Vladimir Dub
Research Subjects
Vladimir Dub has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- A. A. Dolgalev
Stavropol State Med Univ, Dept Gen & Pediat Dent, 310 Mira St, Stavropol 355017, Russia
1 shared publication Alexandr Churyomov
The National University of Science and Technology MISiS, Russian Federation
1 shared publicationAnton Popkov
United Heavy Machinery Plants, Russian Federation
1 shared publication- Dmitry Svyatoslavov
Institute for Regenerative Medicine, Sechenov University, Ministry of Health of Russia, Bolshaya Pirogovskaya, 6/1, Moscow 119431, Russia
1 shared publication I. A. Shchenkova
OAO NPO TsNIITMASh
1 shared publicationIgor Soloviev
Ural Federal University named after the first President of Russia B.N.Yeltsin», Russian Federation
1 shared publication
Latest Publications
- Open Access
- 3 February 2020
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 10 (1) , 6
Experimental Biointegration of a Titanium Implant in Delayed Mandibular Reconstruction
Background: Mandibular reconstruction, after extensive resection of the mandible for the treatment of oral cancer, is a well-known procedure, however, relatively little is known about bone integration into the titanium implant after reconstruction with a temporary plastic implant. The main goal of this experimental study was to study the process of osseous integration into the titanium implant in an in vivo experiment following prior mandibular reconstruction with a temporary plastic implant. Materials and Methods: Four ewes initially underwent a partial one-sided resection of the mandible, with the formation of an approximately 3 × 1 cm defect. All of the subjects received reconstruction with an implantation of a plastic plate (3 cm). The plastic plate was removed and replaced by a titanium implant at 1, 3, 6, and 12 months, accordingly. Both plastic and titanium implants were made via 3D-printing technology and personalized modeling. A total of 6 months after titanium implantation, a histological evaluation of biointegration was performed. Results: All surgeries were uncomplicated. The integration of osseous tissue into the titanium implant was seen in all cases. Histologically, each case showed variable integration of dense fibrotic tissue with fibroblasts and non-mature bone tissue with a definitive layer of bone matrix with many osteoblasts on the periphery. The prior implantation of the plastic plate did not interfere with bone integration into the titanium implant. Conclusion: Preliminary results demonstrated that a temporary plastic implant for mandibular reconstruction does not interfere with the consequent osseous biointegration of a permanent titanium implant. This shows that temporary reconstruction is a safe solution when delayed mandibular reconstruction is required due to disease severity.
- 3 February 2020
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 10 (1) , 6
Open AccessExperimental Biointegration of a Titanium Implant in Delayed Mandibular Reconstruction
Background: Mandibular reconstruction, after extensive resection of the mandible for the treatment of oral cancer, is a well-known procedure, however, relatively little is known about bone integration into the titanium implant after reconstruction with a temporary plastic implant. The main goal of this experimental study was to study the process of osseous integration into the titanium implant in an in vivo experiment following prior mandibular reconstruction with a temporary plastic implant. Materials and Methods: Four ewes initially underwent a partial one-sided resection of the mandible, with the formation of an approximately 3 × 1 cm defect. All of the subjects received reconstruction with an implantation of a plastic plate (3 cm). The plastic plate was removed and replaced by a titanium implant at 1, 3, 6, and 12 months, accordingly. Both plastic and titanium implants were made via 3D-printing technology and personalized modeling. A total of 6 months after titanium implantation, a histological evaluation of biointegration was performed. Results: All surgeries were uncomplicated. The integration of osseous tissue into the titanium implant was seen in all cases. Histologically, each case showed variable integration of dense fibrotic tissue with fibroblasts and non-mature bone tissue with a definitive layer of bone matrix with many osteoblasts on the periphery. The prior implantation of the plastic plate did not interfere with bone integration into the titanium implant. Conclusion: Preliminary results demonstrated that a temporary plastic implant for mandibular reconstruction does not interfere with the consequent osseous biointegration of a permanent titanium implant. This shows that temporary reconstruction is a safe solution when delayed mandibular reconstruction is required due to disease severity.
- Open Access
- 31 October 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 132, 03007
Developing of complex for hot plastic deformation modeling of steel type 20-30CrNiMoV for heavy forging
Production of heavy forging of bars weighing more then 235 tons for such products as rotors made of steel type 20-30CrNiMoV is a critical independent work, failure to perform which entails high costs related to repeated production (in case of defective product) and untimely launch of production plants. One of the frequent causes of a defective product is the impossibility of ultrasonic testing in the barrel-gate zones on the rotor workpiece, which is due to the microstructure of the metal, namely the grain size. Determing the stages of deformation process wich causes such defects in structure is the main goal of this work.
- 31 October 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 132, 03007
Open AccessDeveloping of complex for hot plastic deformation modeling of steel type 20-30CrNiMoV for heavy forging
Production of heavy forging of bars weighing more then 235 tons for such products as rotors made of steel type 20-30CrNiMoV is a critical independent work, failure to perform which entails high costs related to repeated production (in case of defective product) and untimely launch of production plants. One of the frequent causes of a defective product is the impossibility of ultrasonic testing in the barrel-gate zones on the rotor workpiece, which is due to the microstructure of the metal, namely the grain size. Determing the stages of deformation process wich causes such defects in structure is the main goal of this work.
- 1 June 2012
- Published by Pleiades Publishing Ltd in Russian Metallurgy (Metally)
- Vol. 2012 (6) , 527-530
Influence of heat treatment on the structure and hardness of 9% chromium steel
The results of studying the influence of the heat treatment conditions on the structure and properties of new nanostructured steel with 8–10% Cr designed for heat power units with supercritical parameters are presented.
- 1 June 2012
- Published by Pleiades Publishing Ltd in Russian Metallurgy (Metally)
- Vol. 2012 (6) , 527-530
Influence of heat treatment on the structure and hardness of 9% chromium steel
The results of studying the influence of the heat treatment conditions on the structure and properties of new nanostructured steel with 8–10% Cr designed for heat power units with supercritical parameters are presented.