Dmitry A. Terpelov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dmitry A. Terpelov has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Grigory V. Gelikonov
A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanova Street, 603950 Nizhny Novgorod, Russia
3 shared publications - Pavel A. Shilyagin
Institute of Applied Physics of the Russian Academy of Sciences
3 shared publications - Dmitry V. Shabanov
Institute of Applied Physics (Russia)
1 shared publication - Evgeny P. Sherstnev
Institute of Applied Physics of the Russian Academy of Sciences, 46 Ul’yanov Street, Nizhny Novgorod 603950, Russia
1 shared publication G. V. Gelikonov
Russian Academy of Sciences
1 shared publicationP. A. Shilyagin
Russian Academy of Sciences
1 shared publication
Latest Publications
- Open Access
An Improved Analytical Model of a Spectrometer for Optical Coherence Tomography
We present an improved analytical model of a spectrometer for optical coherence tomography (OCT), which more accurately describes the OCT in-depth sensitivity fall-off. The model considers the intrinsic spectral resolution of the dispersive element and the influence of additional components (inequidistance-correcting prism). The model is validated by experimental data obtained both from other studies and our own experiments. The influence of the frequency response of the CCD electrical circuit and the analog-to-digital converter to the OCT signal fall-off was also detected and was shown to be significant in some cases.
Open AccessAn Improved Analytical Model of a Spectrometer for Optical Coherence Tomography
We present an improved analytical model of a spectrometer for optical coherence tomography (OCT), which more accurately describes the OCT in-depth sensitivity fall-off. The model considers the intrinsic spectral resolution of the dispersive element and the influence of additional components (inequidistance-correcting prism). The model is validated by experimental data obtained both from other studies and our own experiments. The influence of the frequency response of the CCD electrical circuit and the analog-to-digital converter to the OCT signal fall-off was also detected and was shown to be significant in some cases.
- 1 July 2019
- Published by Springer Nature in Radiophysics and Quantum Electronics
- Vol. 62 (2) , 151-158
Elimination of Artifacts Caused by the Nonidentity of Parallel Signal-Reception Channels in Spectral Domain Optical Coherence Tomography
- 1 July 2019
- Published by Springer Nature in Radiophysics and Quantum Electronics
- Vol. 62 (2) , 151-158
Elimination of Artifacts Caused by the Nonidentity of Parallel Signal-Reception Channels in Spectral Domain Optical Coherence Tomography
- 12 November 2017
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 60 (6) , 868-874
A data-acquisition and control system for spectral-domain optical coherence tomography with a speed of 91 912 A-scans/s based on a USB 3.0 interface
We describe a system of optical spectrum registration at the output of an interferometer with controlled phase shifts for an experimental device intended for visualizing the internal structure of an optically turbid specimen, using the method of spectral domain optical coherence tomography. A device for spectral domain optical coherence tomography based on a common-path optical scheme with a USB 3.0 interface for inputting data into a computer has been developed. An imaging speed of 91 912 A-scans/s has been attained. At the achieved speed, a series of live experiments were carried out to visualize the internal structure of skin tissues from a finger and front segments of an eye.
- 12 November 2017
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 60 (6) , 868-874
A data-acquisition and control system for spectral-domain optical coherence tomography with a speed of 91 912 A-scans/s based on a USB 3.0 interface
We describe a system of optical spectrum registration at the output of an interferometer with controlled phase shifts for an experimental device intended for visualizing the internal structure of an optically turbid specimen, using the method of spectral domain optical coherence tomography. A device for spectral domain optical coherence tomography based on a common-path optical scheme with a USB 3.0 interface for inputting data into a computer has been developed. An imaging speed of 91 912 A-scans/s has been attained. At the achieved speed, a series of live experiments were carried out to visualize the internal structure of skin tissues from a finger and front segments of an eye.
- 31 May 2012
- Published by IOP Publishing in Quantum Electronics
- Vol. 42 (5) , 390-393
Suppression of image autocorrelation artefacts in spectral domain optical coherence tomography and multiwave digital holography
- 31 May 2012
- Published by IOP Publishing in Quantum Electronics
- Vol. 42 (5) , 390-393
Suppression of image autocorrelation artefacts in spectral domain optical coherence tomography and multiwave digital holography