Ibrahim Eldesouky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ibrahim Eldesouky has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Noha Fouda
Department of Production and Mechanical Design Engineering, Faculty of Engineering, Mansoura University, Mansoura, Egypt
5 shared publications - Tawakol Ahmed Enab
Production and Mechanical Design Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt.
3 shared publications - Basma Eltlhawy
Department of Mechatronics Engineering, Pyramids Higher Institute of Engineering and Technology, Giza, Egypt
2 shared publications Harvey West
B Center for Additive Manufacturing and Logistics, Edward P. Fitts Department of Industrial & Systems Engineering , North Carolina State University , Raleigh , NC , USA
2 shared publicationsHassan El-Hofy
A Department of Industrial Engineering and Systems Management , Egypt-Japan University of Science and Technology , New Borg Elarab , Egypt
2 shared publications- Ibrahim M. Hassan
Production Engineering and Mechanical Design Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt
2 shared publications
Latest Publications
- Open Access
- 20 October 2025
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 11 (1) , 83-94
Tribological and hardness characteristics of resin materials in masked stereolithography: impact of washing solution and curing time
Masked stereolithography (MSLA) has emerged as a prominent vat photopolymerization technique due to its high-dimensional precision and superior surface finish, making it particularly suitable for applications in engineering, dentistry, and biomedicine. This study examines the influence of post-processing parameters; specifically washing solvent and UV curing time; on the mechanical and tribological behavior of three commercial resins: ABS-like (ABS), High Tough Resin (HTR), and Crown & Bridge resin (CrBr). Post-processing involved three solvents; 70% ethyl alcohol (E70), 95% ethyl alcohol (E95), and isopropanol (IPA); combined with three curing durations (3, 5, and 10 min). Mechanical performance was evaluated using Vickers hardness testing, while wear and frictional behavior were assessed through mass loss and friction coefficient measurements. The highest hardness (13.23 HV) was observed for CrBr following 10 min of curing and washing with E95. HTR demonstrated the best tribological performance, exhibiting the lowest mass loss (0.35%) and friction coefficient (0.188) under 10 min of curing and IPA washing. Analysis of variance indicated that resin type significantly influenced all measured properties ( p < 0.001), while curing time and solvent type had a statistically significant effect on hardness only. Taguchi signal-to-noise ratio analysis supported these findings and helped identify optimal post-processing settings. These results underscore the critical role of resin chemistry and post-curing conditions in tailoring the functional performance of MSLA-fabricated components.
- 20 October 2025
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 11 (1) , 83-94
Open AccessTribological and hardness characteristics of resin materials in masked stereolithography: impact of washing solution and curing time
Masked stereolithography (MSLA) has emerged as a prominent vat photopolymerization technique due to its high-dimensional precision and superior surface finish, making it particularly suitable for applications in engineering, dentistry, and biomedicine. This study examines the influence of post-processing parameters; specifically washing solvent and UV curing time; on the mechanical and tribological behavior of three commercial resins: ABS-like (ABS), High Tough Resin (HTR), and Crown & Bridge resin (CrBr). Post-processing involved three solvents; 70% ethyl alcohol (E70), 95% ethyl alcohol (E95), and isopropanol (IPA); combined with three curing durations (3, 5, and 10 min). Mechanical performance was evaluated using Vickers hardness testing, while wear and frictional behavior were assessed through mass loss and friction coefficient measurements. The highest hardness (13.23 HV) was observed for CrBr following 10 min of curing and washing with E95. HTR demonstrated the best tribological performance, exhibiting the lowest mass loss (0.35%) and friction coefficient (0.188) under 10 min of curing and IPA washing. Analysis of variance indicated that resin type significantly influenced all measured properties ( p < 0.001), while curing time and solvent type had a statistically significant effect on hardness only. Taguchi signal-to-noise ratio analysis supported these findings and helped identify optimal post-processing settings. These results underscore the critical role of resin chemistry and post-curing conditions in tailoring the functional performance of MSLA-fabricated components.
- Open Access
- 18 May 2025
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 10 (10) , 8641-8652
Assessing the mechanical and energy absorption capabilities of lattice structures of F-RD and Fischer–Koch S triply periodic minimal surfaces
Lattice structures are lightweight, highly energy-absorbing, and have great thermal and acoustic insulation qualities. As a result, they have a high potential for use in the biomedical, safety, aerospace, and heat dissipation industries. The current research aims to study the mechanical performance and energy absorption levels of additively manufactured F-RD and Fischer–Koch S uniform lattice structures under compressive load and compare the results to their functionally graded counterparts. Sixteen triply periodic minimal surfaces (TPMS) samples were 3D printed using the masked stereolithography (MSLA) technique. Then, printing quality was assessed using a digital optical microscope. The samples were mechanically tested according to the ISO 13314 Standard. The resulting mechanical properties of relative modulus, first maximum compressive strength, plateau stress, and energy absorption were thoroughly compared between the four types. Graded Fischer–Koch S showed improved mechanical properties, followed by uniform Fischer–Koch S, and finally by graded and uniform F-RD. Regarding energy absorption, graded samples exhibited better results than uniform samples for each type. The results showed that Fischer–Koch S graded samples exhibited better performance, demonstrating their suitability as potential candidates for energy absorption applications.
- 18 May 2025
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 10 (10) , 8641-8652
Open AccessAssessing the mechanical and energy absorption capabilities of lattice structures of F-RD and Fischer–Koch S triply periodic minimal surfaces
Lattice structures are lightweight, highly energy-absorbing, and have great thermal and acoustic insulation qualities. As a result, they have a high potential for use in the biomedical, safety, aerospace, and heat dissipation industries. The current research aims to study the mechanical performance and energy absorption levels of additively manufactured F-RD and Fischer–Koch S uniform lattice structures under compressive load and compare the results to their functionally graded counterparts. Sixteen triply periodic minimal surfaces (TPMS) samples were 3D printed using the masked stereolithography (MSLA) technique. Then, printing quality was assessed using a digital optical microscope. The samples were mechanically tested according to the ISO 13314 Standard. The resulting mechanical properties of relative modulus, first maximum compressive strength, plateau stress, and energy absorption were thoroughly compared between the four types. Graded Fischer–Koch S showed improved mechanical properties, followed by uniform Fischer–Koch S, and finally by graded and uniform F-RD. Regarding energy absorption, graded samples exhibited better results than uniform samples for each type. The results showed that Fischer–Koch S graded samples exhibited better performance, demonstrating their suitability as potential candidates for energy absorption applications.
- 6 April 2025
- Published by Springer Nature in Meccanica
- Vol. 60 (4) , 999-1014
Static and dynamic performance of porous Ti6Al4V tibia implant designs based on triply periodic minimal surface scaffolds
- 6 April 2025
- Published by Springer Nature in Meccanica
- Vol. 60 (4) , 999-1014
Static and dynamic performance of porous Ti6Al4V tibia implant designs based on triply periodic minimal surface scaffolds
- Open Access
- 5 January 2023
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 45 (1) , 1-11
Design, fabrication, and evaluation of functionally graded triply periodic minimal surface structures fabricated by 3D printing
Cellular structures are a favorite selection for the design of lightweight components and energy absorption applications due to several advantages such as their customizable stiffness and strength. In this investigation, functionally graded (FG) triply periodic minimal surfaces, Schoen-IWP (SIWP), and Schwarz primitive (SPrim) cellular structures were fabricated by masked stereolithography (MSLA) technique using ABS-like gray resin. The sample morphology, deformation behavior, mechanical characteristics, and energy absorption of graded and uniform structures were studied using experimental compression tests. The FG sample structures exhibited layer-by-layer collapse delaying shear failure. On the other hand, uniform samples showed complete diagonal shear failure. The total energy absorption to the densification point was 0.52 MJ/m3 and 0.58 MJ/m3 for graded and uniform SIWP, respectively. Additionally, the absorbed energy of the graded SPrim structure was 0.59 MJ/m3 while the uniform one absorbed 0.27 MJ/m3. The investigations showed that the graded SPrim absorbed more energy with high densification strain during the compression test.
- 5 January 2023
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 45 (1) , 1-11
Open AccessDesign, fabrication, and evaluation of functionally graded triply periodic minimal surface structures fabricated by 3D printing
Cellular structures are a favorite selection for the design of lightweight components and energy absorption applications due to several advantages such as their customizable stiffness and strength. In this investigation, functionally graded (FG) triply periodic minimal surfaces, Schoen-IWP (SIWP), and Schwarz primitive (SPrim) cellular structures were fabricated by masked stereolithography (MSLA) technique using ABS-like gray resin. The sample morphology, deformation behavior, mechanical characteristics, and energy absorption of graded and uniform structures were studied using experimental compression tests. The FG sample structures exhibited layer-by-layer collapse delaying shear failure. On the other hand, uniform samples showed complete diagonal shear failure. The total energy absorption to the densification point was 0.52 MJ/m3 and 0.58 MJ/m3 for graded and uniform SIWP, respectively. Additionally, the absorbed energy of the graded SPrim structure was 0.59 MJ/m3 while the uniform one absorbed 0.27 MJ/m3. The investigations showed that the graded SPrim absorbed more energy with high densification strain during the compression test.
- 1 November 2022
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 8 (5) , 807-817
Numerical assessment of advanced porous tibia implant designs based on different cellular structures
- 1 November 2022
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 8 (5) , 807-817
Numerical assessment of advanced porous tibia implant designs based on different cellular structures
- 21 August 2022
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 8 (2) , 303-311
The mechanical performance of functionally graded Schwarz primitive and Schoen-IWP cellular structures fabricated by additive manufacturing
- 21 August 2022
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 8 (2) , 303-311
The mechanical performance of functionally graded Schwarz primitive and Schoen-IWP cellular structures fabricated by additive manufacturing
- 24 May 2021
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 318, 71-81
Finite Element Assessment of a Porous Tibial Implant Design Using Rhombic Dodecahedron Structure
The current research presents a novel porous tibia implant design based on porous structure. The implant proximal portion was designed as a porous rhombic dodecahedron structure with 500 μm pore size. Finite element method (FEM) was used to assess the stem behavior under compressive loading compared to a solid stem model. CATIA V5R18 was used for modeling both rhombic dodecahedron and full solid models. Static structural analysis was carried out using ANSYS R18.1 to asses the implant designs. The results indicated enhanced clinical performance of tibial-knee implants compared to the solid titanium implant via increasing the maximum von-Mises stresses by 64% under the tibial tray in porous implant which reduce stress shielding. Also, the maximum shear stress developed in bone/implant interface was reduced by 68% combined with relieving the stress concentration under the stem tip to relieve patients' pain. Finally, porous implants provide cavities for bone ingrowth which improve implant fixation.
- 24 May 2021
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 318, 71-81
Finite Element Assessment of a Porous Tibial Implant Design Using Rhombic Dodecahedron Structure
The current research presents a novel porous tibia implant design based on porous structure. The implant proximal portion was designed as a porous rhombic dodecahedron structure with 500 μm pore size. Finite element method (FEM) was used to assess the stem behavior under compressive loading compared to a solid stem model. CATIA V5R18 was used for modeling both rhombic dodecahedron and full solid models. Static structural analysis was carried out using ANSYS R18.1 to asses the implant designs. The results indicated enhanced clinical performance of tibial-knee implants compared to the solid titanium implant via increasing the maximum von-Mises stresses by 64% under the tibial tray in porous implant which reduce stress shielding. Also, the maximum shear stress developed in bone/implant interface was reduced by 68% combined with relieving the stress concentration under the stem tip to relieve patients' pain. Finally, porous implants provide cavities for bone ingrowth which improve implant fixation.
- 1 November 2017
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 51 (6) , 474-482
Research : Design and Analysis of a Low-Stiffness Porous Hip Stem
Two major problems are associated with total hip replacement: 1) stress shielding and 2) the adverse tissue reaction to certain elements of the implant material. In this regard, a porous implant provides lower stiffness and vacancies for bone ingrowth, making it more suitable for the human bone compared with a solid stem. Moreover, second-generation titanium biomedical alloys, such as TNZT (Ti35Nb7Zr5Ta) and TMZF (Ti12Mo6Zr2Fe), have been introduced to prevent the adverse tissue reactions related to aluminum and vanadium elements of the popular Ti6Al4V alloy. In the current work, an analysis was performed based on uniaxial compression testing of cubic Ti6Al4V structures of different porosities to predict the governing equations that relate the relative density of the structure to the mechanical properties of the structure according to the Gibson-Ashby model. A numerical study was conducted to evaluate the change in stress distribution obtained by incorporating the new titanium alloys in porous hi...
- 1 November 2017
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 51 (6) , 474-482
Research : Design and Analysis of a Low-Stiffness Porous Hip Stem
Two major problems are associated with total hip replacement: 1) stress shielding and 2) the adverse tissue reaction to certain elements of the implant material. In this regard, a porous implant provides lower stiffness and vacancies for bone ingrowth, making it more suitable for the human bone compared with a solid stem. Moreover, second-generation titanium biomedical alloys, such as TNZT (Ti35Nb7Zr5Ta) and TMZF (Ti12Mo6Zr2Fe), have been introduced to prevent the adverse tissue reactions related to aluminum and vanadium elements of the popular Ti6Al4V alloy. In the current work, an analysis was performed based on uniaxial compression testing of cubic Ti6Al4V structures of different porosities to predict the governing equations that relate the relative density of the structure to the mechanical properties of the structure according to the Gibson-Ashby model. A numerical study was conducted to evaluate the change in stress distribution obtained by incorporating the new titanium alloys in porous hi...
- 13 October 2017
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 41 (8) , 681-691
Pre-clinical evaluation of the mechanical properties of a low-stiffness cement-injectable hip stem
In total hip arthroplasty (THA), the femoral stem can be fixed with or without bone cement. Cementless stem fixation is recommended for young and active patients as it eliminates the risk of loss of fixation at the bone–cement and cement–implant interfaces. Cementless fixation, however, suffers from a relatively high early revision rate. In the current research, a novel low-stiffness hip stem was designed, fabricated and tested. The stem design provided the option to inject biodegradable bone cement that could enhance initial stem stability. The stem was made of Ti6Al4V alloy. The proximal portion of the stem was porous, with cubic cells. The stem was fabricated using electron beam melting (EBM) technology and tested in compression and bending. Finite-element analysis was used to evaluate stem performance under a dynamic load representing a stair descending cycle and compare it to the performance of a solid stem with similar geometry. The von Mises stresses and maximum principal strains generated within the bone increased after porous stem insertion compared to solid stem insertion. The low-modulus stem tested in this study has acceptable mechanical properties and generates strain patterns in bone that appear compatible with clinical use.
- 13 October 2017
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 41 (8) , 681-691
Pre-clinical evaluation of the mechanical properties of a low-stiffness cement-injectable hip stem
In total hip arthroplasty (THA), the femoral stem can be fixed with or without bone cement. Cementless stem fixation is recommended for young and active patients as it eliminates the risk of loss of fixation at the bone–cement and cement–implant interfaces. Cementless fixation, however, suffers from a relatively high early revision rate. In the current research, a novel low-stiffness hip stem was designed, fabricated and tested. The stem design provided the option to inject biodegradable bone cement that could enhance initial stem stability. The stem was made of Ti6Al4V alloy. The proximal portion of the stem was porous, with cubic cells. The stem was fabricated using electron beam melting (EBM) technology and tested in compression and bending. Finite-element analysis was used to evaluate stem performance under a dynamic load representing a stair descending cycle and compare it to the performance of a solid stem with similar geometry. The von Mises stresses and maximum principal strains generated within the bone increased after porous stem insertion compared to solid stem insertion. The low-modulus stem tested in this study has acceptable mechanical properties and generates strain patterns in bone that appear compatible with clinical use.
- 1 October 2017
- Published by Elsevier in Additive Manufacturing
- Vol. 17, 169-175
Electron beam melted scaffolds for orthopedic applications
- 1 October 2017
- Published by Elsevier in Additive Manufacturing
- Vol. 17, 169-175
Electron beam melted scaffolds for orthopedic applications