HVHannah Varner

Hannah Varner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hannah Varner has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evolving properties of biological materials captured via needle-based cavity expansion method

    by Hannah M. Varner, S. Kiana Naghibzadeh, Katie C. Spaeth, Abigail Klein, Tal Cohen

    Background: The mechanical properties of biological tissues change over time and with disease progression. Quantifying these mechanical properties can thus be instrumental for medical diagnosis and for evaluation of tissue viability for transplant. However, soft and biological materials are exceptionally challenging to mechanically characterize using conventional testing methods, which are hindered by limitations of sample size, fixturing capabilities, and sample preparation. Objective: We hypothesize that Volume Controlled Cavity Expansion (VCCE) is well-suited to capture subtle mechanical differences in biological tissue. The objective of this work is therefore twofold: first, we seek to quantify how stiffness of liver and gelatin evolve with age. In achieving this understanding, we aim to demonstrate the precision of VCCE in measuring subtle changes in the mechanical properties of biological tissues. Methods: Performing VCCE tests over 15 days in samples of gelatin and liver (porcine and bovine), we track the evolving pressure-volume response and deformation limits of the materials. Results: In both materials, we observed time-dependent variation of the stiffness and fracture thresholds. In gelatin VCCE repeatably captured stiffening over time, which was correlated with a higher fracture stress. This was in contrast to observations in bovine liver, where stiffening corresponded to a lower fracture stress. Porcine liver initially stiffened, then reversed this trend and relaxed. Conclusion: Through this work we show that liver and gelatin stiffen with age, and that this trend is measurable via VCCE. These results highlight the utility of VCCE and call attention to the need for a new class of mechanism based constitutive models that are capable of capturing variations in material over time with a minimal number of parameters.

  • Open Access

    Explaining the spread in measurement of PDMS elastic properties: influence of test method and curing protocol

    by Hannah Varner, Tal Cohen

    Accuracy in the measurement of mechanical properties is essential for precision engineering and for the interrogation of composition–property relationships.


  • Open Access

    Elasticity of Whole Blood Clots Measured via Volume Controlled Cavity Expansion

    by Hannah Varner, Gabriella P. Sugerman, Manuel K. Rausch, Tal Cohen

    Measuring and understanding the mechanical properties of blood clots can provide insights into disease progression and the effectiveness of potential treatments. However, several limitations hinder the use of standard mechanical testing methods to measure the response of soft biological tissues, like blood clots. These tissues can be difficult to mount, and are inhomogeneous, irregular in shape, scarce, and valuable. To remedy this, we employ in this work Volume Controlled Cavity Expansion (VCCE), a technique that was recently developed, to measure local mechanical properties of soft materials in their natural environment. Through a highly controlled volume expansion of a water bubble at the tip of an injection needle, paired with simultaneous measurement of the resisting pressure, we obtain a local signature of whole blood clot mechanical response. Comparing this data with predictive theoretical models, we find that a 1-term Ogden model is sufficient to capture the nonlinear elastic response observed in our experiments and produces shear modulus values that are comparable to values reported in the literature. Moreover, we find that bovine whole blood stored at 4°C for greater than 2 days exhibits a statistically significant shift in the shear modulus from 2.53 ± 0.44 kPa on day 2 ( N = 13) to 1.23 ± 0.18 kPa on day 3 ( N = 14). In contrast to previously reported results, our samples did not exhibit viscoelastic rate sensitivity within strain rates ranging from 0.22 – 21.1 s −1 . By surveying existing data on whole blood clots for comparison, we show that this technique provides highly repeatable and reliable results, hence we propose the more widespread adoption of VCCE as a path forward to building a better understanding of the mechanics of soft biological materials. Graphical Highlights: Volume controlled cavity expansion overcomes common obstacles to testing biological samples Whole blood clot elasticity is well captured by the Ogden hyperelastic material model Shear modulus strain-rate sensitivity was not observed in clots for moderate rates

  • Encapsulation of Microelectronic Assemblies for use in Harsh Environments

    by H. Varner, J. Mahaffey, T. Marinis, C. DiBiasio

    Microelectronic systems that are intended for use in high shock and vibration environments are encapsulated to achieve stable and reliable operation. The physical design of the electronic assembly, the material properties of the encapsulant, and the magnitude and frequency of the inertial loading must all be factored into the system design. Overall robustness to shock and vibration are improved by minimizing the physical size and mass of the system, which increases its stiffness and reduces the magnitude of the inertial forces that must be supported. This work describes the development of an encapsulation process and facilities that are optimized for building high-reliability microelectronic systems that range between one and five cubic centimeters in volume. Finite Element Analysis (FEA) is used to ensure that sensitive components are not overstressed by the encapsulant as a result of residual curing stresses and inertial loading effects. Computational Fluid Dynamics (CFD) software is used to mo...