ATAndrew Thorpe

Andrew Thorpe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew Thorpe has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantifying Dustiness, Specific Allergens, and Endotoxin in Bulk Soya Imports

    by Howard J. Mason, Susana Gómez-Ollés, Maria-Jesus Cruz, Paul Roberts, Andrew Thorpe, Gareth Evans

    Soya is an important bulk agricultural product often transported by sea as chipped beans and/or the bean husks after pelletisation. There are proven allergens in both forms. Bulk handling of soya imports can generate air pollution containing dust, allergens, and pyrogens, posing health risks to dockside workers and surrounding populations. Using an International Organization for Standardization (ISO) standardised rotating drum dustiness test in seven imported soya bulks, we compared the generated levels of dust and two major soya allergens in three particle sizes related to respiratory health. Extractable levels of allergen and endotoxin from the bulks showed 30–60 fold differences, with levels of one allergen (hydrophobic seed protein) and endotoxin higher in husk. The generated levels of dust and allergens in the three particle sizes also showed very wide variations between bulks, with aerolysed levels of allergen influenced by both the inherent dustiness and the extractable allergen in each bulk. Percentage allergen aerolysed from pelletized husk—often assumed to be of low dustiness—after transportation was not lower than that from chipped beans. Thus, not all soya bulks pose the same inhalation health risk and reinforces the importance of controlling dust generation from handling all soya bulk to as low as reasonably practicable.


  • Open Access

    Reducing dust and allergen exposure in bakeries

    by Howard J Mason, Susan Fraser, Andrew Thorpe, Paul Roberts, Gareth Evans

    Bakers have a continuing high incidence of occupational allergic asthma. In factory bakeries they are exposed not only to flour dust containing allergens, but also improvers whose ingredients enhance the strength and workability of the dough and its speed of rising. Improvers are flour-based but can contain added soya, fungal or bacterial enzymes that are also allergenic, as well as vegetable oil, calcium sulphate/silicate and organic esters. This study investigated the dustiness of the components used in factory bakeries and whether altering improver ingredients could reduce dust and allergen exposure. A standardised rotating drum test was employed on the individual components, as well as a representative improver and three practicable improver modifications by decreasing calcium sulphate, calcium silicate or increasing oil content. Levels of dust, the allergens wheat flour amylase inhibitor (WAAI) and soya trypsin inhibitor (STI) were measured in the generated inhalable, thoracic and respirable sized fractions. A “scooping and pouring” workplace simulation was also performed. Initial tests showed that dustiness of several wheat flours was relatively low, and even lower for soya flour, but increased in combination with some other improver components. All three improver modifications generally reduced levels of dust, STI and WAAI, but increasing oil content significantly decreased dust and STI in comparison to the standard improver and those improvers with reduced calcium silicate or sulphate. The simulation demonstrated that increased oil content reduced inhalable levels of gravimetric dust, STI and WAAI. Changing improver formulation, such as increasing oil content of flour by a small amount, may represent a simple, practical method of reducing bakery workers’ exposure to dust and allergens where improvers are used. It may be a useful adjunct to engineering control, changes to work practices and appropriate training in reducing the risk to bakers’ respiratory health.


  • Open Access

    Direct-Reading Inhalable Dust Monitoring—An Assessment of Current Measurement Methods

    by Andrew Thorpe, Peter T. Walsh

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the photometer-type dust monitors on the other hand showed little correlation. The Respicon also accurately measured the inhalable concentration, whereas the modified PDM underestimated it by ~27%. Photometer responses varied considerably with changing particle size, which resulted in appreciable errors in airborne inhalable dust concentration measurements. Similar trends were also observed during field trials. Despite having limitations, both the modified PDM and Respicon showed promise as real-time inhalable dust monitors.


  • Open Access

    Comparison of Portable, Real-Time Dust Monitors Sampling Actively, with Size-Selective Adaptors, and Passively

    by Andrew Thorpe, Peter T. Walsh

    The performance of three, portable, real-time dust monitors was investigated inside a calm air dust chamber for a range of industrial dusts and two sizes of aluminium oxide dust. The instruments tested were the Split 2 (SKC Ltd), Microdust Pro (Casella Ltd) and DataRam (Thermo Electron Ltd), which sampled either passively or actively by connecting a manufacturer-supplied, size-selective adaptor and an air sampling pump to the inlet of the monitor. Two size-selective adaptors were tested with the Split 2: the GS-3 cyclone adaptor and the Institute of Occupational Medicine (IOM) inlet with porous foam inserts. Similarly, two size-selective adaptors were tested with the Microdust Pro: the Higgins–Dewell cyclone adaptor and the conical inhalable sampler (CIS) adaptor with porous foam inserts. The DataRam was tested with a GK 2.05 cyclone adaptor since there was no porous foam adaptor available. The instruments' responses were compared with the reference dust samplers: Casella Higgins–Dewell cyclone for the respirable fraction and IOM sampler for the inhalable fraction. The response of the dust monitors was found to be linear with respirable dust concentration when operated either passively or actively using the cyclone size-selective inlets. Their responses were, however, lower when operated actively with the cyclone adaptors compared to the passive operation and lower still when used with the porous foam inserts. There was also often more scatter in the porous foam measurements, attributable to variable clogging of the foams caused by inconsistent loading with dust. The dust monitor responses were sensitive to changes in particle size when operated passively but much less so in active mode with the cyclone adaptors. The Microdust Higgins–Dewell cyclone adaptor measurements agreed closely with the reference respirable concentration for all dusts, whereas those for the DataRam GK 2.05 and Split 2 GS-3 cyclone adaptors were different to the reference. Concentrations measured with the foam adaptors were considerably lower than both the reference cyclone samplers and the dust monitor cyclone adaptors and increasingly undersampled as they became loaded with dust. Inhalable dust measured with the Split 2 IOM adaptor agreed closely with the reference IOM inhalable samplers, whereas the Microdust CIS adaptor underestimated the inhalable concentration compared to the reference.


  • Open Access

    Assessment of Personal Direct-Reading Dust Monitors for the Measurement of Airborne Inhalable Dust

    by Andrew Thorpe

    The performances of five portable direct-reading dust monitors were investigated in a wind tunnel for a range of industrial dusts and three sizes of aluminium oxide test dust to mainly determine their suitability for measuring the inhalable fraction of airborne dust in workplaces. The instruments tested were Split 2 (SKC Ltd), Sidepak (TSI Inc.), Dataram (Thermo Electron Ltd), PDS-2 (Sibata Scientific Technology Ltd) and the Respicon TM (Hund Ltd). The instruments' responses were compared with reference dust samplers. These were the IOM sampler for the inhalable fraction and the Casella cyclone sampler for the respirable fraction. All instruments are predominantly responsive to and are designed to measure particles in the respirable size range, although two of the instruments, the Split 2 and Respicon TM, are claimed to be capable of measuring inhalable-sized particles. For the purpose of the tests, major modifications to an existing wind tunnel dust injection system were made to facilitate the generation of uniform concentrations of large inhalable-sized dust particles at low air velocities. Each monitor greatly underestimated the measurement of inhalable concentration for all the dusts tested, although the linearity was good over a wide range of concentrations for any particular size distribution of dust. However, their calibration factors, defined as the ratio of reference inhalable concentration to monitor concentration, were especially sensitive to changes in particle size as the response of the instruments decreased rapidly with increasing particle size. The monitors generally overestimated the measurement of respirable dust concentration by up to a factor of about 2, apart from the PDS-2, which underestimated it by a factor of up to 3. There was, however, a great deal more scatter in the reference respirable concentration measurements owing to the collection of small dust samples. Therefore, monitor linearity and effects of monitor response to changes in particle size could not be accurately investigated for the respirable fraction. The sampling head of the Split 2 monitor incorporates an IOM inlet and filter to gravimetrically collect the inhalable fraction of airborne dust. This can give a concurrent reference measure of inhalable airborne dust concentration. However, poor sealing within the sampling head resulted in some of the sampled dust not reaching the backup filter. This resulted in the Split 2 underestimating the reference inhalable dust concentration, which meant that it could not be accurately used as a calibration standard. Communications with the manufacturers have since revealed that the sampling head has recently been redesigned in order to improve the seal and eliminate leakage. The Respicon sampler gravimetrically underestimated the inhalable dust concentration, and did so increasingly as the particle size increased.