Stephen Florczyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Stephen Florczyk has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Miqin Zhang
Department of Materials Science and Engineering, University of Washington, Seattle, WA 98195, USA
13 shared publications - Forrest M. Kievit
Department of Biological Systems Engineering, University of Nebraska — Lincoln, Lincoln, USA
7 shared publications Kui Wang
Department of Materials Science & Engineering, University of Washington, Seattle, USA
6 shared publicationsKailei Xu
Department of Materials Science and Engineering University of Central Florida Orlando Florida USA
4 shared publications- Carl Simon Shelley
Leukemia Therapeutics, LLC, Hull, USA
3 shared publications Mary L. Disis
Department of Medicine, University of Washington, Seattle, Washington 98109
3 shared publications
Latest Publications
- 3 April 2021
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 109 (10) , 1990-2000
Evaluation of the effect of 3D porous Chitosan‐alginate scaffold stiffness on breast cancer proliferation and migration
Breast cancer (BCa) is one of the most common cancers for women and metastatic BCa causes the majority of deaths. The extracellular matrix (ECM) stiffens during cancer progression and provides biophysical signals to modulate proliferation, morphology, and metastasis. Cells utilize mechanotransduction and integrins to sense and respond to ECM stiffness. Chitosan‐alginate (CA) scaffolds have been used for 3D culture, but lack integrin binding ligands, resulting in round cell morphology and limited cell‐material interaction. In this study, 2, 4, and 6 wt% CA scaffolds were produced to mimic the stages of BCa progression and evaluate the BCa response to CA scaffold stiffness. All three CA scaffold compositions highly porous with interconnected pores and scaffold stiffness increased with increasing polymer concentration. MDA‐MB‐231 (231) cells were cultured in CA scaffolds and 2D cultures for 7 d. All CA scaffold cultures had similar cell numbers at 7 d and the 231 cells formed clusters that increased in size during the culture. The 2 wt% CA had the largest clusters throughout the 7 d culture compared with the 4 and 6 wt% CA. The 231 cell migration was evaluated on 2D surfaces after 7 d culture. The 6 wt% CA cultured cells had the greatest migration speed, followed by 4 wt% CA, 2D cultures, and 2 wt% CA. These results suggest that 231 cells sensed the stiffness of CA scaffolds without the presence of focal adhesions. This indicates that a non‐integrin‐based mechanism may explain the observed mechanotransduction response.
- 3 April 2021
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 109 (10) , 1990-2000
Evaluation of the effect of 3D porous Chitosan‐alginate scaffold stiffness on breast cancer proliferation and migration
Breast cancer (BCa) is one of the most common cancers for women and metastatic BCa causes the majority of deaths. The extracellular matrix (ECM) stiffens during cancer progression and provides biophysical signals to modulate proliferation, morphology, and metastasis. Cells utilize mechanotransduction and integrins to sense and respond to ECM stiffness. Chitosan‐alginate (CA) scaffolds have been used for 3D culture, but lack integrin binding ligands, resulting in round cell morphology and limited cell‐material interaction. In this study, 2, 4, and 6 wt% CA scaffolds were produced to mimic the stages of BCa progression and evaluate the BCa response to CA scaffold stiffness. All three CA scaffold compositions highly porous with interconnected pores and scaffold stiffness increased with increasing polymer concentration. MDA‐MB‐231 (231) cells were cultured in CA scaffolds and 2D cultures for 7 d. All CA scaffold cultures had similar cell numbers at 7 d and the 231 cells formed clusters that increased in size during the culture. The 2 wt% CA had the largest clusters throughout the 7 d culture compared with the 4 and 6 wt% CA. The 231 cell migration was evaluated on 2D surfaces after 7 d culture. The 6 wt% CA cultured cells had the greatest migration speed, followed by 4 wt% CA, 2D cultures, and 2 wt% CA. These results suggest that 231 cells sensed the stiffness of CA scaffolds without the presence of focal adhesions. This indicates that a non‐integrin‐based mechanism may explain the observed mechanotransduction response.
- 1 September 2020
- Published by Elsevier in Biomaterials
- Vol. 254, 120126
3D porous chitosan-chondroitin sulfate scaffolds promote epithelial to mesenchymal transition in prostate cancer cells
- 1 September 2020
- Published by Elsevier in Biomaterials
- Vol. 254, 120126
3D porous chitosan-chondroitin sulfate scaffolds promote epithelial to mesenchymal transition in prostate cancer cells
- Open Access
Freeze-FRESH: A 3D Printing Technique to Produce Biomaterial Scaffolds with Hierarchical Porosity
Tissues are organized in hierarchical structures comprised of nanoscale, microscale, and macroscale features. Incorporating hierarchical structures into biomaterial scaffolds may enable better resemblance of native tissue structures and improve cell interaction, but it is challenging to produce such scaffolds using a single conventional scaffold production technique. We developed the Freeze-FRESH (FF) technique that combines FRESH 3D printing (3DP) and freeze-casting to produce 3D printed scaffolds with microscale pores in the struts. FF scaffolds were produced by extrusion 3DP using a support bath at room temperature, followed by freezing and lyophilization, then the FF scaffolds were recovered from the bath and crosslinked. The FF scaffolds had a hierarchical pore structure from the combination of microscale pores throughout the scaffold struts and macroscale pores in the printed design, while control scaffolds had only macroscale pores. FF scaffolds frozen at −20 °C and −80 °C had similar pore sizes, due to freezing in the support bath. The −20 °C and −80 °C FF scaffolds had porous struts with 63.55% ± 2.59% and 56.72% ± 13.17% strut porosity, respectively, while control scaffolds had a strut porosity of 3.15% ± 2.20%. The −20 °C and −80 °C FF scaffolds were softer than control scaffolds: they had pore wall stiffness of 0.17 ± 0.06 MPa and 0.23 ± 0.05 MPa, respectively, compared to 1.31 ± 0.39 MPa for the control. The FF scaffolds had increased resilience in bending compared with control. FF scaffolds supported MDA-MB-231 cell growth and had significantly greater cell numbers than control scaffolds. Cells formed clusters on the porous struts of FF scaffolds and had similar morphologies as the freeze cast scaffolds. The FF technique successfully introduced microscale porosity into the 3DP scaffold struts to produce hierarchical pore structures that enhanced MDA-MB-231 growth.
Open AccessFreeze-FRESH: A 3D Printing Technique to Produce Biomaterial Scaffolds with Hierarchical Porosity
Tissues are organized in hierarchical structures comprised of nanoscale, microscale, and macroscale features. Incorporating hierarchical structures into biomaterial scaffolds may enable better resemblance of native tissue structures and improve cell interaction, but it is challenging to produce such scaffolds using a single conventional scaffold production technique. We developed the Freeze-FRESH (FF) technique that combines FRESH 3D printing (3DP) and freeze-casting to produce 3D printed scaffolds with microscale pores in the struts. FF scaffolds were produced by extrusion 3DP using a support bath at room temperature, followed by freezing and lyophilization, then the FF scaffolds were recovered from the bath and crosslinked. The FF scaffolds had a hierarchical pore structure from the combination of microscale pores throughout the scaffold struts and macroscale pores in the printed design, while control scaffolds had only macroscale pores. FF scaffolds frozen at −20 °C and −80 °C had similar pore sizes, due to freezing in the support bath. The −20 °C and −80 °C FF scaffolds had porous struts with 63.55% ± 2.59% and 56.72% ± 13.17% strut porosity, respectively, while control scaffolds had a strut porosity of 3.15% ± 2.20%. The −20 °C and −80 °C FF scaffolds were softer than control scaffolds: they had pore wall stiffness of 0.17 ± 0.06 MPa and 0.23 ± 0.05 MPa, respectively, compared to 1.31 ± 0.39 MPa for the control. The FF scaffolds had increased resilience in bending compared with control. FF scaffolds supported MDA-MB-231 cell growth and had significantly greater cell numbers than control scaffolds. Cells formed clusters on the porous struts of FF scaffolds and had similar morphologies as the freeze cast scaffolds. The FF technique successfully introduced microscale porosity into the 3DP scaffold struts to produce hierarchical pore structures that enhanced MDA-MB-231 growth.
- 25 October 2019
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 48 (3) , 1090-1102
Effect of Mold Geometry on Pore Size in Freeze-Cast Chitosan-Alginate Scaffolds for Tissue Engineering
Freeze-casting is a popular method to produce biomaterial scaffolds with highly porous structures. The pore structure of freeze-cast biomaterial scaffolds is influenced by processing parameters but has mostly been controlled experimentally. A mathematical model integrating Computational Fluid Dynamics with Population Balance Model was developed to predict average pore size (APS) of 3D porous chitosan-alginate scaffolds and to assess the influence of the geometrical parameters of mold on scaffold pore structure. The model predicted the crystallization pattern and APS for scaffolds cast in different diameter molds and filled to different heights. The predictions demonstrated that the temperature gradient and solidification pattern affect ice crystal nucleation and growth, subsequently influencing APS homogeneity. The predicted APS compared favorably with APS measurements from a corresponding experimental dataset, validating the model. Sensitivity analysis was performed to assess the response of the APS to the three geometrical parameters of the mold: well radius; solution fill height; and spacing between wells. The pore size was most sensitive to the distance between the wells and least sensitive to solution height. This validated model demonstrates a method for optimizing the APS of freeze-cast biomaterial scaffolds that could be applied to other compositions or applications.
- 25 October 2019
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 48 (3) , 1090-1102
Effect of Mold Geometry on Pore Size in Freeze-Cast Chitosan-Alginate Scaffolds for Tissue Engineering
Freeze-casting is a popular method to produce biomaterial scaffolds with highly porous structures. The pore structure of freeze-cast biomaterial scaffolds is influenced by processing parameters but has mostly been controlled experimentally. A mathematical model integrating Computational Fluid Dynamics with Population Balance Model was developed to predict average pore size (APS) of 3D porous chitosan-alginate scaffolds and to assess the influence of the geometrical parameters of mold on scaffold pore structure. The model predicted the crystallization pattern and APS for scaffolds cast in different diameter molds and filled to different heights. The predictions demonstrated that the temperature gradient and solidification pattern affect ice crystal nucleation and growth, subsequently influencing APS homogeneity. The predicted APS compared favorably with APS measurements from a corresponding experimental dataset, validating the model. Sensitivity analysis was performed to assess the response of the APS to the three geometrical parameters of the mold: well radius; solution fill height; and spacing between wells. The pore size was most sensitive to the distance between the wells and least sensitive to solution height. This validated model demonstrates a method for optimizing the APS of freeze-cast biomaterial scaffolds that could be applied to other compositions or applications.
- 1 October 2019
- Published by Elsevier in Biomaterials
- Vol. 217, 119311
3D porous chitosan-alginate scaffold stiffness promotes differential responses in prostate cancer cell lines
- 1 October 2019
- Published by Elsevier in Biomaterials
- Vol. 217, 119311
3D porous chitosan-alginate scaffold stiffness promotes differential responses in prostate cancer cell lines
- Open Access
- 19 October 2018
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 9 (4) , 59
Direct-Contact Cytotoxicity Evaluation of CoCrFeNi-Based Multi-Principal Element Alloys
Transition metal multi-principal element alloys (MPEAs) are novel alloys that may offer enhanced surface and mechanical properties compared with commercial metallic alloys. However, their biocompatibility has not been investigated. In this study, three CoCrFeNi-based MPEAs were fabricated, and the in vitro cytotoxicity was evaluated in direct contact with fibroblasts for 168 h. The cell viability and cell number were assessed at 24, 96, and 168 h using LIVE/DEAD assay and alamarBlue assay, respectively. All MPEA sample wells had a high percentage of viable cells at each time point. The two quaternary MPEAs demonstrated a similar cell response to stainless steel control with the alamarBlue assay, while the quinary MPEA with Mn had a lower cell number after 168 h. Fibroblasts cultured with the MPEA samples demonstrated a consistent elongated morphology, while those cultured with the Ni control samples demonstrated changes in cell morphology after 24 h. No significant surface corrosion was observed on the MPEAs or stainless steel samples following the cell culture, while the Ni control samples had extensive corrosion. The cell growth and viability results demonstrate the cytocompatibility of the MPEAs. The biocompatibility of MPEAs should be investigated further to determine if MPEAs may be utilized in orthopedic implants and other biomedical applications.
- 19 October 2018
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 9 (4) , 59
Open AccessDirect-Contact Cytotoxicity Evaluation of CoCrFeNi-Based Multi-Principal Element Alloys
Transition metal multi-principal element alloys (MPEAs) are novel alloys that may offer enhanced surface and mechanical properties compared with commercial metallic alloys. However, their biocompatibility has not been investigated. In this study, three CoCrFeNi-based MPEAs were fabricated, and the in vitro cytotoxicity was evaluated in direct contact with fibroblasts for 168 h. The cell viability and cell number were assessed at 24, 96, and 168 h using LIVE/DEAD assay and alamarBlue assay, respectively. All MPEA sample wells had a high percentage of viable cells at each time point. The two quaternary MPEAs demonstrated a similar cell response to stainless steel control with the alamarBlue assay, while the quinary MPEA with Mn had a lower cell number after 168 h. Fibroblasts cultured with the MPEA samples demonstrated a consistent elongated morphology, while those cultured with the Ni control samples demonstrated changes in cell morphology after 24 h. No significant surface corrosion was observed on the MPEAs or stainless steel samples following the cell culture, while the Ni control samples had extensive corrosion. The cell growth and viability results demonstrate the cytocompatibility of the MPEAs. The biocompatibility of MPEAs should be investigated further to determine if MPEAs may be utilized in orthopedic implants and other biomedical applications.
- Open Access
- 28 November 2017
- Published by Springer Nature in BMC Bioinformatics
- Vol. 18 (1) , 526
Modeling, validation and verification of three-dimensional cell-scaffold contacts from terabyte-sized images
Cell-scaffold contact measurements are derived from pairs of co-registered volumetric fluorescent confocal laser scanning microscopy (CLSM) images (z-stacks) of stained cells and three types of scaffolds (i.e., spun coat, large microfiber, and medium microfiber). Our analysis of the acquired terabyte-sized collection is motivated by the need to understand the nature of the shape dimensionality (1D vs 2D vs 3D) of cell-scaffold interactions relevant to tissue engineers that grow cells on biomaterial scaffolds. We designed five statistical and three geometrical contact models, and then down-selected them to one from each category using a validation approach based on physically orthogonal measurements to CLSM. The two selected models were applied to 414 z-stacks with three scaffold types and all contact results were visually verified. A planar geometrical model for the spun coat scaffold type was validated from atomic force microscopy images by computing surface roughness of 52.35 nm ±31.76 nm which was 2 to 8 times smaller than the CLSM resolution. A cylindrical model for fiber scaffolds was validated from multi-view 2D scanning electron microscopy (SEM) images. The fiber scaffold segmentation error was assessed by comparing fiber diameters from SEM and CLSM to be between 0.46% to 3.8% of the SEM reference values. For contact verification, we constructed a web-based visual verification system with 414 pairs of images with cells and their segmentation results, and with 4968 movies with animated cell, scaffold, and contact overlays. Based on visual verification by three experts, we report the accuracy of cell segmentation to be 96.4% with 94.3% precision, and the accuracy of cell-scaffold contact for a statistical model to be 62.6% with 76.7% precision and for a geometrical model to be 93.5% with 87.6% precision. The novelty of our approach lies in (1) representing cell-scaffold contact sites with statistical intensity and geometrical shape models, (2) designing a methodology for validating 3D geometrical contact models and (3) devising a mechanism for visual verification of hundreds of 3D measurements. The raw and processed data are publicly available from https://isg.nist.gov/deepzoomweb/data/ together with the web -based verification system.
- 28 November 2017
- Published by Springer Nature in BMC Bioinformatics
- Vol. 18 (1) , 526
Open AccessModeling, validation and verification of three-dimensional cell-scaffold contacts from terabyte-sized images
Cell-scaffold contact measurements are derived from pairs of co-registered volumetric fluorescent confocal laser scanning microscopy (CLSM) images (z-stacks) of stained cells and three types of scaffolds (i.e., spun coat, large microfiber, and medium microfiber). Our analysis of the acquired terabyte-sized collection is motivated by the need to understand the nature of the shape dimensionality (1D vs 2D vs 3D) of cell-scaffold interactions relevant to tissue engineers that grow cells on biomaterial scaffolds. We designed five statistical and three geometrical contact models, and then down-selected them to one from each category using a validation approach based on physically orthogonal measurements to CLSM. The two selected models were applied to 414 z-stacks with three scaffold types and all contact results were visually verified. A planar geometrical model for the spun coat scaffold type was validated from atomic force microscopy images by computing surface roughness of 52.35 nm ±31.76 nm which was 2 to 8 times smaller than the CLSM resolution. A cylindrical model for fiber scaffolds was validated from multi-view 2D scanning electron microscopy (SEM) images. The fiber scaffold segmentation error was assessed by comparing fiber diameters from SEM and CLSM to be between 0.46% to 3.8% of the SEM reference values. For contact verification, we constructed a web-based visual verification system with 414 pairs of images with cells and their segmentation results, and with 4968 movies with animated cell, scaffold, and contact overlays. Based on visual verification by three experts, we report the accuracy of cell segmentation to be 96.4% with 94.3% precision, and the accuracy of cell-scaffold contact for a statistical model to be 62.6% with 76.7% precision and for a geometrical model to be 93.5% with 87.6% precision. The novelty of our approach lies in (1) representing cell-scaffold contact sites with statistical intensity and geometrical shape models, (2) designing a methodology for validating 3D geometrical contact models and (3) devising a mechanism for visual verification of hundreds of 3D measurements. The raw and processed data are publicly available from https://isg.nist.gov/deepzoomweb/data/ together with the web -based verification system.
- 19 September 2017
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 3 (10) , 2302-2313
A Bioinformatics 3D Cellular Morphotyping Strategy for Assessing Biomaterial Scaffold Niches
Many biomaterial scaffolds have been advanced to provide synthetic cell niches for tissue engineering and drug screening applications; however, current methods for comparing scaffold niches focus on cell functional outcomes or attempt to normalize materials properties between different scaffold formats. We demonstrate a three-dimensional (3D) cellular morphotyping strategy for comparing biomaterial scaffold cell niches between different biomaterial scaffold formats. Primary human bone marrow stromal cells (hBMSCs) were cultured on 8 different biomaterial scaffolds, including fibrous scaffolds, hydrogels, and porous sponges, in 10 treatment groups to compare a variety of biomaterial scaffolds and cell morphologies. A bioinformatics approach was used to determine the 3D cellular morphotype for each treatment group by using 82 shape metrics to analyze approximately 1000 cells. We found that hBMSCs cultured on planar substrates yielded planar cell morphotypes, while those cultured in 3D scaffolds had elongated or equiaxial cellular morphotypes with greater height. Multivariate analysis was effective at distinguishing mean shapes of cells in flat substrates from cells in scaffolds, as was the metric L1-depth (the cell height along its shortest axis after aligning cells with a characteristic ellipsoid). The 3D cellular morphotyping technique enables direct comparison of cellular microenvironments between widely different types of scaffolds and design of scaffolds based on cell structure–function relationships.
- 19 September 2017
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 3 (10) , 2302-2313
A Bioinformatics 3D Cellular Morphotyping Strategy for Assessing Biomaterial Scaffold Niches
Many biomaterial scaffolds have been advanced to provide synthetic cell niches for tissue engineering and drug screening applications; however, current methods for comparing scaffold niches focus on cell functional outcomes or attempt to normalize materials properties between different scaffold formats. We demonstrate a three-dimensional (3D) cellular morphotyping strategy for comparing biomaterial scaffold cell niches between different biomaterial scaffold formats. Primary human bone marrow stromal cells (hBMSCs) were cultured on 8 different biomaterial scaffolds, including fibrous scaffolds, hydrogels, and porous sponges, in 10 treatment groups to compare a variety of biomaterial scaffolds and cell morphologies. A bioinformatics approach was used to determine the 3D cellular morphotype for each treatment group by using 82 shape metrics to analyze approximately 1000 cells. We found that hBMSCs cultured on planar substrates yielded planar cell morphotypes, while those cultured in 3D scaffolds had elongated or equiaxial cellular morphotypes with greater height. Multivariate analysis was effective at distinguishing mean shapes of cells in flat substrates from cells in scaffolds, as was the metric L1-depth (the cell height along its shortest axis after aligning cells with a characteristic ellipsoid). The 3D cellular morphotyping technique enables direct comparison of cellular microenvironments between widely different types of scaffolds and design of scaffolds based on cell structure–function relationships.
- 17 May 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (5) , 621-625
Periodically Patterned Au-TiO2 Heterostructures for Photoelectrochemical Sensor
Periodically patterned Au nanorods in TiO2 nanocavities (Au NRs@TiO2) were fabricated via magnetron sputtering followed by a thermal dewetting process. This innovative Au NRs@TiO2 heterostructure was used as a plasmonic sensing platform for photoelectrochemical detection of glucose and lactose. This Au NRs@TiO2 patterned heterostructure possesses superior sensing properties to other Au nanoparticle-based sensors because (i) localized surface plasmon resonance (LSPR) generated at Au/TiO2 interfaces enhanced sensitivity of glucose (lactose) amperometric detection; (ii) periodic Au nanocrystals in TiO2 nanocavities accelerated charge separation and transfer rate, especially under monochromatic blue light irradiation; (iii) discrete planar architectures comprising Au NRs immobilized on TiO2 substrates significantly improved stability and reusability of the sensors. A low detection limit of 1 μM (10 μM) and a high sensitivity of 812 μA mM–1 cm–2 (270 μA mM–1 cm–2) were achieved on the Au NRs@TiO2 heterostructures for glucose (lactose) detection without the addition of enzymes. Good selectivity and superb stability over more than 8 weeks was also demonstrated using these Au NRs@TiO2 heterostructures for glucose (lactose) detection. Additionally, this cost-efficient technique can be easily extended to other photoelectrochemical sensing systems when considering the combination of sensing and visible or infrared light source enhancement.
- 17 May 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (5) , 621-625
Periodically Patterned Au-TiO2 Heterostructures for Photoelectrochemical Sensor
Periodically patterned Au nanorods in TiO2 nanocavities (Au NRs@TiO2) were fabricated via magnetron sputtering followed by a thermal dewetting process. This innovative Au NRs@TiO2 heterostructure was used as a plasmonic sensing platform for photoelectrochemical detection of glucose and lactose. This Au NRs@TiO2 patterned heterostructure possesses superior sensing properties to other Au nanoparticle-based sensors because (i) localized surface plasmon resonance (LSPR) generated at Au/TiO2 interfaces enhanced sensitivity of glucose (lactose) amperometric detection; (ii) periodic Au nanocrystals in TiO2 nanocavities accelerated charge separation and transfer rate, especially under monochromatic blue light irradiation; (iii) discrete planar architectures comprising Au NRs immobilized on TiO2 substrates significantly improved stability and reusability of the sensors. A low detection limit of 1 μM (10 μM) and a high sensitivity of 812 μA mM–1 cm–2 (270 μA mM–1 cm–2) were achieved on the Au NRs@TiO2 heterostructures for glucose (lactose) detection without the addition of enzymes. Good selectivity and superb stability over more than 8 weeks was also demonstrated using these Au NRs@TiO2 heterostructures for glucose (lactose) detection. Additionally, this cost-efficient technique can be easily extended to other photoelectrochemical sensing systems when considering the combination of sensing and visible or infrared light source enhancement.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3951-3953
Modeling, validation and verification of cell-scaffold contact measurements over terabyte-sized 3D image collection
This poster presents the problem of 3D contact measurements from two co-registered volumetric images (z-stacks). The 3D contact measurement consists of (a) segmenting an object of interest in each z-stack, (b) computing the relative spatial positions of the detected objects to detect contacts, (c) validating the accuracy of segmentation, and (d) visually verifying correct contact detection. The 3D measurement has to overcome challenges related to (1) intensity bleed-through across co-registered volumes, (2) insufficient knowledge about statistics and geometry of objects, (3) large RAM requirements (~3GB just to load the input data) and data volume (>1TB), and (4) complexity of 3D visual inspection.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3951-3953
Modeling, validation and verification of cell-scaffold contact measurements over terabyte-sized 3D image collection
This poster presents the problem of 3D contact measurements from two co-registered volumetric images (z-stacks). The 3D contact measurement consists of (a) segmenting an object of interest in each z-stack, (b) computing the relative spatial positions of the detected objects to detect contacts, (c) validating the accuracy of segmentation, and (d) visually verifying correct contact detection. The 3D measurement has to overcome challenges related to (1) intensity bleed-through across co-registered volumes, (2) insufficient knowledge about statistics and geometry of objects, (3) large RAM requirements (~3GB just to load the input data) and data volume (>1TB), and (4) complexity of 3D visual inspection.