Krzysztof Gromysz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Krzysztof Gromysz has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Mateusz Smolana
Silesian University of Technology
3 shared publications - Damian Słota
Department of Mathematical Methods in Technology and Computer Science, Silesian University of Technology, Kaszubska 23, 44-100, Gliwice, Poland.
2 shared publications Agnieszka Tanistra-Rozanowska
Auschwitz-Birkenau State Museum, Master Plan for Preservation, ul. Więźniów Oświęcimia 20, 32-603 Poland
1 shared publication- Edyta Hetmaniok
Department of Mathematics Applications and Methods for Artificial Intelligence, Faculty of Applied Mathematics, Silesian University of Technology, 44-100 Gliwice, Poland
1 shared publication Ewa Cyrulik
Auschwitz-Birkenau State Museum, Master Plan for Preservation, ul. Więźniów Oświęcimia 20, 32-603 Poland
1 shared publication- Jacek Kołodziej
Faculty of Civil Engineering, Silesian University of Technology, 5 Akademicka, 44-100 Gliwice, Poland
1 shared publication
Latest Publications
- 8 October 2026
- Published by Index Copernicus in Przegląd Budowlany
- Vol. 97 (5) , 124-128
Rektyfikacja znacznie wychylonego budynkujednorodzinnego
Przedstawiono sposób usunięcia wychylenia (rektyfikacji)całkowicie podpiwniczonego budynku jednorodzinnegoo dwóch kondygnacjach nadziemnych, którego wypadkowewychylenie wynosiło 95,2 mm/m. Wychylenie to uniemożliwiałoużytkowanie obiektu. Rektyfikacja została przeprowadzonaprzez nierównomierne podnoszenie za pomocą 31 siłownikówwbudowanych w ściany piwnic przy maksymalnym podnoszeniuwynoszącym 1314 mm. Ze względu na przyjętą technologięrektyfikacji w poziomie posadzki piwnic wykonano żelbetowąprzeponę. Jej rolą jest zmniejszenie wysokości mimośrodowoobciążonych ścian i przejmowanie sił poziomych. W trakcie rektyfikacjizmierzono wysuw tłoków siłowników hydraulicznych orazwartości sił w siłownikach. Po przeprowadzeniu prac zwiększeniuuległa wysokość pomieszczeń piwnicznych, a po niwelacjiterenu budynek stał się obiektem o trzech kondygnacjach naziemnych,co umożliwiło jego przeznaczenie na cele mieszkalno-biurowe. Prace przywróciły obiektowi pełną funkcjonalnośći zwiększyły jego wartość. W artykule przeanalizowano także pomiarywysuwów tłoków oraz wartości sił w siłownikach zrealizowanepodczas rektyfikacji.
- 8 October 2026
- Published by Index Copernicus in Przegląd Budowlany
- Vol. 97 (5) , 124-128
Rektyfikacja znacznie wychylonego budynkujednorodzinnego
Przedstawiono sposób usunięcia wychylenia (rektyfikacji)całkowicie podpiwniczonego budynku jednorodzinnegoo dwóch kondygnacjach nadziemnych, którego wypadkowewychylenie wynosiło 95,2 mm/m. Wychylenie to uniemożliwiałoużytkowanie obiektu. Rektyfikacja została przeprowadzonaprzez nierównomierne podnoszenie za pomocą 31 siłownikówwbudowanych w ściany piwnic przy maksymalnym podnoszeniuwynoszącym 1314 mm. Ze względu na przyjętą technologięrektyfikacji w poziomie posadzki piwnic wykonano żelbetowąprzeponę. Jej rolą jest zmniejszenie wysokości mimośrodowoobciążonych ścian i przejmowanie sił poziomych. W trakcie rektyfikacjizmierzono wysuw tłoków siłowników hydraulicznych orazwartości sił w siłownikach. Po przeprowadzeniu prac zwiększeniuuległa wysokość pomieszczeń piwnicznych, a po niwelacjiterenu budynek stał się obiektem o trzech kondygnacjach naziemnych,co umożliwiło jego przeznaczenie na cele mieszkalno-biurowe. Prace przywróciły obiektowi pełną funkcjonalnośći zwiększyły jego wartość. W artykule przeanalizowano także pomiarywysuwów tłoków oraz wartości sił w siłownikach zrealizowanepodczas rektyfikacji.
- Open Access
Research on the Characteristics of Jacks Used to Rectify Tilted Buildings
One method of rectifying tilted buildings is by lifting them unevenly using hydraulic jacks. These jacks are loaded both monotonically and cyclically during the rectification process. It has been shown that the change in jack length is the sum of the change in the piston slide out and the change in the jack’s cylinder length, which is supported by a parallelepiped element. Laboratory tests were conducted to investigate the piston slide out and the change in the jack’s cylinder length under both monotonically and cyclically loaded conditions. The results indicated that the piston slide out forms a hysteresis loop. In contrast, the change in the jack’s cylinder length does not exhibit a hysteresis loop and is a non-linear function of the load. A structural model of the jack was proposed, consisting of three components: a linearly elastic component connected in parallel to the component where the frictional force occurs, and a component with non-linear elastic characteristics connected in series with them. Displacements of the linear elastic component, characterized by a constant stiffness, occur as long as the external load exceeds the internal frictional force. The value of the frictional force in this model increases with the load. The stiffness of the non-linear elastic component increases proportionally to the load.
Open AccessResearch on the Characteristics of Jacks Used to Rectify Tilted Buildings
One method of rectifying tilted buildings is by lifting them unevenly using hydraulic jacks. These jacks are loaded both monotonically and cyclically during the rectification process. It has been shown that the change in jack length is the sum of the change in the piston slide out and the change in the jack’s cylinder length, which is supported by a parallelepiped element. Laboratory tests were conducted to investigate the piston slide out and the change in the jack’s cylinder length under both monotonically and cyclically loaded conditions. The results indicated that the piston slide out forms a hysteresis loop. In contrast, the change in the jack’s cylinder length does not exhibit a hysteresis loop and is a non-linear function of the load. A structural model of the jack was proposed, consisting of three components: a linearly elastic component connected in parallel to the component where the frictional force occurs, and a component with non-linear elastic characteristics connected in series with them. Displacements of the linear elastic component, characterized by a constant stiffness, occur as long as the external load exceeds the internal frictional force. The value of the frictional force in this model increases with the load. The stiffness of the non-linear elastic component increases proportionally to the load.
- Open Access
- 1 December 2023
- Published by Walter de Gruyter GmbH in Architecture, Civil Engineering, Environment
- Vol. 16 (4) , 79-92
Reliable Tilt of Objects Subjected to Rectification and Located in Mining Areas
Mining exploitation of hard coal is conducted in the Silesian region in Poland. As a result, the post-mining void is formed which leads to non-uniform lowering of the ground level. Consequently, thousands of buildings are vertically deflected. This type of deflection causes troublesome use of buildings, underestimates their value, and in extreme situations leads to exceeded limit states. Therefore, such buildings are rectified by non-uniform elevations by means of jacks. On the basis of the analysed rectification processes, the method of determining the deflection of a building and the height of elevating its corners were presented depending on the type of building. This paper is a review of methods of determining the deflection of buildings having different sizes: single-storey buildings, single-storey buildings with a usable attic, two-storey buildings, and 11-storey buildings. Moreover, specific situations were analysed, in which the elevation height was determined by a range of additional works performed during rectification. This review was used to develop guidelines for determining deflection values and specifying the height of non-uniform elevation of corners.
- 1 December 2023
- Published by Walter de Gruyter GmbH in Architecture, Civil Engineering, Environment
- Vol. 16 (4) , 79-92
Open AccessReliable Tilt of Objects Subjected to Rectification and Located in Mining Areas
Mining exploitation of hard coal is conducted in the Silesian region in Poland. As a result, the post-mining void is formed which leads to non-uniform lowering of the ground level. Consequently, thousands of buildings are vertically deflected. This type of deflection causes troublesome use of buildings, underestimates their value, and in extreme situations leads to exceeded limit states. Therefore, such buildings are rectified by non-uniform elevations by means of jacks. On the basis of the analysed rectification processes, the method of determining the deflection of a building and the height of elevating its corners were presented depending on the type of building. This paper is a review of methods of determining the deflection of buildings having different sizes: single-storey buildings, single-storey buildings with a usable attic, two-storey buildings, and 11-storey buildings. Moreover, specific situations were analysed, in which the elevation height was determined by a range of additional works performed during rectification. This review was used to develop guidelines for determining deflection values and specifying the height of non-uniform elevation of corners.
- 30 September 2023
- Published by Index Copernicus in Inżynieria i Budownictwo
- Vol. LXXIX (9-10) , 516-521
Analysis of the possibility of rectification of the wall of the historical barrack B-138 located in the KL Auschwitz-Birkenau
- 30 September 2023
- Published by Index Copernicus in Inżynieria i Budownictwo
- Vol. LXXIX (9-10) , 516-521
Analysis of the possibility of rectification of the wall of the historical barrack B-138 located in the KL Auschwitz-Birkenau
- Open Access
- 4 April 2023
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 69 (1) , 259-270
Analysis of deflections of reinforced concrete slab in the rectified water-storage tank
The presented analysis concerns deflections of the reinforced concrete slab in the fire-fighting water storage tank with volume of 950 m 3. It was built on human-altered soil which led to deflection of the tank. When water was pumped out from the tank, rectification was performed. The tank and its slab foundation were non-uniformly elevated by means of hydraulic jacks. These jacks were installed under the slab, on foundation made of concrete block stacks, which were pressed into the ground. The computational analysis was conducted for displacements and deflections of the slab supported on the jacks. The number of jacks under the slab and stiffness of jack supports on the stacks were the variable parameters of the model. Stiffness of the jack supports was found to have non-significant impact on deflections of the foundation slab of the rectified tank. On the other hand, the number of jacks under the tank affected both deflections of the slab and displacements of the whole tank. The greatest deflection of the tank slab supported on three jacks was 15.233 mm, and the smallest one was 10.435 mm at 32 jacks.
- 4 April 2023
- Published by Polish Academy of Sciences Chancellery in Archives of Civil Engineering
- Vol. 69 (1) , 259-270
Open AccessAnalysis of deflections of reinforced concrete slab in the rectified water-storage tank
The presented analysis concerns deflections of the reinforced concrete slab in the fire-fighting water storage tank with volume of 950 m 3. It was built on human-altered soil which led to deflection of the tank. When water was pumped out from the tank, rectification was performed. The tank and its slab foundation were non-uniformly elevated by means of hydraulic jacks. These jacks were installed under the slab, on foundation made of concrete block stacks, which were pressed into the ground. The computational analysis was conducted for displacements and deflections of the slab supported on the jacks. The number of jacks under the slab and stiffness of jack supports on the stacks were the variable parameters of the model. Stiffness of the jack supports was found to have non-significant impact on deflections of the foundation slab of the rectified tank. On the other hand, the number of jacks under the tank affected both deflections of the slab and displacements of the whole tank. The greatest deflection of the tank slab supported on three jacks was 15.233 mm, and the smallest one was 10.435 mm at 32 jacks.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2928 (1)
Analysis of causes of differential deflection of a building in the mining area
Deflection of buildings from vertical in mining areas is usually attributed to ground deformation caused by mining activities. However, when deflection of the building is disproportionately large compared to design deflections of the mining area, there are other causes than mining activities which are responsible for the observed damages. Identification of these causes is significant in relation to the mine liabilities, and mainly to the determination of safety use of a building and adequate procedure for damage. This paper describes an analysis of causes of differential deflection of the tenement on Podgórna Street in Bytom, Poland. Deflection causes were identified on the basis of analysed data concerning the impact of mining activities, conditions of a building foundation, and lateral measurements of the building deformations. The next part focuses on numerical calculations of a spatial model of the building, which were used to deduct the safe use and further procedure for the building. The building deflection was resolved into two components of uniform and differential deflection upon the analysis of the lateral measurement results. The uniform deflection to 10.2 mm/m to the north is seen as rotation of the body of the building. It is caused by inclination of the mining area. The second component – differential deflection of 17.7 mm/m to the north is caused by differential settlement of foundations. Deformations of the building underwent abrupt changes and were directly connected with its upward extension. The computational analysis conducted for the building shows that the currently observed deformation of the building has no significant impact on the stress state of the most deflected north wall of the building. As the building deflection is kept unchanged since the mining effects are no longer manifested, the building is considered to find a new balance position. However, ground under the northern part of the building did not meet requirements for building land. The building state can change as a result of local load, hydration, etc. Therefore, it is recommended to stabilise ground under the northern part of the building.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2928 (1)
Analysis of causes of differential deflection of a building in the mining area
Deflection of buildings from vertical in mining areas is usually attributed to ground deformation caused by mining activities. However, when deflection of the building is disproportionately large compared to design deflections of the mining area, there are other causes than mining activities which are responsible for the observed damages. Identification of these causes is significant in relation to the mine liabilities, and mainly to the determination of safety use of a building and adequate procedure for damage. This paper describes an analysis of causes of differential deflection of the tenement on Podgórna Street in Bytom, Poland. Deflection causes were identified on the basis of analysed data concerning the impact of mining activities, conditions of a building foundation, and lateral measurements of the building deformations. The next part focuses on numerical calculations of a spatial model of the building, which were used to deduct the safe use and further procedure for the building. The building deflection was resolved into two components of uniform and differential deflection upon the analysis of the lateral measurement results. The uniform deflection to 10.2 mm/m to the north is seen as rotation of the body of the building. It is caused by inclination of the mining area. The second component – differential deflection of 17.7 mm/m to the north is caused by differential settlement of foundations. Deformations of the building underwent abrupt changes and were directly connected with its upward extension. The computational analysis conducted for the building shows that the currently observed deformation of the building has no significant impact on the stress state of the most deflected north wall of the building. As the building deflection is kept unchanged since the mining effects are no longer manifested, the building is considered to find a new balance position. However, ground under the northern part of the building did not meet requirements for building land. The building state can change as a result of local load, hydration, etc. Therefore, it is recommended to stabilise ground under the northern part of the building.
- Open Access
Analysis of Parameters of a Rectified Tank on the Basis of In-Situ Tests
The vertical deflection of building structures is a common problem. However, the rectification of objects is rarely carried out due to the lack of information about the parameters of objects requiring rectification. The subject of the analysis are parameters of rectified water tank 950 m3 in volume, which were investigated due to the stiffness and number of supports built into the structure. During in-situ testing, the stiffnesses of supports were determined. The model of the rectified structure was then defined and it was shown that its parameters can be described by means of three matrices: stiffness, displacement forms of the elevated object and displacement forms of supports. Absolute values of elements of the stiffness matrix increased as the stiffness and number of supports increased. At the same time, values of elements of the matrix of displacement forms of the elevated object increased. The conducted energy analysis demonstrated that the amount of energy required for the vertical displacement of the structure decreased with an increasing stiffness and number of supports. This means that placing a greater number of supports under rectified structures and ensuring more rigid supports is beneficial to the rectification. Results of the conducted analyses were confirmed during in-situ tests.
Open AccessAnalysis of Parameters of a Rectified Tank on the Basis of In-Situ Tests
The vertical deflection of building structures is a common problem. However, the rectification of objects is rarely carried out due to the lack of information about the parameters of objects requiring rectification. The subject of the analysis are parameters of rectified water tank 950 m3 in volume, which were investigated due to the stiffness and number of supports built into the structure. During in-situ testing, the stiffnesses of supports were determined. The model of the rectified structure was then defined and it was shown that its parameters can be described by means of three matrices: stiffness, displacement forms of the elevated object and displacement forms of supports. Absolute values of elements of the stiffness matrix increased as the stiffness and number of supports increased. At the same time, values of elements of the matrix of displacement forms of the elevated object increased. The conducted energy analysis demonstrated that the amount of energy required for the vertical displacement of the structure decreased with an increasing stiffness and number of supports. This means that placing a greater number of supports under rectified structures and ensuring more rigid supports is beneficial to the rectification. Results of the conducted analyses were confirmed during in-situ tests.
- Open Access
An 18-Month Analysis of Bond Strength of Hot-Dip Galvanized Reinforcing Steel B500SP and S235JR+AR to Chloride Contaminated Concrete
This article describes the comparative analysis of tests on bond strength of hot-dip galvanized and black steel to concrete with and without chlorides. The bond effect was evaluated with six research methods: strength, electrochemical (measurements of potential, EIS and LPR), optical, and 3D scanning. The tests were conducted within a long period of 18 months on 48 test elements reinforced with smooth rebars ϕ8 mm from steel grade S235JR+AR and ribbed rebars ϕ8 mm and ϕ16 mm from steel grade B500SP. The main strength tests on the reinforcement bond to concrete were used to compare forces pulling out galvanized and black steel rebars from concrete. This comparative analysis was performed after 28, 180, and 540 days from the preparation of the elements. The electrochemical tests were performed to evaluate corrosion of steel rebars in concrete, particularly in chloride contaminated concrete. The behaviour of concrete elements while pulling out the rebar was observed using the system of digital cameras during the optical tests. As regards 3D scanning of ribbed rebars ϕ8 mm and ϕ16 mm, this method allowed the detailed identification of their complex geometry in terms of determining the polarization area to evaluate the corrosion rate of reinforcement in concrete. The test results indicated that the presence of zinc coating on rebars had an impact on the parameters of anchorage. In the case of ribbed rebars of 16 mm in diameter, the maximum values of adhesive stress and bond stiffness were reduced over time when compared to black steel rebars. Moreover, it was noticed that the stiffness of rebar anchorage in chloride contaminated concrete was considerably higher than in concrete without chlorides.
Open AccessAn 18-Month Analysis of Bond Strength of Hot-Dip Galvanized Reinforcing Steel B500SP and S235JR+AR to Chloride Contaminated Concrete
This article describes the comparative analysis of tests on bond strength of hot-dip galvanized and black steel to concrete with and without chlorides. The bond effect was evaluated with six research methods: strength, electrochemical (measurements of potential, EIS and LPR), optical, and 3D scanning. The tests were conducted within a long period of 18 months on 48 test elements reinforced with smooth rebars ϕ8 mm from steel grade S235JR+AR and ribbed rebars ϕ8 mm and ϕ16 mm from steel grade B500SP. The main strength tests on the reinforcement bond to concrete were used to compare forces pulling out galvanized and black steel rebars from concrete. This comparative analysis was performed after 28, 180, and 540 days from the preparation of the elements. The electrochemical tests were performed to evaluate corrosion of steel rebars in concrete, particularly in chloride contaminated concrete. The behaviour of concrete elements while pulling out the rebar was observed using the system of digital cameras during the optical tests. As regards 3D scanning of ribbed rebars ϕ8 mm and ϕ16 mm, this method allowed the detailed identification of their complex geometry in terms of determining the polarization area to evaluate the corrosion rate of reinforcement in concrete. The test results indicated that the presence of zinc coating on rebars had an impact on the parameters of anchorage. In the case of ribbed rebars of 16 mm in diameter, the maximum values of adhesive stress and bond stiffness were reduced over time when compared to black steel rebars. Moreover, it was noticed that the stiffness of rebar anchorage in chloride contaminated concrete was considerably higher than in concrete without chlorides.
- Open Access
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1781 (1) , 012024
A bar model of a temporary wooden support used to remove deflections of buildings
The deflection of buildings located in mining areas is removed by uneven raising of the overground part of the structure by means of supports consisting of a hydraulic piston jack and a stack of underpinning elements. Temporary supports may also consist of stacks of wooden elements only. The article presents a bar model of a temporary support consisting of a stack of elements. The model, which is described by a differential, second-order equation, allows to determine horizontal displacements. It was demonstrated that the unintended eccentricity and the initial curvature of the element have influence on such displacements. In addition, the effect of the load transmitted by the deformed adjacent supports is important. The model presented can be used to determine the limit load capacity of temporary supports due to unintended horizontal displacements of the structure. The model therefore allows to design safely the removal of building structures’ deflections.
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1781 (1) , 012024
Open AccessA bar model of a temporary wooden support used to remove deflections of buildings
The deflection of buildings located in mining areas is removed by uneven raising of the overground part of the structure by means of supports consisting of a hydraulic piston jack and a stack of underpinning elements. Temporary supports may also consist of stacks of wooden elements only. The article presents a bar model of a temporary support consisting of a stack of elements. The model, which is described by a differential, second-order equation, allows to determine horizontal displacements. It was demonstrated that the unintended eccentricity and the initial curvature of the element have influence on such displacements. In addition, the effect of the load transmitted by the deformed adjacent supports is important. The model presented can be used to determine the limit load capacity of temporary supports due to unintended horizontal displacements of the structure. The model therefore allows to design safely the removal of building structures’ deflections.
- Open Access
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 960 (3) , 032050
Examples of Even Lifting of Structural Elements of Existing Buildings
Two examples of even, vertical lifting of building elements are presented. In the first example, after the raw state of the building was completed, the concept of land development around the building has changed. It involved in particular elevating the ground level by 0.8 m. As a consequence, the entrance to the building would be below the surrounding land. It was decided to lift the above-ground part of the building evenly by 0.80 m in order to avoid this. The lifting of the above-ground part of the building was designed and executed by detaching the building apart at the level of the floor and then lifting it evenly by 0.8 m. For this purpose, eighteen hydraulic jacks were used, installed in the bearing walls in the previously made openings. New technical cellars were additionally constructed as a result of the works. In the second case, the roof truss was raised in the residential building in use. The usable area of the attic was enlarged as a result of the works and the number of posts limiting the freedom of interior design was reduced. In both cases, a system of hydraulic jacks was used to move the structure vertically. With the presented procedure, no damage was caused to both, the building elements that were lifted and those unmoved. In addition, the even lifting of parts of the building allowed to avoid the troublesome dismantling and then restoration in a new location.
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 960 (3) , 032050
Open AccessExamples of Even Lifting of Structural Elements of Existing Buildings
Two examples of even, vertical lifting of building elements are presented. In the first example, after the raw state of the building was completed, the concept of land development around the building has changed. It involved in particular elevating the ground level by 0.8 m. As a consequence, the entrance to the building would be below the surrounding land. It was decided to lift the above-ground part of the building evenly by 0.80 m in order to avoid this. The lifting of the above-ground part of the building was designed and executed by detaching the building apart at the level of the floor and then lifting it evenly by 0.8 m. For this purpose, eighteen hydraulic jacks were used, installed in the bearing walls in the previously made openings. New technical cellars were additionally constructed as a result of the works. In the second case, the roof truss was raised in the residential building in use. The usable area of the attic was enlarged as a result of the works and the number of posts limiting the freedom of interior design was reduced. In both cases, a system of hydraulic jacks was used to move the structure vertically. With the presented procedure, no damage was caused to both, the building elements that were lifted and those unmoved. In addition, the even lifting of parts of the building allowed to avoid the troublesome dismantling and then restoration in a new location.