Sajid Rafique
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sajid Rafique has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Magnus Isaksson
Faculty of Health and Occupational Studies, University of Gävle, Gävle, Sweden
2 shared publicationsAshish Singla
Department of Mechanical Engineering, Thapar Institute of Engineering and Technology, Patiala, India
1 shared publication- Ashish Singla
Thapar Institute of Engineering and Technology
1 shared publication - Magnus Isaksson
Faculty of Health and Occupational Studies, University of Gävle, 801 76 Gävle, Sweden
1 shared publication - Magnus Isaksson
Högskolan i Gävle, SE
1 shared publication Niclas Bjorsell
Department of Electrical Engineering, Mathematics, and Science, University of Gävle, Gävle, Sweden
1 shared publication
Latest Publications
- Open Access
Fault Detection, Isolation and Reconfiguration of Four-Bar Mechanism-Based Knee Exoskeleton
Knee exoskeletons are sophisticated wearable devices engineered to aid or augment human movement, especially in rehabilitation and mobility assistance contexts. To address reliability concerns, the proposed knee exoskeleton incorporates a fault-tolerant control system using a fault detection, isolation and reconfiguration (FDI) technique. This system enables the exoskeleton to continue functioning even if one of the actuators experiences a fault, ensuring user safety and continuous operation. For actuator fault detection, analytical redundancy relations (ARRs) are derived from the bond graph model of the knee exoskeleton. ARRs are monitored for actuator fault detection and isolation. In this work, there is no fault initially; after some time, a fault is created in the rotary actuator; finally, the faulty actuator is reconfigured by another rotary actuator. Simulation findings illustrate the suggested FDI system’s effectiveness in improving the robustness of knee exoskeletons during the sit-to-stand motion. The proposed system successfully reconfigures itself in response to faults.
Open AccessFault Detection, Isolation and Reconfiguration of Four-Bar Mechanism-Based Knee Exoskeleton
Knee exoskeletons are sophisticated wearable devices engineered to aid or augment human movement, especially in rehabilitation and mobility assistance contexts. To address reliability concerns, the proposed knee exoskeleton incorporates a fault-tolerant control system using a fault detection, isolation and reconfiguration (FDI) technique. This system enables the exoskeleton to continue functioning even if one of the actuators experiences a fault, ensuring user safety and continuous operation. For actuator fault detection, analytical redundancy relations (ARRs) are derived from the bond graph model of the knee exoskeleton. ARRs are monitored for actuator fault detection and isolation. In this work, there is no fault initially; after some time, a fault is created in the rotary actuator; finally, the faulty actuator is reconfigured by another rotary actuator. Simulation findings illustrate the suggested FDI system’s effectiveness in improving the robustness of knee exoskeletons during the sit-to-stand motion. The proposed system successfully reconfigures itself in response to faults.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 11
Evaluating the advantages of passive exoskeletons and recommendations for design improvements
Construction and manufacturing workers undertake physically laborious activities which put them at risk of developing serious musculoskeletal disorders (MSDs). In the EU, millions of workers are being affected by workplace-related MSDs, inflicting huge financial implications on the European economy. Besides that, increased health problems and financial losses, severe shortages of skilled labor also emerge. The work aims to create awareness and accelerate the adoption of exoskeletons among SMEs and construction workers to reduce MSDs. Large-scale manufacturers and automobile assemblers are more open to adopt exoskeletons, however, the use of exoskeletons in small and medium enterprises (SMEs) is still not recognized. This paper presents an experimental study demonstrating the advantages of different exoskeletons while performing workers’ tasks. The study illustrates how the use of certain upper and lower body exoskeletons can reduce muscle effort. The muscle activity of the participants was measured using EMG sensors and was compared while performing designated tasks. It was found that up to 60% reduction in human effort can be achieved while performing the same tasks using exoskeletons. This can also help ill workers in rehabilitation and putting them back to work. The study concludes with pragmatic recommendations for future exoskeletons.
- 1 January 2024
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 11
Open AccessEvaluating the advantages of passive exoskeletons and recommendations for design improvements
Construction and manufacturing workers undertake physically laborious activities which put them at risk of developing serious musculoskeletal disorders (MSDs). In the EU, millions of workers are being affected by workplace-related MSDs, inflicting huge financial implications on the European economy. Besides that, increased health problems and financial losses, severe shortages of skilled labor also emerge. The work aims to create awareness and accelerate the adoption of exoskeletons among SMEs and construction workers to reduce MSDs. Large-scale manufacturers and automobile assemblers are more open to adopt exoskeletons, however, the use of exoskeletons in small and medium enterprises (SMEs) is still not recognized. This paper presents an experimental study demonstrating the advantages of different exoskeletons while performing workers’ tasks. The study illustrates how the use of certain upper and lower body exoskeletons can reduce muscle effort. The muscle activity of the participants was measured using EMG sensors and was compared while performing designated tasks. It was found that up to 60% reduction in human effort can be achieved while performing the same tasks using exoskeletons. This can also help ill workers in rehabilitation and putting them back to work. The study concludes with pragmatic recommendations for future exoskeletons.
- Open Access
- 5 July 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-4
Using robotic exoskeletons to reduce muscle activity of workers
- 5 July 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-4
Open AccessUsing robotic exoskeletons to reduce muscle activity of workers
- Open Access
- 1 November 2021
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 18 (6)
Design of a powered full-body exoskeleton for physical assistance of elderly people
The development of full-body exoskeletons has been limited due to design complexities, mechanical integration intricacies, and heavier weight, among others. Consequently, very few full-body powered exoskeletons were developed to address these challenges, in spite of increasing demand for physical assistance at full-body level. This article presents an overall design and development of a powered full-body exoskeleton called “FB-AXO.” Primarily, FB-AXO consists of two main subsystems, a lower-body and an upper-body subsystem connected together through waist and spine modules. FB-AXO is developed for the support of weaker ageing adults so that they can continue functioning their daily activities. At the onset of the project, a set of functional and design requirements has been formulated with an extensive end-user involvement and then used in realizing the FB-AXO. The final FB-AXO design comprises of 27 degrees of freedom, of which 10 are active and 17 are passive, having a total system weight of 25 kg. Overall, the article elaborates comprehensively the design, construction, and preliminary testing of FB-AXO. The work effectively addresses design challenges including kinematic compatibility and modularity with innovative solutions. The details of the mechanics, sensors, and electronics of the two subsystems along with specifics of human-exoskeleton interfaces and ranges of motion are also provided. The FB-AXO exoskeleton effectively demonstrated to assist full-body motions such as normal walking, standing, bending as well as executing lifting and carrying tasks to meet the daily living demands of older users.
- 1 November 2021
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 18 (6)
Open AccessDesign of a powered full-body exoskeleton for physical assistance of elderly people
The development of full-body exoskeletons has been limited due to design complexities, mechanical integration intricacies, and heavier weight, among others. Consequently, very few full-body powered exoskeletons were developed to address these challenges, in spite of increasing demand for physical assistance at full-body level. This article presents an overall design and development of a powered full-body exoskeleton called “FB-AXO.” Primarily, FB-AXO consists of two main subsystems, a lower-body and an upper-body subsystem connected together through waist and spine modules. FB-AXO is developed for the support of weaker ageing adults so that they can continue functioning their daily activities. At the onset of the project, a set of functional and design requirements has been formulated with an extensive end-user involvement and then used in realizing the FB-AXO. The final FB-AXO design comprises of 27 degrees of freedom, of which 10 are active and 17 are passive, having a total system weight of 25 kg. Overall, the article elaborates comprehensively the design, construction, and preliminary testing of FB-AXO. The work effectively addresses design challenges including kinematic compatibility and modularity with innovative solutions. The details of the mechanics, sensors, and electronics of the two subsystems along with specifics of human-exoskeleton interfaces and ranges of motion are also provided. The FB-AXO exoskeleton effectively demonstrated to assist full-body motions such as normal walking, standing, bending as well as executing lifting and carrying tasks to meet the daily living demands of older users.
- Open Access
- 1 September 2020
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 17 (5)
Comparative study of knee joint torque estimations for linear and rotary actuators using bond graph approach for stand–sit–stand motions
Stand–sit–stand (STS) motions are the most frequently performed activities of everyday life and require extensive movement of knee joint. People suffering from knee joint disorders face difficulties in performing this motion. The compact knee exoskeleton (KE) has proven to be a viable, less complex, and cheaper alternative to the available entire lower-, upper-, and full-body exoskeletons. With growing number of technical glitches and finite battery life problems, there exist risks of sudden failure of the actuator of KE that could be detrimental for the vulnerable users. To overcome this problem, there is a need to accommodate a backup actuator in KE which can continue providing assistance during movement if the primary actuator ceases to function. This article provides a performance comparison of a four-bar mechanism-driven KE that can accommodate both the linear and the rotary actuators. The modelling and simulation of the system are performed using the bond graph (BG) technique. The results successfully showed that both actuators offered desired ranges of motions needed for STS motion. Furthermore, the knee joint torques developed by the linear and rotary actuators were found to be 40 Nm and 57 Nm, respectively, which corresponds to 60% and 85% of the total torque required by the knee joint to perform STS motions, thereby reducing the user effort to 40% and 15%, respectively. Thus, both actuators are self-capable to provide necessary assistance at the knee joint even if the primary actuator ceases to work due to a sudden fault, the secondary actuator will provide the required rotation of the thigh link and will continue to deliver the assistive torque. The article also effectively shows the application of BG approach to model the multidisciplinary systems like KE as it conveniently models the system containing various elements in different energy domains.
- 1 September 2020
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 17 (5)
Open AccessComparative study of knee joint torque estimations for linear and rotary actuators using bond graph approach for stand–sit–stand motions
Stand–sit–stand (STS) motions are the most frequently performed activities of everyday life and require extensive movement of knee joint. People suffering from knee joint disorders face difficulties in performing this motion. The compact knee exoskeleton (KE) has proven to be a viable, less complex, and cheaper alternative to the available entire lower-, upper-, and full-body exoskeletons. With growing number of technical glitches and finite battery life problems, there exist risks of sudden failure of the actuator of KE that could be detrimental for the vulnerable users. To overcome this problem, there is a need to accommodate a backup actuator in KE which can continue providing assistance during movement if the primary actuator ceases to function. This article provides a performance comparison of a four-bar mechanism-driven KE that can accommodate both the linear and the rotary actuators. The modelling and simulation of the system are performed using the bond graph (BG) technique. The results successfully showed that both actuators offered desired ranges of motions needed for STS motion. Furthermore, the knee joint torques developed by the linear and rotary actuators were found to be 40 Nm and 57 Nm, respectively, which corresponds to 60% and 85% of the total torque required by the knee joint to perform STS motions, thereby reducing the user effort to 40% and 15%, respectively. Thus, both actuators are self-capable to provide necessary assistance at the knee joint even if the primary actuator ceases to work due to a sudden fault, the secondary actuator will provide the required rotation of the thigh link and will continue to deliver the assistive torque. The article also effectively shows the application of BG approach to model the multidisciplinary systems like KE as it conveniently models the system containing various elements in different energy domains.
- 5 November 2017
- Published by Springer Nature
- p. 87-121
A Theoretical Analysis of an ‘Electromechanical’ Beam Tuned Mass Damper
- 5 November 2017
- Published by Springer Nature
- p. 87-121
A Theoretical Analysis of an ‘Electromechanical’ Beam Tuned Mass Damper
- 5 November 2017
- Published by Springer Nature
- p. 59-85
Modelling of Energy Harvesting Beams Using Dynamic Stiffness Method (DSM)
- 5 November 2017
- Published by Springer Nature
- p. 59-85
Modelling of Energy Harvesting Beams Using Dynamic Stiffness Method (DSM)
- 5 November 2017
- Published by Springer Nature
- p. 1-8
Introduction
- 5 November 2017
- Published by Springer Nature
- p. 123-140
Experimental Study of an Energy Harvesting Beam-Tuned Mass Damper
- 5 November 2017
- Published by Springer Nature
- p. 123-140
Experimental Study of an Energy Harvesting Beam-Tuned Mass Damper