Paolo Di Benedetto
Paolo Di Benedetto has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Araldo Causero
Clinic of Orthopedics, Academic Hospital of Udine, Udine, Italy
11 shared publicationsVanni Cainero
Clinic of Orthopedics, Academic Hospital of Udine, Udine, Italy
10 shared publicationsAlessandro Beltrame
Clinic of Orthopaedics, University Hospital of Udine, Italy
8 shared publicationsRenato Gisonni
Clinic of Orthopedics, Academic Hospital of Udine, Udine, Italy
7 shared publicationsStefano Magnanelli
Clinic of Orthopedics, Academic Hospital of Udine, Udine, Italy
4 shared publicationsGiuseppe Niccoli
3 shared publications
Latest Publications
- 23 June 2023
- Vol. 94 (S2) , e2023092
The current treatment of hip arthroplasty revision: a systematic review of the literature.
Acetabular revision surgery is the most challenging aspect in hip prosthetic. There is lack of consensus on the optimal method of reconstructing the acetabular defects. The aim of this systematic review is to take stock of the state of the art on the options available and highlight which type of construct is the most reliable in usual clinical practice. The reporting of this systematic review was guided by the standards of the Preferred Reporting Items for Systematic Review and Meta-Analysis 2020 Statement.Electronic search of MEDLINE was performed from 1991 up to April 2021 to identify relevant studies for this review. Discussion: various surgical techniques have been adopted and proposed to treat acetabular bone defects: cemented cups, large-sized non-cemented acetabular cups, higher positioned cups, reinforcement rings, cage, oblong cups, custom triflange implants, high porous metal cups and augments. Bone defect defines the type of components to be implanted and among those, outcomes are various depending on the study taken into account, the component used and the degree of initial bone defect. In acetabular revision surgerythe use of TM cups and augment is a valid option in presence of major bone loss and pelvic discontinuities. In clinical practice the use of TM components replaced rings, while the cup-cage implant replaced conventional cages. TM augments and cups can be considered as the most promising technique in the reconstruction of wide acetabular defects, while the use of cages can be considered as a valid option in the elderly population.
- 23 June 2023
- Vol. 94 (S2) , e2023092
The current treatment of hip arthroplasty revision: a systematic review of the literature.
Acetabular revision surgery is the most challenging aspect in hip prosthetic. There is lack of consensus on the optimal method of reconstructing the acetabular defects. The aim of this systematic review is to take stock of the state of the art on the options available and highlight which type of construct is the most reliable in usual clinical practice. The reporting of this systematic review was guided by the standards of the Preferred Reporting Items for Systematic Review and Meta-Analysis 2020 Statement.Electronic search of MEDLINE was performed from 1991 up to April 2021 to identify relevant studies for this review. Discussion: various surgical techniques have been adopted and proposed to treat acetabular bone defects: cemented cups, large-sized non-cemented acetabular cups, higher positioned cups, reinforcement rings, cage, oblong cups, custom triflange implants, high porous metal cups and augments. Bone defect defines the type of components to be implanted and among those, outcomes are various depending on the study taken into account, the component used and the degree of initial bone defect. In acetabular revision surgerythe use of TM cups and augment is a valid option in presence of major bone loss and pelvic discontinuities. In clinical practice the use of TM components replaced rings, while the cup-cage implant replaced conventional cages. TM augments and cups can be considered as the most promising technique in the reconstruction of wide acetabular defects, while the use of cages can be considered as a valid option in the elderly population.
- Open Access
- 5 December 2019
- Vol. 90 (12-S) , 43-47
Leukocyte esterase strip test as a reliable intraoperative PJIs biomarker. Our experience.
Ackgroud and aim of work: Prosthetic joint infection (PJI) is the most common cause of total knee replacement failure and the third most common cause of total hip replacement failure, accounting for 16.8% of all knee revisions and 14.8% of the hip revisions; nevertheless, the diagnosis of PJI is often a challenge for the orthopaedic surgeon. The aim of these study was to evaluate the reliability of the LE strip test for diagnosis of PJI. From December 2016 to January 2019, we enrolled 50 patients with suspected PJI; 32 females and 18 males, the average age at the time of the surgery was 76 years. Twenty-four patients underwent knee revision surgery and twenty-six hip revision surgery. In all patients during the surgery, the synovial fluid was aspirated and used for leukocyte esterase strip test. The result of the tests was compared to periprosthetic tissues culture, histological examination and sonication fluid culture for PJI. Comparing the results obtained from the LE test with the results obtained from the other diagnostic methods, we found that the concordance between the results of the leukocyte-esterase test and those of the culture test with peri-prosthetic tissue or synovial fluid was shown to be 93%, between LE and histological examinations, the concordance was 93% and finally with the culture of the sonicated fluid the concordance was 86% of the cases. The results of our serie show a good intraoperative diagnostic accuracy of the LE test, especially in its ability to exclude the hypothesis of periprosthetic infection in case of a negative result.
- 5 December 2019
- Vol. 90 (12-S) , 43-47
Open AccessLeukocyte esterase strip test as a reliable intraoperative PJIs biomarker. Our experience.
Ackgroud and aim of work: Prosthetic joint infection (PJI) is the most common cause of total knee replacement failure and the third most common cause of total hip replacement failure, accounting for 16.8% of all knee revisions and 14.8% of the hip revisions; nevertheless, the diagnosis of PJI is often a challenge for the orthopaedic surgeon. The aim of these study was to evaluate the reliability of the LE strip test for diagnosis of PJI. From December 2016 to January 2019, we enrolled 50 patients with suspected PJI; 32 females and 18 males, the average age at the time of the surgery was 76 years. Twenty-four patients underwent knee revision surgery and twenty-six hip revision surgery. In all patients during the surgery, the synovial fluid was aspirated and used for leukocyte esterase strip test. The result of the tests was compared to periprosthetic tissues culture, histological examination and sonication fluid culture for PJI. Comparing the results obtained from the LE test with the results obtained from the other diagnostic methods, we found that the concordance between the results of the leukocyte-esterase test and those of the culture test with peri-prosthetic tissue or synovial fluid was shown to be 93%, between LE and histological examinations, the concordance was 93% and finally with the culture of the sonicated fluid the concordance was 86% of the cases. The results of our serie show a good intraoperative diagnostic accuracy of the LE test, especially in its ability to exclude the hypothesis of periprosthetic infection in case of a negative result.
- Open Access
- 5 December 2019
- Vol. 90 (12-S) , 54-63
Onlay versus Inlay humeral steam in Reverse Shoulder Arthroplasty (RSA): clinical and biomechanical study.
Reverse shoulder arthroplasty (RSA) is becoming treatment of choice in glenohumeral arthropathies with massive lesion of the rotator cuff, due to a gradual extension of indications and new designs that provide better outcome. In this study we compared two different reverse shoulder prosthesis designs, defined as Inlay (or typical Grammont type) and a relatively new model defined as Onlay (that preserves tuberosity bone stock). We analyzed clinical, biomechanical and radiological outcomes, as well as complications of RSA in these two groups. We performed a prospective study on a population of 42 patients undergoing Reverse Shoulder Replacement by a single expert surgeon. We consider 21 patients (group A) who underwent to reverse shoulder replacement with a curved onlay steam with 145° inclination (Ascend Flex group, Wright medical, Memphis, TN, USA) and 21 patients who underwent to reverse shoulder replacement with a traditional Inlay Grammont steam (Modular Shoulder System SMR, Systema Multiplana Randelli; Lima-LTO, San Daniele del Friuli, Italy) between August 2010 and October 2018. We studied the following items: active range of motion (AROM), radiological parameters (lateralization shoulder angle LSA, Distalization Shoulder Angle DSA), functional scale (Constant-Murley Score), post-operative complications (infection, aseptical implant mobilitazion, residual pain, scapular notching, fractures, tuberosity reabsorbtion, dislocation, bleedings, nerve palsy, pulmonary embolus). A significant improvement in ROM and functional score (Constant Shoulder Score) were observed in both groups. Group A (Onlay design 145°, medial tray) provides improvement in adduction, extension and external rotation compared to group B. No significant differences were found in abduction, external rotation and forward flexion. At 6 months follow-up, pain relief was detected in all patients. Although complications occur in a high percentage of patients in literature, no postoperative complications were observed in our cases series. Our results showed how RSA is a real solution to improve quality of life and to restore pain-free shoulder ROM in patients where cuff tear arthropathy occurs. Onlay design 145° may provides better active external rotation, extension, adduction: it is necessary to continue follow up and include more cases to prove these data.
- 5 December 2019
- Vol. 90 (12-S) , 54-63
Open AccessOnlay versus Inlay humeral steam in Reverse Shoulder Arthroplasty (RSA): clinical and biomechanical study.
Reverse shoulder arthroplasty (RSA) is becoming treatment of choice in glenohumeral arthropathies with massive lesion of the rotator cuff, due to a gradual extension of indications and new designs that provide better outcome. In this study we compared two different reverse shoulder prosthesis designs, defined as Inlay (or typical Grammont type) and a relatively new model defined as Onlay (that preserves tuberosity bone stock). We analyzed clinical, biomechanical and radiological outcomes, as well as complications of RSA in these two groups. We performed a prospective study on a population of 42 patients undergoing Reverse Shoulder Replacement by a single expert surgeon. We consider 21 patients (group A) who underwent to reverse shoulder replacement with a curved onlay steam with 145° inclination (Ascend Flex group, Wright medical, Memphis, TN, USA) and 21 patients who underwent to reverse shoulder replacement with a traditional Inlay Grammont steam (Modular Shoulder System SMR, Systema Multiplana Randelli; Lima-LTO, San Daniele del Friuli, Italy) between August 2010 and October 2018. We studied the following items: active range of motion (AROM), radiological parameters (lateralization shoulder angle LSA, Distalization Shoulder Angle DSA), functional scale (Constant-Murley Score), post-operative complications (infection, aseptical implant mobilitazion, residual pain, scapular notching, fractures, tuberosity reabsorbtion, dislocation, bleedings, nerve palsy, pulmonary embolus). A significant improvement in ROM and functional score (Constant Shoulder Score) were observed in both groups. Group A (Onlay design 145°, medial tray) provides improvement in adduction, extension and external rotation compared to group B. No significant differences were found in abduction, external rotation and forward flexion. At 6 months follow-up, pain relief was detected in all patients. Although complications occur in a high percentage of patients in literature, no postoperative complications were observed in our cases series. Our results showed how RSA is a real solution to improve quality of life and to restore pain-free shoulder ROM in patients where cuff tear arthropathy occurs. Onlay design 145° may provides better active external rotation, extension, adduction: it is necessary to continue follow up and include more cases to prove these data.
- Open Access
- 5 December 2019
- Vol. 90 (12-S) , 91-97
Pre-operative and post-operative kinematic analysis in total knee arthroplasty. A pilot study.
Total knee replacement is the treatment of choice in knee osteoarthritis. Despite this, there is still a percentage of unsatisfied patients. Recently, prosthetic designs have been developed to improve the kinematics of the prosthetic knee. Between June 2016 and November 2016 we enrolled 26 patients underwent to total knee arthroplasty divided in two groups (A and B) treated respectively with Journey 2 implant and the Attune impltant. Each patient was evaluated with functional scores (KOOS and KSS) and with kinematic analysis using the Bioval System. In the group A, compared to the pre-operative, the flexion of the operated knees is significantly increased (31.27°±3.13° → 35.02°±2.1°) as well as that of the unoperated knee (34.34°±2.8° → 35.39°±3.5°). The pre/post-operative comparison of the muscles' activation timing showed an improvement for the unoperated side, which is closed to the physiological pattern, while the operated side showed an incorrect activation of all the investigated muscles. The Journey 2 prosthesis seems to reach better results in rotational flexion, rotational freedom and muscles activation during free walking. Furthermore, it seems that with this prosthesis the patient can feel his "new prosthetic knee" more similar and closer to the physiological one. More studies are needed to confirm these results.
- 5 December 2019
- Vol. 90 (12-S) , 91-97
Open AccessPre-operative and post-operative kinematic analysis in total knee arthroplasty. A pilot study.
Total knee replacement is the treatment of choice in knee osteoarthritis. Despite this, there is still a percentage of unsatisfied patients. Recently, prosthetic designs have been developed to improve the kinematics of the prosthetic knee. Between June 2016 and November 2016 we enrolled 26 patients underwent to total knee arthroplasty divided in two groups (A and B) treated respectively with Journey 2 implant and the Attune impltant. Each patient was evaluated with functional scores (KOOS and KSS) and with kinematic analysis using the Bioval System. In the group A, compared to the pre-operative, the flexion of the operated knees is significantly increased (31.27°±3.13° → 35.02°±2.1°) as well as that of the unoperated knee (34.34°±2.8° → 35.39°±3.5°). The pre/post-operative comparison of the muscles' activation timing showed an improvement for the unoperated side, which is closed to the physiological pattern, while the operated side showed an incorrect activation of all the investigated muscles. The Journey 2 prosthesis seems to reach better results in rotational flexion, rotational freedom and muscles activation during free walking. Furthermore, it seems that with this prosthesis the patient can feel his "new prosthetic knee" more similar and closer to the physiological one. More studies are needed to confirm these results.
- Open Access
- 5 December 2019
- Vol. 90 (12-S) , 104-108
Comparison between standard technique and image-free robotic technique in medial unicompartmental knee arthroplasty. Preliminary data.
The factors that guarantee the survival of the unicompartmental prosthesis implant seems to be linked to the accurate positioning of the components. The aim of our study is to compare the standard operative technique and the assisted navigation technique to understand if the robotic technology is able to obtain more accurate implants and with a better outcome. In the period between January 2016 and February 2018, in our Clinic, were performed 94 medial unicompartmental knee implants. The implantation of the medial unicompartmental prosthesis was performed in 30 cases with the standard technique and in 29 cases with the image-free robotic technique (Navio Surgical System). The objective of our study was to evaluate the anatomical and mechanical axes, the tibial slope, the coronal inclination of the femoral tibial space, the coronal angulation of the tibial and femoral component and the height of the Joint-Line. Furthermore, to evaluate the outcome we has execute international scores (IKDC and KSS Insall mod.). The advanced navigation seems to allow the implantation of the unicompartmental prosthesis more precisely, although not always with a statistically significant difference compared to the standard technique. further clinical studies are needed to analyze the medium and long-term survival rate, as well as the patient's subjective outcome.
- 5 December 2019
- Vol. 90 (12-S) , 104-108
Open AccessComparison between standard technique and image-free robotic technique in medial unicompartmental knee arthroplasty. Preliminary data.
The factors that guarantee the survival of the unicompartmental prosthesis implant seems to be linked to the accurate positioning of the components. The aim of our study is to compare the standard operative technique and the assisted navigation technique to understand if the robotic technology is able to obtain more accurate implants and with a better outcome. In the period between January 2016 and February 2018, in our Clinic, were performed 94 medial unicompartmental knee implants. The implantation of the medial unicompartmental prosthesis was performed in 30 cases with the standard technique and in 29 cases with the image-free robotic technique (Navio Surgical System). The objective of our study was to evaluate the anatomical and mechanical axes, the tibial slope, the coronal inclination of the femoral tibial space, the coronal angulation of the tibial and femoral component and the height of the Joint-Line. Furthermore, to evaluate the outcome we has execute international scores (IKDC and KSS Insall mod.). The advanced navigation seems to allow the implantation of the unicompartmental prosthesis more precisely, although not always with a statistically significant difference compared to the standard technique. further clinical studies are needed to analyze the medium and long-term survival rate, as well as the patient's subjective outcome.
- Open Access
- 5 December 2019
- Vol. 90 (12-S) , 174-177
Groin pain caused by iliopsoas synovial cyst treated with endoscopic approach. A case report.
The diagnosis of iliopsoas synovial cyst is a rare finding. The normal approach to treat this condition has been conservative therapies or open surgery, with its associated complications and morbidity. The arthroscopic - endoscopic surgery is less invasive and with an increase in complications and days of hospitalization. We report the case of a 70-year old woman with clinical and imaging signs of a fluid-filled cyst near iliopsoas distal tendon. After fluid aspiration, the patient reported symptom-free interval of several weeks, but then groin pain and swelling feeling return, increased with hip movements. The cyst was removed through arthroscopy approach and the iliopsoas tendon was released. The removal of iliopsoas synovial cyst is necessary to avoid complications such as pain and functional limits. Arthroscopy has the advantage of less soft-tissue damage and quicker recovery. The treatment of associated tendon pathology can be done. Hip arthroscopy can be a safe and effective technique for the removal of iliopsoas synovial cyst.
- 5 December 2019
- Vol. 90 (12-S) , 174-177
Open AccessGroin pain caused by iliopsoas synovial cyst treated with endoscopic approach. A case report.
The diagnosis of iliopsoas synovial cyst is a rare finding. The normal approach to treat this condition has been conservative therapies or open surgery, with its associated complications and morbidity. The arthroscopic - endoscopic surgery is less invasive and with an increase in complications and days of hospitalization. We report the case of a 70-year old woman with clinical and imaging signs of a fluid-filled cyst near iliopsoas distal tendon. After fluid aspiration, the patient reported symptom-free interval of several weeks, but then groin pain and swelling feeling return, increased with hip movements. The cyst was removed through arthroscopy approach and the iliopsoas tendon was released. The removal of iliopsoas synovial cyst is necessary to avoid complications such as pain and functional limits. Arthroscopy has the advantage of less soft-tissue damage and quicker recovery. The treatment of associated tendon pathology can be done. Hip arthroscopy can be a safe and effective technique for the removal of iliopsoas synovial cyst.
- Open Access
- 10 January 2019
- Vol. 90 (1-S) , 192-197
Can UKA after KineSpring system failure be a viable option? A case report
The KineSpring System is an alternative treatment offered in selected symptomatic patients suffering from mild to moderate medial knee osteoarthritis (OA). This device reduces medial compartment loads in the OA knee without compromising the integrity of the lateral or patellofemoral knee compartments, maintaining the normal knee anatomy. Currently, papers about KineSpring System installation show promising results. The current authors describe a case of unicompartmental knee arthroplasty (UKA) employed to treat medial knee OA after Kinespring system failure. A 64-year old male patient presented to our hospital after failure of a Kinespring system implantation into his left knee at an external hospital, where the outcomes obtained were not satisfactory. The surgical options discussed with the patient were the TKA or medial UKA. A medial UKA was preferred by the patient. One year from UKA, the patient complained of frequent joint effusions and weight bearing pain despite a good ROM without radiographic signs of implant loosening. Therefore, after two years we replaced UKA with total knee arthroplasty (TKA). Further experience is needed to provide reliable clinical data about the results of the UKA after KineSpring System discharge.
- 10 January 2019
- Vol. 90 (1-S) , 192-197
Open AccessCan UKA after KineSpring system failure be a viable option? A case report
The KineSpring System is an alternative treatment offered in selected symptomatic patients suffering from mild to moderate medial knee osteoarthritis (OA). This device reduces medial compartment loads in the OA knee without compromising the integrity of the lateral or patellofemoral knee compartments, maintaining the normal knee anatomy. Currently, papers about KineSpring System installation show promising results. The current authors describe a case of unicompartmental knee arthroplasty (UKA) employed to treat medial knee OA after Kinespring system failure. A 64-year old male patient presented to our hospital after failure of a Kinespring system implantation into his left knee at an external hospital, where the outcomes obtained were not satisfactory. The surgical options discussed with the patient were the TKA or medial UKA. A medial UKA was preferred by the patient. One year from UKA, the patient complained of frequent joint effusions and weight bearing pain despite a good ROM without radiographic signs of implant loosening. Therefore, after two years we replaced UKA with total knee arthroplasty (TKA). Further experience is needed to provide reliable clinical data about the results of the UKA after KineSpring System discharge.
- Open Access
- 10 January 2019
- Vol. 90 (1-S) , 104-109
Arthroscopic treatment of iliopsoas impingement syndrome after hip arthroplasty
Groin pain after hip arthroplasty (HA) ranges from 0.4% to 18.3%. Defining the cause of groin pain after HA can be difficult. Iliopsoas impingement (IPI) has been reported to be the underlying cause of groin pain in up to 4.4% of cases. The purpose of this study is to present arthroscopic surgical outcomes in the treatment of IPI after HA. Between September 2013 and March 2018, 13 patients, 11 total hip arthroplasty (THA), 1 hip endoprosthesis and 1 total hip resurfacing affected by groin pain due to unceasing iliopsoas tendinopathy for impingement after HA were treated arthroscopically. The patients underwent to physical examination, blood analysis, hip X-rays, bone scintigraphy and CT assessment. We performed the arthroscopic OUT-IN access to hip joint in all patients. VAS scale, Harris Hip Score (HHS) and Medical Research Council (MRC) scale were performed before surgery and during follow up at 1-3-6-12 months. After 10 months of mean follow-up, average HHS and MRC scale improved significantly from preoperatively to postoperatively. No complications arose in our case series. Hip arthroscopy after hip arthroplasty is supported in the literature for a variety of indications. Hip arthroscopy is a viable and reproducible technique in treatment of IPI, being less invasive than the classic open technique. This simple arthroscopic release provides satisfactory results and preserves HA function. Moreover an arthroscopic OUT-IN access proves good clinical outcomes, few complications and iatrogenic lesions.
- 10 January 2019
- Vol. 90 (1-S) , 104-109
Open AccessArthroscopic treatment of iliopsoas impingement syndrome after hip arthroplasty
Groin pain after hip arthroplasty (HA) ranges from 0.4% to 18.3%. Defining the cause of groin pain after HA can be difficult. Iliopsoas impingement (IPI) has been reported to be the underlying cause of groin pain in up to 4.4% of cases. The purpose of this study is to present arthroscopic surgical outcomes in the treatment of IPI after HA. Between September 2013 and March 2018, 13 patients, 11 total hip arthroplasty (THA), 1 hip endoprosthesis and 1 total hip resurfacing affected by groin pain due to unceasing iliopsoas tendinopathy for impingement after HA were treated arthroscopically. The patients underwent to physical examination, blood analysis, hip X-rays, bone scintigraphy and CT assessment. We performed the arthroscopic OUT-IN access to hip joint in all patients. VAS scale, Harris Hip Score (HHS) and Medical Research Council (MRC) scale were performed before surgery and during follow up at 1-3-6-12 months. After 10 months of mean follow-up, average HHS and MRC scale improved significantly from preoperatively to postoperatively. No complications arose in our case series. Hip arthroscopy after hip arthroplasty is supported in the literature for a variety of indications. Hip arthroscopy is a viable and reproducible technique in treatment of IPI, being less invasive than the classic open technique. This simple arthroscopic release provides satisfactory results and preserves HA function. Moreover an arthroscopic OUT-IN access proves good clinical outcomes, few complications and iatrogenic lesions.
- Open Access
- 10 January 2019
- Vol. 90 (1-S) , 92-97
Heterotopic Ossification in Primary Total Hip Arthroplasty: which is the role of drainage?
The Heterotopic Ossification (HO) is a common complication following Total Hip Arthroplasty (THA). Although there is no concordance in Literature regarding the etiopathogenic mechanism, various HO risk factors have been recognized, both related to the patient and associated with the surgical procedureLiterature does not consider the use of intra-articular drainage as a possible risk factor. Our hypothesis is that this item can contribute to the development of HO. 425 implants of hip arthroplasty performed between 2014 and 2017 at the Ortopedic Clinic of Udine were included in the study. No patient performed pre-operative or post-operative anti-HO prophylaxis during follow-up. Radiographs of preoperative and postoperative at 1 year were analyzed according to the Brooker Classification. The incidence of HO in patients with intra-articular drainage is 24.6%, while the incidence of HO in patients without intra-articular drainage is 15.3%, with a statistically significant difference. The data obtained suggest to consider the use of intra-articular drainage as a possible intra-operative risk factor for HO. This is a retrospective cohort study, so we need more studies and more robust experimental designs to confirm these results.
- 10 January 2019
- Vol. 90 (1-S) , 92-97
Open AccessHeterotopic Ossification in Primary Total Hip Arthroplasty: which is the role of drainage?
The Heterotopic Ossification (HO) is a common complication following Total Hip Arthroplasty (THA). Although there is no concordance in Literature regarding the etiopathogenic mechanism, various HO risk factors have been recognized, both related to the patient and associated with the surgical procedureLiterature does not consider the use of intra-articular drainage as a possible risk factor. Our hypothesis is that this item can contribute to the development of HO. 425 implants of hip arthroplasty performed between 2014 and 2017 at the Ortopedic Clinic of Udine were included in the study. No patient performed pre-operative or post-operative anti-HO prophylaxis during follow-up. Radiographs of preoperative and postoperative at 1 year were analyzed according to the Brooker Classification. The incidence of HO in patients with intra-articular drainage is 24.6%, while the incidence of HO in patients without intra-articular drainage is 15.3%, with a statistically significant difference. The data obtained suggest to consider the use of intra-articular drainage as a possible intra-operative risk factor for HO. This is a retrospective cohort study, so we need more studies and more robust experimental designs to confirm these results.
- Open Access
- 10 January 2019
- Vol. 90 (1-S) , 36-46
Rotator cuff tears reparability index based on pre-operative MRI: our experience
It is recognised that a significant percetage of large and massive rotator cuff tears (RCT) cannot be anatomically repaired and this correlates with a worste outcome in terms of pain, active range of motion, increased incidence of retair. The aim of our work is to find reliable index on preoperative MRI shoulder image to assist orthopaedist in surgical planning of rotatator cuff tears repair. We performed a retrospective study on a population on 131 patients undergoing arthroscopic cuff repair by a single expert surgeon. Pre-operative MRI images were evaluated by a single orthopaedist, trained on MRI shoulder images ad blinded to surgical outcome. For each magnetic resonance we evaluated the following 9 parameters: fatty Infiltration (FI), Patte Stage (PS), tear size measured in medial-lateral (ML) and anterior- posterior (AP) dimension, Tangent Sign (TS), Occupation Grade (OG), Acromion-Humeral Distance (AHD), Inferior Gleno-Humeral Distance (IGHD), Glenoid Version Angle (GVA). We divided population into two groups: patients who obtained a complete repair of RCT (n=110) and patients who obtained only a partial repair of RCT (n=21). For each MRI index we conducted statistical analysis (Student's t test, Mann- Whitney U test, Shapiro-Wilk test, Chi-square test, Fisher exact test, ROC curves and maximum Youden index) to find a Cut Off value useful to predict partial repair. We have found statistical significance in predicting partial repair on MRI mesurements of Fatty Infiltration (FI grade ≥3; test di Fisher p36 mm; Mann-Whitney p5 mm). Tear size measured in AP (>21 mm; Mann-Whitney p<0.001) seems to be dependent on the contextual size of the lesion in ML. We haven't found statistical significance in predicting partial repair of Glenoid Version Angle. A systematic observation of seven independent MRI parameters (FI, PS, tear size ML, TS, OG, AHD, IGHD) can help the surgeon to predict the impossibility to obtain complete repair of RCT and to consider different surgical approach.
- 10 January 2019
- Vol. 90 (1-S) , 36-46
Open AccessRotator cuff tears reparability index based on pre-operative MRI: our experience
It is recognised that a significant percetage of large and massive rotator cuff tears (RCT) cannot be anatomically repaired and this correlates with a worste outcome in terms of pain, active range of motion, increased incidence of retair. The aim of our work is to find reliable index on preoperative MRI shoulder image to assist orthopaedist in surgical planning of rotatator cuff tears repair. We performed a retrospective study on a population on 131 patients undergoing arthroscopic cuff repair by a single expert surgeon. Pre-operative MRI images were evaluated by a single orthopaedist, trained on MRI shoulder images ad blinded to surgical outcome. For each magnetic resonance we evaluated the following 9 parameters: fatty Infiltration (FI), Patte Stage (PS), tear size measured in medial-lateral (ML) and anterior- posterior (AP) dimension, Tangent Sign (TS), Occupation Grade (OG), Acromion-Humeral Distance (AHD), Inferior Gleno-Humeral Distance (IGHD), Glenoid Version Angle (GVA). We divided population into two groups: patients who obtained a complete repair of RCT (n=110) and patients who obtained only a partial repair of RCT (n=21). For each MRI index we conducted statistical analysis (Student's t test, Mann- Whitney U test, Shapiro-Wilk test, Chi-square test, Fisher exact test, ROC curves and maximum Youden index) to find a Cut Off value useful to predict partial repair. We have found statistical significance in predicting partial repair on MRI mesurements of Fatty Infiltration (FI grade ≥3; test di Fisher p36 mm; Mann-Whitney p5 mm). Tear size measured in AP (>21 mm; Mann-Whitney p<0.001) seems to be dependent on the contextual size of the lesion in ML. We haven't found statistical significance in predicting partial repair of Glenoid Version Angle. A systematic observation of seven independent MRI parameters (FI, PS, tear size ML, TS, OG, AHD, IGHD) can help the surgeon to predict the impossibility to obtain complete repair of RCT and to consider different surgical approach.