 0.927 and 0.102, respectively. These research outcomes demonstrate the feasibility of ultrasound-based PPR control, paving the way for musculature-driven applications including finer prosthetic control, remote manipulation and rehabilitation treatment.- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (1) , 800-808
A Proportional Pattern Recognition Control Scheme for Wearable A-mode Ultrasound Sensing
It is evident that the prevailing solution, myoelectric pattern recognition for prosthetic manipulation, constrains gesture-based interaction due to the lack of proportional control information such as exerted force. This paper reports an attempt, named simultaneous gesture recognition and muscle contraction force estimation, to realize proportional pattern recognition (PPR) control taking advantage of arm muscle deformation via wearable ultrasound sensing. We experiment with eight types of predefined hand motions, with a range of 0 - 60% maximum voluntary contraction (MVC) using a wearable multi-channel Amode ultrasound system. The experimental result demonstrates that above 93.7% of gestures are correctly recognized during dynamic muscle contraction forces (0 - 60% MVC), albeit only training at a slight force level (<6% MVC). Besides, the adopted non-parametric Gaussian process regression estimates the muscle contraction forces accurately synchronously, with average coefficient of determination ( $\mathbf{R}^2$ ) and normalized root-mean-square error (nRMSE) of 0.927 and 0.102, respectively. These research outcomes demonstrate the feasibility of ultrasound-based PPR control, paving the way for musculature-driven applications including finer prosthetic control, remote manipulation and rehabilitation treatment.- 28 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (4) , 1639-1646
Towards Zero Re-Training for Long-Term Hand Gesture Recognition via Ultrasound Sensing
While myoelectric pattern recognition is a prevailing way for gesture recognition, the inherent nonstationarity of electromyography signals hinders its long-term application. This study aims to prove a hypothesis that morphological information of muscle contraction detected by ultrasound image is potentially suitable for long-term use. A set of ultrasound-based algorithms are proposed to realize robust hand gesture recognition over multiple days, with user training only at the first day. A markerless calibration algorithm is first presented to position the ultrasound probe during donning and doffing; an algorithm combining speeded-up robust features (SURF) and bag-of-features (BoF) model being immune to ultrasound probe shift and rotation is then introduced; a self-enhancing classification method is next adopted to update classification model automatically by incorporating useful knowledge from testing data; finally the performance of long-term hand gesture recognition with zero re-training is validated by a six-day experiment of six healthy subjects, whose outcomes strongly support the hypothesis with about 94% of gesture recognition accuracy for each testing day. This study confirms the feasibility of adoption of ultrasound sensing for long-term musculature related applications.
- 28 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (4) , 1639-1646
Towards Zero Re-Training for Long-Term Hand Gesture Recognition via Ultrasound Sensing
While myoelectric pattern recognition is a prevailing way for gesture recognition, the inherent nonstationarity of electromyography signals hinders its long-term application. This study aims to prove a hypothesis that morphological information of muscle contraction detected by ultrasound image is potentially suitable for long-term use. A set of ultrasound-based algorithms are proposed to realize robust hand gesture recognition over multiple days, with user training only at the first day. A markerless calibration algorithm is first presented to position the ultrasound probe during donning and doffing; an algorithm combining speeded-up robust features (SURF) and bag-of-features (BoF) model being immune to ultrasound probe shift and rotation is then introduced; a self-enhancing classification method is next adopted to update classification model automatically by incorporating useful knowledge from testing data; finally the performance of long-term hand gesture recognition with zero re-training is validated by a six-day experiment of six healthy subjects, whose outcomes strongly support the hypothesis with about 94% of gesture recognition accuracy for each testing day. This study confirms the feasibility of adoption of ultrasound sensing for long-term musculature related applications.